meitav-tec PS-4500-P-3S-FC-Super Product information

  • Hello! I've analyzed the provided datasheet for the meitav-tec Controller PS4500-P-3S-FC-SUPER and its compatible wall panels. This document details the wiring, configuration, and operational modes. It covers aspects like sensor connections, jumper settings for different system types, and fan control behaviors. I am ready to assist you with any questions you might have about this device and its features.
  • What should I do before making any changes to the unit?
    When is the pump output active?
    What happens if the occupancy sensor is not connected?
Date:
Title:
File name: PS4500-P-3S-FC-SUPER-CF.VSD
Print name:
P
S4500-P-3S-FC-SUPER (
o
C/
o
F)
19.02.08
PS2500-PM2-3S
HEAT
13 12 11
F6
0 Y 1 2 3 8 7 0 B A1
2
3
8
7
Wall Panel (Option)
ETN/X500 ; FMH/X500 ; IRP/X500
~
N
GND
0
T3
0
T2
0
T1
P1
P2
P3
+12V
-12V
IR
230Vac
Change Over Sensor /
Discharge sensor
Return Air Sensor
Not in use
CONTROLLER
POWER
SUPPLY
+-
Fuse
8A
220Vac
JP5
JP4
Not in use
Occupancy
Sensor
12Vdc
RS485
On/Off Mode Fan
RS485
Indoor Coil Sensor
F5 – Short – Fan Only mode available
(Selectable through thermostat)
F5 – Open – Fan Only mode not available
Indoor Coil Sensor (T3) Indoor
Fan in heat mode
Auto Fan = ON :
With Indoor Coil Sensor
T3 > 36ºC → Fan ON
T3 < 32ºC → Fan OFF
Without Indoor Coil Sensor
The Indoor Fan will operate when
there is a demand for heating (with
30 seconds time delay)
Jumpers – JP4 & JP5
JP4 – SHORT (4-Pipe System)
Auto change over active
2 separate outputs for Cool and Heat
T2 – for monitoring only
JP4 – OPEN (2-Pipe System)
Auto change over not active
1 output for Cool and Heat
T2 – Logic selection
JP5 - SHORT
In Cool mode – Auto Fan
In Heat mode – Auto Fan
JP5 - OPEN
In Cool mode – Fan ON
In Heat mode – Fan ON
Occupancy Sensor
When the IR (N.C.)
input is open for 10
minutes, all outputs
turn Off.
Short the (-12V) and
(IR) connectors, only
when an occupancy
sensor is not
connected
Change Over Sensor (T2) in 2-
Pipe system:
With Change Over Sensor
T2 < 20ºC → Cool
T2 > 30ºC → Heat
Without Change Over Sensor
Manually select the mode using
the wall panel or computer.
F4 – Fault 1 input (N.C.)
When open – all outputs OFF (no delay)
F6 – Fault 2 input (N.C.)
Only for indication through the protocol
Not in use
(Temperature through
the protocol)
JP1
o
T Ambient reading from panel or from Main Board
FMH-X500 – JP2
“A” position – read temperature from main board.
“B” position – read temperature from panel.
ETN-X500 – JP2
OPEN read temperature from main board.
SHORT – read temperature from panel.
JP1
End of Network jumper
– Jumper Short
(Resistance 120 Ω)
JP1 JP1
Open Short
B
A
12387
0
F5
0
F4
0
F3
0
F2
0
F1
0
PR
0
FAN (3A)
+-
Modbus/Maxinet Protocol
Important !
Disconnect power to the main board
before making any changes to DIP
switches/Jumpers, wiring the unit
and/or connecting the wall panel.
Shielded cable - Connect the
shield to the “8” terminal of
the main board.
5x0.5 12VDC
Drawn: P.Rechtman
Checked: O.Volovich
Approved: E.Roy
Pump Output –
230Vac , 1A
Will be active only
when the Cool output
is also active
0,PR – Short – Fahrenheit
0,PR – Open - Celsius
Modbus/Maxinet Protocol
Tel: +972 (3) 962 6462
Fax: +972 (3) 962 6620
e-mail: support@meitavtec.com
meitav-tec
W
Y
0
0
OUT 0-10V (Cool)
OUT 0-10V (Heat)
Not in use
Twisted pair cable (Shielded,22AWG )
Connect the shield to ground at one
end of communication line
S/W Revision , Removed ID
1 Original 21.06.07
2 19.02.08
Software: 08081215
Checksum: D834
/