Altronix ACM4 Datasheet

Category
Remote power controllers
Type
Datasheet

This manual is also suitable for

Altronix ACM4 is a versatile and reliable access control power controller designed to provide secure and efficient power management for various access control systems. With its ability to convert one 12 to 24-volt AC or DC input into four independently controlled outputs, the ACM4 offers flexible power distribution options. Additionally, the unit's support for both fail-safe and fail-secure modes ensures compatibility with a wide range of access control hardware, including mag locks, electric strikes, and magnetic door holders.

Altronix ACM4 is a versatile and reliable access control power controller designed to provide secure and efficient power management for various access control systems. With its ability to convert one 12 to 24-volt AC or DC input into four independently controlled outputs, the ACM4 offers flexible power distribution options. Additionally, the unit's support for both fail-safe and fail-secure modes ensures compatibility with a wide range of access control hardware, including mag locks, electric strikes, and magnetic door holders.

ACM4, ACM4E, ACM4CB and ACM4CBE
Multi-Output Access Power Controllers
Rev. DSACM4 - D07H
• Theseunitsconvertone(1)12to24voltACorDCinputintofour(4)
independentlycontrolledfusedorPTCprotectedoutputs.Thesepower
outputscanbeconvertedtodryform“C”contacts(ACM4&ACM4Eonly).
Outputsareactivatedbyanopencollectorsinkornormallyopen(NO)dry
triggerinputfromanAccessControlSystem,CardReader,Keypad,Push
Button,PIR,etc.Theunitswillroutepowertoavarietyofaccesscontrol
hardwaredevicesincludingMagLocks,ElectricStrikes,MagneticDoor
Holders,etc.OutputswilloperateinbothFail-Safeand/orFail-Secure
modes.Unitsaredesignedtobepoweredbyonecommonpowersource
whichwillprovidepowerforboththeboardoperationandlockingdevices,
ortwo(2)totallyindependentpowersources,one(1)providingpowerfor
boardoperationandtheotherforlock/accessorypower.TheFACPInter
faceenablesEmergencyEgress,AlarmMonitoring,ormaybeusedto
triggerotherauxiliarydevices.Therealarmdisconnectfeatureis
individuallyselectableforanyorallofthefour(4)outputs.
Overview
ACM4
• AccessPowerControllerw/fuse
protectedoutputs.
ACM4CB
• AccessPowerControllerw/PTC
protectedoutputs.
ACM4E
• ACM4w/enclosure.
ACM4CBE
• ACM4CBw/enclosure.
• 12to24voltACorDCoperation
(settingnotrequired),(.4amp@12volt,
.2amp@24voltcurrentconsumptionwithall
relaysenergized).
• Powersupplyinputoptions:
a)One(1)commonpowerinput
 (boardandlockpower).
b)Two(2)isolatedpowerinputs(one(1)for
 boardpowerandone(1)forlock/accessorypower).
• Four(4)AccessControlSystemtriggerinputs:
a) Four(4)normallyopen(NO)inputs.
b)Four(4)opencollectorsinkinputs.
c) Anycombinationoftheabove.
• Four(4)independentlycontrolledoutputs:
a) Four(4)Fail-Safeand/orFail-Secure
 poweroutputs.
b)Four(4)dryform“C”5ampratedrelayoutputs
 (ACM4/ACM4Eonly).
c) Anycombinationoftheabove
 (ACM4/ACM4Eonly).
• Four(4)auxiliarypoweroutputs(unswitched).
• Outputratings:
-Fusesarerated3ampeach(ACM4/ACM4E).
-PTCsarerated2.5ampeach(ACM4CB/ACM4CBE).
• Mainfuseisratedat10amp.
Note:Totaloutputcurrentisdeterminedbythe
powersupply,nottoexceedamaximum
of10amptotal.
• RedLEDsindicateoutputsaretriggered
(relaysenergized).
• FireAlarmdisconnect(latchingornon-latching)is
individuallyselectableforanyorallofthe
four(4)outputs.
FireAlarmdisconnectinputoptions:
a) Normallyopen(NO)ornormallyclosed(NC)
 drycontactinput.
b)PolarityreversalinputfromFACP
 signalingcircuit.
• FACPoutputrelay(form“C”contactrated@1amp
28VDCnotevaluatedbyUL).
• GreenLEDindicateswhenFACPdisconnect
istriggered.
• Removableterminalblocksfacilitateease
ofinstallation.
• Productweight(approximate):
- ACM4E:6.6lbs.
- ACM4CBE:6.7lbs.
• Shippingweight(approximate):
- ACM4E:7.5lbs.
- ACM4CBE:7.6lbs.
ACM4
ACM4E
Specifications
Board Dimensions (approximate)
ACM4/ACM4CB:5.125”Lx3.625”Wx1.25”H
Mounting Diagram
Board Dimensions (approximate)
ACM4E/ACM4CBE:8.5”Hx7.5”Wx3.5”D
AltronixCorp.-14058thStreet,Brooklyn,NY11220•718-567-8181•888-258-7669•altronix.com
0.14"
2.4"
4.9"
5.175"
3.37"
0.156"
0.19"
  • Page 1 1
  • Page 2 2

Altronix ACM4 Datasheet

Category
Remote power controllers
Type
Datasheet
This manual is also suitable for

Altronix ACM4 is a versatile and reliable access control power controller designed to provide secure and efficient power management for various access control systems. With its ability to convert one 12 to 24-volt AC or DC input into four independently controlled outputs, the ACM4 offers flexible power distribution options. Additionally, the unit's support for both fail-safe and fail-secure modes ensures compatibility with a wide range of access control hardware, including mag locks, electric strikes, and magnetic door holders.

Ask a question and I''ll find the answer in the document