2-679-0706 Power Supply Monitoring Module
Installation Instructions
I-EA00143
Rev -, Rev Date: 01/09/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
The power supply monitoring module provides outputs to monitor Hager 2909
power supply status. A separate set of SPDT relay contacts are provided to
monitor AC power and DC output/battery status. Battery operation can be
monitored via the battery status contacts upon loos of AC power.
Attached one end of cable
supplied with the monitor module
to J1. Attach the other end to J6
on the power supply circuit board.
Attach LED cable from power
supply to J@ on monitor module.
YEL = SYSTEM OK
GRN = AC FAIL/NO DC
RED = BATTERY POWERED
OFF = SYSTEM OFF
NO BATTERY
[ POWER FAIL ]
D
5
[ BATTERY STATUS ]
NC COM NO NC COM NO
CABINET
DOOR
LED
J2
J1
PS
POWER SUPPLY MONITORING MODULE
SYSTEM
STATUS
Specifications
2 SPDT 1 amp relay outputs.
On/Off status.
Size: 3.25(83mm) W x 2.00(51mm) H.
Works with Hager 2909 Power Supply. Requires 1 Module space.
Supplied with mounting screws and standoffs for J-box mounting.
Page 1 of 1