DMXDimmerPack6ch
User'sManual
10Ax6channelsdimmerpackwithdigitalDMX/analog010Vinputcontrolandpreheatfunction
CO670L
2/8
CO670L
This unit should only be used for purpose for
which it has been intended and should be
installed using the instructions which are
provided. Arena Luci cannot be held liable for
damages to person, animals or objects as a
result of improper, unreasonable and wrong
usage.
This instruction manual contains important
information about the installation and use of the
projector. Please read and follow these
instructionscarefully.
The security of this device is guaranteed only
with the proper use of the following instructions,
thereforetheymustbekeptcarefully.
Never install the device in locations easily
accessiblebypeoplewhoignoretheexistenceof
thisuser'smanualandsafetyinstructions.
Disconnecttheunitfromanypowersupplybefore
attempting any operation in contact or insidethe
unit,andwhennotinuse.
It is essential that each device is correctly
earthedandthatelectricalinstallationconformsto
all relevant standards. Never supply the unit
withouttheearthlink.
Prior to connect the unit to the mains supply,
check the output voltage fits the technical
requirementsonthelabel.
Never let the power cord come into contact with
othercables.
Nevertouchtheelectricalcontacts,eitherdirectly
withyour fingers,orindirectlybymeansof sharp
ormetalobjects.
Makesurethatcablescannotcausetriphazard.
Donotattempttodismantleandmodifytheunit.
Due to the high technological level of this unit,
anyservicemaintenanceshouldbeperformedby
specialisedoperators.PleasecontactyourArena
Lucidealerforanyoperation.
Alwaysensurethatthestructuretowhichyouare
attachingtheunitissecureandisabletosupport
theweightofeachunit.
Do not allow contact with water or any other
fluids,ormetallicobjects(IP20).
Do not install the projector in areas of high
humidity. The unit is intended only for indoor
purposes.
Avoidinstallingtheunitclosetoheatsources.
Neverleanthepowercordonhotunitsurfaces.
Not allowed to be mounted directly on
inflammablesurfaces.
Installtheunitwhereitcanbeeasilyaerated.
Avoidobstructionofin/outvents.
Maximumambienttemperature35°C.
If the unit is installed in a rack, then the
temperatureinsidetherackmustbebelow45°C.
RelativeHumiditybetween40%and80%.
Do not use any solvent based cleaning agents.
Useonlyasoft,dryantistaticcloth.
The installation should be performed only by a
qualifiedoperator.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
componentdefects.
WARNINGS
Please note that as part of Arena Luci's ongoing commitment to continuous product development,
specifications are subject to change in the course of product improvement without notice.Arena Luci is not
responsiblefordamagesresultingfromimproperordifferentusethanexpected.
3/8
USER'SMANUAL
BEFORESTARTING
Remove the product from the shipping carton,
checking that all the components supplied are
presentin the box. Refer tothe followingpacking
list to check which components must be present
in the packaging. If any component is missing or
damaged, contact your Arena Luci dealer
immediately.
n°1dimmerpackCO670L
Before starting the installation of your product
make sure that there are no evident damages
causedbytransportation.Intheeventthattheunit
isdamaged,donotplugitinanddonotattemptto
use it until you contacted yourArena Luci dealer
forassistance.
INTRODUCTION
This unit is intended to dim the following type of
fixtures: incandescent lamps, halogen lamps, low
voltagehalogenlampswithballast.
To ensure the normal total working hours of this
dimmer pack, please observe the following
suggestions.
If dimmer pack is installed in a rack, make sure
the rack has adequate ventilation. Otherwise the
unit will become overheat and will result in a
malfunction.
The maximum output current of each channel is
10A: this is a testing condition and must be held
for30minutesmaximum.
If the output current of each channel is less than
8A, the unit can work for several hours in
Theaters,StagesandStudios.
If the output current of each channel is less than
8A,theunitcanwork24/7withoutswitchingoffin
Hotels,Restaurants,Buildings.
This dimmer pack provides 6 dimming channels.
Each output channel has a 10A magnetic circuit
breaker.
Theunitisequippedwithathermalcontrolledfan.
When the temperature is over 45°C, the fan will
startautomatically.
Theautotrackingoffrequencyandphaseenables
stabledimmingoutputindifferentfrequencies.
The unit provides a testing function to perform
testswithoutconnectingtoaconsole.
Preheat function to protect the loads (Warmup
settingisfrom0%to6%).
FRONTPANEL
(1)Poweron/offswitch
(2)DMXIN/OUT(XLR5pin)
(3)DMXIN/OUT(RJ11,phonejack)
(4)LEDdisplay
(5)FunctionKeys
(6)Dimmingslidersofchannels16
(7)Analog010Vinput(9pin)
(8)Magneticcircuitbreakers
8 8
7
6
5
4
3 2 1
4/8
CO670L
REARPANEL/TERMINALBOARD
(9)DMXIN/OUT(XLR3pin)
(10)DMXIN/OUT(RJ11,phonejack)
(11)Outputterminalboard
(12)Powerinputterminalboard(20Aeachphase)
INSTALLINGTHEUNIT
Theunitmustbefixedonasuitablesupportwhich
remains stable during operation. Always make
suretherackorstructuretowhichyouaresetting
theunitissecureandisabletobeartheweightof
7kgofeachunit.
Disconnectthemainsvoltagefromthesystem.
Inthefollowingconnectiondiagrams you can find
how to connect to the mains voltage for both
ThreePhaseSystemandSinglePhaseSystem.
Respect the LNE polarity indicated on the
terminals(colorbrown=L1orL,black=L2,grey
=L3,blue=N,yellow/green=E).
It is essential that each unit is correctly earthed
and that electrical installation conforms to all the
standardsofgoodpracticeandsafetyregulations.
It is recommended that the unit is connected to
themainsviaapropercircuitbreaker.
Use the on/off switch to turn on and off the
dimmerpack.
9 10 11 11 11 12
5/8
USER'SMANUAL
CONNECTINGCONTROLSIGNALS
The dimmer pack, in order to be remotely
controlled, requires a digital signal DMX 512
(1990). The connection between controller and
dimmer pack and between dimmer pack and
dimmer pack must be made with twocore
shielded cable with a section of at least 0.5mm
2
and connectors model Canon XLR.The unit also
provides RJ11 connectors for DMX signal. In
carrying out the wiring of the connectors it is
important that the signal wires do not make
contact with each other and do not touch the
casingoftheplug.Thecasingoftheplugmustnot
be in contact with other objects possible sources
of disturbance. The three terminals have the
numbering referred to the poles of the XLR
connectors normally used for the connection of
theDMX:pin1=GNDorbraidedscreen,pin2=
DATA or cold pole, pin 3 = DATA + or hot pole.
6/8
CO670L
Pin 4 and pin 5 are not connected. For RJ11
plugs:pin1=+12V,pin2=DATA+,pin3=DATA
,pin4=GND.
Connect the signal coming from the controller to
the DMX socket of the unit labeled DMX IN.
Continue connecting the DMX OUTsocket to the
DMXINsocketofthenextunit.
TerminationoftheDMXsignal
For installations where the cable signal must
travellongdistancesor where there areelectrical
noises, for example a discotheque, it is
recommendedtouseaDMXterminator.TheDMX
terminator is simply an XLR connector with a
resistance of 120Ω (Ohm) between pins DATA
and DATA+. The connector is then plugged into
the DMX OUT socket on the last device in the
chain.
Analoginput
The dimmer pack can also be controlled via an
analog 010V dc control signal. The input socket
for this analog signal is located in the front panel
oftheunitandusesaDB9femaleconnector.
Thesix control values are connected to pins 1 to
6throughaDB9maleflyingconnector.
PROJECTORADDRESSES
The unit, to be remotely controlled, requires 6
DMXchannels.Eachdimmerpackmustbegiven
adigital start address number so that the correct
unit responds to the correct control signals. This
digital start address is the channel number from
whichtheunitstartsto“listen”tothedigitalcontrol
informationbeingsentoutfromthecontroller.This
digitalencodingmustbedoneoneachunit.
The start address of the coding is assigned by
setting the desired value using the display
interfaceonthefrontpanel.
Press and hold the DMX button on the keypad,
thenusethe▲or▼buttonstoselectthedesired
starting address (ie. dimmer 1 address 1 D.001,
dimmer2address7D.007,dimmer3address13
D.013,etc.); forfast forwardpress and hold the
button.
OPERATION
After supplying the device, the software performs
areset;attheendoftheelectronicsresetroutine,
thedisplayshowstheidlestate.
In the idle state the following informations are
shown:
d.001
d001isthebaseaddressofthedimmerpack.
. (blinking dot) indicates the presence of a valid
DMXsignal.
In the absence of DMX signal (XLR connector
unplugged),theblinkingdotisoff.
Set the base address of the unit as seen before
and connect the signal from DMX controller to
control the intensity of various lighting fixtures
connected.
7/8
USER'SMANUAL
Dimming/SwitchSetting
PressDMXbuttonintoDMXstatus.
PressandholdtheFNCbuttonfor3seconds.
The default setting for all channels (AL) is
dimmingmode(=d).
PressFNCbuttontoselectchannel.
Press ▲ or ▼ to select dimming mode (=d) or
switchmode(=S).
WarmUpSetting(0–6%)
Press FNC button. The default setting for all
channels(A)isnopreheat(00).
PressFNC button to select thechannel, ieselect
channel1
Press ▲ or ▼ to adjust. The warmup level can
beadjustedfrom1%to6%.
ChannelOutputStatusPreview
EntertoDMXstatusandpressDMXbutton.
Press▲or▼topreview.
ManualDimming
Move the sliders VR1VR6 to dim the intensity of
thecorrespondingoutputchannel.
When a DMX signal input from a console is also
present, the corresponding output channel will
take the higher value between DMX signal and
slidervalue.
WhenthedimmerpackisreceivingaDMXframe,
if the signal is lost (or the cable is disconnected)
theoutputswilltakethevaluesetbythesliders.
Also, if the projector is turned on and it is not
connectedtoavalidDMXsignal,thelightintensity
isbroughttothelevelssetbythesliders.
Display the Dimming Value of DMX Channel
andInternalTemperature
Press L button to display the dimming value of
DMXchannel.
PressTbuttontodisplaytheinternaltemperature.
DMX512Status&DMX512Address
PressDMXbuttontoDMXstatus.
The LED will return to DMX status after 10
minutesidle.
ProtocolControl
When the protocol control turns on, it only
receives the DMX signal whose break width
rangesfrom88μsto230μs.
Press FNC button to enable or disable the
protocolcontrol.
Press ▲ and LED displays as below, protocol
controlisON.
Press ▼ and LED displays as below, protocol
controlisOFF.
8/8
CO670L
WARRANTYCONDITIONS
Theunitisguaranteedfor24monthsfromthedate
of purchase against defects in workmanship or
materialsthatcomposeit.
This warranty does faults due to incorrect or
improperuseofthedevice.
The warranty is immediately void if the unit has
been tampered with or opened by unauthorized
personnel.
The warranty provides, at the discretion of Arena
Luci,repairorreplacementoffaultyequipment.
The serial number and model of the device are
requiredtoobtaininformationorassistancefromthe
dealer.Weinviteyoutotranscribe themintime: for
anyrequestofinformationorservices,thiswillresult
inaquickandeffectiveoperation.
CERULES
Thedevicemeetstheessentialrequirementsofthe
Directives LVD 2014/35/UE, EMC 2014/30/UE,
RAEE 2012/19/UE, RoHS 2011/65/UE, Ecodesign
2009/125/CE  reg. (UE) 1194/2012, Energy label
2010/30/UE  reg. (UE) 874/2012  reg. (UE)
518/2014,GPSD2001/95/CE.
Warnings
Disposal of Old Electrical & Electronic Equipment
(applicable in the European Union and other
European countries with separate collection
systems).
Theproductshallnotbetreatedashousehold
waste but must be handed over to the
applicable collection point for the recycling of
electrical and electronic equipment. By
ensuringthisproductiscorrectlydisposed,youwillhelp
prevent potential negative consequences for the
environment andhumanhealth, whichcouldotherwise
be caused by inappropriate waste handling. The
recycling of materials will help to conserve natural
resources. For more detailed information about
recyclingofthisproduct,pleasecontactyourcityoffice,
yourhouseholdwastedisposalserviceoryoursupplier.
ArenaLucisrlviaSvizzera12/1446042CastelGoffredo(MN),Italy
Tel.+390376782411Fax+390376780973
www.arenaluci.com[email protected]t
Powersupply
Outputcurrent
Control
Control
Channels
Connection
Material
Colour
Insulationclass
Weight
Dimensions
Protection
AmbientTemperature
Notallowedtobefittedonnormallyinflammablesurfaces
Appliedstandards
90÷240VAC4563Hz
10Amaxeachchannel
StandardDMX512/1990controlsignal,6controlchannels
ConnectorXLR5pinIN/OUT(front)ConnectorXLR3pinIN/OUT(rear)
ConnectorRJ116p4cphonejackIN/OUT(front+rear)
AnalogsignalDC010V,6controlchannels
ConnectorDtypeplug9pinFemale
6independent,phasecutdimming,230Vacoutputs
Terminalblocks,inputandoutput
Aluminiumandsteelplate
Epoxypowderpaintfinish,black
I
7kg
482x88x300mmStandardrack19"2U
IP20
FromCto+35°C
TECHNICALSPECIFICATION
CO670LENR0|07/2018
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Arena Luci CO670L User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI