  • Hello! I am an AI chatbot trained to assist you with the Danfoss KE07201 Ramped Valve Driver Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
.
Unit Specification
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763) 559-0108
ISSUE: 1 DATE: May 1993
KE07201
Ramped Valve Driver
GENERAL DESCRIPTION
This device is a ramped valve driver which accepts a setpoint potentiometer input from a control handle and drives a dual coil
proportional valve. It is pulse-width modulated and has adjustable acceleration/deceleration ramping. The threshold, full
stroke forward and full stroke reverse outputs are adjustable.
It has a 12" pigtail with a 4-pin sealed Packard shroud connector for the power and output connections and a 12" pigtail with
3-pin (female) sealed Packard tower connector for the setpoint potentiometer connections. A bag assembly with mounting
hardware is shipped with the device. For mating connectors order bag assemblies K03384, 4-pin (female) tower connector
and K08630, 3-pin shroud connector.
.
.
DIMENSION AND CONNECTION DIAGRAM
1682
OUTPUT CHARACTERISTICS
SUPPLY VOLTAGE
24 Vdc
PWM FREQUENCY
100 Hz
OUTPUT CURRENT
0.7 A
FACTORY SETTINGS WITH 26 OHM LOAD
Threshold: 200 mA
Full Stroke 600 mA
REV
VALVE
COIL
FWD
VALVE
COIL
100,08
(3.94)
88,9
(3.50)
5,59 (0.22)
6,35 (0.25)
69,85 (2.75)
113,0 (4.45)
148,59 (5.85)
3,96 DIA (6)
(0.156)
THRESHOLD
FWD
F/S
REV
F/S
RAMP
TIME
POT WIPER
POT +8V
POT GND
OUTPUT – REV
OUTPUT – FWD
+24V POWER
GROUND
1K
OHM
20,32
(0.8)
Dimensions in millimeters (inches).
© Danfoss, 2013-09 K14422 UNIT SPEC 1
Phased Out Products
ADJUSTMENTS
TIME - SECONDS
0 1 2 3 4 5 6
25
50
75
100
R40 MAX CCW
R40 MAX CW
VALVE OUTPUT - %
1679
1680
Threshold adjustment.
1681
Full stroke adjustment.
INPUT VOLTS
0
0
OUTPUT CURRENT - mA
1 2 3 4 5 6 7 8
200
400
600
800
1000
FULL CW
R30
FACTORY
SETTING
FULL
CCW
FULL CW
R31
FACTORY
SETTING
FULL
CCW
INPUT VOLTS
0
0
OUTPUT CURRENT - mA
1 2 3 4 5 6 7 8
200
400
600
800
1000
FULL CW
R18
FACTORY
SETTING
FULL
CCW
FULL CW
R18
FACTORY
SETTING
FULL
CCW
2 K14422 UNIT SPEC © Danfoss, 2013-09
Phased Out Products
/