Watts 079 Installation guide

Type
Installation guide

This manual is also suitable for

Installation & Operation Manual
of4 ©203WattsRadiant
Floor Sensor 079
ReadthisManualBEFOREusingthisequipment.
Failuretoreadandfollowallsafetyanduseinformationcanresultin
personalinjury,propertydamage,ordamagetotheequipment.
KeepthisManualforfuturereference.
Itisyourresponsibilitytoensurethatthissensorissafelyinstalledaccordingtoall
applicablecodesandstandards.WattsRadiantisnotresponsiblefordamagesresulting
fromimproperinstallationand/ormaintenance.
TheFloorSensor079iscommonlyusedforfloortemperaturesensinginfloorheating
applications.Thethincasingallowsforretrofitinstallationbetweentilespacesifnecessary.
Thissensorisdesignedtoprovideathermostatwiththeabilitytomaintainaminimum
slabtemperature,orhelptolimitthemaximumslabtemperature.
Thin-Set or Thin-Pour Applications
Ifthefloorcovering
istobeinstalledovereitherathin-
setorthin-pourmaterialofsufficientdepth,thefloor
sensorcanbeplaceddirectlyintoeitherthethin-set
materialorthethin-pourmaterialandcoveredover.
Ensurethatthesensorislocatedinsuchaposition
thattheattachedwireisabletoreachtoasuitable
junctionlocation.Spliceswithinthethin-setorthin-pour
shouldbeavoidedtoensuretroublefreeoperation.Thesensorshouldbelocated
midway
betweentheheatingelementstoensureapropertemperaturereading.
Thin Floor Coverings (less than 3/8" (10 mm))
Ifathinfloorcoveringistobeinstalleddirectlytothe
subfloor,agroove/8"(4mm)wideby/6"(2mm)
deepcanbecutintothesurfaceofthesubfloorto
accommodatethewireforthesensor.Ensurethatthe
sensorislocatedinsuchapositionthattheattached
wireisabletoreachtoasuitablejunctionlocation.
Splicesunderthefloorcoveringshouldbeavoidedtoensuretroublefreeoperation.A
groove3/6"(5mm)wideby3/6"(5mm)deepby-3/4"(45mm)longshouldbecutto
accommodatethesensor.Thesensorshouldbelocatedmidwaybetweentheheating
elementstoensureapropertemperaturereading.
Thick Floor Coverings (greater than 3/8" (10 mm))
Ifathickfloorcoveringistobeinstalleddirectlytothesubfloor,agroove/8"(4mm)wide
by/6"(2mm)deepcanbecutintothebackoftheflooringmaterialtoaccommodatethe
wireforthesensor.Ensurethatthesensorislocatedinsuchapositionthattheattached
wireisabletoreachtoasuitablejunctionlocation.
Hardwood
Subfloor
Tiles
Thin-set
Electric
Cables
New Installations
IOM-WR-Floor
_
Sensor-079323 2of4
Splicesunderthefloorcoveringshouldbeavoidedto
ensuretroublefreeoperation.Agroove3/6"(5mm)wide
by3/6"(5mm)deepby-3/4"(45mm)longshouldbecut
toaccommodatethesensor.Thesensorshouldbelocated
midwaybetweentheheatingelementstoensureaproper
temperaturereading.
Ifitisnotpracticaltocutagrooveinthe
surfacecovering,followtheinstallationmethodusedforthinfloorcoverings.
Hardwood
Subfloor
Installing the Sensor to the Bottom of a Subfloor
Ifthesensoristobeinstalledtothebottomofasubfloor,cutapieceof"(25mm)thick
rigidinsulationintoa6"(50mm)by6"(50mm)square.
Agroove3/6"(5mm)wideby3/6"(5mm)deepby
-3/4"(45mm)longshouldbecutintotheinsulationto
accommodatethesensor.Placethesensorinthegroove
andsandwichthesensorbetweentheinsulationand
thesubfloor.Useasuitablefasteningmethodtoaffix
theinsulationtothesubfloor.
Subfloor
Tile Floor Coverings
IfaFloorSensor079istobeinstalledintoanexisting
tilefloorwithsufficientlylargegroutlines,thesensor
andwirecanbeinstalledinoneofthegroutlines
betweenthetiles.Selectalowtrafficareaofthefloor
thatismidwaybetweentheheatingelementsforthe
sensorlocation.Ensurethatthesensorislocated
insuchapositionthattheattachedwireisableto
reachtoasuitablejunctionlocation.Spliceswithin
thegroutshouldbeavoidedtoensuretroublefreeoperation.Removetheappropriate
groutlineandplacethesensorandwireinthefloor.Re-groutthearea.
Tiles
Thin-set
Subfloor
TheFloorSensor079issuppliedwith0’(3m)ofcable.Ifalongerlengthisrequired,24
AWGorlargerwirecanbesplicedontothetwowiresfromthesensor.Thesplicesshould
beproperlysolderedandprotectedinanaccessiblejunctionbox.Followthesensortesting
instructionsgiveninthisbrochureandthenconnectthewirestothecontrol.
Floor Sensor 079 Wiring
Floor Sensor 079 Testing
Retrofit Installations
Agoodqualitytestmetercapableofmeasuringupto5,000kΩ(kΩ=000Ω)isrequiredto
measurethesensorresistance.Inadditiontothis,theactualtemperaturemustbemeasured
witheitheragoodqualitydigitalthermometer,orifathermometerisnotavailable,asecond
sensorcanbeplacedalongsidetheonetobetestedandthereadingscompared.
Donotrunsensorwiresparalleltotelephoneorpowercables.Ifthesensorwiresare
locatedinanareawithstrongsourcesofelectromagneticinterference,shieldedcable
ortwistedpairshouldbeusedorthewirescanberuninagroundedmetalconduit.
Ifusingshieldedcable,theshieldwireshouldbeconnectedtotheComorComSen
terminalonthecontrolandnottoearthground.
3of4 ©203WattsRadiant
Firstmeasurethefloortemperatureusingthethermometer.DisconnecttheSandCom
wiresfromthethermostat.Usinganelectricalmeter,measuretheresistanceoftheS
andComwiresatthethermostatlocation.Usingthetemperatureversusresistance
table,estimatethetemperaturemeasuredbythesensor.Thesensormeasurementand
thermometerreadingsshouldbeclose.Ifthetestmeterreadsaveryhighresistance,there
maybeabrokenwire,apoorwiringconnectionoradefectivesensor.Iftheresistanceis
verylow,thewiringmaybeshorted,theremaybemoistureinthesensororthesensor
maybedefective.Totestforadefectivesensor,measuretheresistancedirectlyatthe
sensorlocation.Oncethetesthasbeencompleted,reconnecttheSandComwiresto
thethermostat.
Temperature vs. Resistance Table
Temperature Resistance
°F °C
-0 -23 8,08
-5 -2 00,22
0 -8 85,362
5 -5 72,98
0 -2 62,465
5 -9 53,658
20 -7 46,28
25 -4 39,93
30 - 34,558
35 2 29,996
40 4 26,099
45 7 22,763
50 0 9,900
55 3 7,436
60 6 5,3
65 8 3,474
70 2 ,883
75 24 0,50
80 27 9,299
Temperature Resistance
°F °C
85 29 8,250
90 32 7,334
95 35 6,532
00 38 5,828
05 4 5,20
0 43 4,665
5 46 4,84
20 49 3,760
25 52 3,383
30 54 3,050
35 57 2,754
40 60 2,490
45 63 2,255
50 66 2,045
55 68 ,857
60 7 ,689
65 74 ,538
70 77 ,403
75 79 ,28
Technical Data
WARNING:
This product contains chemicals
known to the State of California to cause cancer
and birth defects or other reproductive harm.
For more information: www.watts.com/prop65
Floor Sensor 079, extra
Literature ES-WR-Floor_Sensor-079,IOM-WR-Floor_Sensor-079
Packagedweight 0.lb.(50g)
Dimensions
3/6”ODx-/2”(5mmODx38mm)
SensorMaterial
36stainlesssteel,0’(3m)24AWG,300voltPVCinsulatedZipcord
Approvals CSACUS
Operatingrange -58to22°F(-50to05°C)
Sensor
NTCthermistor,0kΩ@77°F(25°C±0.2°C)ß=3892
Do not apply voltage to a sensor at any time as damage to the sensor may result.
A Watts Water Technologies Company
USA:Springeld,MO•Tel.(800)276-249•Fax:(47)864-86•www.wattsradiant.com
Canada:Burlington,ONT.•Tel.(905)332-4090•Fax:(905)332-7068•www.watts.ca
IOM-WR-Floor
_
Sensor-079324 ©203WattsRadiant
Hydronic System Electronic Controls and Thermostats Limited Warranty
WattsRadiant(theCompany)warrantsitshydronicsystemelectroniccontrolsandthermostats(theProduct)tobe
freefromdefectsinmaterialsandworkmanshipundernormalusageforaperiodofoneyearfromthedocumented
dateofinstallationoftheProduct.Intheeventofdefectswithinthewarrantyperiod,theCompanywillreplace
theProductwithoutcharge.Thisremedyisthesoleandexclusiveremedyforbreachofwarranty.Thiswarranty
istransferabletosubsequentowners.
UnderthisLimitedWarranty,theCompanywillprovidethefollowing:
Inordertomakeaclaim,youmust:
(a)ProvidetheCompanywithsufficientdetailsrelatingtothenatureofthedefect,theinstallation,thehistoryof
operation,andanyrepairsthatmayhavebeenmade.
(b)AttheCompany’sdiscretionandattheowner’sexpense,shiptheProducttotheCompanyortheCompany’s
localrepresentativeordistributor.
(c) ProvideproofthattheProductwasinstalledinaccordancewiththeapplicableProductInstallationManualand
anyspecialwrittendesignorinstallationguidelinesbytheCompanyforthisproject.
(d)ProvideproofthattheProductwasinstalledinaccordancewiththeNationalElectricalCode(NEC)orthe
CanadianElectricalCode(CEC),andallapplicablelocalbuildingandelectricalcodes.
(e) Providearetailsalesreceiptorproofofpurchase.
ThefollowingarenotcoveredbythisLimitedWarranty:
(a)Anyincidentalorconsequentialdamage,includinginconvenience,lossoftimeorlossofincome.
(b)
AnylaborormaterialsrequiredtorepairorreplacetheProductthatarenotauthorizedinwritingbytheCompany.
(c) Anylaborormaterialsrequiredtoremove,repairorreplacematerialsotherthantheProducts.
(d)AnyfreightordeliverycostsrelatedtotheProductoranyrelatedelectricalproducts.
WattsRadiantassumesnoresponsibilityunderthisLimitedWarrantyforanydamagetotheProductcausedby
anytradespeople,visitorsonthejobsite,ordamagecausedasaresultofpost-installationwork.ThisLimited
Warrantyshallbeinvalidatedbyanyabuse,misuse,misapplicationorimproperinstallationoftheProducts.The
staffattheCompanyisavailabletoansweranyquestionsregardingtheproperinstallationorapplicationofthe
Productatthistoll-freephonenumber:800-276-249(USA/International)or888-208-8927(Canada).Ifyouare
everindoubtaboutthecorrectinstallationproceduretofollow,oriftheProductappearstobedamaged,youmust
callusbeforeproceedingwiththeinstallationorproposedrepair.
WATTSRADIANTDISCLAIMSANYWARRANTYNOTPROVIDEDHEREIN,INCLUDINGANYIMPLIEDWARRANTY
OFMERCHANTABILITYORIMPLIEDWARRANTYOFFITNESSFORAPARTICULARPURPOSE.WATTS
RADIANTFURTHERDISCLAIMSANYRESPONSIBILITYFORSPECIAL,INDIRECT,SECONDARY,INCIDENTAL,
ORCONSEQUENTIALDAMAGESARISINGFROMOWNERSHIPORUSEOFTHISPRODUCT,INCLUDING
INCONVENIENCEORLOSSOFUSE.THEREARENOWARRANTIESWHICHEXTENDBEYONDTHEFACEOF
THISDOCUMENT.NOAGENTORREPRESENTATIVEOFWATTSRADIANTHASANYAUTHORITYTOEXTEND
ORMODIFYTHISWARRANTYUNLESSSUCHEXTENSIONORMODIFICATIONISMADEINWRITINGBYA
CORPORATEOFFICER.
Somestates/provincesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamagesandsome
states/provincesdonotallowlimitationsonhowlongimpliedwarrantiesmaylast.Therefore,theabovelimitations
orexclusionsmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrightsandyoumayalsohaveother
rights,whichvaryfromstatetostateorprovincetoprovince.SOFARASISCONSISTENTWITHAPPLICABLE
STATE/PROVINCIALLAW,ANYIMPLIEDWARRANTIESTHATMAYNOTBEDISCLAIMED,INCLUDINGIMPLIED
WARRANTIESOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSEARELIMITEDINDURATION
TOONEYEARFROMTHEDATEOFMANUFACTURE.
Effective: May,203.ThiswarrantyappliestoallProductspurchasedafterthisdate.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4