Hubbell TD06032E Installation guide

Type
Installation guide

Hubbell TD06032E, a reliable tool for installing and tensioning guy strands, offers precise adjustment and secure holding. Its versatility allows usage on various guy strand sizes and types. With a minimum working tension of 10% of the guy strand's rated strength, it ensures efficient guy performance. The reusable components, except for rod subsets, enhance its cost-effectiveness. For towers exceeding 200 feet, a serving sleeve is recommended for added security.

Hubbell TD06032E, a reliable tool for installing and tensioning guy strands, offers precise adjustment and secure holding. Its versatility allows usage on various guy strand sizes and types. With a minimum working tension of 10% of the guy strand's rated strength, it ensures efficient guy performance. The reusable components, except for rod subsets, enhance its cost-effectiveness. For towers exceeding 200 feet, a serving sleeve is recommended for added security.

ADJUST-A-GRIP
®
INSTALLATION INSTRUCTIONS
2
Nomenclature of Adjust-A-Grip Deadend*
All catalog numbers have 4 rod subsets except Cat. No. 1270 AWA which has 5 subsets.
U-Bolt
Spacer Bar
Wedges
Socket
Load Nuts
Jam Nuts
Formed Color Code Ends
Rod Subsets
Pre-tension guy strand with
appropriate equipment. Be sure to
place the tensioning device high
enough on the guy strand to permit
installation of the rod subsets.
Remove the 2 jam nuts and 2 load nuts
and move the spacer bar to one side
of the U-Bolt to permit installation of
U-Bolt into termination hardware.
STEP 1 STEP 2
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
3
Cut the guy strand to the proper length. The cutoff point may be determined by sliding the
socket onto the U-Bolt to the desired location then marking the guy strand (Left). Be sure to
allow enough strand to extend at least two (2) inches beyond the end of the wedges (Right).
Slide the socket up the
guy strand with the larger
opening pointing toward
the U-Bolt. The socket can
be secured out of the way
temporarily.
STEP 3
STEP 4
STEP 2
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
4
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
Position the two wedge halves around the guy strand at least two (2) inches from the end (Left),
start the first rod subset by placing the color-coded end on the wedge. Allow the ends of the
rod subset to extend approximately
1
/
4
- inch beyond the edge of the wedge (Right).
Wrap the rod subset onto
the guy strand (Left). Note
that the subset holds the
wedges on the strand.
STEP 5
STEP 6
5
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
Complete the installation of rod subsets. Be sure the ends are snapped onto the guy strand
(Left). Note that the formed ends spread symmetrically over the wedge (Right).
Slide the socket down
onto the wedge and onto
U-Bolt. Tension to desired
load by tightening load nuts
alternatively so that the
socket is lined up square on
the U-Bolt. To insure guy
efficiency, normal working
tension should be at least
10% of the rated strength
of the Adjust-A-Grip AT
THE TIME OF TOWER
ERECTION.
STEP 7
STEP 8
6
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
After the desired tension is attained, tighten all jam nuts. This completes installation if the tower
height is less than 200 feet.
For towers 200 feet and taller, a serving sleeve must be used on rod ends. (See Step 10 below
and Recommendation 7 under Installation Recommendations on following page)
With larger end of serving sleeve
toward Adjust-A-Grip, use slot in
sleeve to place it on the guy strand
(Left). Slide sleeve over Adjust-A-
Grip rod ends and firmly seat it
(Right).
STEP 9
STEP 10
7
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
1. Chance
®
offers this guide only as an aid for installing Adjust-A-Grips. Your prescribed
company safety regulations and construction practices should be followed.
2. Chance
®
recommends that final guy tension of at least 10% of the guy strand rated strength
be maintained.
3. Use Adjust-A-Grips only on the size and type of guy strand for which they are designed and
listed in the catalog.
4. Guy tensions can be determined by the amount of torque applied to the load nuts. Consult
with Chance
®
for procedure.
5. Adjust-A-Grips should not be used as tools or come-a-longs.
6. Provided they are not damaged, the socket, wedge, U-Bolts, and nuts may be reused.
The rod subsets may be removed and reapplied twice within 90 days of initial installation,
provided they are not distorted or otherwise damaged.
7. If Adjust-A-Grip is used on towers 200 feet or taller, a serving sleeve also must be used to
help restrain rod ends.
INSTALLATION RECOMMENDATIONS
©Copyright 2014 Hubbell Incorporated | www.hubbellpowersystems.com | Adjust-A-Grip Installation
Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.
H ubb e ll P o we r S y st e ms ( H P S) m an u f ac tu r e s a wi d e v a ri e t y o f tr a ns m is s io n , di s tr ibu ti o n , s u bs t at io n , O E M , un d e rg r ou n d an d co m m un i ca ti o ns p ro d u ct s
used by utilities. HPS products are also used in the civil construction, transportation, gas and water industries. Our product line includes construction,
switching and protection products, hot line tools, insulators, arresters, pole line hardware, cable accessories, test equipment, transformer bushings,
connectors, grounding equipment and polymer precast enclosures and equipment pads.
TD_06_032_E
About Hubbell Power Systems:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Hubbell TD06032E Installation guide

Type
Installation guide

Hubbell TD06032E, a reliable tool for installing and tensioning guy strands, offers precise adjustment and secure holding. Its versatility allows usage on various guy strand sizes and types. With a minimum working tension of 10% of the guy strand's rated strength, it ensures efficient guy performance. The reusable components, except for rod subsets, enhance its cost-effectiveness. For towers exceeding 200 feet, a serving sleeve is recommended for added security.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI