Arena Luci ING0009-­WW User manual

Type
User manual
User'smanual
RecessedcarriageableLEDinground2out
This unit should only be used for purpose for
which it has been intended and should be
installed using the instructions which are
provided. Arena Luci cannot be held liable for
damages to person, animals or objects as a
result of improper, unreasonable and wrong
usage.
This instruction manual contains important
information about the installation and use of the
projector. Please read and follow these
instructionscarefully.
The security of this device is guaranteed only
with the proper use of the following instructions,
thereforetheymustbekeptcarefully.
Never install the device in locations easily
accessiblebypeoplewhoignoretheexistenceof
thisuser'smanualandsafetyinstructions.
For the wiring please refer to enclosed wiring
diagrams. If in the diagrams indicated there
shouldnotbethatofyourapplication,contactthe
technicaloffice.
Disconnecttheunitfromanypowersupplybefore
attemptinganyoperation incontactor insidethe
unit,andwhennotinuse.
Itisessentialthat electrical installation conforms
toallrelevantstandards.
Prior to connect the unit to the power supply,
check the output voltage fits the technical
requirementsonthelabel.
Neverletthepowercord come into contact with
othercables.
Nevertouchtheelectricalcontacts,eitherdirectly
withyourfingers,orindirectlybymeansofsharp
ormetalobjects.
Makesurethatcablescannotcausetriphazard.
Donotattempttodismantleandmodifytheunit.
Due to the high technological level of this unit,
anyservicemaintenanceshouldbeperformedby
specialisedoperators.PleasecontactyourArena
Lucidealerforanyoperation.
When assembling make sure that the cable
glandsaretightenedforawatertightseal.
Avoidinstallingtheunitclosetoheatsources.
Neverleanthepowercordonhotunitsurfaces.
Allowed to be mounted directly on inflammable
surfaces.
LEDmoduleisnotreplaceable.
Do not use any solvent based cleaning agents.
Useonlyasoft,dryantistaticcloth.
TheinstallationofLEDmodules(includingpower
supplies) should be done according to current
technical rules and regulations. The installation
shouldbeperformedonlybyaqualifiedoperator.
ThisluminaireisanoutdoorIP67device,butnot
IP68 (underwater). Therefore the proper and
extendedfunctioningwillberelatedtotheproper
installation.
To avoid infiltrations inside the inground box do
not open or install this luminaire during rainy
daysorinhighhumidityconditions.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
componentdefects.
WARNINGS
Please note that as part of Arena Luci's ongoing commitment to continuous product development,
specificationsaresubject to changein the courseofproduct improvement withoutnotice.Arena Luci isnot
responsiblefordamagesresultingfromimproperordifferentusethanexpected.
ING0009WW
ING0009W
2/4
ING0009
TRANSPORTANDSHIPPING
Opentheshippingcartonandverifythatallequip
mentnecessarytooperatethesystemhasarrived
intact. Refer to the following packing list for
information on what items are included with your
model. If any equipment is missing or damaged,
contactyourArenaLucidealerimmediately.
No.1LEDingroundING0009
No.1Recessedbox
No.1Torxscrewdriver
Before beginning initial setup of your LED
inground, make sure that there is no evident da
mage caused by transportation. In the event that
the unit’s housing is damaged, do not plug it in
and do not attempt to use it until after contacting
yourArenaLucidealerforassistance.
INSTALLINGTHEDEVICE
Before carrying out any operation, disconnect the
mainsvoltagefromthesystem.
Remove the two Torx screws and slide the LED
headoutoftherecessedbox.
Theinstallationcanbeperformedviatheincluded
dedicated inground/recessed box. It must be
positioned so that when the installation is
complete, the unit is at the same level of ground
surfaceorfloor:thatis,theuppersideofrecessed
boxshouldmatchthefinishedsurface.
Atheingroundboxmustbeplacedonalayerof
draining pebbles with a minimum thickness of
30cm in order to make easier the flow of rain
waterandavoidtheliftofmoistureinsidethebox.
Keepinmindthatattheendoftheinstallationthe
line joining the two fixing screws will be the
bisector between the two output windows. Orient
the inground box to direct the two light beams
where desired, otherwise when you will turn on
the LEDs the light beams will point in the wrong
direction.
Bthebottomlayeroftheinstallationshouldbema
dewithamaterialwithproperdrainingcapability.
C  the shunt from the 24 V DC line should be
performedusinganIP68ratedcastresinjoint.
Dtheconnectionbetweenthe24VDClineand
the supply cable of the luminaire should be
performed through the recessed box, using an
IP68ratedpowerconnection.Keepenoughcable
lengthformaintenancepurposes.
CompletetheinstallationbyclosingtheLEDheadon
topoftherecessedboxbytighteningthetwoscrews.
3/4
USER'SMANUAL
The fixture can be used either for indoor or
outdoor installations, thanks to the die cast alumi
nium body and the stainless steelAISI 316 head.
Theluminairecanbeinstalledeitherupsidedown
onceilings,oronsidewalls.
Ifyouwishtoinstallthefixtureonfalseceilingsor
on drywalls, you can install directly the unit
withouttheneedofrecessedbox.Itisyourjobto
ensure a stable fixing, depending on the type of
structureonwhichyouaregoingtoinstalltheunit.
POWERSUPPLY
Disconnectthemainsvoltagefromthesystem.
Connect the red line labeled with "+24V DC" to
the positive output of the power supply; connect
the black line to negative output of the power
supply.Payattentionnottoreversetheterminals:
a wrong polarity may seriously damage the devi
ce.Inthe caseofmultiple parallelconnectionsof
ingroundluminaires,itisrecommendedtouseca
bles with at least 2.5mm
2
cross section or larger,
accordingtothevoltagedropcalculations.
Also, the light can be dimmed using an external
optionalPWMdimmer(notincluded).Pleaserefer
to the instruction manual of the dimmer for
connection details. However, due to the internal
electronics,theregulationisnotsmoothandtakes
placeatdiscretelevels.
Whenchoosingtheproperpowersupplyunityou
have to consider the total power consumption of
all the devices connected in the same supplied
group;oncethisvalueisknown,itwillbepossible
tochooseamongthe vast range of powersupply
unitsofferedbyArenaLuci.
It is recommended to leave a margin of at least
the 25% less than the driving capability of the
supplyunit.
Connect the power supply to the mains outlet,
payingattentiontorightpolarityLNElabelledon
thewiringterminals(colours:brown=L,blue=N,
green/yellow = E). Check the output voltage is
compatiblewiththespecificationsof theinground
andtheoptionaldimmer.
Wiringdiagramtopowersupply
4/4
ING0009
ArenaLucisrl
viaSvizzera12/1446042CastelGoffredo(MN),Italy
Tel.+390376782411Fax+390376780973
www.arenaluci.com
WARRANTYCONDITIONS
The unit is guaranteed for 24 months from the
date of purchase against defects in workmanship
ormaterialsthatcomposeit.
This warranty does faults due to incorrect or
improperuseofthedevice.
The warranty is immediately void if the unit has
been tampered with or opened by unauthorized
personnel.
The warranty provides, at the discretion ofArena
Luci,repairorreplacementoffaultyequipment.
The serial number and model of the device are
required to obtain information or assistance from
the dealer. We invite you to transcribe them in
time: for any request of information or services,
thiswillresultinaquickandeffectiveoperation.
CERULES
The device meets the essential requirements of
the Directives
LVD
2014/35/UE,
EMC
2014/30/UE,
RAEE
2012/19/UE,
RoHS
2011/65/UE,
Ecodesign
2009/125/CE  reg. (UE)
1194/2012,
Energy label
2010/30/UE  reg. (UE)
874/2012  reg. (UE) 518/2014,
GPSD
2001/95/CE.
Warnings
DisposalofOldElectrical& ElectronicEquipment
(applicable in the European Union and other
European countries with separate collection
systems).
The product shall not be treated as
householdwastebutmustbehandedoverto
the applicable collection point for the
recycling of electrical and electronic
equipment. By ensuring this product is correctly
disposed, you will help prevent potential negative
consequences for the environment and human
health, which could otherwise be caused by
inappropriate waste handling. The recycling of
materialswillhelptoconservenaturalresources.For
more detailed information about recycling of this
product, please contact your city office, your
householdwastedisposalserviceoryoursupplier.
Powersupply
Powerconsumption
Lightsource
ColourTemperature
Carriageable
Beamangle
Socket
Material
Fixturecolour
Weight
Size
Insulationclass
Protection
Ambienttemperature
Suitabletobefittedonnormallyinflammablesurfaces
Appliedstandards
24VDC
3W
LED
3200K(WW)5500K(W)
2000kg
120°2outwindows
Cable2x1mm
2
,40cmlength
AISI316/Aluminium
Grey
750gLEDhead110gbox
Ø116x113mm(boxexcluded)
II
IP67
20°C...+40°C
TECHNICALSPECIFICATIONS
ING0009ENR0|07/2020