Danfoss KE07203 Ramped Valve Driver Installation guide

Type
Installation guide
.
Unit Specification
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763) 559-0108
ISSUE: 1 DATE: May 1993
KE07203
Ramped Valve Driver
GENERAL DESCRIPTION
This device is a ramped valve driver which accepts a setpoint potentiometer input from a control handle and drives a dual coil
proportional valve. It is pulse-width modulated and has adjustable acceleration/deceleration ramping. The threshold, full
stroke forward and full stroke reverse outputs are adjustable.
OUTPUT CHARACTERISTICS
SUPPLY VOLTAGE
24 Vdc
PWM FREQUENCY
100 Hz
OUTPUT CURRENT
0.7 A
FACTORY SETTINGS WITH 26 OHM LOAD
Threshold: 200 mA
Full Stroke 600 mA
DIMENSION AND CONNECTION DIAGRAM
1686
100,08
(3.94)
88,9
(3.50)
5,59 (0.22)
6,35 (0.25)
69,85 (2.75)
113,0 (4.45)
148,59 (5.85)
3,96 DIA (6)
(0.156)
THRESHOLD
FWD
F/S
REV
F/S
RAMP
TIME
20,32 
(0.8)
N/C
N/C
N/C
N/C
POT GND
GND
+24V POWER
OUTPUT - FWD
POT +8V
POT WIPER
LOAD CONTROL
OUTPUT - REV
WHEN USED WITH LOAD CONTROL, CONNECT LOAD CONTROL
OUTPUT TO TERMINAL 2 AND REMOVE JUMPER J4
1 2 3 4 5 6 7 8 9 10 11 12
.
.
Dimensions in millimeters (inches).
© Danfoss, 2013-09 K14424 UNIT SPEC 1
Phased Out Products
ADJUSTMENTS
TIME - SECONDS
0 1 2 3 4 5 6
25
50
75
100
R40 MAX CCW
R40 MAX CW
VALVE OUTPUT - %
1679
1680
Threshold adjustment.
1681
Full stroke adjustment.
INPUT VOLTS
0
0
OUTPUT CURRENT - mA
1 2 3 4 5 6 7 8
200
400
600
800
1000
FULL CW
R30
FACTORY
SETTING
FULL
CCW
FULL CW
R31
FACTORY
SETTING
FULL
CCW
INPUT VOLTS
0
0
OUTPUT CURRENT - mA
1 2 3 4 5 6 7 8
200
400
600
800
1000
FULL CW
R18
FACTORY
SETTING
FULL
CCW
FULL CW
R18
FACTORY
SETTING
FULL
CCW
2 K14424 UNIT SPEC © Danfoss, 2013-09