TECHNICAL
BULLETIN
THERMAL DYNAMICS AUTOMATION TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-800-221-4401
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0005
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
Date: 07-18-08
Product: GCM 2000 and GCM 2010 By: Jorge Santana
Subject: 9-9409 Solenoid/Logic PCB
Summary: Incorrect Fuses Installed
Page 3 of 5
Fuse Locations and values
Location Description Value (Ohms) TDC internal part#
F1 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F2 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F3 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F4 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F5 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F6 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F7 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F8 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F9 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F10 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F11 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F12 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F13 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F14 0.250A, 250V, 5MM, 216 SERIES 2.7 21X516
F15 0.250A, 250V, 5MM, 216 SERIES 2.7 21X516
F16 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F17 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F18 1.6A, 250V, 5MM, 216 SERIES 0.2 (dead short) 21X517
F19 1A, 250V, 5MM, 216 SERIES 0.4 (dead short) 21X202
F20 1A, 250V, 5MM, 216 SERIES 0.4 (dead short) 21X202