ESAB GCM 2000 and GCM 2010 Troubleshooting instruction

Type
Troubleshooting instruction
TECHNICAL
BULLETIN
Date: 07-18-08
Product: GCM 2000 and GCM 2010 By: Jorge Santana
Subject: 9-9409 Solenoid/Logic PCB
Summary: Incorrect Fuses Installed
Page 1 of 5
THERMAL DYNAMICS AUTOMATION TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-800-221-4401
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0005
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
Valued Thermadyne Service Provider,
I has brought to our attention that our PCB supplier had sent some 9-9409 boards with the incorrect fuses
installed in it. The 9-9409 board is used on the GCM-2000 and GCM-2010
This issue will NOT compromise the integrity of the board itself or the GCM 2000 / GCM 2010 however,
the fuses in the board will open soon after the Gas Control Module is powered up.
We suspect that we began receiving the boards with the incorrect fuses within the last week of March.
The following pages include a simple procedure for the fuse verification and replacement. We recommend
to check your inventory accordingly on the following parts:
Part# Description
7-4000 GCM 2010
3-9131 GCM 2010 with TVA
9-9435 GCM 2000
3-9133 GCM 2000 with TVA
9-9409 Replacement Solenoid/Logic PCB
Please do not hesitate to contact us if you have any questions !
For More information Contact:
TECHNICAL
BULLETIN
THERMAL DYNAMICS AUTOMATION TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-800-221-4401
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0005
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
For More information Contact:
Date: 07-18-08
Product: GCM 2000 and GCM 2010 By: Jorge Santana
Subject: 9-9409 Solenoid/Logic PCB
Summary: Incorrect Fuses Installed
Page 2 of 5
1. Remove the cover from the Gas Console. Do not disconnect any connectors.
2. Use an ohmmeter to verify the value of the (20) fuses. Resistance of the fuses should be as follows:
Fuse ValueResistance Reading (Ohms)
0.125A …………………………… 4.1 – 4.7
0.250A ……………………………2.7
1A …………………………………0.4 (dead short)
1.6A ………………………….……0.2 (dead short)
TECHNICAL
BULLETIN
THERMAL DYNAMICS AUTOMATION TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-800-221-4401
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0005
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
Date: 07-18-08
Product: GCM 2000 and GCM 2010 By: Jorge Santana
Subject: 9-9409 Solenoid/Logic PCB
Summary: Incorrect Fuses Installed
Page 3 of 5
Fuse Locations and values
Location Description Value (Ohms) TDC internal part#
F1 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F2 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F3 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F4 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F5 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F6 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F7 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F8 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F9 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F10 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F11 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F12 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F13 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F14 0.250A, 250V, 5MM, 216 SERIES 2.7 21X516
F15 0.250A, 250V, 5MM, 216 SERIES 2.7 21X516
F16 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F17 0.125A, 250V, 5MM, 216 SERIES 4.1 – 4.7 21X201
F18 1.6A, 250V, 5MM, 216 SERIES 0.2 (dead short) 21X517
F19 1A, 250V, 5MM, 216 SERIES 0.4 (dead short) 21X202
F20 1A, 250V, 5MM, 216 SERIES 0.4 (dead short) 21X202
TECHNICAL
BULLETIN
Page 4 of 5
Solenoid/Logic PCB Layout
TECHNICAL
BULLETIN
THERMAL DYNAMICS AUTOMATION TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-800-221-4401
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0005
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
For More information Contact:
Date: 07-18-08
Product: GCM 2000 and GCM 2010 By: Jorge Santana
Subject: 9-9409 Solenoid/Logic PCB
Summary: Incorrect Fuses Installed
Page 5 of 5
Measure
resistance
3) If necessary to change a
fuse, be sure to use a fuse
puller so you don’t damage
the board or the fuse.
  • Page 1 1