American Standard Bathroom Aids ICU Sink System User manual

Category
Sanitary ware
Type
User manual
1
7301793-100 Rev. C
Introduction: Thank you for selecting our products...products which have been the
benchmarks of fine quality for years. To help insure that the installation process will
proceed smoothly, please read these instructions carefully before you begin. Also,
review the recommended tools and materials list; carefully unpack and examine your
new plumbing fixture.
Channel Lock Pliers
Regular Screwdriver
Recommended Tools & Materials
Rough-In
Dimensions
Phillips Screwdriver
Pipe Wrench
Drill
Plumbers' Putty or Caulking
Tubing Cutter
Tape
Measure
Hacksaw
Pencil
Torch
Level
SAVE FOR FUTURE USE
CAUTION: PRODUCT IS FRAGILE. TO AVOID DAMAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
ICU Sink System
Models: 9118.111, 9118.100 & 9118.150
INSTALLATION INSTRUCTIONS
!
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2012
14-3/4"
(375mm)
17"
(432mm)
4-3/4"
(121mm)
5/8"
(14mm)
1-5/8"
(41mm)
20"
(509mm)
4-3/4"
(120mm)
8" (203mm)
1/2" DIA.
(13mm)
FINISHED WALL
BASE MOUNT
DETAIL
FINISHED
FLOOR
FINISHED
FLOOR
FINISHED
FLOOR
26-1/8"
(663mm)
36"
(914mm)
36-1/2"
(927mm)
36-1/2"
(927mm)
40-1/8"
(1020mm)
2-3/4"
(70mm)
9/16" DIA.
(14mm)
2-3/4"
(70mm)
4"
(102mm)
4"
(102mm)
MOUNTING
STUDS
Adjustable Wrench
*FAUCET PERCH
2-1/2" DIA. (65mm)
*FAUCET PERCH
2-1/2" DIA. (65mm)
*DISCLAIMER: Faucets with a base diameter greater than 2-1/4" (57 mm) will not fit on this
ICU Sink. The Selectronic ICU Faucet was specifically designed to minimize splashing during
operation. American Standard will not be liable for any splashing that occurs if faucets other
than the American Standard ICU Faucets are used.
8"(203mm) BETWEEN
MOUNTING HOLES
RECOMMENDED CARRIERS:
JAY R. SMITH MFG. CO.
MODEL SQ-0-4437
FLOOR MOUNTED SINK SUPPORT
WATTS CA-311
FLOOR MOUNTED URINAL CARRIER
2
7301793-100 Rev. C
NOTE: For ease of installation and accessibility, it is
recommended that straight stops with flex supply tubes be
used. As an alternative, if rigid supply risers are used, it is
suggested to use angle stops in place of the straight stops.
NOTE: For more detailed information, see the installation
instructions supplied with the ICU FAUCET. #(M965119)
3
2
1
36-1/2"
(927mm)
18"
(457mm)
SQ-0-4437 FLOOR
MOUNTED SINK
SUPPORT
1-5/8"
(41mm)
FINISHED WALL
MOUNTING
STUDS
8" (203mm)
FINISHED
FLOOR
INSTALL FAUCETROUGH-IN SUPPLIES AND WASTE OUTLET
INSTALL GRID DRAIN AND OFFSET TAILPIECE
1. Insert WIRES (1), FLEX HOSE (2) and SPOUT SHANK (3)
through center hole of mounting surface.
2. Assemble "C" WASHER (4), STAR WASHER (5) and LOCKNUT
(6) onto threads of SPOUT SHANK (3) from underside of mounting
surface.
3. Align FAUCET and tighten LOCKNUT (6).
1. Apply plumber’s putty to the underside of flange. Install GRID DRAIN into drain outlet.
2. From the underside of SINK install RUBBER GASKET (flat side up) and FRICTION
GASKET onto GRID DRAIN threads. Apply sealent to threads of GRID DRAIN.
3. Apply sealent to threads of OFFSET TAILPIECE and thread into DRAIN ELL.
4. Thread DRAIN ELL onto GRID DRAIN, tighten and align as shown.
1. Rough-in 3/8" supplies and waste outlet connections.
1
2
3
4
5
6
6
5
4
3
3/8" (10mm)
SUPPLIES
4"
(102mm)
*1-1/4" (32mm)
OR 1-1/2" (38mm)
WASTE OUTLET
*CHECK LOCAL CODES
PLUMBER’S
PUTTY
RUBBER
GASKET
FRICTION
GASKET
APPLY
SEALANT
APPLY SEALANT
TO THREADS
DRAIN ELL
OFFSET TAILPIECE
DRAIN ELL
GRID DRAIN
GRID DRAIN
1 2
3
4
3
7301793-100 Rev. C
4
5
6
INSTALL ICU SINK
1. Mount SINK onto the two HANGER STUDS. Hold SINK in place
and temporarily install NYLOCK NUT & WASHER on one of the
HANGER STUDS to retain SINK.
MOUNT ELECTRONICS BOX
COMPLETE WASTE OUTLET CONNECTION
NOTE: Installation with ELECTRONIC BOX only is for cold
or tempered water. Use optional MIXING VALVE with
ELECTRONIC BOX when Hot and Cold supplies are
roughed-in. See illustration below.
8
INSTALL ELECTRONICS HANGER BRACKET
1. Install the ELECTRONICS HANGER BRACKET onto remaining
HANGER STUD. Install NYLOCK NUT & WASHER but do not
tighten fully.
2. Remove NYLOCK NUT & WASHER from first HANGER STUD
and install other end of ELECTRONICS HANGER BRACKET.
Replace NYLOCK NUT & WASHER, tighten both ends. Do not over
tighten, chinaware could become damaged.
NYLOCK NUT
AND WASHER
HANGER STUD
COLD WATER OR
TEMPERED WATER
(3/8" SUPPLY)
HOT
MIXING VALVE
MIXING VALVE
SCREWS
MOUNTING PLATE
ELECTRONIC
BOX
ELECTRONIC BOX
COLD
1
2
1. Connect SUPPLY NUT (1) from SPOUT assembly to nipple on
top of ENCLOSURE (2). Tighten with adjustable wrench to make a
water tight connection.
CONNECT SPOUT HOSE TO ENCLOSURE
ELECTRONIC
BOX
1. Install “P” TRAP. Connect OFFSET TAILPIECE to “P” TRAP.
TAILPIECE may have to be cut to fit installation. Use tubing cutter to
cut TAILPIECE.
P-TRAP
TAILPIECE
1-1/4" OD
1-1/4" or 1-1/2" OD
WASTE OUTLET
ELECTRONICS
HANGER BRACKET
7
1. Remove COVER from ELECTRONICS BOX.
2. Place ELECTRONICS BOX onto MOUNTING PLATE. Align
BOX with mounting holes. Attach with SCREWS provided.
3. Hang MOUNTING PLATE with ELECTRICAL BOX on
HANGER BRACKET.
4
7301793-100 Rev. C
INSTALL AND CONNECT MIXING VALVE
(MIXING VALVE IS OPTIONAL)
CONNECT MIXING VALVE TO WATER SUPPLIES
11
10
12
ELECTRICAL HOOK-UP AND INSTALLATION
COLD WATER
OR TEMPERED
WALL SUPPLY
ELECTRONIC
BOX
1
2
4
3
3
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Proximity ICU Faucet
Certified to comply with ASME A112.18.1M
© 2011 American Standard
To learn more about American Standard Faucets visit our website at: www.americanstandard.com
or U.S. customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-306-1093)
M965119
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ, s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055.193
6056.193
MODEL NUMBERS
6055 / 6056 ICU Faucet shown Installed on
American Standard 9118.111 ICU Sink
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
ENCLOSURE (2).
2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to FLEXIBLE
SUPPLY HOSE (3). Tighten to make a water tight connection. Use
two wrenches to tighten if necessary.
3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.
Connection on FLEXIBLE SUPPLY (3) is 3/8" compression. Use
adjustable wrench to tighten connection. Do not over tighten.
Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom of
the ENCLOSURE (1) base. If additional supply length is
required, installer must purchase parts separately. Important: If
FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.
9
CONNECT WATER SUPPLY TO ENCLOSURE
AND TO COLD OR TEMPERED WALL SUPPLY
1. Remove COVER from MIXING VALVE.
2. Install FIBER SEAL WASHER (4) on MIXING VALVE
NIPPLE (3). Hold MIXING VALVE (1) in place with one hand
and with your other hand thread SWIVEL NUT (2) onto
MIXING VALVE NIPPLE (3). Use an adjustable wrench to
tighten SWIVEL NUT (2).
3. Place MIXING VALVE BOX onto MOUNTING PLATE. Align
BOX with mounting holes. Attach with SCREWS provided.
4. Replace COVER and tighten securely.
NOTE: For complete detailed installation and
operating instructions see installations instructions
supplied with mixing valve. No. M968808
For complete detailed installation and operating instructions see
installations instructions supplied with ICU FAUCET. No. M965119
1
2
1
2
3
4
2
ADJUSTABLE
WRENCH
HOT
MIXING VALVE
ELECTRONIC
BOX
COLD
1. Turn off Hot and Cold water supplies before beginning.
2. Connect FLEXIBLE SUPPLIES directly to wall supplies.
Connections on MIXER supplies are 3/8" compression. Connect left
supply to Hot and right supply to Cold wall supply. Use adjustable
wrench to tighten connections. Do not over tighten.
3. Faucet supplies measure 20" from the bottom of the
ENCLOSURE (3) base.
Note: If additional supply length is required, installer must
purchase parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop as to
avoid kinking.
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
No. M965119
5
7301793-100 Rev. C
WIRE HANGER
EYEBOLT
REMOVE THUMB NUT
FROM EYE BOLT
4. WIRE HANGER is positioned behind ELECTRONIC BOX
and in front of DRAIN.
5. Remove THUMB NUT from EYEBOLT.
13
15
CHECK ALL ELECTRICAL AND
PLUMBING CONNECTIONS
14
TEST INSTALLED FAUCET
INSTALL WIRE HANGER
1.Turn on water supplies and check for
leaks. Tighten any connections if
necessary.
2. Check FAUCET operation, if
adjustment is required refer to the
installation instructions shown at right
supplied with the ICU FAUCET. No.
M965119.
1. Install EYEBOLT onto WIRE HANGER if not installed.
2. Place WIRE end in left SIDE HOLE.
3. Place WIRE end in right SIDE HOLE near DRAIN.
NOTE: If not enough tension, remove WIRE and spread
ends approx. 1" additional and re-attach.
6. EYEBOLT for SINK APRON.
No. M965119
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Proximity ICU Faucet
Certified to comply with ASME A112.18.1M
© 2011 American Standard
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
M965119
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ,s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055.193
6056.193
MODEL NUMBERS
6055 / 6056 ICU Faucet shown Installed on
American Standard 9118.111 ICU Sink
WIRE
WIRE
WIRE HANGER
EYEBOLT
TO ENSURE A LAMINAR WATER FLOW the
air must be slowly purged from the spout. To
do so, cover the SENSOR (1) while slowly
opening the water supply valves. When the
water flows as a solid, smooth, steady stream,
uncover the SENSOR (1) and fully open the
water supply valve.
DETECTION
ZONE
1
6
7301793-100 Rev. C
16
INSTALL SINK APRON
1. Hold APRON up against SINK and flush against finished wall.
2. Mark a line with a pencil on the wall about 6" long as shown on
both sides of the APRON..
3. Remove the APRON. Clean the wall where the APRON
BRACKETS supplied with SINK are to be applied. Peel off the
protective strip from the back of the APRON BRACKETS. Apply the
two APRON BRACKETS to the finished wall parallel to the pencil
marks as shown in the illustration below.
OPTIONAL MOUNTING. (SCREWS AND ANCHORS NOT
SUPPLIED) Use Brackets to mark pilot holes on wall. Drill holes for
ANCHORS. Peel off the protective strip from the back of the APRON
BRACKETS. Apply the two APRON BRACKETS to the finished wall
parallel to the pencil marks as shown and aligned with the mounting holes.
See illustration below. Install SCREWS and tighten.
4. Clean off the pencil marks from wall.
6"
(152mm)
APRON
SINK
6. Retain APRON with THUMB NUT. Finger tight only.5. Position APRON under SINK and against finished wall alinging
EYEBOLT with hole in APRON.
THUMB NUT
EYEBOLT
APRON
APRON
IMPORTANT: SAVE ALL INSTALLATION INSTRUCTIONS FOR FUTURE USE
1/2"
(13mm)
PENCIL MARK
APRON
CLEAN WALL
PROTECTIVE
STRIP
8
7301793-100 Rev. C
THIS WARRANTY IS NOT TRANSFERABLE FROM ORIGINAL CONSUMER PURCHASER.
AS AMERICA, INC. ONE YEAR LIMITED WARRANTY
If inspection of this AS America, Inc. (“American Standard”) plumbing product, within one year after its initial
purchase, confirms that it is defective in materials or workmanship, American Standard will repair or, at its
option, exchange the product for a similar model.
This limited warranty applies only to the original purchaser and installation of these products. In the event of a
limited warranty claim, proof of purchase will be required—save sales receipt.
This limited warranty does not apply to local building code compliance. Since local building codes vary
considerably, the purchaser of this product should check with a local building or plumbing contractor to insure
local code compliance
before installation.
This limited warranty is void if the product has been moved from its initial place of installation; if it has been
subjected to faulty maintenance, abuse, misuse, accident or other damages; if it was not installed in accordance
with American Standard's instructions; or if it has been modified in a manner inconsistent with the product as
shipped by American Standard.
American Standard's option to repair or exchange the product under this limited warranty does not cover any
labor or other costs of removal or installation. IN NO EVENT WILL AMERICAN STANDARD BE LIABLE FOR
THE COST OF REPAIR OR REPLACEMENT OF ANY INSTALLATION MATERIALS, INCLUDING BUT NOT
LIMITED TO, TILES, MARBLE, ETC. American Standard will not be responsible for any other incidental or
consequential damages attributable to a product defect or to the repair or exchange of a defective product, all of
which are expressly excluded from this limited warranty. This limited warranty does not cover any liability for
consequential or incidental damages, all of which are hereby expressly disclaimed, or the extension beyond the
duration of this limited warranty of any implied limited warranties, including those of merchantability or fitness for
an intended purpose. (Some states or provinces do not allow the exclusion or limitation of implied limited
warranties, so this exclusion may not apply to you.)
This limited warranty gives you specific legal rights. You may have other statutory rights that vary from state to
state or from province to province, in which case this limited warranty does not affect such statutory rights.
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.americanstandard.com.mx
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

American Standard Bathroom Aids ICU Sink System User manual

Category
Sanitary ware
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI