ACM4, ACM4E, ACM4CB and ACM4CBE
Multi-Output Access Power Controllers
Rev. DSACM4 - D07H
• Theseunitsconvertone(1)12to24voltACorDCinputintofour(4)
independentlycontrolledfusedorPTCprotectedoutputs.Thesepower
outputscanbeconvertedtodryform“C”contacts(ACM4&ACM4Eonly).
Outputsareactivatedbyanopencollectorsinkornormallyopen(NO)dry
triggerinputfromanAccessControlSystem,CardReader,Keypad,Push
Button,PIR,etc.Theunitswillroutepowertoavarietyofaccesscontrol
hardwaredevicesincludingMagLocks,ElectricStrikes,MagneticDoor
Holders,etc.OutputswilloperateinbothFail-Safeand/orFail-Secure
modes.Unitsaredesignedtobepoweredbyonecommonpowersource
whichwillprovidepowerforboththeboardoperationandlockingdevices,
ortwo(2)totallyindependentpowersources,one(1)providingpowerfor
boardoperationandtheotherforlock/accessorypower.TheFACPInter
faceenablesEmergencyEgress,AlarmMonitoring,ormaybeusedto
triggerotherauxiliarydevices.Therealarmdisconnectfeatureis
individuallyselectableforanyorallofthefour(4)outputs.
Overview
ACM4
• AccessPowerControllerw/fuse
protectedoutputs.
ACM4CB
• AccessPowerControllerw/PTC
protectedoutputs.
ACM4E
• ACM4w/enclosure.
ACM4CBE
• ACM4CBw/enclosure.
• 12to24voltACorDCoperation
(settingnotrequired),(.4amp@12volt,
.2amp@24voltcurrentconsumptionwithall
relaysenergized).
• Powersupplyinputoptions:
a)One(1)commonpowerinput
(boardandlockpower).
b)Two(2)isolatedpowerinputs(one(1)for
boardpowerandone(1)forlock/accessorypower).
• Four(4)AccessControlSystemtriggerinputs:
a) Four(4)normallyopen(NO)inputs.
b)Four(4)opencollectorsinkinputs.
c) Anycombinationoftheabove.
• Four(4)independentlycontrolledoutputs:
a) Four(4)Fail-Safeand/orFail-Secure
poweroutputs.
b)Four(4)dryform“C”5ampratedrelayoutputs
(ACM4/ACM4Eonly).
c) Anycombinationoftheabove
(ACM4/ACM4Eonly).
• Four(4)auxiliarypoweroutputs(unswitched).
• Outputratings:
-Fusesarerated3ampeach(ACM4/ACM4E).
-PTCsarerated2.5ampeach(ACM4CB/ACM4CBE).
• Mainfuseisratedat10amp.
Note:Totaloutputcurrentisdeterminedbythe
powersupply,nottoexceedamaximum
of10amptotal.
• RedLEDsindicateoutputsaretriggered
(relaysenergized).
• FireAlarmdisconnect(latchingornon-latching)is
individuallyselectableforanyorallofthe
four(4)outputs.
FireAlarmdisconnectinputoptions:
a) Normallyopen(NO)ornormallyclosed(NC)
drycontactinput.
b)PolarityreversalinputfromFACP
signalingcircuit.
• FACPoutputrelay(form“C”contactrated@1amp
28VDCnotevaluatedbyUL).
• GreenLEDindicateswhenFACPdisconnect
istriggered.
• Removableterminalblocksfacilitateease
ofinstallation.
• Productweight(approximate):
- ACM4E:6.6lbs.
- ACM4CBE:6.7lbs.
• Shippingweight(approximate):
- ACM4E:7.5lbs.
- ACM4CBE:7.6lbs.
ACM4
ACM4E
Specifications