Carel heaterSteam UR Series User manual

Type
User manual
High Efficiency Solutions
heaterSteam - UR
NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
Electric resistance humidifi er
User manual
3
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
WARNINGS
The humidi ers manufactured by CAREL Industries are advanced products,
whose operation is speci ed in the technical documentation supplied with
the product that can be downloaded, even prior to purchase, from the
website www.carel.com. Every product made by CAREL Industried, in relation
to its advanced level of technology, requires a quali cation/ con guration /
setup phse in order to best ful l your speci c application. The lack of such
phase of study, as indicated in the manual, can cause the  nal product to
malfunction, of which CAREL Industries cannot be held responsible. The
client (builder, developer or installer of the  nal equipment) assumes all
responsibility and risk relating to the con guration of the product in order to
achieve the expected results in relation to the speci c  nal installation and/
or equipping. In this case, subject to speci c agreements, CAREL Industries
acts as a consultant for the success of the installation / start-up / use of the
machine, but in no case does it accept liability for proper operation of the
humidi er and of the  nal plant, should the warnings and recommendations
in this manual or in any other technical documentation of the product not
be followed. In particular, in addition to the obligation to observe the above
mentioned warnings and recommendations for proper use of the product, we
recommend paying attention to the following warnings:
DANGER ELECTRIC SHOCK: The humidi er includes live electrical parts.
Disconnect the power supply before accessing internal parts, in case of
maintenance and during installation.
DANGER WATER LEAKS: The humidi er automatically and constantly  lls/
drains quantities of water. Malfunctions in the connections or humidi er may
cause leaks.
DANGER OF BURNS: The humidi er contains hot parts and delivers steam
at 100 °C / 212 °F.
The product is designed exclusively to humidify rooms either directly or
through distribution systems (ducts).
Installation, operation and maintenance must be performed by quali ed
personnel, aware of the necessary precautions and able to perform the
required operations correctly.
All operations on the product must be carried out according to the
instructions given in this manual and on the labels applied to the
product. Any uses or modi cations unauthorized by the manufacturer are
considered improper. CAREL Industries denies all responsibility for such
unauthorized uses.
Do not attempt to open the humidi er in any way other than the ones
described in the manual.
Follow all local regulations while installing the humidi er.
Keep the humidi er out of the reach of children and pets.
Do not install and use the product near objects that can be damaged
by contact with water (or condensate). CAREL Industries denies all
responsibility for direct or indirect damage as a result of loss of water from
the humidi er.
Do not use corrosive chemicals, aggressive solvents or detergents to clean
the internal or external parts of the humidi er, unless speci cally indicated
in the users manual.
CAREL Industries adopts a continuous development policy. Therefore, CAREL
reserves the right to carry out modi cations and improvements to any
product described in this document without prior notice. The technical data
in the manual can undergo modi cations without forewarning. The liability
of CAREL Industries in relation to its own product is governed by CAREL
Industries general contract conditions published on the website www.carel.
com and/or by speci c agreements with clients; in particular, within the limits
set by the applicable law, in no way will CAREL Industries, its employees or
its branch o ces/a liates be responsible for any lack of earnings or sales,
loss of data and information, cost of replacement goods or services, damage
to objects or persons, work interruptions, or any direct, indirect, accidental,
patrimonial, coverage, punitive, special or consequential damage in any way
caused, be they contractual, out-of-contract, or due to negligence or other
responsibility originating from the installation, use or inability of use of the
product, even if CAREL Industries or its branch o ces/a liates have been
warned of the possible damage.
ATTENTION
NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
Separate the probe cables and the digital input cables as much as possible
from the inductive load and power cables to prevent possible electro-
magnetic interference.
Never introduce power cables and signal cables (including those of electric
control board) into the same cable troughs.
The installation of the product must absolutely include the grounding
connection, using the special yellow-green terminal on the terminal block.
Do not use the neutral as grounding connection.
DISPOSAL
The humidi er consists of metal parts and plastic parts. With reference to the
European Parliament and Council Directive 2002/96/EC issued on 27 January
2003 and the related national implementation legislation, please note that:
1. WEEE cannot be disposed of as municipal waste, said waste must be
collected separately;
2. the public or private waste collection systems de ned by local legislation
must be used.
3. the equipment may contain hazardous substances: the improper use or
incorrect disposal of such may have negative e ects on human health
and on the environment;
4. the symbol (crossed-out wheeley bin) shown on the product or on the
packaging and on the instruction sheet indicates that the equipment has
been introduced onto the market after 13 August 2005 and that it must
be disposed of separately;
5. in the event of illegal disposal of electrical and electronic waste, the
penalties are speci ed by local waste disposal legislation.
Warranty for materials: 2 years (from the manufacture date, excluding
consumables).
Certi cation: the quality and safety of CAREL products are guaranteed by
CARELs ISO 9001 certi ed design and production system, as well as
marking.
5
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
Content
1. INTRODUCTION AND INSTALLATION 7
1.1 HeaterSteam (UR*)......................................................................................................7
1.2 Dimensions and weights ........................................................................................7
1.3 When opening the packaging ............................................................................7
1.4 Positioning .......................................................................................................................7
1.5 Wall mounting ..............................................................................................................7
1.6 Removing the front panel......................................................................................8
1.7 Mounting the front panel ......................................................................................8
1.8 Material supplied with the appliance .............................................................9
1.9 Technical data plate ...................................................................................................9
1.10 Hydraulic circuit ...........................................................................................................9
1.11 Structure of models UR002 – UR0013 .........................................................10
1.12 Structure of models UR020 – UR0080 .........................................................11
2. HYDRAULIC CONNECTIONS 12
2.1 Supply water ..............................................................................................................14
2.2 Drain water ...................................................................................................................14
3. STEAM DISTRIBUTION 15
3.1 CAREL jet distributors (SDPOEM00**) .........................................................15
3.2 Linear distributors for air pipes (DP***DR0) from CAREL .................15
3.3 CAREL ventilated steam distributors for rooms
(VSDU0A*, only models UR002...UR013) ....................................................16
3.4 Steam transport pipe .............................................................................................16
3.5 Condensate drain pipe .........................................................................................16
4. ELECTRICAL CONNECTIONS 18
4.1 Set up for power cables passageway ..........................................................18
4.2 Power supply cable connection .....................................................................18
4.3 Control board .............................................................................................................19
4.4 Steam production command signals ..........................................................20
4.5 Control with humidity probes ..........................................................................20
4.6 Alarm contact .............................................................................................................21
4.7 Final checks ..................................................................................................................21
5. SUPERVISOR NETWORK 22
5.1 RS 485 SUPERVISOR NETWORK .......................................................................22
6. PREPARING FOR OPERATION 22
6.1 Preliminary checks ...................................................................................................22
6.2 Removing the heating element centring spring
(only for three-phase models) ..........................................................................22
7. COMMISSIONING 23
7.1 Start ...................................................................................................................................23
7.2 Start-up sequence ...................................................................................................23
7.3 Autotest procedure .................................................................................................23
7.4 Shut down ....................................................................................................................24
7.5 User interface ..............................................................................................................24
7.6 Display .............................................................................................................................24
7.7 Keypad ............................................................................................................................25
7.8 Programming ..............................................................................................................25
7.9 Setting the set point (St) ......................................................................................25
7.10 Setting the adjusting and reading parameters; ....................................26
7.11 Modi cation of the con guration parameters ......................................26
7.12 Procedures ....................................................................................................................27
8. CONFIGURATION PARAMETERS 29
8.1 Parameter access and setting ...........................................................................29
8.2 Basic operation parameters ...............................................................................29
8.3 Auxiliary function parameters ..........................................................................29
8.4 Serial communication parameters ................................................................30
8.5 Control parameters .................................................................................................30
8.6 Measurement reading parameters ...............................................................30
9. ALARMS 31
9.1 Alarms table .................................................................................................................31
9.2 Autotest Retry procedure (Fault tolerance) ............................................33
9.3 Troubleshooting ......................................................................................................34
10. SPARE PARTS AND MAINTENANCE 35
10.1 Maintenance ...............................................................................................................39
10.2 Maintenance operations .....................................................................................39
10.3 Maintenance frequency .......................................................................................39
10.4 Maintenance of the cylinder-boiler ..............................................................39
10.5 Feeding/drain tempering solenoid valve .................................................41
10.6 Fill tray .............................................................................................................................41
10.7 Parts replacement ....................................................................................................41
10.8 Mechanical discharge of water in the cylinder .....................................43
10.9 Electrical connection of boiler heaters .......................................................44
11. WIRING DIAGRAMS 45
11.1 Wiring diagram UR002-UR004 single-phase 208 V ............................45
11.2 Wiring diagram UR002-UR004 single-phase 230 V ............................46
11.3 Wiring diagram UR006 single-phase 208 V ............................................47
11.4 Wiring diagram UR006 single-phase 230 V ............................................48
11.5 Wiring diagram UR006-UR010 (208-230-460-575 V) -
UR013 three-phase (230-460-575 V) ...........................................................49
11.6 Wiring diagram UR006-UR010-UR013 three-phase (400 V) .........50
11.7 Wiring diagram UR020-UR027 three-phase (208-230-460-575 V) .......51
11.8 Wiring diagram UR020-UR027 three-phase (400 V) ..........................52
11.9 Wiring diagram UR027 three-phase (230 V) ...........................................53
11.10 Wiring diagram UR040-UR053 three-phase (460-575 V) ................54
11.11 Wiring diagram UR040 - UR053 three-phase (400 V) .........................55
11.12 Wiring diagram UR053 three-phase (460 V) ...........................................56
11.13 Wiring diagram UR060 three-phase (575 V) ...........................................57
11.14 Wiring diagram UR060 (460-575 V) ...............................................................58
11.15 Wiring diagram UR060-UR080 three-phase (400 V) ..........................59
11.16 Wiring diagram UR080 three-phase (460-575 V) ................................60
12. GENERAL FEATURES AND MODELS 61
12.1 heaterSteam models and electrical features ..........................................61
12.2 Technical features ....................................................................................................62
12.3 Steam duct pipe models .....................................................................................62
12.4 Models of steam nozzles with concentrated jet ...................................62
12.5 Models of linear nozzles and typical installations ................................63
12.6 Table of parameter b1 ...........................................................................................64
12.7 Variables accessible in serial mode only ....................................................65
12.8 Production control via variables A52 and A53 .......................................66
13. ADVANCED FUNCTIONS 67
13.1 Operating principle .................................................................................................67
13.2 Regulation principles .............................................................................................67
13.3 Setting the alarm thresholds (type H or T control module) ..........68
13.4 Automatic total drain due to inactivity ......................................................68
13.5 User-adjustable duration of dilution drain ...............................................68
13.6 User-adjustable max. allowed no. of evaporation
cycles between 2 dilution drains ...................................................................69
13.7 Reduced  lls to restore water level after evaporation.......................69
13.8 PWM  lls after dilution and high-level/foam drains ...........................69
7
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
1. INTRODUCTION AND INSTALLATION
1.1 HeaterSteam (UR*)
Range of isothermal resistance humidi ers, equipped with LED display
for the control and distribution of steam.
Available models (identi ed by means of the code on the label, packaging
and on the technical data plate located inside the electrical cabinet):
UR002, UR004, UR006, UR010, UR013 with steam production capacity
up to 13 kg/h (28,66 lb/h), hydraulic connections under the base of
the humidi er;
UR020, UR027, UR040, UR053, UR060, UR080 with steam production
capacity from 20 to 80 kg/h (from 44.09 to 176.37 lb/h), hydraulic
connections next to the humidi er.
1.2 Dimensions and weights
Models UR002..UR013 Models UR020...UR080
B
A
C
B
A
C
Fig. 1.a
UR002…13 UR020…40 UR053…80
Size
mm (in)
A 365 (14,37) 690 (27,16) 876 (34,48)
B 275 (10.82) 445 (17,51) 445 (17,51)
C 712 (20,03) 888 (34,96) 888 (34,96)
Tab. 1.a
UR002…13 UR020…40 UR053…80
Weights
kg (lb)
packaged 31(68.3) 73(160.9) 98(216.0)
empty 26(57.3) 63(138.8) 87(191.8)
installed* 35(77.1) 97(213.8) 155(341.7)
Tab. 1.b
* in operating conditions,  lled with water.
1.3 When opening the packaging
check the integrity of the humidi er upon delivery and notify to the
carrier immediately, in writing, any damage that can be attributed to
improper or careless transport;
move the humidi er to the installation site before removing it from the
packaging, grasping the neck from beneath;
open the cardboard box, remove the protective material and remove
the humidi er, keeping it upright at all times.
1.4 Positioning
the unit is designed for wall mounting, suitable to support the weight
under operating conditions (see par. Wall mounting”). The models
UR020*... UR080 * can be  oor installed;
to ensure proper distribution of steam, place the humidi er next to the
steam distribution point;
place the humidi er horizontally (using a plumb and level), observing
the minimum clearances (see Figure 1b) to allow for necessary
maintenance.
Caution: during operation, the external metal panels heat up, and
the back leaning against the wall can reach temperatures above
60 °C (140 °F).
Models UR002..UR013 Models UR020...UR080
≥200
(7.9”)
≥200 (7.9”)
≥200
(7.9”)
≥400 (15.7”)
≥700
(27.6”)
<0,5$
≥500
(19.7”)
≥200 (7.9”)
≥300
(11.8”)
≥700
(27.6”)
Fig. 1.b
1.5 Wall mounting
Mount the humidi er on the wall using the support bracket pre-attached
to the humidi er, using the screws kit supplied (for mounting dimensions
see table below).
instructions for fastening:
1. unscrew the wall bracket from the one attached to the humidi er;
2. secure the bracket to the wall (see Fig. 1.c), checking for plumb and
level; if the unit is mounted on a masonry wall, you can use the plastic
anchor plugs (Ø 8 mm, Ø 0.31in) and the screws (Ø 5 mm x L= 50
mm, Ø 0.19 in x L= 1.97 in) supplied;
3. hang the humidi er on the bracket using the pro le on the upper
edge of the unit’s rear.
4. lock the humidi er to the wall by means of the hole / holes found /
on the lower part of the rear panel of the machine.
8
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
W
X
Y
Z
..2*.. - ..13*..
..20*.. - ..40*..
X
Z
W
..53*.. - ..80*..
J
K
piano di foratura
drilling template
X
X
Y
Z
Y
Fig. 1.c
Seize mm (in) UR002-13 UR020-40 UR053-80
X 220 (8.7) 445 (17.5) 286 (11.3)
Y 591 (23.3) 728 (28.7) 731 (28.8)
Z 82 (3.2) 22.5 (0.9) 137 (5.4)
W - 400 (15.7) 416 (16.4)
J - - 235 (9.3)
K - - 201 (7.9)
Tab. 1.c
1.6 Removing the front panel
Models UR002…UR013:
1
2
3
4
5
Fig. 1.d
1. turn the oval plate with the CAREL logo until the ground screw head
can be seen;
2. loosen the screw with a screwdriver;
3. grab the sides of the panel, lift it about 20 mm (0.79 in), and detach it
from the protruding edges of the humidi er;
4. remove the panel by pulling it forward;
5. remove the protective  lm.
Models UR020...UR080:
1
3
2
4
5
Fig. 1.e
1. remove the screws on the top of the humidi er using a screwdriver;
2. grab the panel by lifting it from the top about 20 mm (0.79 in);
3. remove the panel by pulling it forward;
4. remove the protective  lm (on all external surfaces of the humidi er).
1.7 Mounting the front panel
Models UR002…UR013:
1
3
4
2
Fig. 1.f
1. turn the red oval plate with the CAREL logo so that the fastening hole
below is visible;
2. slide the panel on the frame (keeping it slightly raised and tilted) until
it stops on the rear edges;
3. fasten the ground screw using a screwdriver, ensuring its tightening;
4. turn the red oval plate with the CAREL logo so that the fastening hole
below is no longer visible;
Models UR020...UR080:
1
2
Fig. 1.g
1. slide the panel on the base, keeping it slightly tilted;
2. put it in vertical position and tighten the screws on the top cover
with a screwdriver.
9
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
Caution: in models UR020...UR080 open the electrical
compartment of the humidi er using the slotted lock.
Fig. 1.h
1.8 Material supplied with the appliance
Once the packaging opened and the front panel removed, check
if there is a:
screws and anchor
kit for wall mounting
only for models UR020...UR080: Code
FWHDCV0003 back  ow prevention valve
with connection tube
1.9 Technical data plate
Humidi ers can be identi ed by means of the technical plate placed on
the partition wall of the electrical cabinet.
MOD.
A
Vac
Hz
PH
kW
kg/h
IP
Date
Part No.
IP
Date
Part No.
Serial No.
Rev.
MADE IN ITALY
CAREL INDUSTRIES
Via dell'Industria, 11, 35020 Brugine
(Padova) Italy
Fig. 1.i
Note: tampering, removal, lack of the identi cation plate or other
does not allow the safe identi cation of the product and will
make any installation or maintenance operation to be performed di cult.
1.10 Hydraulic circuit
Models UR002 – UR013
31 2
5
4
7
8
6
9
10
16
17
12
11
19
18
15
14
Fig. 1.j
Models UR020 – UR080
16
1
5
7
12
19
17
14
13
9
18
6
Fig. 1.k
1 Anti-foaming sensor 11 Drain tube tempering (*)
2 Over ll diaphragm 12 Drain valve tempering (*)
3 Fill diaphragm 13 Inlet valve
4 Feeding tank 14 Drain pump
5
Electrodes for conductivity meas-
urement
15 Anti-adhesive  lm (**)
6 Equaliser pipe 16 Overtemperature sensors (PTC)
7 Feeding pipe 17 Heaters
8 Fill-up pipe 18
Water temperature sensor (NTC)
(**)
9 Level sensor 19 Thermal insulation cover (**)
10 Over ow pipe
(*) for the units equipped with it
(**) for full option modules only
10
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
1.11 Structure of models UR002 – UR0013
!
drain
x 1000
Steam
Drain
Fill
Alarm
PRG
reset
SEL
I
26
22
21
20
19
18
17
16
14
13
7
8
5
3
2
1
B
10
15
9
6
4
C
A27
11
12
Key:
1 Solid state relay (SSR)
2 Safety module (Motor protector, THP)
3 Fuse-holder base (F1, F2)
4 CONTACTOR
5 Transformer
6 Control card
7 Power cable terminal block
8 Pump fuse (F3)
9 Anti-jamming  lter (where provided)
10 Cable gland for power cables
11 Fan control board
12 Cable gland for auxiliary circuit
13 Cooling fan
14 ON/OFF switch
15 Drain
16 Electronic controller
17 NTC probe holder
18 Water heater tank
19 Warning label
20 Level sensor
A Green LED: normal operation
B yellow LED: loading
C red LED: safety level
21 Locking belt
22 Heating element(s)
23 Drain pump
24 Infeed valve
25 Drain tempering valve (where provided)
26 Feeding tank
27 Thermal switch (klixon) SSR
26
22
25
24
23
Fig. 1.l
11
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
1.12 Structure of models UR020 – UR0080
drain
x 1000
Steam
Drain
Fill
Alarm
PRG
reset
SEL
I
25
1
24
23
22
21
20
19
18
17
15
14
13
11
10
9
8
7
6
5
4
3
16
12
2
26 27
Key:
1 Electronic controller
2 Thermal switch (klixon) SSR
3 Cooling fan
4 Solid state relay (SSR)
5 Heater fuse (where provided)
6 CONTACTOR
7 Safety module (Motor protector, THP)
8 NTC probe holder
9 Transformer
10 Control card
11 Fuse-holder base (F1, F2, F3)
12 Power cable terminal block
13 Anti-jamming  lter (where provided)
14 Power cable inlet
15 ON/OFF switch
16 Drain pump
17 Collection tray drain
18 Drain
19 Infeed valve
20 Drain tempering valve (where provided)
21 Drain tempering inlet (where provided)
22 Level sensor
23 Water heater tank
24 Drain pipe
25 Heating element(s)
26 Thermal switch (klixon) boiler
27 Anti-foaming sensor
28 Water  ll-up
29 Drain tempering water  ll-up (where provided)
29
28
18
17
Fig. 1.m
12
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
2. HYDRAULIC CONNECTIONS
Attention:before making the hydraulic connections disconnect
the humidi er from the power supply.
Models UR002..UR013 Models UR020...UR080
1
1
3
3
4
4 7
5
6
6
2
2
4
5
Fig. 2.a
HYDRAULIC CONNECTIONS:
1. install a manual valve upstream (to cut o the water supply);
2. connect the humidi er to the water supply. For UR002...UR013 models,
use a  exible pipe 3/4’’G connection. For UR020...UR080 models
connect the  exible pipe with the back ow prevention valve
(supplid - code FWHDCV0003), to avoid the water inside the
humidi er from making contact with the one in the mains;
3. install a mechanical  lter to retain any solid impurities (connect
before the inlet connection of the humidi er.
4. connect a section of pipe for draining (resistant to temperatures of
100 ° C (212 ° F)) and with a minimum internal diameter of 40 mm
(1.6 in) for models UR002-UR013 and 50 mm (2 in), for models UR020
UR080;
5. provide an open drain using a funnel to interrupt drain continuity;
6. connect a trap to prevent the return of odors;
7. for models UR020...UR080: connect a drain pipe from the drain pan
at the bottom of the humidi er (this can run into the funnel used for
draining).
8. for drain tempering versions, water temperature will be 60 °C (140 deg
F), so long as the temperature of the feed water is equal to or less than
25 °C (77 deg F) guaranteed.
Caution:
once the installation is complete,  ush the supply pipe for about
30 minutes by carrying water directly in the drain and without
introducing it into the humidi er. This will eliminate any waste or
processing residues that could clog the inlet valve and/or cause foam
when boiling water;
the drain pipe must run vertically downwards at least 30 cm (12 in)
( gure) to prevent the return of steam.
Set up for hydraulic connections:
Models UR002..UR013 Models UR020...UR080
B
A
A
D
B
C
Fig. 2.b Fig. 2.c
Key:
A Supply water inlet
B Drain water outlet
C bottom tank drain water outlet (only for models UR020-UR080)
D Drain tempering inlet (see explanation on chapter 12)
13
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
Hydraulic connections heights:
Drain / Fill
Models UR002…UR013 (view from below):
Fig. 2.d
mm (in)
D 75 (2.95) E 62 (2.44)
D’ 126 (4,96) E' 116 (4.57)
Water  ll Water  ll Water drain Water drain
Models UR020…UR080 (left side view):
L’
K
L
L”
I’
I
I”
J
Fig. 2.e
mm (in)
l 50 (1.96) L' 230 (9.0)
l' 120 (4.72) L” 54 (2.1)
l" 20 (0.78) J 132(5.2)
L 122 (4.8) K 571(22.5)
Water  ll Water  ll Water drain Water drain
Steam exhaust and condensate drain
Models UR002…UR013 (view from above):
A1
A2
A3
Fig. 2.f
seize mm (in) Models UR002-UR013
F 126.7 (5)
F' 224 (8.8)
G 137.9 (5.4)
G' 21.7 (0.85)
A1 Steam outlet
A2 Juncture for the steam distributor condensate drain pipe
A3 Fan head power cable passageway (ancillary)
Models UR020…UR080 (view from above):
B1
B2
PP
Fig. 2.g
seize mm (in) Models UR020...UR040 Models UR053-UR080
M 172 (6.8) 172 (6.8)
M' 31 (1.2) 52 (2.0)
N 273 (10.7) 260 (10.2)
N' --- 190 (7.4)
N" 46 (1.8) 52 (2.0)
P 60 (2.4) 60 (2.4)
B1 Set up for steam distributor condensate drain pipe
B2 Steam outlet
14
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
2.1 Supply water
The supply water for the electric resistance humidi er must not be
corrosive, must not emit bad odours, and must not contain too much
lime to avoid excessive deposits. The water, supplied from mains
of drinking water or demineralised water, must have the following
characteristics:
LIMIT VALUES FOR THE RESISTANCE HUMIDIFIERS WATERS
Resistances
Non-coated
Covered
with anti-ad-
hesive  lm
Min Max Min Max
Speci c conductivity at 20°C
/68°fH
σ20 - µS/cm 20 1500 1 1500
Total dissolved solids TDS – mg/l (1) (1) (1) (1)
Fixed residual at 180°C/ 356°fH TDS – mg/l (1) (1) (1) (1)
Hydrogen ion activity pH 6.5 8 6 8.5
Total hardness
TH– mg/l
CaCO3
0 (2) 400 0 400
Temporary hardness mg/l CaCO3 0 (3) 30 0 300
Chlorides ppm Cl = 20 = 50(4)
Iron + Manganese mg/l Fe+Mn = 0.2 = 0.2
Silica mg/l SIO2 = 20 = 20
Residual Chlorine mg/l Cl- = 0.2 = 0.2
Calcium sulphate mg/l CaSO4 = 100 = 100
Metallic impurities mg/l 0 0 0 0
Solvents, diluents, detergents,
lubricants
mg/l 0 0 0 0
Tab. 2.a
(1) Values depending on the speci c conductivity; in general: TDS ≈0,93 * σR, 20
°C; R180 ≈0,65 * σR , 20 °C;
(2) Not lower than 200% the content of chloride in mg/l Cl- ;
(3) Not lower than 300% the content of chloride in mg/l Cl- ;
(4) It could be necessary to intervene on the drain rate to avoid a concentration
in the boiling water higher than 300 mg/l Cl-.
Attention:treating the water with water softeners or
polyphosphates dispensers is not allowed; it allows for reduced
maintenance but favors the concentration of dissolved salts in the
water in the cylinder, leading to potential corrosion to the heating
elements and possible operation irregularities due to the formation of
foam. Should this be impossible to avoid, it requires dilution with
ordinary mains water in such a quantity as to guarantee at least 60% of
its initial hardness value, and not less than 5°f. Water treatment with
reverse osmosis demineralisers is allowed.
Not recommended:
1. the use of well water, industrial water or water from cooling circuits
and, in general, water which may be chemically or bacteriologically
contaminated;
2. the addition to the water of disinfectants or anticorrosion
compounds, as these may cause irritation.
Note: no relationship can be proven between water hardness
and conductivity; nonetheless, as an indication only, water with a
hardness of 40°f should have a conductivity of approximately 900-1000
mS/cm a 20 °C.
2.2 Drain water
contains the same substances dissolved in the supply water, but in
larger amounts;
it can reach a temperature of 100 °C (212° F);
it is not toxic and can be drained in the white waters collection
system.
for drain tempering versions, water temperature will be 60 °C (140 deg
F), so long as the temperature of the feed water is equal to or less than
25 °C (77 deg F) guaranteed.
Attention: completely demineralised water is aggressive. For
connection to a water system with fully demineralized water use
only installation items made of plastic resistant to chemicals (eg.
Polypropylene) or stainless steel.
15
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
3. STEAM DISTRIBUTION
3.1 CAREL jet distributors (SDPOEM00**)
They can be mounted either horizontally or vertically (steam exhaust
facing upwords).
See chapter 12 for distributors models.
Mounting instructions (see  gure):
1. drill a series of holes in the wall of the duct, using the drilling jig of
the distributor;
2. insert the distributor;
3. fasten the  ange of the distributor using 4 screws.
31,5
50 50
31,5
50
31,531,5
57,5
100
C
C
B
AA
B
D
Fig. 3.a
Key:
A. steam inlet
B. condensate drain
C.
steam outlet
The hole dimensions vary depending on the distributor model:
model SDPOEM0000: hole to be drilled manually,
up to 30 mm (1.2 in) diameter;
model SDPOEM0012: hole diameter 12 mm (0.5 in);
model SDPOEM0022: hole diameter 22 mm (0.9 in);
D. drilling jig
Note: if you use distributors steam with an inner diameter of 30
mm (1.2 in) remove the 22 mm (0.9 in) steam inlet section from the steam
distributor.
3.2 Linear distributors for air ducts
(DP***DR0) from CAREL
Install far from any obstacle (curves, rami cation, section changes, grilles,
lters, fans).
Minimum distance between distributor and obstacle: 1…1,5 m (3.3…4.9 ft).
Increase distance in case of:
1. increase in speed of the air in the duct;
2. turbulence decrease.
See paragraph 12.5 for installation examples.
Mounting instructions (see  gure):
drill a series of holes in the wall of the pipe, using the drilling jig of the
distributor (found in the packaging of the distributor);
insert the distributor with the steam outlet holes facing upwards;
fasten the  ange of the distributor using 4 screws.
B
Y
X
A
X
°2
L
5
4
3
2
1
9
6
8
Fig. 3.b
Key:
1. L-shaped mounting bracket (where applicable)
2. ange gasket
3. steam inlet (ØA)
4. condensate drain (ØB)
5. screw diameter (see instructions sheet that comes with the
distributor)
6. L = length (depending on the model of distributor, see paragraph
“Linear distributors” chap. 11)
7. tilt angle (about 2 °) for condensate drain
8. diameter of the hole in the wall (ØY)
Seize in mm (in)
linear distributors from CAREL
DP***D22R0 DP***D30R0 DP***D40R0
ØA 22 (0.9) 30 (1.2) 40 (1.6)
ØB 10 (0.4) 10 (0.4) 10 (0.4)
ØY 58 (2.3) 68 (2.7) 89 (3.5)
Ø 35 (1.4) 45 (1.8) 60 (2.4)
X 68 (2.7) 77 (3.0) 99 (3.9)
Tab. 3.a
Caution:
1. mount the distributor slightly tilted (at least 2°, to facilitate the
condensate discharge);
2. the L-shaped supports (see element 1 Fig. 3. b) is supplied with steam
distributors models from DP085* to DP025*. For shorter lengths the
bracket can be supplied as optional (code 18C478A088).
16
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
3.3 CAREL ventilated steam distributors for
rooms (VSDU0A*, only models UR002...
UR013)
Steam distributors for humidi ers up to 18 kg/h (39.7 lb/h). They can
be connected onto the humidi er or in a remote position (see  g. 3 c.)
These distributors have a power supply inside the electrical panel (24 Vac,
Terminals X1, X2).
A
B
C
D
E
F
G
Fig. 3.c
A > 0,5 m E > 0,5 m
B > 5 m F > 5 m
C > 2.1 m G > 1 m
D > 1 m
Caution: in order to achieve proper steam distribution observe
the distances indicated in the  g. above.
For the humidi ers larger than 18 kg/h, use ventilated steam distributors
code VRDXL00000 with 230 Vac power supply (maximum capacity 45
kg/h). The distributors are designed for installation in a remote position,
and require two steam hoses with a 30 mm diameter.
A > 0,9 m (>36”) E > 0,9 m (>36”)
B > 3 m (>120”) F > 3 m (>120”)
C > 1.8 m (>72”) G > 1.2 m (>48”)
D > 1.2 m (>48”)
3.4 Steam transport pipe
use CAREL  exible hoses (max 4 m long, see section “Models of steam
conducting pipes paragraph 12.2);
avoid the formation of pockets or traps (cause of condensate
accumulation)
avoid choking the pipe with sharp bends or twists.
Use metal clamps to fasten the ends of the pipe to the connections
on the humidi er and the steam distributor, so that they do not come
loose as a result of the temperature.
avoid strains which include mechanical stress on the cylinder steam
outlet tailpiece
3.5 Condensate drain pipe
During the operation of the humidi er some of the steam can condense,
causing e ciency loss and noise (gurgling).
To drain the condensate connect to the base of the distributor a discharge
pipe with a water trap and a minimum slope of 5° (see  g.).
CAREL condensate drain pipes: code 1312353APG.
Caution: the condensate drain pipe trap must be  lled with water
prior to turning on the humidi er.
Examples of correct and incorrect installation of the steam conduct pipe
and of the condensate drain pipe:
>5°
D> 200mm
>5°
R> 300mm
H ≤ 2 m
Fig. 3.d
All the UR models
>20°
>5°
D>200mm
R>300mm
1
Fig. 3.e
Models UR002...UR013 (1): connection with  ll tray
>20°
>5°
D>200mm
R>300mm
1
Fig. 3.f
17
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
Models UE020...UR080 (1) extend the pipe inide the humidi er up
to the base tank.
NO
Fig. 3.g
All the UR models
SI
R>300mm
R>300mm
D> 200mm
NO
NO
D> 200mm
Fig. 3.h
18
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
4. ELECTRICAL CONNECTIONS
4.1 Set up for power cables passageway
Models UR002-UR013
Exterior, view from below Interior, view from above
3
1
1
3
Fig. 4.a Fig. 4.b
Models UR20-UR80
Exterior, side view
1
3
2
Fig. 4.c
Key:
1. power supply cable inlet;
2. inlet (after drilling) for any other purpose;
3. probe cables inlet (after drilling).
4.2 Power supply cable connection
Before making the connections, ensure that the machine is disconnected
from the mains: set the master switch of the system and that of the
humidi er to OFF.
Attention: please note that the ON/OFF switch of the humidi er
cuts the power only to the electronic control, not the high
voltage, which remain powered.
Check that the voltage of the appliances power supply corresponds to
the value indicated on the data plate inside the electrical panel. Remove
the front panel as shown in chapter 1.
In order to insert the power cables and probes:
Models UR002-UR013
1. loosen the screws and remove the cover (A);
2. if necessary cut the top of the cone cable gland (B) and insert the
power cable;
3. connect the electrical cables to the terminal block, reinsert the cover
and fasten it with the screws;
To secure the probe cable:
4. remove the precut cable clamp (C) and loosen the screws;
5. insert the cable into the probe using the newly drilled hole: then
secure the cable with screws.
A
B
1
2
GND
L
N
3
Fig. 4.d Fig. 4.e
GND
L
N
C
4
GND
L
N
5
Fig. 4.f Fig. 4.g
Models UR020-UR080
1. Locate the grommet (A) on the right side of the appliance and pass
the power cable through it;
2. inside the electrical panel: unscrew the cable gland (B), connect the
wires to the terminal block and tighten the screws again to ensure
tightness.
GND
L1
L2
L3
B
A
Fig. 4.h
19
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
The power line to the humidi er must be  tted with a fused disconnect
protecting against short-circuits, to be mounted by the installer. The
table in chapter 12 shows the recommended cross-sections of the power
cable and the recommended sizes of the fuses; note, however, that this
data is purely indicative and, in the event of non-conformity with local
standards, the latter must prevail.
Note: in order to avoid unwanted interference, it is recommended
to keep the power cables separated from the signal ones from the
probes:
Caution: connect the yellow-green cable to the ground terminal
(GND).
4.3 Control board
The control board (S) is located inside the electrical panel, in the partition
wall.
UR002-UR013 UR020-UR080
S
S
Fig. 4.i Fig. 4.j
The auxiliary connections (probes, remote terminal, alarm), must be
made by introducing the external cables into the electrical panel. For this
purpose use the smaller fairlead on the base of the machine, passing the
cables through the raceway on the internal partition to the removable
screw terminals placed on the control board.
CONTROL BOARD
1I 2I 3I 4I 5I 6I
7I
8I
1K 2K 3K
1H 2H 3H
1E 2E 3E 4E 5E 6E
7E
8E
1J 2J 3J 4J
Main board
1G 2G
G H K I J
Key:
Terminal E: reserved;
Terminal G: reserved;
Terminal H: alarm contact
Terminal K: reserved
Terminals I: control signals
Terminals J: connection
with remote terminal or supervisory system
Fig. 4.k
terminal function electrical characteristics
1I humidity level probe signal input Input impedance:
50 k if set up for 0…20 mA or 4…10 mA
60 k if set up for 0…1 V or 0…10 V or 2…10 V
2I GND
3I ≈ 32 Vdc derived from rectifying of 24 Vac; max 250mA
4I 12 Vdc stabilised accuracy ± 5%; Imax=50 mA
5I
room probe signal input
or signal from external regulator
Input impedance:
50 k if set up for 0…20 mA or 4…10 mA
60 k if set up for 0…1 V or 0…10 V or 2…10 V
6I GND
7I
remote enabling Rmax=50 Ω; Vmax=24 Vdc; Imax=10 mAdc
8I
1H NO alarm contact
250 V; 8A with resistive load; 2A with indicative load2H common alarm contact
3H NC alarm contact
1G
Reserved
2G
1J ≈ 32 Vdc derived from rectifying of 24 Vac; max 250 mA
2J L +
standard RS485
3J L -
4J GND
1K
Reserved2K
3K
Tab. 4.a
20
ENG
“heaterSteam +0300075EN - rel. 1.2 - 29.09.2015
4.4 Steam production command signals
Attention: follow this sequence of steps in order to avoid
damaging the control board:
1. program the controller and turn it o ;
2. make the electrical connections;
3. switch the controller on.
The humidi er is  tted with solid-state relays, therefore its capacity
can vary from zero to 100% depending on the control requirements.
In addition, it can be connected by means of RS485 serial to a remote
supervisor. Depending on the type of signal used you can obtain
di erent types of enabling and/or management of the steam production
(ON/OFF or modulating). Production enabling is achieved by electrically
connecting the terminals 7I and 8I (jumper).
1. Steam production can be launched as follows:
HUMIDISTAT (ON/OFF):
connect the inputs 4l and 5l (production command) to a humidistat;
set parameter A0=0 to enable action ON/OFF
1I 2I 3I 4I 5I 6I
7I
8I
Fig. 4.l
Attention: prior to connecting the signal you must set the
parameters A0-A2-A6. See Paragraph 8.2.
HUMIDISTAT and REMOTE CONTACT (on/o )
connect the inputs 4l and 5l (production command) to a humidistat;
connect the inputs 7l, 8l (enabling) to a remote contact (e.g.: switch,
timer, ...);
set parameter A0=0 to enable action ON/OFF
1I 2I 3I 4I 5I 6I
7I
8I
Fig. 4.m
Attention: prior to connecting the signal you must set the
parameters A0-A2-A6. See Paragraph 8.2.
2. Enabling and adjusting steam production as follows:
EXTERNAL PROPORTIONAL REGULATOR (modulating action)
jumper connect inputs 7l, 8l;
connect outputs 5l, 6l (production command) to an external regulator;
set parameter A0=1 to enable the modulating action (see chapter 7)
and parameter A2 according to the signal chosen (0...1V, 0...10V, 2...10V,
0...20mA, 4...20mA).
1I 2I 3I 4I 5I 6I
7I
8I
OUT
REF
Fig. 4.n
Attention: prior to connecting the signal you must set the
parameters A0-A2-A6. See Paragraph 8.2.
EXTERNAL PROPORTIONAL REGULATOR and REMOTE CONTACT
(modulating action)
connect inputs 7l and 8l to a remote contact (enabling);
connect outputs 5l and 6l (production command) to an external
regulator;
set parameter A0=1 to enable the modulating action (see chapter 7)
and parameter A2 according to the signal chosen (0...1V, 0...10V, 2...10V,
0...20mA, 4...20mA).
1I 2I 3I 4I 5I 6I
7I
8I
OUT
REF
Fig. 4.o
Attention: prior to connecting the signal you must set the
parameters A0-A2-A6. See Paragraph 8.2.
Note: in the industrial sector (CEI EN61000-6-2) signal cables that
come out of the appliance must not exceed 30 m in length: steam
production signal cable (terminals 5I, 6I), the remote ON/OFF digital input
(terminals 7I, 8I) and shielded cable for RS485 communication.
4.5 Control with humidity probes
The main control board, connected to an environment humidity
control probe, adjusts the steam production according to the humidity
measured. You can connect a second humidity probe on the outlet: in
this con guration, typical of air treatment plants, the main control board
continues to adjust the steam production according to humidity, which
depends however on the value of the relative humidity measured in the
outlet duct.
HP HLP
Remote Contact
Fig. 4.p
Key:
HP
Environment humidity regulating probe (intake/environ-
ment humidity probe)
HLP Humidity limit probe (outlet humidity probe)
Remote Contact Remote contact
Attention: prior to connecting the signal you must set the
parameters A0-A2-A6. See Paragraph 8.2.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Carel heaterSteam UR Series User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI