Interlogix NS3552-8P-2S-V2 User manual

Category
Network switches
Type
User manual
NS3552-8P-2S-V2 User
Manual
P/N 1073552-EN • REV B • ISS 25JAN19
Copyright
©
2019 United Technologies Corporation. All rights reserved.
Interlogix is part of UTC
Climate, Controls & Security, a unit of United Technologies
Corporation
. Specifications subject to change without notice.
Trademarks and patents
Trade names used in this document may be trademarks or registered trademarks of the
manufacturers or vendors of
the respective products.
Manufacturer
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626
-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Version
This document applies to
NS3552-8P-2S-V2.
FCC compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
mus
t accept any interference received, including interference that may cause undesired
operation.
FCC compliance
Class A:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in acc
ordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at hi
s own expense.
Canada
This Class A digital apparatus complies with CAN ICES
-003 (A)/NMB-3 (A).
Cet appareil numérique de la classe A est conforme à la norme CAN ICES
-003
(A)/NMB
-3 (A).
ACMA compliance
Notice!
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
Certification
EU directives
This product and
- if applicable - the supplied accessories too are marked with "CE" and
comply
therefore with the applicable harmonized European standards listed under the
EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19
/EU (WEEE directive): Products marked with this symbol cannot be disposed of
as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information see:
www.recyclethis.info.
Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN
EXPERIENCED SECURITY PROFESSIONAL. UTC FIRE & SECURITY CANNOT
PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”
OR “AUTHORIZED
RESELLER”
, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please
check www.firesecurityproducts.com
/policy/product-warning/ or scan the following code:
Contact information and
manuals/ tools/ firmware
For contact information and to download the latest manuals, tools, and firmware, go to the web
site of your region.
Americas: www.interlogix.com
EMEA: www.firesecurityproducts.com
Manuals are
available in several languages
Australia/New Zealand: www.utcfs.com.au
NS3552-8P-2S-V2 User Manual 1
Content
Important information 4
Chapter 1 Introduction 5
Package contents 5
Product description 5
Product applications 9
Product features 10
Product specifications 14
Chapter 2 Installation 19
Hardware description 19
Installing the industrial managed switch 26
Cabling 29
Chapter 3 Switch management 35
Requirements 35
Management access overview 35
CLI mode management 36
Web management 38
SNMP-based network management 38
Chapter 4 Web configuration 40
Main web page 42
System 43
DHCP server 67
UDLD 79
Simple Network Management Protocol (SNMP) 81
Port management 91
Link aggregation 98
VLAN 106
Spanning Tree Protocol (STP) 131
Multicast 149
Quality of Service (QoS) 172
Access Control Lists (ACL) 195
Authentication 209
Security 243
MAC address table 259
LLDP 265
Network diagnostics 278
Loop protection 283
RMON 285
Ring 294
Power over Ethernet (PoE) 307
Port identification 319
2 NS3552-8P-2S-V2 User Manual
Chapter 5 Command line interface 320
Accessing the CLI 320
Telnet login 320
Chapter 6 Command line mode 321
System Command 322
IP Command 328
Port Management Command 334
MAC Address Table Command 338
VLAN Configuration Command 341
Private VLAN Configuration Command 348
Security Command 350
Spanning Tree Protocol Command 396
Link Aggregation Command 405
Link Aggregation Control Protocol Command 407
LLDP Command 410
LLDP MED Command 414
Thermal Command 418
PoE Command 419
Ethernet Virtual Connections Command 420
Ethernet Protection Switching Command 425
Maintainence entity End Point Command 426
Quality of Service Command 433
Mirror Command 446
Configuration Command 447
Firmware Command 448
UPnP Command 448
MVR Command 450
Voice VLAN Command 453
Ethernet Ring Protection Switching Command 458
Loop Protect Command 462
IPMC Command 464
VLAN Control List Command 472
SMTP Command 476
DIDO Command 478
Show Command 482
Chapter 7 Switch operation 487
Address table 487
Learning 487
Forwarding and filtering 487
Store-and-forward 487
Auto-negotiation 488
NS3552-8P-2S-V2 User Manual 3
Chapter 8 Troubleshooting 489
Appendix A Networking connection 491
Glossary 493
4 NS3552-8P-2S-V2 User Manual
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be liable
for any lost profits or business opportunities, loss of use, business interruption, loss of
data, or any other indirect, special, incidental, or consequential damages under any
theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you.
