2. OPERATION FLOW
In this chapter, the purpose is to operate ABSODEX.
Functions are configured in the following way when the product is shipped from the factory.
Forced stop input (RYnC) : Valid
In case of no input, forced stop (servo-off) 7-segment LED
display 9.2.
Servo-on input (RYn9) : Valid
In case of no input, (servo-off) 7-segment LED display .. (dot)
When test operation is conducted without I/O cables connected, functions can be invalidated
temporarily, using the following communication commands.
To invalidate the forced stop input temporarily : L7M_23_2
To invalidate the servo-on input temporarily : L7M_52_999 (valid only in servo-off mode)
The state before change is restored after the control power is turned off then on again.
To invalidate the forced stop input temporarily, send the above-mentioned communication
command (L7M_23_2) and then perform alarm reset (send “S7”).
To invalidate the servo-on input temporarily, change to the servo-off mode first (by sending
“M5”), and then send the above-mentioned communication command (L7M_52_999).
Next, change to the automatic operation mode (by sending “M1”) and conduct test operation.
If you are not using the above functions, enter the following parameters.
Do not use the forced stop input: : L7_23_2
Do not use the servo-on input: : L7_52_1
The setting remains effective even after the control power is turned off then on again.
To invalidate the forced stop input, send the above-mentioned communication command
(L7_23_2) and then perform alarm reset (send “S7”) or turn the control power off then on
again.
Turn the control power off then on again to switch the servo-on input function.
After the function is switched, RYn9 is assigned to program stop input.
The 7-segment LED shows
(a dr and a dot) at the third digit and the second digit
from the right without an alarm.
The 7-segment LED (1st digit from the right) shows the operation mode.
For servo off,
(dr and two dots) will be displayed.