1. Safety
Keep flammable m aterials away from the installation (such as curtains). A lot of energy is transferred into heat. Th e installation
should be such that the amount of air flow required for safe operation of the equipment is not compromised. Proper ventilation must
be provided.
Risk of electric sho ck / Risk of fire:
To protect against risk of fire caused by overloading of power c ables:
• MAXIMU M 4 tiles may be connected in parallel in case of 110-180 VAC, 50-60Hz. Eac h power source cable supplying ma ximum
4 tiles should be protected by a circuit breaker or fuses r ated 16 A / 250 VA C (15 A / 250 VAC in the USA and Canada).
• MAXIMU M 7 tiles may be connected in parallel in case of 180-240 VAC, 50-60Hz. Each power source cable supplying maximum
7 tiles should be protected by a circuit breaker or fuses r ated 16 A / 250 VA C (15 A / 250 VAC in the USA and Canada).
Note that one V4i series tile requires 100-240 VAC, 50-60 Hz.
Disconnect d evice:
When the appliance inlets of the individual tiles are not accessible, the sock et outlets s upplying the rack shall be installed near the
equipment and be easily accessible, or a readily acces sible general disconnect device shall be incorporated in the fixed wiring.
This equipm ent MUST be earthed:
In order to protect against risk of electric shock, the installation should be p roperly grounded. Defeating the purpose of the gr ounding
type plug will expose you to the risk of electric shock.
Power sys tem:
It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in or der to avoid large ground current loops due to voltage differences in the neutral c onductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and G round Fault
Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special attention
should be given to HD 60364, H armonization Document for electrical installation of buildings. In G erm any VDE 0100 should be
adhered to. In Americ a, special attention should be given to the N ational Electrical Code, A NSI/N FPA 70.
Mains cords:
The power cords delivered with this s ystem ha ve special properties for safety. They ar e not user serviceable. If the power cords are
damaged, replace them only with new ones. Never try to repair a power cord.
Data cables:
The data c ables provided with this system have special properties for safety. T hey are not user serviceable. If the data cables are
damaged, replace them only with new ones . Never try to repair a data cable. Pe r requirements of the National Electrical Co de®
in the USA , the length of a data cable must not exceed 42 m (140 feet). Avoid exposure of data cables to accidental contact with
lightning or power conductors.
1.4 Proper usage
Proper usage of V4i series tiles
• Shipping crates m ay be stacked to a max imum of 2 crates high.
• No part of the V4i series tile can com e in contact with any type of abras ive.
• No part of the V4i series tile c an com e in contact with any type of corrosive substance.
• V4i series tiles are to be used in environments meeting the operating specifications.
• V4i series tiles are not to be exposed to extreme localized heat or cold exceeding the temperature specifications.
• V4i series tiles are not to be exposed to any elem ent or situation that will cause any part of the display to heat beyond what
occurs d uring normal operation. Such s ituations include (but are not limited to) lasers, ultrasonic vibration, or any type of
substance that prevents proper ventilation and heat radiation of the V 4i series tiles.
• Power connected to the V4i series tiles must meet the specifications outlined in the installation manual.
• Never place a V4i series tile upon a surface with the LE Ds facing downwards. This to prevent damage to the LEDs and the
shaders.
• No force can be applied to the LEDs. Any LE Ds damaged due to m echanical stress are not covered by the warranty.
• Safety and functional features of the display c annot be defeated.
• Any failures mu st be immediately and appropriately dealt with. Failing equipment should not be left on a wall.
• Only Barc o cables specified to be used w ith the V 4i s
eries display are to be used to connect compon ents in an V4i series w all.
Furthermore, care must be taken to connect signals only according to the installation m anual.
• V4i series tiles are not to be us ed in the vicinity of any equipment that is not CE and UL/ETL certified.
• V4i series tiles are not to be connected to any non-Barco equipm ent.
• V4i series tiles can be cleaned only in accordance to the procedures defined in the installation m anual.
• The V4i series tile is equipped with two air filters. These filters must be replaced on a regular basis, depending on the environ-
ment conditions of the tile. It is recommende d to rep
lace the filters every 6 m onths or a shorter period, depending on the local
environment.
R5905981 V4I SERIES 20/07/2015