SRN FRU List Problem
40032 32 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 32 MB DRAM in adapter card module 0 has
failed.
Action: Exchange the FRU for a new FRU.
40064 64 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 64 MB DRAM in adapter card module 0 has
failed.
Action: Exchange the FRU for a new FRU.
40128 128 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 128 MB DRAM in adapter card module 0 has
failed.
Action: Exchange the FRU for a new FRU.
41004 4 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 4 MB DRAM in adapter card module 1 has failed.
Action: Exchange the FRU for a new FRU.
41008 8 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: An 8 MB DRAM in adapter card module 1 has
failed.
Action: Exchange the FRU for a new FRU.
41016 16 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 16 MB DRAM in adapter card module 1 has
failed.
Action: Exchange the FRU for a new FRU.
41032 32 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 32 MB DRAM in adapter card module 1 has
failed.
Action: Exchange the FRU for a new FRU.
41064 64 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 64 MB DRAM in adapter card module 1 has
failed.
Action: Exchange the FRU for a new FRU.
41128 128 MB DRAM module 1 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 128 MB DRAM in adapter card module 1 has
failed.
Action: Exchange the FRU for a new FRU.
42000 SSA adapter card (50%)
DRAM modules (50%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: The SSA adapter has detected that both DRAM
modules are failing.
Action:
1. Check whether both DRAM modules are correctly installed
on the adapter card. Make any necessary corrections.
2. If this problem has occurred immediately after an upgrade
to the adapter card, check whether the correct type of
DRAM modules have been installed. Make any necessary
corrections.
3. If the problem remains, exchange the adapter card FRU for
a new one.
Do not exchange any DRAM modules yet
.
4. Install the DRAM modules from the original adapter card
onto the new adapter card, then install the new adapter
card.
5. If the problem remains, exchange the DRAM modules for
new modules.
6. Install the new DRAM modules onto the original adapter
card. Reinstall the original adapter card.
42200 None Description: Other adapters on the SSA loop are using levels of
microcode that are not compatible.
Action: Install the latest level of microcode on all other adapters
in this SSA loop.
First refer to “Software and Microcode Errors” on page 12 and if
necessary “Download Microcode Function” on page 37.
Service Request Numbers (SRNs) 5