Kichler Lighting 9704BK User manual

Type
User manual

This manual is also suitable for

1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work without
shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home. Place
the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),
thatcontrolthepowertothextureorroomthatyouareworking
on.
c) Placethewallswitchinthe“OFF”position.Ifthexturetobe
replaced has a switch or pull chain, place those in the “OFF” position.
2) Thread hexnut onto threaded pipe so that approximately 5 threads are
exposed above hexnut. Thread that end of threaded pipe into mounting
strap. Thread second hexnut onto end of threaded pipe protruding from
back of mounting strap. Tighten both hexnuts against mounting strap
3) Attach mounting strap to outlet box. (Screws not provided)
4) Connect safety cable assembled to canopy to mounting bracket.
(Thiswillallowforxturetobesupportedwhilewireconnectionsare
made.)
5) Grounding instructions: (See Illus. A or B).
A) Onxtureswheremountingstrapisprovidedwithaholeand
two raise dimples. Wrap ground wire from outlet box around
green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Attachground
wire from outlet box under cupped washer and green ground
screw, and thread into mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxturegroundwireto
outlet box ground wire with wire connector. (Not provided.) After following
the above steps.
Never connect ground wire to black or white power supply wires.
6) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
7) Pushxturetowall,carefullypassingthreadedpipethroughhole.
8) Securexturetowallusingthreadedcap.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR
IN WET LOCATIONS.
9) Mountingsurfaceshouldbeclean,dry,atand1/4”largerthatthe
canopy on all sides. Any gaps between the mounting surface and
canopyexceeding3/16”shouldbecorrectedasrequired.
10) With silicone caulking compound, caulk completely around where back
of canopy meets the wall surface to prevent water from seeping into
outlet box.
1) APAGUE LA ALIMENTACIÓN ELÉCTRICA.
IMPORTANTE: Antes de comenzar, NUNCA trate de trabajar sin antes
desconectarlacorrientehastaqueeltrabajosetermine.
a) Vaya a la caja principal de fusibles, o interruptor o caja de circuitos
desucasa.Coloqueelinterruptordelacorrienteprincipalen
posición de apagado “OFF”.
b) Desatornilleel(los)fusible(s),ocoloqueelinterruptoro
interruptoresdelbreakerenposicióndeapagado“OFF”,que
controla (n) la corriente hacia el artefacto o habitación donde está
trabajando.
c) Coloqueelinterruptordeparedenposicióndeapagado“OFF”.Si
elartefactoquesevaareemplazartieneuninterruptorocadena
quesejala,colóquelosenlaposicióndeapagado“OFF”.
2) Rosquelatuercahexagonaleneltuboroscadodemodoque
aproximadamente 5 roscas estén expuestas arriba de la tuerca hexagonal.
Rosqueeseextremodeltuboroscadoenlaabrazaderademontaje.
Rosqueunasegundatuercahexagonalenelextremodeltuboroscado
quesobresaledeatrásdelaabrazaderademontaje.Aprieteambas
tuercas hexagonales contra la abrazadera de montaje.
3) Sujete la plancha para montar a la caja de conexión. (No se proveen
los tornillos.)
4) Conecte el cable de seguridad montado a la capuchon dentro del
cartelademontaje.(Estopermitequeelartefactoseasoportado
mientras se hagan las conexiones de alambres)
5) Instrucciones de conexión a tierra solamente para los Estados Unidos.
(Vea la ilustracion A o B).
A) Enlaslámparasquetieneneleje,demontajeconunagujero
y dos hoyuelos realzados. Enrollar el alambre a tierra de la caja
tomacorrientealrededordeltornilloverdeypasarloporelaquiero.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
DateIssued:11/30/12 IS-9704-US
THREADED CAP
TAPA ROSCADA
B) En las lámparas con una arandela acopada. Fijar el alambre a
tierra de la caja tomacorriente del ajo de la arandela acoada y
tornilloverde,ypaserporelejedemontaje.
Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra
de la lámpara al alambre a tierra de la caja tomacorriente con un conector
de alambres. (No incluido) Espués de seguir los pasos anteriores.
Nunca conectar el alambra a tierra a los alambres eléctros negro o blanco.
6) Haga les conexiones de los alambres (no se proveen los connectores.)
La tabla de referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
7) Empuje el artefacto a la pared pasando cuidadosamente el tubo
roscado a través del agujero.
8) Sujete la unidad contra la pared apretándola con la tapa roscada.
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE
LIBRE Y/O EN UN LUGAR MOJADO.
9) Lasuperciedemontajedebeestarlimpia,seca,serplanay1/4”más
grandequeelesdudeteentodoslosbordes.Cualquierespaciolibre
entrelasuperciedemontajeyelescudetequeexcedade3/16”debe
corregirsesegúnserequiera.
10) Calafatee totalmente con compuesto de calafatear de silicona alrededor
dondeelescudetesientaenlasuperciedelaparedparaimpedirla
entrada de agua en la caja de conexiones.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
THREADED PIPE
TUBO ROSCADO
MOUNTING STRAP
PLANCHA PARA
MONTAR
ARANDELA
CONCAVA
A
B
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
HEXNUT
TUERCA
HEXAGONAL
SAFETY CABLE
CABLE DE
SEGURIDAD
1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work without
shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home. Place
the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),
thatcontrolthepowertothextureorroomthatyouareworking
on.
c) Placethewallswitchinthe“OFF”position.Ifthexturetobe
replaced has a switch or pull chain, place those in the “OFF” position.
2) Thread hexnut onto threaded pipe so that approximately 5 threads are
exposed above hexnut. Thread that end of threaded pipe into mounting
strap. Thread second hexnut onto end of threaded pipe protruding from
back of mounting strap. Tighten both hexnuts against mounting strap
3) Attach mounting strap to outlet box. (Screws not provided)
4) Connect safety cable assembled to canopy to mounting bracket.
(Thiswillallowforxturetobesupportedwhilewireconnectionsare
made.)
5) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
6) Pushxturetowall,carefullypassingthreadedpipethroughhole.
7) Securexturetowallusingthreadedcap.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR
IN WET LOCATIONS.
8) Mountingsurfaceshouldbeclean,dry,atand1/4”largerthatthe
canopy on all sides. Any gaps between the mounting surface and
canopyexceeding3/16”shouldbecorrectedasrequired.
9) With silicone caulking compound, caulk completely around where back
of canopy meets the wall surface to prevent water from seeping into
outlet box.
1) COUPER L’ALIMENTATION SECTEUR.
IMPORTANT: TOUJOURS couper l’électricité avant de commencer le
travail.
a) Localiser le coffret à fusibles ou le disjoncteur du domicile. Mettre
l’interrupteur principal en position d’Arrêt.
b) Dévisserleoulesfusibles(oumettreledisjoncteursurArrêt)qui
contrôlentl’alimentationversleluminaireoulapiècedanslaquelle
le travail est effectué.
c) Mettre l’interrupteur mural en position d’Arrêt. Si le luminaire à
remplacer est doté d’un interrupteur ou d’une chaîne connectée à
l‘interrupteur, placer ces éléments en position d’Arrêt.
2) Enlerl’écrouhexagonalàl’extrémitédutuyauletédefaçonàce
qu’environ5letssoientexposésau-dessusdel’écrouhexagonal.
Enlercetteextrémitédutuyauletédanslabridedemontage.Enler
lesecondécrouhexagonalàl’extrémitédutuyauletéquidépassede
la bride de montage. Serrer les deux écrous hexagonaux à la bride de
montage.
3) Fixer la bride de montage sur la boîte à prises. (Vis non fournies).
4) Connecter le câble de sécurité assemblé à l’intérieur du cache sur le
support de montage.(Ceci permettra de soutenir le luminaire lors du
branchementdesls.)
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
DateIssued:11/30/12
IS-9704-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
THREADED CAP
BOUCHON FILETE
5) Connecterlesls(connecteursnonfournis).Sereporterautableauci-
dessous pour faire les connexions.
6) Pousserl’appliquecontrelemur,etfairepasserlesvisdexaitondans
les trous de passage en procédant avec précautions.
7) Fixerl’appliquecontrelemuràl’aidedesrondellesfreinsetdubouchon
lete.
INSTRUCTIONS DE MONTAGE DE LUMINAIRE À L’EXTÉRIEUR ET/OU
DANS DES LIEUX HUMIDES.
8) Lasurfacedemontagedoitêtrepropre,sèche,plateetde0,6cmplus
épaissequelecachesurtouslescôtés.Toutécartentrelasurface
demontageetlecachedépassantde0,5cmdoitêtrerectiéselonles
besoins.
9) À l’aide de matériaux d’étanchéité à la silicone, calfeutrer bien autour
où l’arrière du cache entre en contact avec le mur pour empêcher l’eau
de passer dans la boîte de raccordement.
THREADED PIPE
TUBE FILETÉ
MOUNTING STRAP
COLLLIER DE
FIXATION
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
HEXNUT
ECROU
HEXAGONAL
SAFETY CABLE
CÂBLE DE SÉCURITÉ
  • Page 1 1
  • Page 2 2

Kichler Lighting 9704BK User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI