MULTIPLEX Comet Operating instructions

Type
Operating instructions
Page 1 of 35
Premix / Postmix / Beer
User manual
Installation and Service
Countertop and undercounter cooler
Python cooler
Comet 50 / 90 / 150 / 240
Comet 90 S / 150 S / 240 S
Comet 35 S / 75 S / 90 S / 100 S
Comet 35 / 75 / 100 / 125
Comet Tropical
Merkur 35 / 75 / 100 / 125
Merkur 50 V / 100 V
Python 25 / 35 / 75
Python 35 S / 75 S / 100 S
Page 2 of 35
Dear Customer!
Please keep this operating instructions carefully!
Examine the equipment immediately after supply for transport damages. Contact the
manufacturer and/or carrier if necessary. Damage, which arises by inappropriate treatment
or operation, is not subject of guarantee.
Scotsman Beverage Systems constantly develop the products further according to it´s
policies. Scotsman Beverage Systems reserve therefore the right, to modify and to improve
the products described in this documentation without previous announcement.
© 2004 Scotsman Beverage Systems. All rights reserved.
Reproduction of any kind without previously written permission of Scotsman Beverage
is not allowed.
Comet, Comet Tropical, MaxIce, Merkur and Python are brands of Scotsman Beverage
Systems. All Other brand names specified in this documentation refer to the appropriate
companies or their products. Scotsman Beverage systems is not the owner of those brand
names.
Please read the operating instructions carefully before operating this unit
Page 3 of 35
Table of Contents
1) Technical Data………………………………………………….. Page 5
a) EU-Conformity…………………………………………….. Page 13
2) Safety instructions………………………………………………….Page 13
3) Installation Instructions……………………………………………..Page 15
a) Comet and Python…………………………………………..
Page 15
b) Merkur………………………………………........................Page 16
4) Methods of cleaning…………………………………………………Page 17
5) Fault diagnosis………………………………………………….......Page 18
6) Exploded drawings and spares lists……………………….……..Pages 19 -32
(Please look up appropriate lists on page 4)
7) Wiring diagram…………………………………………………..….Page 33
Page 4 of 35
Part numbers
Premix / Postmix MaxIce List
Comet 50 01-1297-... 3
Comet 90 01-1283-...01-1285-...01-2283-...01-2285-...
3
Comet 150 01-1284-...01-1286-...01-2284-...01-2286-...
3
Comet 240 01-1294-... 01-2294-... 2
Beer / Pem / Pom Gas split unit
Python/Comet 35 S/Comet90 S 01-1279-... 01-1283-... 01-1285-... 5
Comet 90 S MaxIce 01- 2283-... 01- 2285-... 5
Python/Comet 75 S /Comet 150 S 01-1281-... 01-1284-... 01-1286-... 5
Comet 150 S MaxIce 01- 2284-... 01- 2286-... 5
Comet 100 S/ 125 S/ 240S/ Python100S
01-1298-... 01-1300-... 01-1294-
...
5
Comet 240 S MaxIce 01- 2294-... 5
Beer
Comet Tropical 01-1279-2005 (1/5 HP) 7
Comet Tropical 01-1294-2005 (2/3 HP) 7
Comet Tropical 01-1294-2006 (2/3 HP) 7
Comet Tropical 01-1294-2007 (2/3 HP) 7
Comet Tropical 01-1294-4006 (2/3 HP) 7
Beer
Comet 35 01-1279-… 01-1280... 4
Comet 75 01-1281-... 01-1282-... 4
Comet 100 01-1298-... 01-1299-... 1
Comet 125 01-1300-... 01-1301-... 1
Beer ( Beer- Pem ) 50 Hz For use outside FRG
Comet 75 01-1284-... 01-1286-... K... 3
Comet 100 01-1292-…01-1294-… K… 2
Comet 125 01-1295-… K… 2
Beer ( Beer ) 60 Hz For use outside FRG
Comet 75 01-1281-... 4
Comet 100 01-1298-... 1
Comet 125 01-1300-... 01-1301-... 1
Beer
Merkur 35 00-1352-... 00-1353-... 4
Merkur 75 00-1354-... 00-1355-... 4
Merkur 100 00-1361-... 00-1362-... 1
Merkur 125 00-1363-... 00-1364-... 1
Merkur 50 V 00-1335-... 6
Merkur 100 V 00-1365-... 6
Python coolers
Python 25 01-1297-... 4
Python 35 01-1293-... 01-1279-00.. 4
Python 75 01-1281-... 4
Python 100 01-1294- 4
Page 5 of 35
1.Technical Data
Comet 50
Voltage 230 V / 50 Hz
Power input 250 W
Compressor Danfoss TL4GX
Compressor classification cm
3
(HP) 4 (1/6 )
Cooling capacity ? 138 W
Refrigerant charge 140g R134a
Ice bank 2 Kg
Waterbath volume ca. 7 l
Height 360 mm
Depth 285 mm
Width 385 mm
Shipping weight ca. 20 kg
? Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 90
Voltage 230 V / 50 Hz
Power input 350 W
Compressor Danfoss FR 7,5 GX
Compressor classification cm
3
(HP) 7,5 (1/5 )
Cooling capacity ? 261 W
Refrigerant charge 200g R134a
Ice bank 5 Kg
Waterbath volume ca. 16 l
Height (MaxIce in Brackets) 405 mm (415mm)
Depth 326 mm
Width 500 mm
Shipping weight ca. 31 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 150
Voltage 230 V / 50 Hz
Power input 600 W
Compressor Danfoss FR 11 GX
Compressor classification cm
3
(HP) 11 (1/3)
Cooling capacity ? 395 W
Refrigerant charge 225g R134a
Ice bank 7 Kg
Waterbath volume ca. 19 l
Height (MaxIce in Brackets) 450 mm (460mm)
Depth 326 mm
Width 500 mm
Shipping weight ca. 33 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 6 of 35
Comet 240
Voltage 230 V / 50 Hz
Power input 760 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 684 W
Refrigerant charge 340g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height (MaxIce in Brackets) 555 mm (568mm)
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 90 S / Python 35 S / Comet 35 S Gas Split Unit
Voltage 230 V / 50 Hz
Power input 100 W
Height (MaxIce in brackets) 405 mm (415mm)
Depth 326 mm
Width 400 mm
Shipping weight ca. 20 kg
Comet 150 S / Python 75 S / Comet 75 S Gas Split Unit
Voltage 230 V / 50 Hz
Power input 100 W
Height (MaxIce in brackets) 450 mm (460mm)
Depth 326 mm
Width 400 mm
Shipping weight ca. 21 kg
Comet 240 S / 125 S / 100 S / Python 100 S Gas Split Unit
Voltage 230 V / 50 Hz
Power input 100 W
Height (MaxIce in brackets) 555 mm 568mm)
Depth 405 mm
Width 620 mm
Shipping weight ca. 35 kg
Page 7 of 35
Comet 35 / Merkur 35
Voltage 230 V / 50 Hz
Power input 350 W
Compressor Danfoss FR 7,5 GX
Compressor classification cm
3
(HP) 7,5 (1/5)
Cooling capacity ? 420 W
Refrigerant charge 200g R134a
Waterbath volume ca. 16 l
Height 405 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 31 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 75 / Merkur 75
Voltage 230 V / 50 Hz
Power input 600 W
Compressor Danfoss FR 11 GX
Compressor classification cm
3
(HP) 11 (1/3)
Cooling capacity ? 628 W
Refrigerant charge 225g R134a
Waterbath volume ca. 19 l
Height 450 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 33 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 100 / Merkur 100
Voltage 230 V / 50 Hz
Power input 750 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 1087 W
Refrigerant charge 320g R134a
Waterbath volume ca. 40 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 8 of 35
Comet 125 / Merkur 125
Voltage 230 V / 50 Hz
Power input 1000 W
Compressor Danfoss SC 21 GX
Compressor classification cm
3
(HP) 21 (4/5)
Cooling capacity ? 1269 W
Refrigerant charge 410g R134a
Waterbath volume ca. 40 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 55 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Merkur 50 V
Voltage 230 V / 50 Hz
Power input 470 W
Compressor Danfoss SC 12 GX
Compressor classification cm
3
(HP) 12 (3/8)
Cooling capacity ? 785 W
Refrigerant charge 275g R134a
Waterbath volume ca. 20 l
Height 450 mm
Depth 385 mm
Width 570 mm
Shipping weight ca. 51 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Merkur 100 V
Voltage 230 V / 50 Hz
Power input 830 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 1087 W
Refrigerant charge 300g R134a
Waterbath volume ca. 20 l
Height 515 mm
Depth 385 mm
Width 570 mm
Shipping weight ca. 53 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 9 of 35
Comet 75 Exp. 50Hz
Voltage 230 V / 50 Hz
Power input 600 W
Compressor Danfoss FR 11 GX
Compressor classification cm
3
(HP) 11 (1/3)
Cooling capacity ? 395 W
Refrigerant charge 225g R134a
Ice bank 7 Kg
Waterbath volume ca. 19 l
Height 450 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 33 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 100 Exp. 50Hz
Voltage 230 V / 50 Hz
Power input 760 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 684 W
Refrigerant charge 340g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 125 Exp. 50Hz
Voltage 230 V / 50 Hz
Power input 1000 W
Compressor Danfoss SC 21 GX
Compressor classification cm
3
(HP) 21 (4/5)
Cooling capacity ? 793 W
Refrigerant charge 410g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 51 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 10 of 35
Comet 75 Exp. 60Hz
Voltage 230 V / 60 Hz
Power input 600 W
Compressor Danfoss SC 10 GH
Compressor classification cm
3
(HP) 10 (1/3)
Cooling capacity ? 352 W
Refrigerant charge 250g R134a
Ice bank 7 Kg
Waterbath volume ca. 19 l
Height 450 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 33 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 100 Exp. 60Hz
Voltage 230 V / 60 Hz
Power input 760 W
Compressor Lunite CAE4440Y
Compressor classification cm
3
(HP) 12 (3/8)
Cooling capacity ? 428 W
Refrigerant charge 350g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet 125 Exp. 60Hz
Voltage 230 V / 60 Hz
Power input 1000 W
Compressor Danfoss SC 21 GX
Compressor classification cm
3
(HP) 21 (4/5)
Cooling capacity ? 793 W
Refrigerant charge 410g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 51 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 11 of 35
Comet Tropical
Voltage 230 V / 50 Hz
Power input 350 W
Compressor Danfoss FR 7,5 GX
Compressor classification cm
3
(HP) 7,5 (1/5)
Cooling capacity ? 261 W
Refrigerant charge 200g R134a
Waterbath volume ca. 16 l
Height 405 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 31 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Comet Tropical
Voltage 230 V / 50 Hz
Power input 760 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 684 W
Refrigerant charge 340g R134a
Waterbath volume ca. 40 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= -10°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Python 25 Python cooler
Voltage 230 V / 50 Hz
Power input 204 W
Compressor Danfoss FR 4 GX
Compressor classification cm
3
(HP) 4 (1/6)
Cooling capacity ? 222 W
Refrigerant charge 140g R134a
Ice bank (optional) 2 Kg
Waterbath volume ca. 7 l
Height 360 mm
Depth 285 mm
Width 385 mm
Shipping weight ca. 20 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 12 of 35
Python 35 Python cooler
Voltage 230 V / 50 Hz
Power input 350 W
Compressor Danfoss FR 7,5 GX
Compressor classification cm
3
(HP) 7,5 (1/5)
Cooling capacity ? 420 W
Refrigerant charge 200g R134a
Ice bank (optional) 5 Kg
Waterbath volume ca. 16l
Height 405 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 26 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Python 75 Python cooler
Voltage 230 V / 50 Hz
Power input 600 W
Compressor Danfoss FR 11 GX
Compressor classification cm
3
(HP) 11 (1/3)
Cooling capacity ? 628 W
Refrigerant charge 225g R134a
Ice bank (optional) 7 Kg
Waterbath volume ca. 19 l
Height 450 mm
Depth 326 mm
Width 500 mm
Shipping weight ca. 30 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Python 100 Python cooler
Voltage 230 V / 50 Hz
Power input 760 W
Compressor Danfoss SC 18 GX
Compressor classification cm
3
(HP) 18 (2/3)
Cooling capacity ? 1087 W
Refrigerant charge 340g R134a
Ice bank 14 Kg
Waterbath volume ca. 38 l
Height 555 mm
Depth 405 mm
Width 620 mm
Shipping weight ca. 50 kg
?Data at evap. temp.. t
0
= 0°C , Condensing temp.. t
c
= 55°C und Ambient temp.. t
a
= 32°C
Page 13 of 35
1a. EU - Conformity
This unit complies with the guidelines, regulations of the EU
EU EMC guideline 89/336/EWG
EU LVD guideline 73/23/EWG (93/68/EWG)
EU guideline for machines 89/392/EWG
2. Safety Instructions
The units comply with the current standards and regulations of the EU and represent the
current standard of technology.
Safety during installation, operation and decommissioning can only be ensured by following
the instructions in this user manual.
Any work or maintenance must be conducted in accordance with the following safety
instructions.
Technical changes to safety or electrical devices or the mains lead are strictly forbidden.
Installation, maintenance and repair on this equipment must be carried out by suitably trained
personnel.
Only use genuine spare parts.
Non-compliance with these instructions may result in serious injury or death.
Scotsman Beverage Systems and its legal entities ensure no liability for damage caused by
the use of non genuine spare parts or by improper treatment of the equipment.
Ways the equipment should be used
The units are intended for use as a cooling and recirculation unit for syrups and carbonated
water to provide the correct conditioning for serving draught soft drinks and as such should
only be used for that purpose. There are NO other recommended uses for this equipment.
Carbon dioxide
Carbon dioxide leaks are potentially fatal if concentrations rise to dangerous levels, in view of
this installation should be regularly checked for integrity and the general area of installation
properly ventilated at all times.
See carbon dioxide warning at rear of booklet.
WARNING: THIS EQUIPMENT MUST BE EARTHED
Page 14 of 35
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code:
Green and Yellow Earth
Blue Neutral
Brown Live
As the Colours of the Wires in the Mains Lead of this Appliance may not correspond with the
Coloured Markings identifying the Terminals in the Plug to be fitted proceed as follows:
a) The wire which is coloured green and yellow MUST be connected to the terminal in the
plug that is marked with the letter ‚E™ or by the earth symbol, coloured green or
green and yellow or laser cut into the metal casing.
b) The wire which is coloured blue MUST be connected to the terminal in the plug that is
marked with the letter ‚N™ or coloured black.
c) The wire which is coloured brown MUST be connected to the terminal in the plug that is
marked with the letter ‚L™ or coloured red.
Rotating parts
Some components will rotate for a short period after the power to the unit has been switched
off. These components should be avoided until stationary.
Danger by low temperatures
The evaporation temperature in the hermetic circuit can achieve easily -10°C. Without
taking preventive steps this can be a potential source of accidents whilst cleaning or
maintenance of parts at such temperatures.
Heat
The compressor, condenser, high pressure refrigeration tubes and motors will become hot
during operation. Please avoid any contact to these parts during and after operation until they
have cooled down.
Sharp edges
Scotsman Beverage Systems try to avoid any sharp edges. Based on the methods of
production and the material used this can not always be guaranteed. Therefore handle the unit
with care to avoid possible cuts.
Page 15 of 35
3. Installation Instructions
NOTE: The unit should be installed and serviced by a suitably trained
person.
3a. Installation COMET and PYTHON
1. Unpack the unit and visually check it for any damages
2. Fill the waterbath with with clean water until the overflow
3. Connect the Python to the beverage outlet of the cooler.
4. Connect the beverage/syrup lines with the beverage inlet at the cooler
and the outlet of the beverage container or your Bag-in-Box pump.
5. Build up a gas supply to your beverage container/Bag-in-Box pump.
6. Check the unit and each connection for leakages.
7. Plug in mains plug.
8. Wait until the compressor has switched off
9. Devent the beverage lines by opening each valve until only beverage will
get dispensed.
10. Check once again every connection for leakages.
11. Insulate the beverage outlet at the cooler properly
12. Unit is now ready to operate
3b. Installation MERKUR
1. Unpack the unit and visually check it for any damages
2. Fill the waterbath with with clean water until the overflow
3. Connect the beer lines with the beer inlet at the cooler and the outlet of
the quick disconnect coupling.
4. Build up a gas supply to your quick disconnect coupling.
5. Connect the quick disconnect coupling to your Keg
6. Devent the beer lines by opening each valve until only beverage will get
dispensed.
7. Check the unit and each connection for leakages.
8. Plug in mains plug
9. Wait until the compressor has switched off.
10. Unit is now ready to operate
Page 16 of 35
4. Methods of cleaning
NOTE:
Persons performing Cleansing /Sanitizing operations MUST be competent
and fully trained in safe methods of use of Cleansing / Sanitizing Agents and
their applications.
Personal protective equipment should always be used
Do not use a water or steam hose to clean the unit whilst still installed.
It is important that all the vents and grills are kept clear (including condenser
grills where applicable) otherwise cooling performance decreases and the
system overheats.
Regarding the cleansing an sanitising procedure please refer to national/EU
regulations. For the UK please follow the below mentioned procedure:
TWICE ANNUALLY: By a competent service \ maintenance engineer
Isolate unit from mains electricity supply.
Clean sanitize the units cooling coils and product lines using proprietary
cleanser / sanitiser of the Alkaline Hypochlorite type in accordance with the
manufacturers recommendations. Or follow the direct cleaning
recommendations laid down by the syrup supplier.
ANNUALLY: By a competent service / maintenance engineer
Isolate unit from mains electricity supply.
Remove any extraneous debris from the unit or its casing preferably using a
vacuum cleaner or brush, including the heat dump.
Check unit for electrical safety.
Page 17 of 35
5. Fault Diagnosis
Kind of malfunction Reason Solution
Cooler switched off or not
connected to mains
electricity
Switch cooler on or insert
plug
Control damaged Change Control
Compressor defective
Change compressor (only
skilled persons)
Refrigerant leakage
Find and repair leakage and
refill circuit (only skilled
persons)
Waterbath empty
Refill the waterbath with
clean water until water level
reaches overflow
Dispense rate too high
Either reduce dispense rate
or install stronger machine
Beverages too warm
Condenser dirty or blocked
Clean condensor or take care
for a free air flow
Dispense rate too high Reduce dispense rate
Syrup too old or saturated Change syrup
Beverage is foaming
Beverages too warm
Look at section „Beverages
too warm”
CO
2
-cylinder empty Change CO
2
-cylinder
Pressure regulator is shut off
Open valve
Pressure regulator frozen
due to dispense rate too high
Either split CO
2
-feed to
several cylinders or install a
pressure regulator heating
Beverage plain (
not saturated
enough with CO2)
Mains water pressure higher
than CO
2
-pressure Modify pressure adjustments
Carbonator pump defect Exchange pump
Water valve shut off or
carbonator not connected to
mains water
Open valve or connect unit to
mains water
Level control defect Exchange level control
Valve dispenses only gas
Time-out of level control has
cut he carbonator pump off
Ensure that there are no
leakages and reset the Level
control by disconnecting the
mains plug and plug it back
Icebank or temperature
control defect change controls
Beverages are frozen
Agitator defect Change agitator
Beverage is too sweet Wrong brix adjustment at
dispense valve Modify brix adjustment
Page 18 of 35
6. Spares list with Drawing
Spares list 1
Pos.Nr.
PN Description
Comet 100
Merkur 100
Comet 125
Merkur 125
1 41-2824-13 Recirc pump
x x
85-0215-20 Agitator
x x
2 85-0066 Fan motor 10 W
x x
85-0131 Fan motor 16 W
x x
3 73-0224 Fan shroud
x x
73-0225 Fan shroud
x x
4 85-0211 Fan blade Ø 230
x x
85-0067 Fan blade Ø 254
x x
5 80-1022 Compressor 18 cm
3
x x
80-1034 Compressor 21 cm
3
x x
6 83-0644-20 Strain relief
x x x x
7 83-0645-40 Starting relay
x x
8 83-0642-20 Starting capacitor
x x
9 83-0645-50 Starting device cpl.
x x
10 83-0643-20 Cover
x x x x
11a 86-0830-100 Black box Icebank control
x x x x
11b 86-0833-100 Black box Combi control
x x x x
11c 86-0834-100
Black box Mech.
Thermostat
x x x x
12 73-0027 Rubber foot
x x x x
13 33-0102 Cap nut
x x x x
14 34-0031 Gasket
x x x x
Electrical components for other voltages/frequencies on request
Differences
Comet 125 01-1301-2002 Agitator 85-0215-20
Comet 125 01-1301-2003 / -4006 Recirc pump 41-2824-23
Comet 125 01-1300-4003 Recirc pump 41-1824-19
Comet 100 01-1298-0007 Recirc pump 41-2824-14
Comet 100 01-1299-4003 Recirc pump 41-1824-19
Comet 100 01-1298-4003 Recirc pump 41-1824-24
Page 19 of 35
Drawing
Page 20 of 35
Spares list 2
Pos.Nr
. PN Description
Comet 100 (01-1294-…K..)
Non FRG version
Comet 100 (01-1292-…K..)
Non FRG version
Comet 125 (01-1295-…K..)
Non FRG version
Comet 240
Comet 240 MaxIce
1 41-2824-6 Recirc pump
x x
41-2824-9 Recirc pump
x
41-2779-01 Recirc pump
x
41-3824-9 Recirc pump
x
2 85-0066 Fan motor 10 W
x x x x
85-0131 Fan motor 16 W
x
3 73-0224 Fan shroud
x x x x
73-0225 Fan shroud
x
4 85-0211 Fan blade Ø 230
x x x x
85-0067 Fan blade Ø 254
x
5 80-1022 Compressor 18 cm
3
x x x x
80-1034 Compressor 21 cm
3
x
6 83-0644-20 Strain relief
x x x x x
7 83-0645-40 Starting relay
x x x x
8 83-0642-20 Starting capacitor
x x x x
9 83-0645-50 Starting device cpl.
x
10 83-0643-20 Cover
x x x x x
11a 86-0830-100 Black box Icebank control
x x x x x
11b 86-0833-100 Black box Combi control
x x x x x
11c 86-0834-100 Black box Mech. Thermostat
x x x x x
12 73-0027 Rubber foot
x x x x x
13 33-0102 Cap nut
x x x x x
14 34-0031 Gasket
x x x x x
not
shown
83-0546-10 Trafo
Electrical components for other voltages/frequencies on request
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

MULTIPLEX Comet Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI