SwitchX Evaluation Board Hardware User
Manual
PN: MT51336-EN-EVB, MT51336-VPI-EVB
Rev 1.0
Mellanox Technologies
350 Oakmead Parkway Suite 100
Sunnyvale, CA 94085
U.S.A.
www.mellanox.com
Tel: (408) 970-3400
Fax: (408) 970-3403
Mellanox Technologies, Ltd.
PO Box 586 Hermon Building
Yokneam 20692
Israel
Tel: +972-4-909-7200
Fax: +972-4-959-3245
© Copyright 2011. Mellanox Technologies. All rights reserved.
Mellanox®, BridgeX®, ConnectX®, CORE-Direct®, InfiniBridge®, InfiniHost®, InfiniScale®, PhyX®, Virtual Protocol Interconnect and
Voltaire are registered trademarks of Mellanox Technologies, Ltd.
FabricIT, MLNX-OS and SwitchX are trademarks of Mellanox Technologies, Ltd.
All other trademarks are property of their respective owners.
SwitchX Switch EVB Hardware User Manual
Document Number: 3493
Mellanox Technologies
2
NOTE:
THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTATION ARE PRO-
VIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF
AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUS-
TOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES
TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CAN-
NOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY.
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MER-
CHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT
SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEM-
PLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCURE-
MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED
DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
3
Pr
e
liminary
Dr
a
ft
Table of Contents
Revision 8
Chapter 1 Overview 9
1.1 Management CPU 9
1.2 PCIE/1GbE Extender Kit 10
1.2.1 PCIE Extender Kit 10
1.2.2 1GbE Extender Kit 10
1.3 Compliance Ports 11
1.4 Reference Traces 11
1.5 Features 12
1.6 Serial Number and Product Version Information 13
Chapter 2 40 Gb/s Ethernet 14
Chapter 3 FDR 15
Chapter 4 Basic Operation and Installation 16
4.1 Switch Platform Hardware Overview 16
4.1.1 Status LEDs 17
4.1.2 Reset Button 22
4.2 QSFP Cable Power Budget Classification 23
4.3 SFP+ Cable Power Budget Classification 23
4.4 Interfaces 23
4.4.1 Port Connector Interfaces 23
4.4.2 Management and Firmware Updating Interfaces 24
4.5 Switch Platform Installation and Operation 26
4.5.1 Installation Safety Warnings 26
4.5.2 Mechanical Installation 28
4.6 Package Contents and Installation 29
4.6.1 Installing the Switch in the Rack 29
4.6.2 Grounding the Switch 33
4.6.3 Power Connections and Initial Power On 34
4.6.4 Extracting and Inserting the Power Supply Unit 34
4.6.5 Cable Installation 36
4.6.6 Extracting and Inserting the Fan Unit 36
Chapter 5 Installing the PCIE/1GbE Server Side board 38
5.1 PCIE/1GbE Extender Kit parts 38
5.2 Removing the Top Cover 40
5.3 Removing the Management CPU 42
5.4 Installing the PCIE/1GbE Extender 43
5.5 Installing the Server Side Board 45
5.6 Board Connectors Numbering and Locations 46
5.7 Switch Shut Down Procedure 49
5.8 Disassembly of the Switch from the Rack 49
5.9 Disposal 50
5.10 Resetting the Switch 50
Chapter 6 Management and Tools Overview 51
6.1 Chassis Management Using the MLNX-OS Stack 51
6.2 Network Management and Clustering Software 51
6.3 Chassis Management 52
6.3.1 Open SM 52
6.4 Fabric Management with UFM 53
6.5 Configuring the Switch for the First Time 54
Chapter 7 Connecting to the Switch Platform 60
Rev 1.0
Mellanox Technologies
4
Pre
limin
a
r
y
D
raft
7.1 Starting an SSH Connection to the Switch (CLI) 60
7.2 Starting a WebUI Connection to the Switch 60
7.2.1 Managing the System 62
7.2.2 I2C Connector 62
7.2.3 How to Get Mellanox Firmware Tools (MFT) 62
7.3 Updating Firmware 63
Chapter 8 Troubleshooting 64
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
5
Pr
e
liminary
Dr
a
ft
List of Figures
Figure 1: Connector and Power Side Panels 9
Figure 2: Pull Out Tab 13
Figure 3: Connector and Power Side Panel 16
Figure 4: Power Side Panel 16
Figure 5: Power, Fan, and System LEDs 18
Figure 6: System Health LED 18
Figure 7: Power Side Panel 19
Figure 8: PSU Status LEDs 20
Figure 9: Fan Status LED Connector Side 20
Figure 10: Fan Status LED Power side 21
Figure 11: Reset Button 22
Figure 12: Port Numbering 23
Figure 13: Top and Bottom Ports 24
Figure 14: Management Interfaces 24
Figure 15: Rack Rail Kit Parts 30
Figure 16: Mounting Options 31
Figure 17: Screwing on the Rail 32
Figure 18: Inserting the Caged Nuts 32
Figure 19: Slide the Rail into the Rail Slide 33
Figure 20: Power Supply Unit Extraction 35
Figure 21: PSU Pulled Out 35
Figure 22: Top and Bottom Ports 36
Figure 23: Air Flow Labels 37
Figure 24: Fan Module Latches 37
Figure 25: Server Side Card 39
Figure 26: PCIE/1GbE Extender 40
Figure 27: Screw Locations 41
Figure 28: Slide the Top 41
Figure 29: Management Board Installed 42
Figure 30: Unscrew the Management Board 42
Figure 31: Remove the Management Board 43
Figure 32: Holes for the Extender Board Interfaces 43
Figure 33: Install the Extender Board 44
Figure 34: Connecting the EVB to the Server Side Board 45
Figure 35: EVB Board Connections View 1 46
Rev 1.0
Mellanox Technologies
6
Pre
limin
a
r
y
D
raft
Figure 36: Reset Button 50
Figure 37: Management Interfaces 54
Figure 38: Transfer Power Cord 71
Figure 39: Install the Power Cord Clip 72
Figure 40: Transfer Power Cord Finished 72
Figure 41: Connector Pinout 73
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
7
Pr
e
liminary
Dr
a
ft
List of Tables
Table 1: Revision History 8
Table 2: System Status LED Configurations 18
Table 3: Connector Physical and Logical Link Indications 19
Table 4: PSU Status LED Configurations 20
Table 5: Fan Status LED Configurations 21
Table 6: Bad Port LED Configurations 22
Table 7: Port Connector Numbering 47
Table 8: Serial Terminal Program Configuration 54
Table 9: Configuration Wizard Session - IP Configuration by DHCP 55
Table 10: Configuration Wizard Session - IP Zeroconf Configuration 57
Table 11: Configuration Wizard Session - Static IP Configuration 58
Table 12: Adapter Cards Certification Status 67
Table 13: Specifications for MT51336-NUDT 69
Table 14: Connector Pinout 73
Rev 1.0
Mellanox Technologies
8
Pre
limin
a
r
y
D
raft
Revision
Table 1 - Revision History
Revision Description
1.0 Initial Release
0.7 Added the correct H x W x D and weight
Added Power numbers
Added verified compliance port to use.
0.6 Added the word “Hardware” to the name.
Added correct graphics of the server side card
0.5 Added tie down the cables
Added Caution Note do not use as a shelf.
0.4 fixed graphics
0.3 More fixes
0.2 Added Initial configuration section
0.1 Preliminary Release
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
9
Pr
e
liminary
Dr
a
ft
1Overview
This EVB is intended to be used as a platform to evaluate the SwitchX silicon. SW engineers can
use it as a means for SW developement using the SwitxchX SDK. SW developers can implement
initial driver development/integration into non PPC CPU environments.
Signal integrity engineers can use it to evaluate SwitchX SI performance and compliance to spec.
This EVB can be used to:
evaluate and qualify
Ethernet SerDes
IB SerDes
FC SerDes
Initial Ethernet and IB switch testing for L2/L2+
This EVB can be used both while rack mounted (standard 19” rack) and in a tabletop setup(for
Signal Integrity evaluation).
Figure 1: Connector and Power Side Panels
1.1 Management CPU
The EVB comes with a Power PC 460E CPU for management. It also comes with a PCIE/1GbE
Extender that allows the user bypass the management CPU and to connect directly to the chip.
When the PCIE/1GbE Extender is used the Power PC is removed from the system
and none of the management interfaces on the connector side will work.
When the Power PC is removed the switch/ EVB becomes unmanaged and does
NOT need Initial configuration.
MT51336-EN-EVB
CONSOLE
MGT
RST
UID
PS1
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
35
36
33
34
1
2
4
3
Mellanox
!
!
OK
OK
!
!
OK
I2C
Overview
Rev 1.0
Mellanox Technologies
10
Pre
limin
a
r
y
D
raft
1.2 PCIE/1GbE Extender Kit
The Power PC management module can be removed and in its place a PCIE/1GbE extender can be
installed. When the Management module is removed the EVB becomes externally managed. The
PCIE/1GbE extender kit contains the system side board and the server side board.
The board has four connectors:
The server side board in the kit, gets inserted in a server. Connect the card into a 8X or 16X PCI
slot. This card has 3 ports:
1.2.1 PCIE Extender Kit
This option allows the EVB to be managed through the server. This is done with three cables con-
necting the EVB to the Server. One cable is for clocking and reset and two cables are for data TX
and RX.
1.2.2 1GbE Extender Kit
The PCIE extender allows for remote management through the 10/100/1000Mb RJ45 Ethernet
connection on the EVB Extender side board. This is connected to any standard Ethernet port fabric
management port.
Interface Description
CX4 connector for clocking and reset
2 QSFP connectors one is blue, one is green
The green one goes from the green labeled connector on the EVBduaghter board to the
green label on the server side card included in the kit.
The blue one goes from the blue labeled connector on the EVBduaghter board to the blue
label on the server side card included in the kit.
Server Side board a card that gets inserted into the server X8 PCI slot.
Use only one option the PCIE or the Ethernet, do not use both
RJ 45 connector for management through an ethernet port
Interface Description
CX4 connector for clocking and reset
2 QSFP connectors one is blue, one is green
The green one goes from the green labeled connector on the EVBduaghter board to the
green label on the server side card included in the kit.
The blue one goes from the blue labeled connector on the EVBduaghter board to the blue
label on the server side card included in the kit.
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
11
Pr
e
liminary
Dr
a
ft
1.3 Compliance Ports
Ports 3 and 4 and 33 and 34 are connected to the chip. These are compliance ports and go to the
SMA/mini-SMP interfaces. Ports 3 and 4 are SMA ports and ports 33 and34 are mini-SMP ports.
Compliance ports are the worst case loss (for all of the on board connectors) through the channel.
They are designed to have an insertion loss of 5.5dB as defined in SFF-8431.
See Figure 12 on page 23 for identifying the trace and compliance ports. See Figure 35 on page 46
and Table 7 on page 47 for locations and numbering of the trace and compliance port board con-
nections.
1.4 Reference Traces
Ports 1 and 2 and 35 and 36 are not connected to the chip. These are reference ports and go to the
SMA/mini-SMP interfaces. See Figure 35 on page 46 and Table 7 on page 47 For locations and
numbering of the board connections. Ports 1 and 2 are SMAports and ports 35 and36 are mini-
SMP ports.
These reference traces are designed to have identical insertion loss as the corresponding compli-
ance ports, and those traces are routed in the same geometry and length as the traces of the compli-
ance ports.
As of this revision only port 4 is verified at the proper designed insertion loss.
Use port 4 for compliance.
Overview
Rev 1.0
Mellanox Technologies
12
Pre
limin
a
r
y
D
raft
1.5 Features
Full Feature List
Reference traces SMA and mini-SMP
Compliance ports SMA and mini-SMP
2 ports connect to mini SMP connectors for SI testing
24 QSFP ports
1 PSU
12 SFP+ ports
RADIUS
TACACS+
LDAP
SSH
DHCP
•CLI
IPv6 MNG
•Telnet
FTP
RSTP
PFC
Static MAC
TFTP
•SCP
SNTP
AAA
•Syslog
•Dual SW image
Auto temprature control
Upload/download configuration
System alarms
VLAN aware
ETS
Flow Control
36 FDR (56Gb/s) ports in a 1U switch
IBTA 1.3 and 1.21 complaint
SDR/DDR/QDR/FDR10/FDR link speed
Congestion control
Adaptive routing
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
13
Pr
e
liminary
Dr
a
ft
Port mirroring
FDR10 supports 20% more bandwidth over regular QDR using the same cables/connectors**
Up to 8 multiple switch partitions*
All ports can be set to gateway ports connecting to 40GigE (over QSFP) or 1/10GigE (over
QSA)*
4.032 Tb/s aggregate data switching capacity with ultra low latency
CBF *
DCBX *
LAG/LACP *
QCN *
1.6 Serial Number and Product Version Information
The Serial number and GUID for the switch and the MAC for the Management PC are found on
the pull out tab below the USB interface connection.
Figure 2: Pull Out Tab
S/N: MT1117X00014
P/N: MT51336-EN-EVB
MAC: 0002C927051C
Made in IL
MGT 1:
00:02:C9:11:A2:01
MGT 2:
00:02:C9:11:A2:02
Rev:A1
40 Gb/s Ethernet
Rev 1.0
Mellanox Technologies
14
Pre
limin
a
r
y
D
raft
2 40 Gb/s Ethernet
Each QSFP port is capable of up to 40GigE and with a QSA the ports can run at 10GigE/1GigE.
Up to 24 QSFP ports are capable of 1/2/4/8G Fibre Channel with a QSA.
All ports are capable of virtual switching (VEPA+). All usable virtual switching ports are grouped
together.
The port protocol can only be obtained from the management interface.
40 Gb ETH is only guaranteed to work with approved Mellanox Cables.
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
15
Pr
e
liminary
Dr
a
ft
3FDR
The SwitchX EVB supports FDR, a pre-standard InfiniBand data rate, where each lane of a 4X
port runs a bit rate of 14.0625Gb/s with a 64b/66b encoding, resulting in an effective bandwidth of
54.54Gb/s. The FDR physical layer is an IBTA specified physical layer using different block
types, deskew mechanism and framing rules.
SwitchX™ also supports FDR10, a non-standard InfiniBand data rate, where each lane of a 4X
port runs a bit rate of 10.3125Gb/s with a 64b/66b encoding, resulting in an effective bandwidth of
40Gb/s.
FDR10 supports 20% more bandwidth over regular QDR using the same QSFP cables/connectors.
Both FDR and FDR10 support Forward Error Correction (FEC), as described in IEEE 802.3ap
chapter 74.
FDR10 is only guaranteed to work with approved Mellanox ConnectX-3 adapters.
Basic Operation and Installation
Rev 1.0
Mellanox Technologies
16
Pre
limin
a
r
y
D
raft
4 Basic Operation and Installation
4.1 Switch Platform Hardware Overview
Figure 4 shows the power side panel and connector side panel views of the switch EVB.
Figure 3: Connector and Power Side Panel
The figure shows port configurations for the switch systems, including:
2 – Ethernet RJ45 connectors
1 – RJ45 connector for connecting to a host PC (CONSOLE)
1 – USB connector
24 QSFP ports
12 SFP+ ports
various switch, port, fan and power status LEDs
Figure 4: Power Side Panel
1 – hot-swap fan module
1 – power supply unit
1 – I2C banana connector
various switch, port, fan and power status LEDs
All connectivity except for power cords is via the connector side panel. All connectors can support
active cables.
MT51336-EN-EVB
CONSOLE
MGT
RST
UID
PS1
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
35
36
33
34
1
2
4
3
Mellanox
!
!
OK
OK
!
!
OK
I2C
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
17
Pr
e
liminary
Dr
a
ft
4.1.1 Status LEDs
4.1.1.1 System Status Indicators
The System Status Indicators( ) are located to the left of the connectors on the connector side
panel, and on the power side at the far right. Both of these LEDs give identical information.
The system status indicators should display as follows:
When the switch is plugged in, within three minutes the STATUS LED should light up green.
The PSU LED should light up green.
The FAN LED should light up green.
If the FAN LED shows red, troubleshoot the fan module.
If the PSU LED is not green, this indicates a problem with the power supply. The switch is opera-
tional only if the PSU LED is green.
As long as there is power to the switch and the switch is booted up and running, the
status LED should be green.
If the STATUS LED shows red after three minutes, unplug the switch and call your
Mellanox representative for assistance.
If the switch shuts down due to over temperature, unplug the switch, wait 5 minutes
and replug in the switch. For more information See “Troubleshooting” on page 64.
OK
RST
UID
PS1
Power side
status LED
Connector side
status LED
Green – OK
Yellow – a fault in the sys-
tem
Red – Major Fault or
Fatal Error
Led Color shows the
switch status
Basic Operation and Installation
Rev 1.0
Mellanox Technologies
18
Pre
limin
a
r
y
D
raft
Figure 5: Power, Fan, and System LEDs
4.1.1.2 Power Side Panel System LED
On the right side of the power side panel is a single system LED that displays the health of the
switch. This indicator is the same as the system status indicator on the other side of the switch. The
LED assignment is as in Table 2.
Figure 6: System Health LED
4.1.1.3 Port Connector LED Assignment
Above the ports are two LEDs one for the upper port and one for the lower port . The fol-
lowing table shows the port status according to the LED indication.
Table 2 - System Status LED Configurations
LED Configuration STATUS/ System Health LED
Green OK – The system is up and running.
Flashing Green The system is booting up.
Yellow Error – A fault in the system, most likely
the firmware did not BOOT properly.
Red Major Error – Possible damage can result to the switch. Turn off immediately.
e.g. bad firmware, can’t boot, overheated
Off Off – The system has no power.
RST
UID
PS1
OK
This is a three color LED
Green — OK
Yellow — Fault in the system
Red — Major fault
SwitchX Switch EVB Hardware User Manual Rev 1.0
Mellanox Technologies
19
Pr
e
liminary
Dr
a
ft
4.1.1.4 Power Supply Status Indicators
The switch EVB is only available with one installed Power Supply Unit.
Figure 7: Power Side Panel
The power supply unit (PSU) is located on the right side of the power side panel. The PSU has a
single 2 color LED on the right side of the PSU, that indicates the internal status of the unit.
Table 3 - Connector Physical and Logical Link Indications
LED Status LED Description
Off No power to the port
Solid Green Logical link up
Flashing Green Data activity flashing speed data transfer speed
Orange Physical link up
Flashing Orange A problem with the physical link. Usually the SM is down or not enabling the port.
Mellanox
!
!
OK
OK
!
!
OK
I2C
Basic Operation and Installation
Rev 1.0
Mellanox Technologies
20
Pre
limin
a
r
y
D
raft
Figure 8: PSU Status LEDs
4.1.1.5 Fan Status Indicators
The indicator is located to the left of the connectors on the connector side panel.
Figure 9: Fan Status LED Connector Side
The LED indicator on the Fan Module is on the right side of the module.
Table 4 - PSU Status LED Configurations
LED Color Status
Green OK – The Power supply is delivering the correct voltage. 12VDC
Red Error – The PSU is not operational
Off Off – There is no power to the system .
!
OK
This is a two color LED
Green — OK
Red — Major fault
Off — No power to the system
Fan air flow indicator
RST
UID
PS1
This is a two color LED
Green — OK
Red — Major fault
Off — No power to the system
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

Mellanox Technologies MT51336-VPI-EVB User manual

Category
Chassis components
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI