ESAB CM 52 & CM 82 Troubleshooting instruction

Type
Troubleshooting instruction
TECHNICAL
BULLETIN
Date: 06/4/2008
Product: CM 52 & CM 82 By:John Brasseur
Subject: -2 Cat number
Summary: Release of 460V 3 phase Unit configuration
THERMAL DYNAMICS TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-603-298-7402
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0002
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
This Tech bulletin is intended to inform the Thermadyne sales force that the Cutmaster True series 52 and 82 can now be ordered in a 460V
3 phase configuration. These units will ship with a 3 phase 460V cable with out a plug.
The catalog numbers are:
1-5130-2 Cutmaster 52 20ft hand
1-5131-2 Cutmaster 52 50ft hand
1-5132-2 Cutmaster 52 25ft mech
1-5133-2 Cutmaster 52 50ft mech
1-1130-2 Cutmaster 82 20ft hand
1-1131-2 Cutmaster 82 50ft hand
1-1132-2 Cutmaster 82 25ft mech
1-1133-2 Cutmaster 82 50ft mech
Additional information in combating Hypertherm and Miller regarding the issue of having to remove the cover when changing the phase
of the machine. This is a direct quote from Hypertherms PowerMax1250 Manual on page 3-5:
For More information Contact:
CAUTION: When using the standard model power supply (CE model is 3PH only) with a
single-phase power source, replace the supplied power cord with a 6 AWG
(16mm
2
) 3-wire power cord. The power cord must be connected by a licensed
electrician.
TECHNICAL
BULLETIN
Date: 06/4/2008
Product: CM 52 & CM 82 By: John Brasseur
Subject: -2 Cat number
Summary: Release of 460V 3 phase Unit configuration
THERMAL DYNAMICS TECHNICAL SUPPORT
Phone: 1-800-752-7622
Fax: 1-603-298-7402
tdc-tech@thermadyne.com
www.thermadyne.com
Form 0002
82 Benning Street
West Lebanon, NH 03784
1-603-298-5711
Fax: 1-800-221-4401
“Exceeding Customer Expectations Through Performance Excellence"
For More information Contact:
SETUP
0
powermax1250 Operator Manual 3-5
CAUTION: When using the standard model power supply (CE model is 3PH only) with a
single-phase power source, replace the supplied power cord with a 6 AWG
(16mm
2
) 3-wire power cord. The power cord must be connected by a licensed
electrician.
Single Phase Power Cord (not for CE model)
Power Cord Installation
Strip and prepare the power cord wires as
shown below:
Plug Installation
The plug should be connected to the power cord by a licensed electrician.
L1
#10
Ground
L2
4 (102 mm)
7 (178 mm)
Route lead
through
strain relief
and tighten.
Power Switch
Ground
L1 & L2
  • Page 1 1
  • Page 2 2