In any event the total liability of UTCFS shall not exceed the purchase price of the
product. The foregoing limitation will apply to the maximum extent permitted by
applicable law, regardless of whether UTCFS has been advised of the possibility of
such damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or
loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you
should read.
NS3552-8P-2S-V2 User Manual 5
Chapter 1
Introduction
The description of the IFS NS3552-8P-2S-V2 model is as follows:
Industrial L2+ 8-port 10/100/1000T 802.3at PoE
+ 2-port 100/1000X SFP managed switch
Unless specified, the term “industrial managed switch” mentioned in this user manual
refers to the NS3552-8P-2S-V2.
Package contents
Open the box of the industrial managed switch and carefully unpack it. The box should
contain the following items:
The industrial managed switch × 1
Quick installation guide × 1
DIN rail kit x 1
Wall mounting kit x 1
RS232 console cable x 1
SFP dust-proof cap x 2
RJ45 dust-proof cap x 9
If any of these are missing or damaged, contact your dealer immediately. If possible,
retain the carton including the original packing materials for repacking the product in
case there is a need to return it to us for repair.
Product description
Centralized Power Management for Gigabit Ethernet Networking
To fulfill the demand of higher power required PoE network applications with Gigabit
speed transmission, the industrial managed switch features high performance Gigabit
IEEE 802.3af PoE (Up to 15.4 W) and IEEE 802.3at PoE Plus (Up to 30.8 W) on all
Chapter 1: Introduction
6 NS3552-8P-2S-V2 User Manual
ports. A maximum of 30.8 W is available on each Gigabit port of the industrial managed
switch for powering per PD, with a maximum PoE delivery of 240 W for all ports in order
to satisfy the increasing needs of power consumption by PDs. Providing Gigabit
throughput and high power supply, the industrial managed switch optimizes the
installation and power management of network devices such as 11n wireless access
points (AP) with Gigabit PoE LAN port, security PTZ / Speed Dome network video
camera, large screen PoE Video phones, thin-clients, etc.
Intelligent powered device alive check
The industrial managed switch can be configured to monitor connected powered device
(PD) status in real time via a ping action. After the PD stops working and responding,
the industrial managed switch resumes the PoE port power and puts the PD back to
work. The industrial managed switch greatly enhances the network reliability through
the PoE port resetting the PD’s power source and reducing the administrator
management burden.
PoE schedule for energy saving
Under the trend of energy saving worldwide and contributing to environmental
protection, the industrial managed switch can effectively control the power supply in
addition to its capability of providing high Watt power. The “PoE schedule” function
helps you to enable or disable PoE power feeding for each PoE port during specified
time intervals, and is a powerful function to help SMBs or enterprises save power and
money.
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 7
Cost-effective IPv6 managed Gigabit switch solution for SMB
To fulfill the demand of IPv6 (Internet Protocol version 6) network infrastructure, the
industrial managed switch supports both IPv4 and IPv6 management functions. It can
work with current IPv4 network structure and also support the IPv6 network structure.
With easy and friendly management interfaces and plenty of management functions
included, the industrial managed switch is the best choice for ISP to build the IPv6
FTTx edge service and for SMB to connect with IPv6 network.
Diversity for multiple applications
The industrial managed switch is a desktop size, Layer 2 / Layer 4 full managed Gigabit
switch that can handle extremely large amounts of data in a secure topology linking to
an Enterprise backbone or high capacity network server with 20 Gbps switching fabric.
The powerful features of QoS and network security provided by the industrial managed
switch provides effective data traffic control for ISPs and Enterprise VoIP, video
streaming, and multicast applications. It is ideal for the remote access layer of campus
or enterprise networks and the aggregation layer of IP metropolitan networks.
Robust layer 2 features
The industrial managed switch can be programmed for advanced switch management
functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Multiple
Spanning Tree Protocol (MSTP), layer 2 to layer 4 QoS, bandwidth control, and IGMP /
MLD snooping. The industrial managed switch provides 802.1Q Tagged VLAN, and a
maximum of 255 VLAN groups are allowed. Via aggregation of supporting ports, the
industrial managed switch allows the operation of a high-speed trunk combining
multiple ports. It enables maximum up to 5 groups of 10 ports for trunk and also
supports fail-over..
Enhanced security
The industrial managed switch offers comprehensive layer 2 to layer 4 access control
list (ACL) for enforcing security to the edge. It can be used to restrict to network access
by denying packets based on source and destination IP address, TCP/UDP port
number, or defined typical network applications. Its protection mechanism also
comprises 802.1x port-based and MAC-based user and device authentication. With the
private VLAN function, communication between edge ports can be prevented to ensure
Chapter 1: Introduction
8 NS3552-8P-2S-V2 User Manual
user privacy. The industrial switches also provide DHCP snooping, IP Source Guard
and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard
ARP packets with invalid MAC addresses. The network administrator can now construct
highly secured corporate networks in considerably less time and with less effort than
before.
Excellent traffic control
The industrial managed switch is loaded with powerful traffic management and QoS
features to enhance services offered by telecoms. The QoS features include wire-
speed Layer 4 traffic classifiers and bandwidth limiting that are particularly useful for
multi-tenant units, multi business units, Telco, or Network Service Provider applications.
The industrial managed switch also empowers the enterprises to take full advantage of
limited network resources and provides the best performance in VoIP and video
conferencing transmission.
Efficient and secure management
For efficient management, the industrial managed switch is equipped with console,
web, and SNMP management interfaces. With the built-in web-based management
interface, the industrial switches offers an easy-to-use, platform-independent
management and configuration facility. The industrial managed switch supports
standard Simple Network Management Protocol (SNMP) and can be managed by any
management software based on the standard SNMP v1 or v2 protocol. For text-based
management mode, the industrial managed switch can be accessed via Telnet and the
console port. Moreover, the industrial managed switch offers secure management
remotely by supporting SSH, SSL, and SNMP v3 connections where the packet content
can be encrypted at each session.
Flexible and extendable solution
The industrial managed switch features 100BASE-FX and 1000BASE-SX/LX SFP
(Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can
flexibly choose the suitable SFP transceiver according to the transmission distance or
the transmission speed required to extend the network efficiently. The distance can be
extended from 550 m to 2 km (multi-mode fiber) up to above 10/20/30/40/50/70 km
(single-mode fiber or WDM fiber). They are well suited for applications within enterprise
data centers and distributions.
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 9
Product applications
High power IP surveillance and wireless LAN service in public transportation
Having the capability of IEEE 802.3at Power over Ethernet function, the industrial
managed switch can directly connect with any IEEE 802.3at end-nodes like PTZ (Pan,
Tilt & Zoom) network cameras, PTZ Speed Dome cameras, color touch- screen Voice
over IP (VoIP) telephones, and multi-channel wireless LAN access points. Besides the
wired Internet network, by adopting PoE Wireless LAN structure, the transportation
authority gains benefits from more efficiency and less cost while providing better high-
speed Internet services in a wider area for travelers.
Chapter 1: Introduction
10 NS3552-8P-2S-V2 User Manual
VoIP network in IP office
With a business office expansion, the additional telephones required could be installed
for lower cost via the implementation of a PoE IP telephony system rather than the
traditional circuit wiring telephony system. The industrial managed switch is backward
compatible with 802.3af and helps enterprises to create an integrated data, voice, and
powered network. IP phones and analog telephony adapters can be installed without
additional power cables because the power can be provided via the standard Ethernet
cable from the connected industrial managed switch. With the industrial managed
switch, IP Telephony deployment becomes more reliable and cost effective, which
helps enterprises save tremendous cost when upgrading from traditional telephony
systems to IP telephony communications infrastructure.
Product features
Physical port
Eight 10/100/1000BASE-T gigabit Ethernet RJ45 ports with IEEE 802.3af / 802.3at
PoE injector.
Two 100/1000BASE-X mini-GBIC/SFP slots, SFP type auto detection.
One RJ45 console interface for basic management and setup.
Power over Ethernet
Complies with IEEE 802.3af / IEEE 802.3at Power over Ethernet / End-Span PSE.
Complies with IEEE 802.3af Power over Ethernet / End-Span PSE.
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 11
Up to four ports of IEEE 802.3af/IEEE 802.3at devices powered.
Supports PoE power up to 15.4 W or 30.8 W for each PoE port.
Auto detects powered device (PD).
Circuit protection prevents power interference between ports.
Remote power feeding up to 100 m.
PoE management:
IEEE 802.3af and IEEE 802.3at mode switch control
Total PoE power budget control
Per port PoE function enable/disable
PoE admin-mode control
PoE port power feeding priority
Per PoE port power limitation
PD classification detection
Intelligent PoE features:
Temperature threshold control
PoE usage threshold control
PD alive check
PoE schedule
PD power recycling schedule
Industrial case and installation
IP30 aluminum case
DIN-rail and wall-mount design
48 VDC redundant power with polarity reverse protect function
Supports 6000 VDC EFT protection for power line
Supports Ethernet ESD protection for 6000 VDC
-40 to 75°C operating temperature
Digital input and digital output
Two Digital Inputs (DI)
Two Digital Outputs (DO)
Integrates sensors into auto alarm system
Transfers alarm to IP network via email and SNMP trap
Layer 2 features
Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x PAUSE
frame flow control (full-duplex).
Chapter 1: Introduction
12 NS3552-8P-2S-V2 User Manual
High performance of Store-and-Forward architecture and runt/CRC filtering
eliminates erroneous packets to optimize the network bandwidth.
Storm control support:
Broadcast / Multicast / Unknown-Unicast
Supports VLAN
IEEE 802.1Q tagged VLAN
Up to 255 VLANs groups out of 4094 VLAN IDs
Provider bridging (VLAN Q-in-Q) support (IEEE 802.1ad)
Private VLAN Edge (PVE)
Protocol-based VLAN
MAC-based VLAN
Voice VLAN
Supports STP
STP, IEEE 802.1D Spanning Tree Protocol
RSTP, IEEE 802.1w Rapid Spanning Tree Protocol
MSTP, IEEE 802.1s Multiple Spanning Tree Protocol, spanning tree by VLAN
BPDU Guard
Supports link aggregation
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Cisco ether-channel (static trunk)
Maximum five trunk groups, up to eight ports per trunk group
Up to 16 Gbps bandwidth (duplex mode)
Provides port mirror (many-to-1)
Port mirroring to monitor the incoming or outgoing traffic on a particular port
Loop protection to avoid broadcast loops
Supports Ethernet Ring Protection Switching (ERPS)
Quality of Service
Ingress shaper and egress rate limit per port bandwidth control
Eight priority queues on all switch ports
Traffic classification:
- IEEE 802.1p CoS
- TOS / DSCP / IP Precedence of IPv4/IPv6 packets
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 13
- IP TCP/UDP port number
- Typical network application
Strict priority and Weighted Round Robin (WRR) CoS policies
Supports QoS and In/Out bandwidth control on each port
Traffic-policing policies on the switch port
DSCP remarking
Multicast
Supports IGMP snooping v1, v2, and v3
Supports MLD snooping v1 and v2
Querier mode support
IGMP snooping port filtering
MLD snooping port filtering
Multicast VLAN Registration (MVR) support
Security
Authentication
IEEE 802.1x Port-Based / MAC-Based network access authentication
Built-in RADIUS client to co-operate with the RADIUS servers
TACACS+ login users access authentication
RADIUS / TACACS+ users access authentication
IP-based Access Control List (ACL)
MAC-based ACL
Source MAC / IP address binding
DHCP snooping to filter distrusted DHCP messages
Dynamic ARP inspection discards ARP packets with invalid MAC addresses to IP
address binding.
IP source guard prevents IP spoofing attacks.
Auto DoS rule to defend against DoS attacks.
IP address access management to prevent unauthorized intruders.
Management
Switch management interfaces:
Console / Telnet Command Line Interface
Web switch management
SNMP v1 and v2c switch management
Chapter 1: Introduction
14 NS3552-8P-2S-V2 User Manual
SSH / SSL and SNMP v3 secure access
IPv6 IP address/NTP/DNS management
Built-in Trivial File Transfer Protocol (TFTP) client
System maintenance
- Firmware upload/download via HTTP / TFTP
- Reset button for system reboot or reset to factory default
Four RMON groups (history, statistics, alarms, and events)
IPv6 IP address / NTP / DNS management and ICMPv6
BOOTP and DHCP for IP address assignment
DHCP relay
DHCP Option 82
User privilege levels control
NTP (Network Time Protocol)
Link Layer Discovery Protocol (LLDP) and LLDP-MED
SFP-DDM (Digital Diagnostic Monitor)
Smart discovery utility for deploy management
Network diagnostic
Cable diagnostic technology provides the mechanism to detect and report
potential cabling issues
Product specifications
Model Name
NS3552
-8P-2S-V2
Hardware Specification
s
Copper
Ports
Eight 10/100/1000BASE
-T RJ45 Auto-MDI/MDI-X ports
SFP
+ Slots
Two 1000BASE
-SX/LX/BX SFP interfaces (port 9 and port 10)
Compatible with 1000BASE
-FX SFP
Console Port
1 x RS
-232 to RJ45 serial port (115200, 8, N, 1)
Switch Architecture
Store
-and-Forward
Switch
Fabric
20
Gbps / non-blocking
Throughput
14.8
Mpps @ 64 bytes
Address Table
8
K entries, automatic source address learning and aging
Share
d Data Buffer
4 Mbits
Flow Control
IEEE 802.3x
pause frame for full-duplex
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 15
Back pressure for half-duplex
Jumbo Frame
9
K bytes
Reset Button
<
5 seconds: System reboot
>
5 seconds: Factory Default
Enclosure
IP30 aluminum case
Installation
DIN rail kit and wall
-mount kit
Connector
Removable 6
-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
Removable 6
-pin terminal block for DI/DO interface
Pin 1/2 for DI 1 & 2, Pin 3/4 for DO 1 & 2, Pin 5/6 for GND
Alarm
One relay output for power failure. Alarm relay current carry ability:
1A @ 24
VDC
Digital Input
Two Digital Inputs (DI)
Level 0:
-24~2.1 V (±0.1 V)
Level 1: 2.1~24 V (±0.1 V)
Input load to 24 VDC, 10 mA max.
Digital Output
Two Digital Outputs (DO)
Open collector to 24 VDC, 100 mA max.
LED
System:
Power 1 (Green)
Power 2 (Green)
Fault Alarm (Green)
Ring (Green)
Ring Owner (Green)
Per
10/100/1000T RJ45 Ports:
PoE in-use (Orange)
1000 LNK/ACT (Green)
Per SFP Interface:
100 LNK/ACT (Orange)
1000 LNK/ACT (Green)
Dimensions
152 x 107
x 72 mm
Weight
1.684 kg
Power Requirement
D
C 48 V
Power
Consumption
31.9
W / 108.78 BTU (full loading without PoE function)
306
W / 1043.46 BTU (full loading with PoE function)
ESD Protection
6K VDC
EFT Protection
6K VDC
Power over Ethernet
PoE Standard
IEEE 8
02.3af/802.3at PoE / PSE
PoE Power Supply Type
End
-span
Chapter 1: Introduction
16 NS3552-8P-2S-V2 User Manual
PoE Power Output
IEEE 802.3af
Standard
Per port 56 VDC, 350 mA. Max. 15.4 W.
IEEE 802.3at Standard
Per port 56 VDC, 590 mA. Max. 30.8 W.
Power Pin Assignment
End
-span: 1/2(-), 3/6(+)
PoE Power Budget
2
40 W maximum (depending on power input)
Max. number of Class 2
PD
8
Max. number
of Class 3
PD
8
Max. number of Class 4
PD
8
Layer 2
Functions
Basic Management
Interfaces
Console; Telnet; Web browser; SNMP v1, v2c
Secure Management
Interfaces
SSH, SSL, SNMP v3
Port
Configuration
Po
rt disable / enable
Auto
-negotiation 10/100/1000Mbps full and half duplex mode selection
Flow
control disable/enable
Bandwidth control on each port
Power saving mode control
Port Status
Display each port’s
speed duplex mode, link status, flow control status, auto-
negotiation status, trunk
status.
Port Mirroring
TX / RX / both
Many
-to-1 monitor
VLAN
802.1Q tagged
-based VLAN, up to 255 VLAN groups
Q
-in-Q tunneling
Private VLAN
Edge (PVE)
MAC
-based VLAN
Protocol
-based VLAN
Voice VLAN
MVR (Multicast VLAN Registration)
U
p to 256 VLAN groups, out of 4096 VLAN IDs
Link Aggregation
IEEE 802.3ad LACP
/static trunk
Five groups with eight
ports per trunk
QoS
Traffic classification based,
strict priority and WRR
8
-level priority for switching
Port number
802.1p priority
802.1Q VLAN tag
DSCP/ToS field in IP packet
Chapter 1: Introduction
NS3552-8P-2S-V2 User Manual 17
IGMP Snooping
IGMP (v1/v2
/v3) snooping, up to 255 multicast groups
IGMP
querier mode support
MLD Snooping
MLD (v1/v2)
snooping, up to 255 multicast groups
MLD
querier mode support
Access Control List
IP
-based ACL / MAC-based ACL
Up to
123 entries
Bandwidth Control
Per port bandwidth control
Ingress: 500 Kbps~1000 Mbps
Egress: 500 Kbps~1000 Mbps
Standards Conformance
Regulation Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC60068
-2-32 (Free fall)
IEC60068
-2-27 (Shock)
IEC60068
-2-6 (Vibration)
Standards Compliance
IEEE
802.3 10BASE-T
IEEE
802.3u 100BASE-TX/100BASE-FX
IEEE
802.3z Gigabit SX/LX
IEE
E 802.3ab Gigabit 1000T
IEEE 802.3x flow control and back pressure
IEEE 802.3ad port trunk with LACP
IEEE 802.1D
Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Protocol
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN tagging
IEEE 802.1X Port Authentication Network Control
IEEE 802.1ab LLDP
IEEE 802.3af Power over Ethe
rnet
IEEE 802.3at Power over Ethernet Plus
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP version 1
RFC 2236 IGMP version 2
RFC 3376 IGMP version 3
RFC 2710 MLD version 1
FRC 3810 MLD version 2
SNMP MIBs
RFC 1213 MIB
-II
IF
-MIB
RFC 1493 Bridge MIB
RFC 1643 Ethernet MIB
RFC 2863 Interface MIB
Chapter 1: Introduction
18 NS3552-8P-2S-V2 User Manual
RFC 2665 Ether-Like MIB
RFC 2819 RMON MIB (Groups 1, 2, 3 and 9)
RFC 2737 Entity MIB
RFC 2618 RADIUS Client MIB
RFC 2933 IGMP
-STD-MIB
RFC 3411 SNMP
-Frameworks-MIB
IEEE 802.1X PAE
LLDP
MAU
-MIB
Environment
Operating
Temperature:
-40 to 75°C
Relative Humidity:
5 to 95% (non-condensing)
Storage
Temperature:
-40 to 85°C
Relative Humidity:
5 to 95% (non-condensing)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462
  • Page 463 463
  • Page 464 464
  • Page 465 465
  • Page 466 466
  • Page 467 467
  • Page 468 468
  • Page 469 469
  • Page 470 470
  • Page 471 471
  • Page 472 472
  • Page 473 473
  • Page 474 474
  • Page 475 475
  • Page 476 476
  • Page 477 477
  • Page 478 478
  • Page 479 479
  • Page 480 480
  • Page 481 481
  • Page 482 482
  • Page 483 483
  • Page 484 484
  • Page 485 485
  • Page 486 486
  • Page 487 487
  • Page 488 488
  • Page 489 489
  • Page 490 490
  • Page 491 491
  • Page 492 492
  • Page 493 493
  • Page 494 494
  • Page 495 495
  • Page 496 496
  • Page 497 497
  • Page 498 498
  • Page 499 499
  • Page 500 500
  • Page 501 501
  • Page 502 502
  • Page 503 503
  • Page 504 504
  • Page 505 505
  • Page 506 506
  • Page 507 507
  • Page 508 508
  • Page 509 509
  • Page 510 510
  • Page 511 511

Interlogix NS3552-8P-2S-V2 User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI