Ferm MMM1005 Owner's manual

Type
Owner's manual
2 Ferm
Product: Ferm Digital Multimeter
Type MM-925, Art. nr. 185925
Ferm, Genemuiden, The Netherlands
For a proper operation of this multimeter
please read this instruction manual care-
fully before use.
Do no apply an input which exceeds the maximum
and the measurement range.
For an accurate measurement, change the battery
when ‘ ‘appears on the display.
If the fuse needs to be replaced, a fuse of the same spe-
cification (200 mA / 250 V) must be used.
Keep the test lead away from the circuit and put the
switch into the "power off" position when the battery
needs to be changed, the fuse be replaced or the ca-
sing opened.
Do not store the multimeter in a place with extreme
temperatures or high relative humidity.
When the multimeter has not been used for a long pe-
riod of time, rotate the switch back and forth several
times in order to promote proper functioning.
Do not use volatile or corrosive cleaning agents for
the multimeter; use a soft cotton cloth with a mild de-
tergent instead.
WARNING:
Please observe the WARNINGS in this manual. Impro-
per use can lead to bodily injury.
The following legend applies to this manual:
- Dangerous voltage (Take care not to receive an
electric shock when measuring the voltage).
- Ground (Voltage between input terminal and
earth).
- Direct current (DC).
- Alternating current (AC).
- Replace fuses with the amp/Volt ratings shown (spe-
cifications).
Brief description
This multimeter has been designed to ensure the ef-
fective protection of the LCD display. The built-in
test lead ensures safe and easy use.
The multimeter can be opened by simply pressing the
one-touch button on the cover.
The multimeter can be switched off automatically by
closing the cover. This will save battery energy.
Standard features
3 1/2 digit LCD display, max. display 1999, height 11
mm.
When taking measurements in the overmeasuring
range, 'I' will appear on the display. In that case the me-
asuring range needs to be increased.
Equipped with diode checking and logic testing.
Indicates when the battery needs to be replaced.
• 9 V battery.
Outside dimensions: 139 x 75 x 26 mm.
Weight: approx. 200 g (incl. battery and test lead).
The multimeter is protected with a 230 V / 200 mA fu-
se in voltage and current measurement.
The multimeter has a 230 V AC/DC max. overvoltage
protection in resistance measurement.
Front panel lay-out:
A) Display
B) Transistor socket
C) Function switch
D) Range selector
Technical specification and operating procedure
Ambient temperature: 23 + 5 °C
Relative humidity: < 75%
1.DC Voltage
RANGE RESOLUTION
2000 mV 1 mV
20 V 10 mV
200 V 100 mV
450 V 1 V
Input resistance: 1 M
Max. input: 450 V DC
Operating procedure:
A. Put the function switch into the position.
B. Select the correct measuring range. In case of doubt,
select the maximum range. If possible, switch back to
a smaller range for a more accurate measurement.
C. Apply the test lead to the testing point.
D. Check the reading on the display.
UK
English
9 V Type 6F22
---
V
Ferm 27
å˚ Ò ÔÓÎÌÓÈ ÓÚ‚ÂÚÒÚ‚ÂÌÌÓÒÚ¸˛ Á‡fl‚ÎflÂÏ,
˜ÚÓ Ì‡ÒÚÓfl˘Â ËÁ‰ÂÎË ÒÓÓÚ‚ÂÚÒÚ‚ÛÂÚ
ÌËÊÂÔÂ˜ËÒÎÂÌÌ˚Ï Òڇ̉‡Ú‡Ï
Ë ÌÓχÚË‚Ì˚Ï ‰ÓÍÛÏÂÌÚ‡Ï:
EN61010-2-31, EN61010-1
EN55011, EN50082
‚ ÒÓÓÚ‚ÂÚÒÚ‚ËË Ò Ô‡‚Ë·ÏË:
73/23EEC
89/336/EEC
ÓÚ 26-05-1998
ÉÂÌÂÏÓȉÂÌ, çˉÂ·̉˚
ÑÊ. å. ùÌÒËÌ„,
éÚ‰ÂÎ ÍÓÌÚÓÎfl ͇˜ÂÒÚ‚‡
CE
ı
ДЕКЛАРАЦИЯ О СООТВЕТСТВИИ ВЕЛИКОБРИТАНИЯ
(
R
)
26 Ferm
Ferm 3
2. AC Voltage
RANGE RESOLUTION
200 V 100 mV
450 V 1 V
Frequency response: 45-400 Hz
Max. input: 450 V AC
Operating procedure:
A. Put the function switch into the position.
B. Select the correct measuring range. In case of doubt,
select the maximum range. If possible, switch back to
a smaller range for a more accurate measurement.
C. Apply the test lead to the testing point.
D. Check the reading on the display.
3. Direct Current
RANGE RESOLUTION
200 mA 100 µA
Uses a 200 mA /250 V fuse for overvoltage protection.
Operating procedure:
A. Put the function switch into the position.
B. Select the 200 mA measuring range.
C. Apply the test lead to the testing point.
D. Check the reading on the display.
4. Resistance
RANGE RESOLUTION
2000 1
20 K 10
200 K 100
2000 K 1 K
Open circuit voltage: 2.8 V
Overvoltage protection: 230 V DC or AC in less than
10 seconds.
Operating procedure:
A. Put the function switch into the position.
B. Select the correct measuring range. In case of doubt,
select the maximum range. If possible, switch back to
a smaller range for a more accurate measurement.
C. Apply the test lead to the testing point.
D. Check the reading on the display.
5.Diode
(Test current around 1 mA) and display the forward voltage
drop.
Operating procedure:
A. Put the function switch into the position.
B. Select the 2000 range with the range selector.
C. Apply the test lead to the diode, red to positive and
black to negative.
D. Check the reading on the display.
6. Transistor hFE
V c/e = 2.8 V
lb = 10 µA
Operating procedure:
A. Put the function switch into the hFE position.
B. Select the hFE position with the range selector.
C. Place the transistor in the hFE testing slot. (Connect
the base-collector/emittor in the correct way to the
transistor socket).
D. Check the reading on the display.
We declare under our sole responsability that this
product is in conformity with the following
standards or standardized documents
EN61010-2-31, EN61010-1
EN55011, EN50082
in accordance with the regulations:
73/23EEC
89/336/EEC
from 26-05-1998
GENEMUIDEN NL
G.M. Ensing
Quality department
CE
ı
DECLARATION OF CONFORMITY
(
UK
)
v
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Ferm MMM1005 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI