Altronix TROVE T2MK7F4D Installation guide

Type
Installation guide

Altronix TROVE T2MK7F4D is a fully assembled 4-door kit designed to provide secure and reliable access control for commercial and residential properties.

Here's a summary of its capabilities:

  • Complete Kit: Includes Trove2 enclosure, eFlow104NB power supply/charger, ACM4CB access power controller, PD8ULCB power distribution module, and rocker switch bracket.
  • Power and Access Control: Provides 120VAC input power and 6.3A/32V DC output current for powering access control boards and other devices.
  • PTC Protection: Features PTC (Positive Temperature Coefficient) outputs for protection against short circuits and overloads.

Altronix TROVE T2MK7F4D is a fully assembled 4-door kit designed to provide secure and reliable access control for commercial and residential properties.

Here's a summary of its capabilities:

  • Complete Kit: Includes Trove2 enclosure, eFlow104NB power supply/charger, ACM4CB access power controller, PD8ULCB power distribution module, and rocker switch bracket.
  • Power and Access Control: Provides 120VAC input power and 6.3A/32V DC output current for powering access control boards and other devices.
  • PTC Protection: Features PTC (Positive Temperature Coefficient) outputs for protection against short circuits and overloads.
Access & Power Integration
T2MK7F4D
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM4CB - PTC Protected Access Power Controller
- One (1) PD8ULCB - PTC Protected Power Distribution Module
- One (1) RSB1 - Rocker Switch Bracket with one Rocker Sitch
Rev. 041020
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T2MK7F4D
Overview:
Altronix T2MK7F4D Trove Mercury kit is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power
supply/charger and sub-assemblies. T2MK7F4D kit also accommodates various combinations of Mercury boards for up to four (4) doors
in a single enclosure.
Configuration Chart:
Altronix
Model Number
120VAC
60Hz
Input
Current (A)
Power
Supply
Board
Input Fuse
Rating
Power
Supply
Board
Battery
Fuse Rating
Nominal DC
Output Voltage
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
Board
ACM4CB
Board
Input
Fuse
Rating
ACM4CB
Board
Output
PTC
Rating
PD8ULCB
Board
Output PTC
Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2MK7F4D
4.5
6.3A/
250V
15A/
32V
20.19-
26.4
20.19-
26.4
24VDC @ 9.2A 10A/32V 2A 2A
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws;
level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three
fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to
tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in
desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Mercury modules to backplane(s), refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB
and corresponding Sub-Assembly Installation Guides for ACM4CB and PD8ULCB for
further installation instructions.
Hardware:
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Snap On Standoff | 5/16” Pan Head Screw | Lock Nut
T2MK7F4D - 3 -
T2MK7F4D: Configuration of Mercury Boards:
1. Fasten snap on standoffs onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, MR52, MR16IN, MR16OUT
A
EP2500, MUX8
B
EP1501, MR51e
C
MR50
D
Fig. 2
Altronix
eFlow104NB
– DC +– BAT +
L G N
NC C NO NC
C NO
AC FAIL BAT FAIL
TRIGGER EOLNOGND
SUPERVISED RESET
+AUX-
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix
ACM4CB
RSB1 Rocker Switch
Altronix PD8ULCB
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
P N
R1
LED
B
B
AB
CC
CC
C
D
D
B
A
A
A
Fig. 2a
Snap On
Standoff
Mercury Board
Backplane
Pem
- 4 - T2MK7F4D
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIT2MK7F4D D10T
MEMBER
Trove2 Enclosure Dimensions (H x W x D approximate):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm)
19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm)
5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm)
2.00” (50.8mm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Altronix TROVE T2MK7F4D Installation guide

Type
Installation guide

Altronix TROVE T2MK7F4D is a fully assembled 4-door kit designed to provide secure and reliable access control for commercial and residential properties.

Here's a summary of its capabilities:

  • Complete Kit: Includes Trove2 enclosure, eFlow104NB power supply/charger, ACM4CB access power controller, PD8ULCB power distribution module, and rocker switch bracket.
  • Power and Access Control: Provides 120VAC input power and 6.3A/32V DC output current for powering access control boards and other devices.
  • PTC Protection: Features PTC (Positive Temperature Coefficient) outputs for protection against short circuits and overloads.

Ask a question and I''ll find the answer in the document