5Kmstrup A/S • 5512937_C1_GB_05.2017
IP201
5 Instlltion
When supply hs been estblished, the Err nd Wink diodes re lit to indicte tht the module is
switched on. The Link diode lights/flshes if the RJ45 cble is mounted (communiction on the
network is indicted by flshes).
During strt-up, the Err nd Wink diodes re used for controlling the stte of the module:
1 Err nd Wink emit light constntly: The module hs just strted.
2 The Wink diode turns off when the module hs estblished connection to the network (vlid IP).
3 The Err diode strts flshing when the host is recognised (meter or concentrtor hve been
detected).
4 The Err diode turns off when the module hs been registered by the collecting server.
If the module cnnot connect to the meter nd/or server, IP201 will restrt.
Strt-up ACT/LINK WINK ERR
Power UP Off On On
LAN connection On/flsh - -
~3 sec (depending on DHCP srv), ~0 sec if sttic IP is used.
Vlid IP On/flsh Off On
15-20 sec.
Host recognised (meter/conc) On/flsh Off Flsh
20 sec (depending on AMR system).
Ack from server On/flsh Off Off
Ethernet connection ACT/LINK WINK ERR
No Ethernet Off – –
LAN OK – idle On – –
LAN OK –dt ctivity Flsh – –