RADIO KEY
®
XRM / XRS Installation Instructions
INSTALLATION STEPS FOR RK-XRM
1. Drill holes as needed per installation diagram shown to
the left.
2. Feed cable through 3/4” hole.
3. Attach reader to any flat surface
with two #6 screws.
4. Snap label insert into front of
reader to cover screws.
INSTALLATION STEPS FOR RK-XRS
1. Drill holes as needed per installation
diagram shown to the left.
2. Feed cable through 3/4” hole.
3. Attach the mounting plate to the
mounting surface with the appropriate
fasteners.
4. Attach the housing to the mounting
plate by inserting the two tabs inside
the top of the housing into the two slots
at the top of the mounting plate.
5. Secure by installing supplied screws
into the hole at the bottom of the reader.
6. Connect cable per wiring diagram shown below.
SWITCHPLATE INSTALLATION DIAGRAM
Mounting
Plate
Reader
Housing
Mounting
Surface
¿
¿
Use appropriate
Fastener
¿
Use supplied
screw
¿
3/4” diameter
through hole
for cables.
¿
¿
¿
3.28
3.50
1.60
Label Tabs
Insert Here
LED
¿
¿
¿
¿
¿
¿
¿
3.20
4.50
¿
¿
MULLION INSTALLATION DIAGRAM
1.0”
l
l
l
l
1.3”
Use appropriate
#6 Fastener
3/4” Diameter through
hole for cable and
buzzer.
l
l
¿
20301 Nordhoff Street Chatsworth, CA 91311
phone 818-882-0020 fax 818-882-7052
TOLL-FREE (800) 891-0020
E-mail: mail@securakey.com
Web site: www.securakey.com
POWER REQUIREMENTS
5-14 VDC, 120 mA maximum
INPUTS & OUTPUTS
LED Bicolor (Red or Green)
Buzzer Short chirps upon presentation of any
Secura Key transponder.
Maximum Network Distance RS-485 - Single Twisted Pair, Plus
Ground and Shield, 18-24 AWG. Total
system cable length: 4,000 ft.
Cable: CAT 5
ENVIRONMENT
Access Control Unit and Key Tag
Ambient Temperature -40° to +70°C (-40° to +158°F)
Humidity 0 to 95% (non-condensing)
WIRE COLOR DESCRIPTION
BROWN
BROWN-WHITE
BLUE
BLUE-WHITE
GROUND
VCC
RELAY
RELAY
WIRING CONNECTIONS
GREEN-WHITE
*
Connect to GROUND to activate.
GREEN
INPUT 2
INPUT 1
ORANGE
DATA-B
ORANGE-WHITE
DATA-A