Anova AE2645RCT-LF Installation guide

Type
Installation guide
anovafurnishings.com
888.535.5005 tel
TOOLS NEEDED: HARDWARE NEEDED:
Installation Instructions
Step-by-Step Installation Sequence
!
Hammer Drill
Masonry Drill Bit Set
3/16", and 3/8"
Hammer
Pencil
9/16"Wrench
Wire Brush
Level
Safety Glasses
Product ships fully assembled.
Examine the footing or slab for damage or defects. The footing or slab should be reinforced concrete rated at a
4,000 psi minimum and be cured for at least 28 days prior to the installation of the receptacle.
CAUTION: Oversized holes and holes drilled too deep in the concrete will make it dicult to set the anchor.
Airi Receptacles
Optional: (2) 3/8"
Rubber Washers
90130A050
(2) 3/8" x 5" 18-8
Stainless Steel Stud Anchors
92188A203
% %
& &
THIRD ANGLE PROJECTION
TOLERANCES UNLESS NOTED:
X
1 X.X
.5 X.XX ± .25 X.XXX ± .125
X.XXXX ± .0625 X.XXXXX ± .03125
X.XXXXXX
.015625 ANGULAR ± 1°
ALL DIMENSIONS ARE IN INCHES AND ALL ANGLES
OR BENDS ARE 90 UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
PRINT IS FOR FABRICATION ONLY. ALL SURFACES
MAY EXPAND BY .125 .0625 DURING COATING.
211 North Lindbergh Blvd.
St. Louis, MO 63141
888.535.5005 tel
314.754.0835 fax
specify@anovafurnishings.com
anovafurnishings.com
DRAWN
Airi 45 Gal Receptacle/ Side Door & Canopy Top, Solid
SIZE
BAE2645CT
DATE 3/1/2016 SCALE
.09375:1 SHEET
DWG NO
TITLE
B. MENDEZ
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
ANOVA. DO NOT USE OR COPY WITHOUT WRITTEN PERMISSION.
THIS DRAWING IS CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND.
REV
1 OF
001
2
THIS DRAWING IS FOR PROTOTYPE OR TOOLING
USE ONLY. DO NOT USE FOR PRODUCTION.
REV DESCRIPTION ECN TR.# DATE
001 ORIGINAL PRINT NONE 3/1/16
*6328:-); 7-():-);
796*%')13928
40'
7
Ø.39"
(2 PLCS)
20.00"3.00"
11.00"
FOOT MOUNT FOR
45 GAL. RECEPTACLES
FOOT MOUNT FOR
33 GAL. RECEPTACLES
% %
& &
THIRD ANGLE PROJECTION
TOLERANCES UNLESS NOTED:
X
1 X.X
.5 X.XX ± .25 X.XXX ± .125
X.XXXX ± .0625 X.XXXXX ± .03125
X.XXXXXX
.015625 ANGULAR ± 1°
ALL DIMENSIONS ARE IN INCHES AND ALL ANGLES
OR BENDS ARE 90 UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
PRINT IS FOR FABRICATION ONLY. ALL SURFACES
MAY EXPAND BY .125 .0625 DURING COATING.
211 North Lindbergh Blvd.
St. Louis, MO 63141
888.535.5005 tel
314.754.0835 fax
specify@anovafurnishings.com
anovafurnishings.com
DRAWN
Airi 45 Gal Receptacle/ Side Door & Canopy Top, Solid
SIZE
BAE2645CT
DATE 3/1/2016 SCALE
.09375:1 SHEET
DWG NO
TITLE
B. MENDEZ
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
ANOVA. DO NOT USE OR COPY WITHOUT WRITTEN PERMISSION.
THIS DRAWING IS CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND.
REV
1 OF
001
2
THIS DRAWING IS FOR PROTOTYPE OR TOOLING
USE ONLY. DO NOT USE FOR PRODUCTION.
REV DESCRIPTION ECN TR.# DATE
001 ORIGINAL PRINT NONE 3/1/16
*6328:-); 7-():-);
796*%')13928
40
'7
Ø.39"
(2 PLCS)
16.50"3.00"
9.25"
Manufactured in the U.S.
Note: Please contact Customer Care at 1-866-797-1761 when ordering replacement parts.
Installation Instructions
Step-by-Step Installation Sequence
1.
2.
3.
4.
Place receptacle in the desired location. Mark the location of the holes with a
pencil. To verify the alignment of the anchor markings you may reference the
bottom of page 1.
Evacuate debris from mounting holes using compressed air and a steel wire
brush. This will create a clean environment for the anchor system.
!
2
5
4
Locate an anchor and adjust the nut so it is ush with the top of the anchor to
protect the threads from being damaged. Insert the anchor into the hole.
7
8.1
8.2
Copyright 2020 ANOV
Care should be given to avoid rubbing the powder coating o the foot.
A 3/8" rubber washer is a suitable replacement option. Mount the receptacle
to the ground by placing a washer and a nut onto each anchor. Leave the
hardware nger tight until all of them have been installed. Verify that the
receptacle is level before tightening the anchors. Tighten all of the hardware
with a 9/16" wrench.
5. Use the hammer to x the anchor into the drilled hole by giving it several
hammer blows.
6.
7.
Repeat steps 2 - 5 until all anchors are installed.
Remove the nuts and washers o of the anchors. Align the mounting holes of
the receptacle over top of the anchors and slide it down into place.
8.
!
1/20/2020
Airi Receptacles
It is recommended that you start holes in sequential order from the
smaller to the larger drill bits to avoid oversized holes or holes drilled too
deep. Begin with 3/16" diameter drill bit followed by the 3/8" diameter bit.
  • Page 1 1
  • Page 2 2

Anova AE2645RCT-LF Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document