Anova LEX70-C2T, LEX33-C2T, LEX45-C2T Installation guide

  • Hello! I'm a chat assistant knowledgeable about the installation of the Exposition Custom 2 Tone Receptacle. I've read the provided installation instructions, which details the required tools, hardware, and the step-by-step sequence for a successful installation. I am ready to answer your questions regarding the installation of this receptacle.
  • What kind of concrete footing is required?
    What hardware is needed for the installation?
    What is the recommended procedure for drilling holes for anchors?
Installation Instructions
Exposition Custom 2 Tone Receptacles
anovafurnishings.com
888.535.5005 tel
Step-by-Step Installation Sequence
The receptacle ships fully assembled and ready for use.
Examine the footing or slab for damage or defects. The footing or slab should be reinforced concrete rated at a
3,000 psi minimum and be cured for at least 28 days prior to the installation of the receptacle.
CAUTION: Oversized holes and holes drilled too deep in the concrete will make it dicult to set the anchor.
!
TOOLS NEEDED: HARDWARE NEEDED:
Hammer Drill
(2) 3/8" x 5"
Stainless Steel Stud Anchors
92188A203
Masonry Drill Bit Set
3/16" and 3/8"
Hammer
Pencil
9/16"Wrench
Wire Brush
Level
Safety Glasses
Optional: (2) 3/8"
Rubber Washers
90130A050
1
Installation Instructions
Step-by-Step Installation Sequence
1.
2.
3.
5.
4.
6.
7.
8.
Place receptacle in the desired location. Mark the location of the holes with a
pencil. To verify the alignment of the anchor markings you may reference the
"Foot Mount" image on page 1.
It is recommended that you start holes with smaller to the larger drill bits
in a sequential order. Begin with 3/16" diameter drill bit followed by the 3/8"
diameter bit to avoid oversized holes or holes drilled too deep."
Evacuate debris from mounting holes using compressed air and a steel wire
brush. This will create a clean environment for the anchor system.
Use the hammer to x the anchor into the drilled
hole by giving it several hammer blows.
Locate an anchor and adjust the nut so it is ush with the top of the anchor to
protect the threads from being damaged. Insert the anchor into the hole.
Repeat steps 3 - 6 until all anchors are installed.
Remove the nuts and washers o of the anchors.
Align the mounting holes of the receptacle over
top of the anchors and slide it down into place.
Care should be given to avoid rubbing the powder coating o the base. A 3/8" rubber washer is a suitable replacement option. Mount
the receptacle to the ground by fastening a washer and nut onto each anchor. Leave the hardware nger tight until all of them have been
installed. Verify that the receptacle is level before tightening the anchors. Tighten all of the hardware with a 9/16" wrench.
!
!
5
42
Exposition Custom 2 Tone Receptacles
2
7
8.28.1
3
11/13/2019 Copyright 2019 ANOV Manufactured in the U.S.
Note: Please contact Customer Care at 1-866-797-1761 when ordering replacement parts.
Installation Instructions
Exposition Custom 2 Tone Receptacles
FOOT MOUNTS:
LEX33-C2T
LEX45-C2T
LEX70-C2T
7)'8-32%%
796*%')13928
AA
1
1
2
2
3
3
4
4
A A
B B
THIRD ANGLE PROJECTION
TOLERANCES UNLESS NOTED:
X
1 X.X
.5 X.XX ± .25 X.XXX ± .125
X.XXXX ± .0625 X.XXXXX ± .03125
X.XXXXXX
.015625 ANGULAR ± 1°
ALL DIMENSIONS ARE IN INCHES AND ALL ANGLES
OR BENDS ARE 90 UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
PRINT IS FOR FABRICATION ONLY. ALL SURFACES
MAY EXPAND BY .125 .0625 DURING COATING.
211 North Lindbergh Blvd.
St. Louis, MO 63141
888.535.5005 tel
314.754.0835 fax
specify@anovafurnishings.com
anovafurnishings.com
DRAWN
45 Gallon Side Door Receptacle, Bonnet Top
SIZE
BLEX45_SPEC-REV-006
DATE
4/26/2013
SCALE
1:10
SHEET
DWG NO
TITLE
B. MENDEZ
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
ANOVA. DO NOT USE OR COPY WITHOUT WRITTEN PERMISSION.
THIS DRAWING IS CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND.
REV
1 OF
006
1
THIS DRAWING IS FOR PROTOTYPE OR TOOLING
USE ONLY. DO NOT USE FOR PRODUCTION.
REV DESCRIPTION ECN TR.# DATE
005 ADDED OPENING VIEW NONE 4/7/16
006 UPDATED TO CAMLOCK STYLE NONE 11/1/17
29.97"
26.25" 24.00"
22.00"
23.48"
22.36"
4.86"
7.83"
*6328:-);
7-():-);
37.44"
1
1.18"
20.58"
.412X "
1.31"
34.82"
43.95"
19.37"
7-():-);
*6328:-);
796*%')13928
A A
1
1
2
2
3
3
4
4
A A
B B
THIRD ANGLE PROJECTION
TOLERANCES UNLESS NOTED:
X
1 X.X
.5 X.XX ± .25 X.XXX ± .125
X.XXXX ± .0625 X.XXXXX ± .03125
X.XXXXXX
.015625 ANGULAR ± 1°
ALL DIMENSIONS ARE IN INCHES AND ALL ANGLES
OR BENDS ARE 90
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
PRINT IS FOR FABRICATION ONLY. ALL SURFACES
MAY EXPAND BY .125
.0625 DURING COATING.
211 North Lindbergh Blvd.
St. Louis, MO 63141
888.535.5005 tel
314.754.0835 fax
specify@anovafurnishings.com
anovafurnishings.com
DRAWN
LEX70 RECEPTACLE
SIZE
BLEX70_SPEC-REV-008
DATE 11/11/2013 SCALE
SHEET
DWG NO
TITLE
B. MENDEZ
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
ANOVA. DO NOT USE OR COPY WITHOUT WRITTEN PERMISSION.
THIS DRAWING IS CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND.
REV
1 OF
008
2
6): ()7'6-48-32 )'286 (%8)
834%2(796*%')13928:-);
%(()(232)
6)()7-+2)( 232)
%(()((-17 232)
94(%8)(83'%103'/78=0) 232)
238)7
31.50"
46.55"
40.00"
34.68"
39.51"
10.28"
4.40"
38.36"
22.53"
27.62"
16.00"
11.18"
11.10"
.412X "
11.10"
11.25"
16.00"
20.58"
9.25"
19.33"
2X Ø.39"
2X Ø.39"
2X Ø.39"
/