  • Hello! I am an AI chatbot trained to assist you with the Altronix Trove T2KHK3F12 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
T2KHK3F12
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKH2 Altronix/Kantech backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) T1618300K - Transformer
- One (1) ACM4 - Fused Access Power Controller
- One (1) ACM8 - Fused Access Power Controller
Access & Power Integration
Rev. 040819
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T2KHK3F12
Overview:
Altronix T2KHK3F12 Trove Kantech kit is pre-assembled and consists of Trove2KH2 enclosure/backplane with factory
installed Altronix power supply/charger and sub-assemblies. T2KHK3F12 kit also accommodates various combinations of
Kantech boards for up to twelve (12) doors in a single enclosure.
TKH2 accommodates a combination of the following Kantech boards:
Up to four (4) KT-MOD-INP16 or KT-MOD-OUTP16.
Up to four (4) KT300.
Up to three (3) KT400.
Configuration Chart:
Altronix
Model Number
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
120VAC 60Hz
Input Current (A)
Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply board
and ACM4/ACM8
Access Power
Controllers’outputs
Nominal DC Output
Voltage
Fail-Safe/Fail-Secure
or Dry Form “C”
Outputs
ACM4 Board
Input Fuse Rating
ACM4 Board
Output Fuse Rating
ACM8 Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2KHK3F12
5A/
250V
10A/
32V
3.5 24VDC @ 5.4A 20.17-26.4 20.28-26.4 12
10A/
250V
3A/
32V
10A/
250V
2.5A/
250V
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper
screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and
install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower
screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Kantech
boards to TKH2 backplane, refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and corresponding Sub-Assembly
Installation Guides for the following models: ACM8, ACM4 and T1618300K for further installation instructions.
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
T2KHK3F12 - 3 -
Altronix
T1618300K
NC C NO NC
C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOL NO GND
SUPERVISED RESET
+AUX-
- BAT +- DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix
eFlow6NB
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix
ACM4
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4
5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
ON
1 2 3 4
ON
Altronix
ACM8
A
B
C
C
C
C
B
B
B
A
A
Step 1a
Kantech
Standoff
Kantech
Board
Back of TKH2
Step 1b
Fig. 2a
Fig. 2
Configuration of Kantech Boards:
1. Align Kantech boards on the backplane to match the boards’ mounting holes with corresponding holes in backplane.
a. Position standoff over appropriate hole on the rear of backplane and depress it until it locks in place (Fig. 2a, pg. 3, Step 1a).
b. Depress down on board to secure it to the standoff (Fig. 2a, pg. 3, Step 1b).
2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided).
Kantech Access Controller Position Chart for the Following Models:
Kantech Board Pem Mounting
KT-400 Door Controller A
KT-300 Door Controller B
KT-MOD-INP16 or KT-MOD-OUTP16 Expansion Boards C
- 4 - T2KHK3F12
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)
G
1.25”
(31.75mm)
1.25”
(31.75mm)
6.25”
(158.75mm)
6.25”
(158.75mm)
6.75”
(171.45mm)
8.25”
(209.54mm)
8.00”
(203.2mm)
1.5”
(38.1mm)
1.25”
(31.75mm)
0.85”
(21.59mm)
0.85”
(21.59mm)
1.00”
(25.4mm)
2.00”
(50.8mm)
1.25”
(31.75mm)
2.00”
(
50.8mm
)
2.00”
(
50.8mm
)
5.25”
(
133.35mm
)
5.25”
(
133.35mm
)
7.00”
(
177.79mm
)
2.00”
(50.8mm)
2.00”
(50.8mm)
27.00”
(685.8mm)
3.50”
(88.9mm)
0.5625”
(14.29mm)
2.415”
(61.34mm)
0.685”
(17.399mm)
1.77”
(44.96mm)
3.50”
(88.9mm)
21.50”
(546.1mm)
19.80”
(502.92mm)
5.25”
(133.35mm)
5.25”
(133.35mm)
0.885” (22.479mm)
1.125” (28.32mm)
Knockouts
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIT2KHK3F12 K04S
MEMBER
/