Hagerco 2909 - 2A Modular Access Control Power Supply Installation guide

Type
Installation guide
2-679-0705 16 Amp Power Booster
Installation Instructions
I-EA00142
Rev -, Rev Date: 01/09/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
N/O
ACCESS
CONTROL
FAIL SECURE
LOCK 1
FAIL SECURE
LOCK 2
RELAY
Power Booster
1
2
6
5
4
3
2 1
POWER
INPUT
-
+
-
+
-
+
ELECTRICAL DATA
24vdc Input Voltage.
85mA Idle current draw.
Dry N/O trigger input ONLY.
2 Fail safe only outputs.
16A Surge output.
1A Continuous output.
Size: 3.25(83mm) W x 2.00(51mm) H.
Works with Hager 2909 Power Supply. Requires 1 Module space.
Supplied with mounting screws and standoffs for J-box mounting.
The Hager 2-679-0705 power booster is an
installer friendly module designed to work with
electronic devices that have a high surge current
draw such as the Hager 4500/4600 ELR Electric
Latch Retraction.
Operation
When N/O access control input is activated, the relay will
activate and send up to 16 amps inrush to either output.
If the access control input remains closed the power booster
can continue sending up to 1 amp to the load for operations
such as electric dogging.