  • Hello! I am an AI chatbot trained to assist you with the Focal Point ID+ 8" High Ceiling Downlight FL8H / L8-RD-DN Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
3b
id+ high ceiling 6"& 8" round
FL6H | FL8H
x4
key
power off power on
level attention
65/8min
63/4max
1
non-emergency
see additional instructions
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING.
ALL LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.
emergency - remote test switch
downlight wall wash
811/16min
87/8max
REMOVE ZIP TIE
PRIOR TO INSTALLATION
5x4
WALL
wall wash orientation
trim
fl6h fl8h
x2
6"8"
secure to structure aBove with 1/4 x 20
threaded rod or tiewire (By others)
GRID - 1/2" CONDUIT & CLIP (BY OTHERS)
X2
2
X2
3a
LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING
4
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4
Fixtures must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
DRYWALL
5X4
make electrical connections
8EMERGENCY
DO NOT MATE CONNECTOR
UNTIL INSTALLATION
IS COMPLETE AND A.C.
POWER IS SUPPLIED
CB
release
indicator
from Bracket
prior to
installation
(JBOX SIDE)
1.76"
Ø.166" (EDGE OF FLANGE TO CENTER OF HOLE)
8"
(JBOX SIDE)
2.80"
Ø.166"
(EDGE OF FLANGE TO CENTER OF HOLE)
6"
6
secure to structure aBove with 1/4 x 20
threaded rod or tiewire (By others)
234a X2
X2X2
1/2" conduit By others
4b
LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING
7
1/4" max
above ceiling
A
SEE BATTERY MANUFACTURER
INSTRUCTIONS
emergency maximum mounting height:
35.00'
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4
Fixtures must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
OPTIC ASSEMBLY
E
adjust indicator until
canopy is flush with ceiling
21
REMOVE TRIM
see trim removal ON
PAGE 5 OF INSTRUCTION SHEET
loosen thumB screw
3
4 5
REVERSE STEPS
FOR INSTALLATION
OF OPTIC
DRIVER SERVICE
loosen wingnut
21 REMOVE TRIM
see trim removal ON
PAGE 4 OF INSTRUCTION SHEET
STEPS 2-4 APPLY TO
ALL WALL WASH
& 6" DOWNLIGHT ONLY.
8" DOWNLIGHT SKIP TO STEP 5
3
RAISE HEAT SINK FOR CLEARANCE
11D
Contractor is responsible for adequately reinforcing walls and/or ceilings to support xture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or
ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4
5
DOWNLIGHT TRIM
2
13
center trim on led module
1 3
WALL WASH
2
WALL
WALL
tighten wingnut
4
DOWNLIGHT WALL WASH
1 1
TRIM REMOVAL DO NOT PULL ON TRIM FLANGE
/