  • Hello! I am an AI chatbot trained to assist you with the Summers Heat 25-CBPAH User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!

CAUTION
PLEASEREADTHISENTIREMANUALBEFOREINSTALLATIONANDUSEOFTHISPELLETFUELBURNING
APPLIANCE.KEEPCHILDREN,FURNITURE,ANDALLCOMBUSTIBLESAWAYFROMANYHEATINGAPPLIANCE.
SAFETYNOTICE
FAILURETOFOLLOWTHESEINSTRUCTIONSCANRESULTINPROPERTYDAMAGE,BODILYINJURYOREVEN
DEATH.FORYOURSAFETYANDPROTECTION,FOLLOWTHEINSTALLATIONINSTRUCTIONSOUTLINEDIN
THISMANUAL.CONTACTYOURLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSAND
INSTALLATIONINSPECTIONREQUIREMENTS(INCLUDINGPERMITS)INYOURAREA.
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe,VA24574
Rev.03/2019
SAVETHESEINSTRU CTIONS
INSTALLATION&OPERATION
MANUAL
25CBPAH
55SHPCBPAH
55TRPCBPAH
THISWOODHEATERNEEDSPERIODICINSPECTIONANDREPAIRFORPROPEROPERATION.CONSULTTHE
OWNER’SMANUALFORFURTHERINFORMATION.ITISAGAINSTFEDERALREGULATIONSTOOPERATETHIS
WOODHEATERINAMANNERINCONSISTENTWITHTHEOPERATINGINSTRUCTIONSINTHEOWNER’S
MANUAL.
www.heatredefined.com
Parts:(800)5163636
Support:(800)2456489
2
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DONOTRETURNITTO
THEDEALER.CONTACTTECHNICALSUPPORT@18002456489
TamperWarning:
Thiswoodheaterhasamanufacturersetminimumlowburnratethatmustnotbe
altered.Itisagainstfederalregulationstoalterthissettingorotherwiseoperate
thiswoodheaterinamannerinconsistentwithoperatinginstructionsinthis
manual.
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeordoublewide
installationwiththeoutsidecombustionairhookupSeethe“Installation”section
ofthismanualfordetailspertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufacturedHomeandSafety
Standard(HUD),CFR3280,Part24.
WARNING:
USEOFOUTSIDECOMBUSTIONAIRISMANDATORYWITHTHISUNIT.
DONOTOPERATEWITHTHEHOPPEROPEN;LIDMUSTBESHUTANDTIGHTLY
LATCHEDDURINGOPERATION.DONOTOVERFIREYOURUNIT.
Note:England’sStoveWorksdoesnotrecommendusingapelletstoveasyour
onlysourceofheat.
Retainforyourfiles
ModelNumber
DateofPurchase
DateofManufacture
SerialNumber

3
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
Welcome!
Introduction
ThankYou.........................................5
Specifications
HeatingSpecifications.......................6
Dimensions........................................6
EPACompliance.................................6
Installation
InstallationOverview...................7
ClearancestoCombustibles.........8
VentingIntroduction...................9
VentingGuidelines.......................9
AdditionalVentingInformation...10
ApprovedVentingMethods
ThroughtheWall...........11
ThroughtheCeiling........12
ExistingChimney............13
MobileHomeInstallation............14
VentTerminationClearances......15
OutsideAirHookup.....................16
FloorProtection...........................17
DailyOperation
GettingStarted............................18
LightingaFire..............................18
DailyOperationNotes………………19
ControlBoard
ControlBoardSettings................20
ErrorCodes..................................21
PowerFailure……..……………………22
Maintenance
Daily
ImportantNotes..............23
DailyAshRemoval...........23
CleaningtheBurnPot......24
Weekly
BaffleRemoval...........25
CleanOutCovers.............25
Monthly
ImportantNotes…………….26
VentingPipeCleaning…….27
Yearly
ImportantNotes..............28
ExhaustBlower................29
ConvectionBlower...........29
HopperFines....................30
CheckingGaskets.............30
BasicTroubleshooting.......................31
ReplacingComponents
AugerMotor.......................................33
ConvectionBlower.............................34
CombustionBlower............................35
VacuumSwitch...................................36
Igniter.................................................37
Gaskets...............................................38
Glass...................................................39
ControlBoard.....................................40
WiringDiagram..................................41
HopperLidHinges..............................42
HopperLidHandle..............................42
Panels………………………………………………43
Finish……………………………………………….43
IllustratedPartsDetail
ExplodedPartsDiagram……………………44
PartsList……………………………………..…..45
Warranty
SerialTagSample…………………….………..47
WarrantyDetails……………………………....48
ImportantNotice………….…….....…………50
WarrantyReg.Form………………………….51
AIR WASH BAR PLACEMENT
CAUTION:TheAirWashBarmaybecomejarredlooseduringshipping.
BESUREthattheAirWashBarisinstalledproperlybeforeeachfire,
includingaftercleaningandmaintenance.
TheAirWashBarshouldfitintothetwoinstallationholesand‘lean
forward’onthefrontwallofthestove.
Thebendinthebarshouldbendtowardthefrontdooropening,andnot
backwardtowardtheburnpot.

InstallationHoles
AirWashChannels
FireBox
InstalltheAirWashBartabsintotheholes
andnotintotheairwashchannels
Thebendoftheairwashbar
shouldfaceTOWARDthefront
door
FrontDoorO
p
enin
g
AirWashBar
(installed)
AirWashBar
5
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythatbelieves
stronglyina“DoItYourself”spirit;that’sonereasonyoufoundthisproductat
yourfavorite“DoItYourself”store.
Weintentionallydesignandbuild
ourstovessothatanyhomeownercanmaintain
theirstovewithbasictools,andwe’realwaysmorethanhappytohelpyoudothe
jobaseasilyandasinexpensivelyaspossible.However,whileremainingsimple,
ourstovesaredesignedtoperformextremelyefficiently,helpingdelivermore
heatfromless
fuel.
PleaselookattheextensiveHelpsectiononourwebsiteandcallourTechnical
SupportDepartmentat(800)2456489ifyouneedanyhelpwithyourstove.We
arenearlyalwaysableto“walkyouthrough”anyinstallationissues,repairs,
problemsorotherquestionsthatyoumayhave.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EveryoneatEngland’sStoveWorks
PleaseNote:Whileinformationobtainedfromourwebsiteandthroughour
TechnicalSupportlineisalwaysfreeofcharge,therewillbeaservicecharge
incurredwithany“onsite”repairsormaintenancethatwemayarrange.
Thismanualencompassesallversionsofthe25CBPAH,includingthe55SHPCBPAHandthe55TRPCBPAH.
However,forsimplicityofdescription,thestovewillbereferredtobythegeneric25CBPAHdesignation.

This manual is available for free download on the manufacturer’s web site. It is a copyrighted document and resale
is strictly prohibited. The manufacturer may update this manual occasionally and cannot be responsible for
problems including injuries or damages resulting from the use of information found in any manual from
unauthorized sources.
CAUTION:Stoveisheavy.
Inaddition,whenhandlinganysheetmetalproducts,beawarethattheremaybesharpedgesorburrs.
Althoughwemakeeveryefforttoeliminateanysharpedges,pleaseusecautionwhenhandlinganymetalparts.
Remembertodisconnect(unplug)thestovefromthepowersourceand
allowittocompletelycooldown
beforeperforminganymaintenance.
6
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
SPECIFICATIONS
HeatingSpecifications
ApproximatePelletBurnRate**………….…………0.7to1.7kg/hr(1.5to3.8lbs/hr)
MaximumBurnTime**………………………………………………………………………..76hours
HeatOutput**…………………………………………………………13,42921,807BTU/hr
ApproximateSquareFootageHeated***…….………………………….upto2,200sq.ft.
HopperCapacity………………………………………………………………………….…..120pounds
Dimensions

EPAandSafetyComplianceSpecifications
EPAComplianceStatus…….........................................Certifiedtocomplywith2020particulate
emissionstandardsusingpelletfuel.
U.S.TestStandard:USEPA40CFRPart60,Subpart60.536
ParticulateEmissions …………………………………………………………………0.763grams/hr
COEmissions………………………………………………………………………….0.013grams/min
Efficiency………………………………………………………………………………………77.6%(HHV)
TestedToUL148200,ASTME1509,ULC/ORDC1482M1990&ULCS62700
Notesforthisunit:Productmayvaryslightlyfromdiagram.Clearancesaretheminimumforthisunit
andmayneedtobeincreasedinthereartohaveproperventclearances.Followallventingmanufacturer
clearancesandlocalcodes.
*‐AstestedperASTM277910
**‐Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbersmayvary.
***‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulation
andamyriadofotherfactors.Usethisinformation
inconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
7
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeoffactorsthat
shouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatternsTohelppreventaccidents,thestoveshouldbeplacedinalocation
whereitisout ofthewayofnormaltravelthrough
thehome.
2. HeatFlowandEfficiencyWhendecidingonalocationforthestove,considertheway
heatmovesthroughoutyourhome.Installthestovewhereyouneedtheheat;
basementinstallationsoftendonotallowsufficientheattoflowtotheupperfloorsand
atopfloor
installationwillnotallowanyheattoreachthefloorsbelow. Always
considerthatheatrisesandwilltakethepathofleastresistancewhileitisstillhot.
3. ExhaustLocationOutsidewallsaregenerallythebestplacetoinstalla stove,since
theyalloweasyexhaustandintake
airinstallation(usingourDuraVentAC3000Kit,AC
33000ifCanada).Ifthereisnotafeasiblewaytoinstallthestoveonanoutsidewall,
therearemethodsforventingthestoveupthroughtheroof,buttheytendtobemore
costlybecausetheyinvolvethe
useofmorepelletventpipeandcanoftenmakeoutside
airinstallationmoredifficult.
4. WallConstructionLocatingthestovesothattheexhaustsystemcanpassbetween
studswillsimplifytheinstallationandeliminatetheneedtoreframeanysectionsofthe
walltoaccommodatethewallthimble.
Warning
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Do Not Over fire – If any external part starts to glow, you are over firing. Reduce feed rate.
Over firing will void your warranty.
Comply with all minimum clearances to combustibles as specified. Failure to comply may
result in a house fire.
Tested and approved for wood pellets only. Burning any other fuel will void your warranty.
For use with Premium grade wood pellets only.
8
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ClearancestoCombustibles

CAUTION
UnitcanbeveryHOTwhileinoperation.Keepchildrenaway.
Supervisechildreninthesameroomasthisappliance.
Alertchildrenandadultstothehazardsofhightemperatures.
DoNOToperatewithprotectivebarriersopenorremoved.
Keepclothing,furniture,draperiesandothercombustiblesaway.
InstallationMUSTcomplywithlocal,regional,stateandnationalcodesandregulations.
Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictio n about restrictions,install a tioninspection,and
permits.
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
UnittoRear
Wall(A)
UnittoSide
Wall(B)
UnittoCorner
(C)
0in. 8in. 6in.
0mm 203mm 152mm
9
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionairthroughthe
burnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.Thisunitmustbe
installedinaccordancewiththefollowingdetaileddescriptionsofventingtechniques;notinstalling
thestovein
accordancewiththedetailslistedherecanresultinpoorstoveperformance,property
damage,bodilyinjuryordeath.England’sStoveWorksisnotresponsibleforanydamageincurred
duetoapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupportline
(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallationmeetslocal
andnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,westrongly
recommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
WARNING‐INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearancesincludedwith
yourventingsystem.
DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
DONOTinstalla
fluepipedamperoranyotherrestrictivedeviceintheexhaustventingsystem
ofthisunit.
USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/firestop
whenpassingthroughaceiling.
ONLYuse3.0”or4.0”TypeLorTypePLpipeapproved
forpelletstoveventing;DONOTuse
galvanizedorBVentpipe.
SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)toprevent
smokespillageintothehome.
AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventing
system
andwillresultinpoorstoveperformance.
INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromenteringyour
homeintheeventofapoweroutage.
INSPECTyourventingsystemoften,tobecertainitisclearofflyashandotherrestrictions.
CLEANtheventingsystemasdetailedinthemaintenancesectionofthismanual.
WARNING
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
HOT!Donottouch!Severeburnsorclothingignitionmayresult.
Glassandothersurfacesarehotduringoperation.
Donotattempttotouchoropenthefrontorsidepanelsduringoperation.Thiscouldresultinsevere
burnsorin
j
ur
y
.
10
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
AdditionalVentingInformation
Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassemblingyour
ventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimblefrom
another).
Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthesystem.
Thishelpsevacuatesmokefromthestoveintheeventofapowerfailureorcombustion
blowerfailure.
Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;toreduce
frictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0in.
pelletpipe.
Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchasa
porchordeck.
FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativeto
windowsandotheropeningsinthedwelling.
o NFPA211(2006ed.)Section10.4Termination:10.4.5
(1)
Theexitterminalofamechanicaldraftsystemotherthandirectventappliances
(sealedcombustionsystemappliances)shallbelocatedinaccordancewiththe
following:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10ft.
(3.0m).
(b)Notlessthan4
ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.(305
mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan7ft.
(2.1m)abovegradewhenlocated
adjacenttopublicwalkways.
Distancebetweentheterminationopeningandgradeshouldbeaminimumof2ft.(24in.)
contingentonthegradesurfacebelowthetermination.Whendeterminingthetermination
heightabovegrade,considersnowdriftlinesandcombustiblessuchasgrassorleaf
accumulation.Inareas
wheresignificantsnowfallispossible,theterminationheightmustbe
sufficientlyhightokeeptheterminationfreeofsnowaccumulation.
Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentoftheunitor
ventingsysteminsuchamannerthatcouldresultinahazardousinstallation.
A
chimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilarconcealed
space,orafloor,orceiling.
Wherepassagethroughawallorpartitionofcombustiblematerialisdesired,theinstallation
shallconformtoCAN/CSAB365.
WARNING:
VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.
Noncombustibleshieldingorguardsmayberequired.
11
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod1:ThroughtheWall
Generallythesimplestinstallationmethod,venting
throughthewallusingourAC3000kit,AC33000ifCanada
(orsimilarventingsystem)isalsothepreferredventing
method.Itminimizeshorizontalpipe,allowsthestoveto
beinstalledclosetothewallandkeepsthecleanouttee
onthe
outsideofthehouse,foreaseofcleaning.
Wheninstallinganyventingsystem,TypeLorTypePL
pipemustbeusedandallclearancestocombustibles
(listedbythepipemanufacturer)mustbestrictlyadhered
to.
Usethepipemanufacturer’sapprovedthimblefor
passingthroughacombustible
wall,andmaintainatleast
theminimumclearancestocombustibles.
Useanappliancecollarwherethepelletventconnects
totheexhaustoutputofthepelletstoveandattachthe
appliancecollartotheexhaustbloweroutputusingthree
sheetmetalscrews.
Securethepelletventtotheoutside
ofthehouseusingawallstrapjustbelowthe90degree
elbow.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingused
isnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
Thisinstallationtype
canbemodifiedforbasement(Basementinstallationsshouldalwaysbe
performedbyaprofessionalinstaller)orotherinstallationswhereintheteeandverticalsectionof
thepipewouldbeinsidethehomeandtheventingsystemwouldsimplypasshorizontallythrough
thethimbleandthenterminate.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
12
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod2:ThroughtheCeiling
Ventingthroughtheceiling/roofmaybetheonlyfeasible
ventingoptioninsomecasesandisafactoryrecommended
installation.
Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibleslistedbythe
pipemanufacturermustbestrictlyadheredto.
Usethepipemanufacturer’sapprovedceilingsupportfor
passingthroughacombustibleceiling,aswellastherequired
firestops,radiationshields,flashingandstormcollar.
Becertaintofollowthemanufacturer’srequiredheightof
terminationabovetheroofline,andmaintainatleastthe
minimumclearancesto
combustibles.
Useanappliancecollarwherethepelletventconnectstothe
exhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwith
yourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontallythroughthe
wallfromthestove,thentransitionstoverticalandterminatesabovetheroofline.Whenusing
thismodified
versionofthisinstallationbecertaintocarefullyfollowtheventingsystem
manufacturer’sinstructionsdiligently.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,and
followalllocalcodes.

Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
13
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod3:ExistingChimneySystem
Usinganexistingmasonryorfactorybuiltchimneyforventingistheonlyotheracceptablemethod
forventingthispelletunit.
UseTypeLorTypePLventingpipeuntilenteringthe
existingchimney.Usetheappropriatelysizedadapterwhen
transitioningfromthepelletventpipetothemasonry
or
factorybuiltthimbleandbecertainthattheadapteris
sealedtightlytoboththepelletventingsystemandthe
existingchimney.
Beforeusinganexistingchimney,becertainitisingood
condition(Achimneysweepinspectionishighly
recommended).Also,makesurethechimneymeetsthe
minimumstandardslistedinNFPA211(Achimney
professionalcanconfirmthisuponinspection).
Ifconnectingthisstovetoafactorybuiltchimney,itmay
ONLYbea6”flue,UL103HTventingsystem(ULCS629if
Canada).Connectiontoanyotherfactorybuiltchimneymay
resultinapoorly
operatingordangerousstoveinstallation.
Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemustbe
considered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequirereliningwithan
approvedpelletstovechimneyliningsystem.
Useanappliance
collarwherethepelletventconnectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetalscrews.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecific
pipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
an
alternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeachindividual
installation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,andfollowalllocal
codes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
14
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
MobileHomeInstallation
TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseethe“OutsideAir”sectiononpage16formoreinformationregarding
outsideairconnections.
Theoutsideairinletmustbekeptclearofleaves,iceandother
debris.Keepingtheoutsideair
inletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandtheholes
providedinthebottomofthebaseforthispurpose.Outdooraired
spaceheatersmustbe
attachedtothestructure.
ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollowthe
ventingmanufacturer’s
minimumclearancerequirements.Similarly,becertaintheventing
systemusedisapprovedformobilehomeuse.
InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR3280,
Part24aswellasanyapplicablelocalcodes.
Usesiliconetocreateaneffectivevaporbarrierat
thelocationwherethechimneyoroutsideair
ductingpassesthroughtotheexteriorofthestructure.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALLANDCEILING/ROOFMUSTBE
MAINTAINED.DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANYOTHER
SUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHESTRUCTURALINTEGRITYOFTHEHOME.
WARNING:DONOTINSTALLINASLEEPINGROOM.
JoistShield/Firestop MobileHomeApproved
TypeLorTypePLPellet
VentPipe
ChimneyCap/SparkArrestor RoofFlashingandStorm
Collar
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
15
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
VENTTERMINATIONCLEARANCES
A)Min.4ftclearancebeloworbesideanydoororwindow that opens.
B)Min.1ftclearanceaboveanydoororwindowthatopens.
C)Min.2ftclearancefromanyadjacentbuilding.
D)Min.7ftclearancefromanygradewhenadjacenttopublicwalkways.
E)Min.2
ftclearanceaboveanygrass,plants,orothercombustiblematerials.
F)Min.3ftclearancefromaforcedairintakeofanyappliance.
G)Min.2ftclearancebeloweavesoroverhang.
H)Min.1ftclearancehorizontallyfromcombustiblewall.
I)Ventsinstalledwithmechanicalexhaustersshallterminatenot
lessthan12in.(305mm)abovethe
highestpointwheretheypassthroughtheroofsurface.

NotesonterminationofPelletVentPipefromNFPA211(2006ed.)Section10.4Termination:10.4.5
(Seealso“INSTALLATION”sectionofmanualANDadditionalnotesabove):
Notlessthanthree(3)feetaboveanyforcedairinletlocatedwithinten(10)feet.
Notlessthanfour(4)feetbelow,four(4)feethorizontallyfrom,orone(1)footaboveanydoor,
windoworgravityairinletintoanybuilding.
Notlessthantwo(2)feetfromanadjacentbuilding,andnotlessthanseven(7)feetabovegrade
wherelocatedadjacenttopublicwalkways.
Theexhaustexitshallbea rrangedsothatthefluegases arenotdirectedsothatitwillaffectpeople,overheat
combustiblestructures,orenterbuildings.Forceddraftsystemsandallpartsofinduceddraftsystemsunderpositive
pressureduringoperationshallbeinstalledgastightortopreventleakageofcombustion
productsintoa building.
Throughthewallventsshallnotterminateoverpublicwalkways,orwherecondensateorvaporcouldcreatehazards
oranuisance.
Besuretofollowlocalcodesandallmanufacturer’sinstructions(includingexhaustpipe).
Consultaprofessional installerand/orcallTechnicalSupportifyouhaveany
questions.
16
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
OUTSIDEAIRHOOKUP
Theuseofoutsidecombustionairismandatoryonthispelletstove.
Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthe
stove;usetheincludedoutsideairkittoattachyourstovetooutside
combustionair.Instructionsandallthepartsneededtomakethe
outsideair
connectiontoyourpelletstoveareincludedwiththeoutsideairkit.
Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyour stove
installation,othermaterialsmaybeused,providedthefollowingrulesare
followed:
Thepipeusedforoutsideair
hookupmustbemetal,withaminimum
thicknessof.0209in.(25gaugemildsteel)orgreaterandaninside
diameterofapproximately2.0in.
Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
Long
runsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.
Duetofrictionalresistanceinpipe,anyexcessiveoutsideairpipingcan
resultinpoorstoveperformance.
Ascreenorotherprotectiondevicemustbefittedovertheoutsideair
terminationpointtopreventrain,debrisand
nuisanceanimalsfrom
enteringthepipingsystem.
Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareused
orifthestoveisinstalledinabasement.
Theoutsideair
connectionsystemshouldbeinspectedatleastannuallytobe
certainitisfreefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
1.Wall,floororceilingcavity.
2.Enclosedspacesuchasanattic,garageorcrawlspace.
17
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
FLOORPROTECTION
Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledonacombustible
floor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible(i.e.aconcretefloorina
basement)andhasanRvalueequaltoorhigher
than.2,nofloorprotectionisneeded(althougha
decorativefloorprotectorcanstillbeusedforaestheticreasons).
PrefabricatedfloorprotectorswhichareULlisted(ULCifCanada)orequivalentcanbepurchasedorafloor
protectorcanbebuiltfromstandardmaterials:twosheetsof.5”thick
cementboardcoveredwithceramic
tilewouldbeasuitablefloorprotectorwhichmeetsthe.2Rvaluerequirement.
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheatingand
coolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints.Ahearth
rugisNOTanapprovedsubstituteforaproperhearthpad.
FortheUSandCanada:Thefloorprotectormustextendatleast6in.(152mm)fromthefront&sides.
InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathandextends2in.(50.8
mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectlyunderneathanyverticalventing
pipe.

18
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
DAILYOPERATION
GettingStarted
Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnectthisunittoa
workingoutlet;werecommendusingasurgeprotectortohelpprotecttheelectroniccomponentsfrom
damage.
BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;pressingthe
“ON”buttonwiththeunitpluggedinwillinitiatethedryrun.
Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblowerstartand
operatecontinuously.
Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniterportoftheburn
pottobecertainitisoperatingnormally.
Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.44)downwithyourfingerandcheck
toseethattheaugeristurning.Releasethehopperlidswitchandbecertainthattheaugerstops
turning.DONOTPUTYOURFINGERSINTHEHOPPERORNEARTHEROTATINGAUGER.
Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplaywindows(More
informationonErrorCodescanbefoundintheErrorCodesectionofthismanual).
Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormaloperation.
LightingaFire
Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthehopperlidusing
theflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,sincepelletsbearing
thePFIstampofapprovalwillbelowinashandmoisture,highinBTU’s,anduniforminsizeand
quality.
Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,andalthoughtheashmay
differslightlyinappearanceortexture,bothtypesofpelletswillburncleanlyandefficientlyinthisstove.
Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinputrequiredtolight
thestoveisasimplepressofthe“On”button.
Shortlyafterpressingthe“On”button,thelettersSUwillappearintheheatrangeandblowerspeed
windowsofthecontrolboard.Thisindicatesthestovehasenteredthestartupsequenceandisoperating
normally.
Thefuelfeedrateandcombustionairduringstartupisdeterminedbythecontrolboard,sothestovemay
bestartedonanyheatrange.
Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandtheSUshoulddisappear
fromthecontrolboard.Atthispoint,thestovehasbegunnormaloperationandthedisplaywindowson
thecontrolboardwillremainempty,unlesstheHeatRangeorBlowerSpeedisadjusted.
19
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
Itisnormalfortheunittosmokeduringthefirstfire,aspaintsandoilscure.Thisshoulddissipatewithin
thefirsthour.Openadoorand/orwindowduringthefirstfiretoventilatethearea.

DailyOperationNotes
Onlyhighquality,PremiumGrade¼”(.25in.)diameterwoodpelletsshouldbeusedinthisstove.Using
lowgradewoodpelletswithhighashcontentORwoodpelletswithahighmoisturecontentcancausethe
burnpottofillwithashatamorerapidpaceandcancauseintervalsbetweenperiodicmaintenanceto
becomesignificantlyshorter.Pleasereadthe“Maintenance”sectionofthismanualthoroughlyto
understandhowfuelselectionaffectsstoveoperation,maintenanceandcleaning.
Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcanaffecttheway
pelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseanddecreaseduringoperation,
thereisnolossofefficiency.
Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocationensuresthefuel
willremainpelletizedandlowinmoisturecontent.Also,becertainthatallwoodpelletfuelisstoredata
safedistancefromthepelletheater;storingfuelincloseproximitytothestovecanresultinafire.Donot
installoroperatethisunitoutside,inagreenhouse,orinanyareathatishighinmoisture.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomespreinstalled
fromthefactory.Thisburnpotelevatestheburningpelletsanddeliversairatthepreciselyrequired
locations.Pelletsmustonlybeburnedinthefactoryburnpot;nomodificationsshouldbemadetothis
burnpotandnoadditionalgratesorotherfireelevatorsshouldbeused.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTERFLUID,OR
SIMILARLIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALLSUCHLIQUIDS
WELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVERAPPLYFIRESTARTERTO
ANYHOTSURFACEOREMBERSINTHESTOVE.DONOTUSECHEMICALSORFLUIDS
TOSTARTTHEFIRE.
DONOTBURNFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAORENGINEOIL.
DONOTBURNGARBAGE;LAWNCLIPPINGSORYARDWASTE;MATERIALSCONTAININGRUBBER,
INCLUDINGTIRES;MATERIALSCONTAININGPLASTIC;WASTEPETROLEUMPRODUCTS,PAINTOR
PAINTTHINNERS,ORASPHALTPRODUCTS;MATERIALSCONTAININGASBESTOS;CONSTRUCTION
ORDEMOLITIONDEBRIS;RAILROADTIESORPRESSURETREATEDWOOD;MANUREORANIMAL
REMAINS;PAPERPRODUCTS,CARDBOARD,PLYWOODORPARTICLEBOARD.THEPROHIBITION
AGAINSTBURNINGTHESEMATERIALSDOESNOTPROHIBITTHEUSEOFFIRESTARTERSMADEFROM
PAPER,CARDBOARD,SAWDUST,WAXANDSIMILARSUBSTANCESFORTHEPURPOSEOFSTARTING
AFIREINANAFFECTEDWOODHEATER.BURNINGTHESEMATERIALSMAYRESULTINRELEASEOF
TOXICFUMESORRENDERTHEHEATERINEFFECTIVEANDCAUSESMOKE.
20
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvectionblowerspeed,turn
theunitonandoff,andtestcomponentsforfunction(moreondiagnosticmodelater).
Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAironTemp)arenotmeantto
beadjustedduringnormaloperationoftheunit.Thesebuttonsarefactorypresetandcannotbeadjusted
bytheuser.
Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebuttonshouldturngreen
andthecontrolboardshoulddisplay“SU”shortlyafterpressingthebutton.
Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnredandtheboard
shoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshutdownsequence,andthe
stovewillremaininshutdownmodeuntilithascooleddown.
Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberintheheatrange
displaywindowwillincrease,signifyingthatthecontrolboardisnowadjustingtheheatoutputtoyour
desiredlevel.Theblowerspeedwillincreasethesameamountastheheatrange,becausethestoveis
designedtooperatewiththeblowerspeedgreaterthanorequaltotheheatrange.Pressingthe“Down”
arrowwilldecreasetheheatrangeandblowerspeed.
Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed“Up”arrowuntil
thedesiredblowerspeedisshowninthedisplaywindow.Pressingthe“Down”arrowwilldecreasethe
blowerspeed;however,thecontrolboardwillnotallowtheblowerspeedtobesetlowerthantheheat
range.
Caution
Thisunitismeanttooperateonlywiththemainviewingdoorclosed.Smoke
spillageandaninefficient,lazyburnwillresultfromattemptingtooperatethe
stovewiththedooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafesituationand
canalsogenerateexcesscarbon
monoxide.Carbonmonoxideisanodorless,
colorlessgaswhichcanbedeadly.
BurnONLYwoodpellets.
CarbonMonoxideDetector
England’sStoveWorks,Inc.highlyrecommendstheuseofacarbonmonoxide
detectorintheproximityofthestoveandoneperfloorofthehome.
Acertainamountofcarbonmonoxideisproducedwithinthestoveasabyproductofcombustion.
AllexhaustventconnectionsmustbesealedwithRTVSiliconetoassureatightseal.Anyleaksinto
aconfinedareacausedbyfaultyinstallationorimproperoperationofthestovecouldproduce
dizziness,nauseaandinextremecases,death.TheCOconcentrationduringtestingwasfoundto
be0.013g/min.
/