Kichler Lighting 52209PN User manual

Type
User manual
IS-52209-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Aach tube[P] to main ring[E] by passing hook at end of tube through loop
aached to ring. Repeat for remaining tubes.
2) Pass xture wires from tube through hole in lower canopy[T], through
knob[Q], and through coupling inside lower canopy.
3) Aach tube[P] to lower canopy by inserng threads protruding from end of
tube through hole in lower canopy. Secure tube to lower canopy by screwing
knob[Q] onto threads protruding into lower canopy.
4) Aach remaining tubes to lower canopy by inserng the end of each tube
with protruding threads through corresponding hole in lower canopy. Secure
by screwing knob onto threads protruding into lower canopy.
5) Pass xture wires from threads protruding from top of lower canopy[T]
through hole in center of cover[R], and coupling[S].
6) Pass threads protruding from top of lower canopy[T] through hole in center
of cover[R] and lower cover onto coupling inside lower canopy.
7) Screw coupling[S] onto threads protruding out of cover to secure cover.
8) Pass xture wires from coupling[S] through desired number of stems[A] and
short threaded tubes[B]. Screw stems together using short threaded tubes.
and screw connected stems into coupling[S] using a short threaded tube.
NOTE: Thread locking compound must be applied to all stem threads as
noted with symbol (4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
9) Pass xture wires from last stem through short threaded tube[B] and through
loop[K]. Screw short threaded tube into top of last stem and into loop.
10) Take threaded pipe[D] from parts bag and screw in screw collar loop[I] a
minimum of 6 mm (1/4”). Lock into place with hexnut[N].
11) Run another hexnut down threaded pipe almost touching rst hexnut.
Now screw threaded pipe into mounng strap[F]. Mounng strap must be
posioned with extruded thread faced into outlet box[C]. Threaded pipe
must protrude out the back of mounng strap. Screw third hexnut onto end
of threaded pipe protruding from back of mounng strap.
12) Connect mounng strap[F] to outlet box using the strap mounng
screws[H].
13) Unscrew the threaded ring[J] from screw collar loop. Take upper canopy[G]
and pass over screw collar loop. Approximately one half of the screw collar
loop exterior threads should be exposed. Adjust screw collar loop by turning
assembly up or down in mounng strap. Remove upper canopy.
14) Aer desired posion is found, ghten both top and boom hexnuts up
against the boom and top of the mounng strap.
15) Slip upper canopy over screw collar loop and thread on threaded ring. Aach
chain link[U] (with xture connected) to screw collar loop. Close the open link
by wrapping with a towel and squeezing closed using pliers. Unscrew threaded
ring, let upper canopy and threaded ring slip down.
16) Pass electrical wire and ground wire through chain link[U], threaded ring[J],
upper canopy, screw collar loop, threaded pipe and into outlet box.
17) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
18) Make wire connecons. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
19) Raise upper canopy to ceiling.
20) Secure upper canopy in place by ghtening threaded ring onto screw collar
loop.
21) Screw decorave rods[O] onto threads protruding from top of center arms.
22) Carefully lower candle covers[M] down over sockets.
23) Carefully slide discs[L] down over candle covers.
24) Insert recommended bulbs. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
[A] Stems
[B] Short Threaded
Tubes
[C] Outlet Box
[D] Threaded Pipe
[E] Main Ring
[F] Mounting Strap
[G] Upper Canopy
[H] Strap Mounting
Screws
[I] Screw Collar Loop
[J] Threaded Ring
[K] Loop
[L] Discs
[M] Candle Covers
[N] Hexnut
[O] Decorative Rods
[P] Tube
[Q] Knob
[R] Cover
[S] Coupling
[T] Lower Canopy
[U] Chain Link
Installaon Instrucons
B
A
A
O
S
R
Q
P
T
E
I
J
U
K
B
G
N
D
C
F
H
L
M
  • Page 1 1
  • Page 2 2
  • Page 3 3

Kichler Lighting 52209PN User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI