Arena Luci Design LL0291­-W User manual

Type
User manual
LL0291W
LL0291RGB
This unit should only be used for purpose for
which it has been intended and should be
installed using the instructions which are
provided. Arena Luci cannot be held liable for
damages to person, animals or objects as a
result of improper, unreasonable and wrong
usage.
This instruction manual contains important
information about the installation and use of the
projector. Please read and follow these
instructionscarefully.
The security of this device is guaranteed only
with the proper use of the following instructions,
thereforetheymustbekeptcarefully.
Never install the device in locations easily
accessiblebypeoplewhoignoretheexistenceof
thisuser'smanualandsafetyinstructions.
For the wiring please refer to enclosed wiring
diagrams. If in the diagrams indicated there
shouldnotbethatofyourapplication,contactthe
technicaloffice.
The device is intended exclusively for a
submergedinstallation.
Disconnecttheunitfromanypowersupplybefore
attempting any operation in contact or insidethe
unit,andwhennotinuse.
It is essential that electrical installation conforms
toallrelevantstandards.
When assembling make sure that the cable
glandsaretightenedforawatertightseal.
Thedevicecannotbeinstalledatadepthgreater
than0.5meters.
The lamp is intended only for underwater
operation.Donotswitchonthelampoutsidethe
waterformorethan10seconds.
Never install the device in areas where there is
no constant water flow; the maximum
temperaturemustbebelow40°C.
Prior to connect the unit to the mains supply,
check the output voltage fits the technical
requirementsonthelabel.
Never let the power cord come into contact with
othercables.
Nevertouchtheelectricalcontacts,eitherdirectly
withyour fingers,orindirectlybymeansof sharp
ormetalobjects.
Makesurethatcablescannotcausetriphazard.
Donotattempttodismantleandmodifytheunit.
Due to the high technological level of this unit,
anyservicemaintenanceshouldbeperformedby
specialisedoperators.PleasecontactyourArena
Lucidealerforanyoperation.
Alwaysensurethatthestructuretowhichyouare
attachingtheunitissecureandisabletosupport
theweightofeachunit.
LEDmoduleisnotreplaceable.
Do not use any solvent based cleaning agents.
Useonlyasoft,dryantistaticcloth.
Theinstallation ofLEDmodules(includingpower
supplies) should be done according to current
technical rules and regulations. The installation
shouldbeperformedonlybyaqualifiedoperator.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
componentdefects.
WARNINGS
User'sManual
30WPAR56LEDlampforlightingpoolsand
fountains
Please note that as part of Arena Luci's ongoing commitment to continuous product development,
specifications are subject to change in the course of product improvement without notice.Arena Luci is not
responsiblefordamagesresultingfromimproperordifferentusethanexpected.
2/4
LL0291WLL0291RGB
INSTALLINGTHEDEVICE
Installation can only be carried out by mounting the specific
flushmountedboxandonlyinimmersion:toavoiddamaging
the appliance, it cannot be operated outside the water for
morethan10seconds.
Removethepowersupplyvoltagetothesystem.Removethe
lampholdercoverfromtheedgeofthepoolandplaceitona
rigidsurface,withthelampholderfacingupwards;removethe
cap from the cover by unscrewing the M6x35 Allen screws.
Rememberthepositionofthethreesealspringsandthethree
rosettes for subsequent reassembly. When lifting the cover,
remove the Oring 91.5x11.5 and place it on the surface.
Replacetheexistinglampbydisconnectingitfromthehood's
electricalconductors;restthenewLL0291lampinthecenter
of the hole in the PAR 56 headlight cover, holding the rear part of the lamp upwards and place the OR seal
91.5x11.5abovethelamp,keepingitascentralaspossible.
ConnecttheeyeletsofthepowersupplywirescomingoutofthelampdoortotheM4x8screwterminalsonthe
back of the lamp body. There is no
polarity to respect as the lamp requires
a12Vsupplyinalternatingvoltage.
For greater safety, in the unfortunate
hypothesis of degeneration of the
watertightness of the assembly and to
avoidconsequent oxidation, corrosion and shortcircuitphenomena, it is necessary tofillthe cavity where the
lamp power supply terminals are housed with an insulating waterproofing resin, to cover completely the
electricalcontacts.TheresincodeisRESINA015.
Closethelamp cover over the lamp takingcareto center the Oring 91.5x11.5 in the housing providedinthe
shell itself, in order to guarantee water tightness.The wires connecting to the lamp must be kept and folded
insidetheshell.RetightentheM6x35capfixingscrews,respectingtheoriginalpositionsofthewashersandthe
sealingsprings.
POWERSUPPLY
Ifyouneedmorethanonejunctionboxtocarryouttheelectricaldistribution, theconnectionoftheLEDhead
powercabletothepowersupply linemustinanycase bemadeinajunctionboxwith adequateIPprotection
characteristics depending on the location of installation.The junction boxes are to be laid outside zone 1, as
requiredbytheCEI648/7Italianstandard.Ifthetransformerisplacedinsidethesamejunctionbox,thelatter
mustbeoutsidethezone2.
Thelampcanoperatewithvoltagefrom12to15VACandwithfrequenciesof50and60Hz.Notypeofsetting
is necessary, it is set automatically based on the voltage and frequency of the power supply detected. The
powersupplycablemustbeofthespecialtypeinneoprenetypeHO7RNF,suitableforimmersionapplications
andincompliancewiththemostrecentregulations.
The choice of the transformer must be made on the basis of the total power absorption of all the equipment
connectedinthesameignitiongroup;oncethisvalueisobtained,themostappropriatetransformersizecanbe
chosen.Bothlaminatedandtoroidaltransformersareindicated.
Itisadvisabletoleaveamarginofatleast25%lowerthanthemaximumloadofthechosentransformer.
Connectthetransformertothemainssocket,respectingtheindicatedLNEpolarity(browncolors=L,blue=
N,yellow/green=E).Checkthattheoutputvoltageofthetransformeriscompatiblewiththespecificationsof
the device. Connect the transformer outputs to the device power cable. It is not necessary to respect any
polarity, since the lamp operates in alternating voltage. For multiple connections of LED illuminators it is
recommendedtousesectionsofatleast4mm
2
orlargerbasedonthecalculationofthevoltagedrop.
Connectthetransformertothemainsbymeansofathermomagneticdifferentialswitch.
3/4
USER'SMANUAL
OPERATION
The RGB version of the lamp (code LL0291RGB) has 16 preset color combinations, i.e. it is possible to
automaticallyexecutescenesprogrammedintheunit'sinternalmemory.Tomodifythesceneinexecutionitis
sufficient to interrupt the supply line for a specified time: in this way the steps stored in the device are
sequentiallyreproducedoneaftertheother.Connectanormallyclosedbuttoninserieswiththelamppowerline,
asshowninthediagramabove.Thelampkeepstherunningfunctioninmemorywhenitisturnedoff.
Pressthebuttonfor0.5secondsandreleaseittoadvancethesteps.
Pressthebuttonfor1.5secondsandreleaseittoreturntostep1.
To facilitate use, even from a distance, and the synchronization of several lamps, it is possible to use the
optionalcontrolsystemwithradiocontrol(codeLC2041).
Thefollowingtableshowstheautomaticfunctionsofcolorvariation.
MAINTENANCEANDPERIODICALCHECKS
Mechanicalparts
Checkthattheprojectorisnotmechanicallydamaged.
Cleantheprojectorglassregularlyusingasoftcloth.
Carefully check the gaskets that ensure resistance to water and dust and, if necessary, contact the service
centerforreplacementofthedeterioratedparts.
Electricalparts
Check the electrical connections, in particular the earthing and the correct insertion of the removable
connectors,pressthemifnecessaryandputthembackastheywereoriginally.
Checkthatthereisnooxideontheelectricalcontacts,ifnecessaryremoveitusingsuitableproductsandtools.
Replacementparts
Allsparepartsoftheequipmentcanbefoundataservicecenter.
4/4
LL0291WLL0291RGB
Problem
Thelampdoesnotlight
Thelamphasmoistureformation
Thelampemitslittlelight
Possiblesolution
Checkforthepresenceofmainsvoltage
Check the electrical connections and the
operationofthetransformer
Disconnect the power supply immediately and
contacttheservicecenter
Checkthatthefrontglassisclean
TROUBLESHOOTING
Belowaresomeofthemostfrequentproblemswithsomeoftheirpossiblesolutions.
ArenaLuciDesignsrlviaSvizzera12/1446042CastelGoffredo(MN),Italy
Tel.+390376782411Fax+390376780973
www.arenaluci.cominfo@arenaluci.it
WARRANTYCONDITIONS
The unit is guaranteed for 24 months from the date of
purchase against defects in workmanship or materials
thatcomposeit.
This warranty does faults due to incorrect or improper
useofthedevice.
The warranty is immediately void if the unit has been
tamperedwithoropenedbyunauthorizedpersonnel.
The warranty provides, at the discretion ofArena Luci,
repairorreplacementoffaultyequipment.
Theserialnumberandmodelofthedevicearerequired
to obtain information or assistance from the dealer. We
invite youto transcribe them in time:for any request of
information or services, this will result in a quick and
effectiveoperation.
CERULES
The device meets the essential requirements of the
Directives LVD 2014/35/UE, EMC 2014/30/UE, RAEE
2012/19/UE, RoHS 2011/65/UE, Ecodesign
2009/125/CE  reg. (UE) 1194/2012, Energy label
2010/30/UE reg. (UE) 874/2012 reg. (UE) 518/2014,
GPSD2001/95/CE.
Warnings
Disposal of Old Electrical & Electronic Equipment
(applicable in the European Union and other European
countrieswithseparatecollectionsystems).
The product shall not be treated ashousehold
wastebutmustbehandedovertotheapplicable
collectionpointfortherecyclingofelectricaland
electronicequipment.Byensuringthisproductis
correctly disposed, you will help prevent potential
negativeconsequencesfor theenvironmentandhuman
health,whichcouldotherwisebecausedbyinappropriate
waste handling. The recycling of materials will help to
conserve natural resources. For more detailed
informationaboutrecyclingofthisproduct,pleasecontact
yourcityoffice,yourhouseholdwastedisposalserviceor
yoursupplier.
Powersupply
Current
Powerconsumption
Connection
Source
Beamaperture
Luminousflux
Material
Color
Weight
Protection
Suitabletobefittedonnormallyflammablesurfaces
Appliedstandards
12V15VAC
2.5Amax
30Wmax
Screwclampsforeyelets
9PowerLED
WideFlood
1800lm(LL0291W)1015lm(LL0291RGB)
Policarbonate
White
370g(LL0291W)380g(LL0291RGB)
IP68
TECHNICALSPECIFICATION
LL0291ENR0|03/2019
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Arena Luci Design LL0291­-W User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI