SEAV LG 2234 User guide

Type
User guide

SEAV LG 2234 is an interface that allows you to control three-phase motors even if it has any 230 Vac Mono-phase control unit or via 230 Vac controls given by 2-way push button control. It has a power supply of 230/400V~ 50/60Hz and a motor output of 400V - 3kW Max. / 230V - 2.2kWMax. The control inputs are 230V~ 50/60Hz and the working temperature is -10÷55°C. It has an ABS UL94V-0 board support and the connection of the terminal board CN1 is 230-400V~ 50/60Hz Three-phase line input (R, S, T).

The SEAV LG 2234 is a

SEAV LG 2234 is an interface that allows you to control three-phase motors even if it has any 230 Vac Mono-phase control unit or via 230 Vac controls given by 2-way push button control. It has a power supply of 230/400V~ 50/60Hz and a motor output of 400V - 3kW Max. / 230V - 2.2kWMax. The control inputs are 230V~ 50/60Hz and the working temperature is -10÷55°C. It has an ABS UL94V-0 board support and the connection of the terminal board CN1 is 230-400V~ 50/60Hz Three-phase line input (R, S, T).

The SEAV LG 2234 is a

1 Rev. 1.2 03/12/10
I
NTERFACE FOR
LG
2234
THREE
-
PHASE MOTORS
The LG 2234 interface allows to control the 230 – 400 Vac three-phase motors even if it has any 230 Vac Mono-phase
control unit or via 230 Vac controls given by 2-way push button control ( Open-Close type).
T
ECHNICAL
F
EATURES
- Power supply: 230/400V~ 50/60Hz: 400V - 3kW Max. / 230V -
2.2kWMax.
- Motor output: 400V - 3kW Max. / 230V -
2.2kW Max.
- Control inputs: 230V~ 50/60Hz
- Working temperature: -10÷55°C
- Board support: ABS UL94V-0
C
ONNECTION OF THE
T
ERMINAL
B
OARD
CN1
1: 230-400V~ 50/60Hz Three-phase line input (R).
2: 230-400V~ 50/60Hz Three-phase line input (S).
3: 230-400V~ 50/60Hz Three-phase line input (T).
C
ONNECTION OF THE
T
ERMINAL
B
OARD
CN2
1: “Phase 230~ 50/60Hz” Opening Control Input (AP).
2: “Neutral 230~ 50/60Hz ” Common Control Input (COM).
3: “Phase 230~ 50/60Hz ” Closure Control Input (CH).
C
ONNECTION OF THE
T
ERMINAL
B
OARD
CN3
1: Earth Connection (Line).
2: Earth Connection (Engine).
C
ONNECTION OF THREE
T
ERMINAL
B
OARD
CN4
1: 230-400V~ 50/60Hz Three-phase Motor Outlet (U).
2: 230-400V~ 50/60Hz Three-phase Motor Outlet (V).
3: 230-400V~ 50/60Hz Three-phase Motor Outlet (W).
W
IRING DIAGRAM FOR
230/400V
T
HREE
-
PHASE
M
OTORS WITH
230
V
AC
M
ONO
-
PHASE CONTROL UNITS
GB
2 Rev. 1.2 03/12/10
W
IRING DIAGRAM FOR
230/400V
THREE
-
PHASE MOTORS WITH
230
V
AC
2-
WAY PUSH BUTTON CONTROL
W
IRING DIAGRAM FOR
M
OTORS IN
D.C
12/24
VDC
WITH
230
V
AC
M
ONO
-
PHASE CONTROL UNITS
3 Rev. 1.2 03/12/10
W
IRING
D
IAGRAM FOR
230V
MOTOR PHASE MOTORS WITH
230
V
AC
2-
WAY PUSH BUTTON CONTROL
F
OR THE INSTALLATION TECHNICIAN
IMPORTANT
The device does not have any circuit-breaking devices. The installer must therefore fit the system with a circuit-breaker. An
overvoltage category III single-pole switch should be installed. This should be installed in such a way as to be protected
against accidental reclosing.
Attention: this device is part of a more complex installation: the protective features of the device must therefore be valuated
and integrated in the final installation.
Attention
All of the operations that request the casing to be opened (cables connection, etc.) must be carried out in the installation phase by
expert staff. For any further operations that require the case to be opened again (repairs or installation modifications) contact the
after-sales assistance.
SEAV s.r.l. declares that the product:
LG2234
is in compliance with the specifications with the specifications of the EMC 2004/108/EC, LVD 2006/95/EC Directives.
  • Page 1 1
  • Page 2 2
  • Page 3 3

SEAV LG 2234 User guide

Type
User guide

SEAV LG 2234 is an interface that allows you to control three-phase motors even if it has any 230 Vac Mono-phase control unit or via 230 Vac controls given by 2-way push button control. It has a power supply of 230/400V~ 50/60Hz and a motor output of 400V - 3kW Max. / 230V - 2.2kWMax. The control inputs are 230V~ 50/60Hz and the working temperature is -10÷55°C. It has an ABS UL94V-0 board support and the connection of the terminal board CN1 is 230-400V~ 50/60Hz Three-phase line input (R, S, T).