Hampton Bay HBI-4192-WH Operating instructions

Type
Operating instructions

This manual is also suitable for

Motion Sensing
Diecast Lantern
HB-4190 Series
Features
• Lightcomesonwhenmotionisdetected.
• Automaticallyturnslightoff.
• DuskAccentlighting.
• Photocellkeepsthelightoffduringdaylight
hours.
Requirements
• Thelightcontrolrequires120voltsAC.
• IfyouwanttouseManualMode,thecontrol
mustbewiredthroughaswitch.
• Some codes require installation by a
qualified electrician.
©2009 595-5770-06
OPERATION
*resetstoAutoModeatdawn.
SettheON-TIMEswitch
on the bottom of the
coverplatetoTEST.
TEST 1 510 MIN
SetON-TIMEswitchto
1,5,or10minutes.
1Second
OFFthen...
Manualmodeonlyworksat
nightbecausedaylightre-
turnsthesensortoAUTO.
Flipthelightswitchofffor
onesecondthenbackonto
togglebetweenAUTOand
MANUALMODE.
Manual mode works only
withtheON-TIMEswitchin
the1,5,or10position.
...backon.
Thispackageincludes:
• Lantern
• Easy to use universal mounting bracket
(X-Bar)
• Mountinghardware
• Wirenuts
Note:Whenrstturnedonwaitabout1
1
/
2
minutesforthecircuitrytocalibrate.
TEST
AUTO
MANUAL MODE
TEST 1 5 10 MIN
Mode: On-Time Works: Day Night
Test 5Seconds x x
Auto 1,5,or10Min x
Manual ToDawn* x
Accent 3,6Hr,toDawn x
2
595-5770-06
INSTALLATION
Forbestperformance,mountthextureabout
6feet(1.8m)abovetheground.
1.Remove
twonuts.
2.Remove
X-Bar.
Junction
Box
5.AttachX-Barto
junctionbox
Duetothesizeandweightofthexture,you
mayndithelpfultohaveanassistantholdthe
xtureinplacewhileconnectingthewires.
MAX
MIN
3.Tightenscrews
ngertight.
SENSITIVITY
4.Setsensitivityon
xturebacktothe
mid-position.
ON-TIME Switch at 1,
5, or 10 minutes
Mode Switching Summary
Flip light
switch off for
one second
then back on*
MANUAL MODE
AUTO
TEST
* Ifyougetconfusedwhileswitchingmodes,
turnthepoweroffforoneminute,thenback
on.Afterthecalibrationtimethecontrolwill
beintheAUTOmode.
Du a l Br i t e
®
Dimmer Control
Lightcomesonhalfbrightforselectedtimeaf-
terdusk(Off,3hr.,6hr.,untildawn).Selecting
OFFdisablesthisfeature.Themotionsensing
featureswillcontinuetoworkasdescribed
inthismanual.Ifmotionissensed,thelight
turnsonfullbrightfortheON-TIME(1,5,or
10minutes)thenreturnstodimmode.
WARNING: Turn power off at circuit
breaker or fuse.
3
595-5770-06
Recommended Grounding Method
Useagreenground“pigtail”(notprovided)and
twistoneendtogetherwiththebarexturewire
andtheboxgroundwire.Securewithawire
connector.Securetheotherendofthe“pigtail”
withtheGNDscrewontheX-bar.
Blacktoblack
Whitetowhite
WIRING
One Motion Light
Twist the junction box wires and the
xturewirestogetherasshownbelow.
Securewithwireconnectors.Ifyouhave
ametaljunctionbox,youmaynotneed
thegreen“pigtail”.Ifyouareunsureabout
thegroundingmethod,consultyourlocal
buildingcode.
Two Motion Lights
Black
White
Green
orBare
Light
Fixture
Black
White
Green
orBare
Light
Fixture
Light
Fixture
CAUTION: DO NOT connect the RED
wire unless you want to control other
lights from the motion sensor.
Note:Allwiringshouldberuninaccordance
with the National Electrical Code through
conduit or another acceptable means.
Contact a qualified electrician if there is
any question as to the suitability of the
system.
Connectthexturewirestothewiresinthe
junction box. Twist the wires together and
securewithwireconnectors.
4
595-5770-06
OPTIONAL WIRING
Thisxtureisprovidedwithasensorratedfor360Watts.Sincethextureisonlyrated100
Watts,260Wattsofadditionalloadmaybecontrolledbythissensor.
Whendeterminingwhataxtureisratedfor,donotsimplylookattheratingonthelight
bulbinthexture.Lookatthemarkingwhichspeciesthemaximumbulbwattageforwhich
thextureissuitable.
Onceyouhaveselectedthexturestobeconnectedanddeterminedtheirmaximumrat-
ings,addtheseratingsup.Forinstance,ifyouhave3xturesrated100Watts,150Watts,
and75Wattsrespectively,youhaveatotalloadof325Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture:Stripthemotion
sensor’sredwireandconnecttothestandardlight’sblackwire.Connectallwhitewires
together.Totalxtureratingsmustnotexceed360Watts(3.0A).
Wiring Diagram 2 When wiring to control another motion sensing light fixture (Mas-
ter / Slave):Striptheredwireinbothlightxtures.Connecttheredwireofthecontrolling
(master)xturetotheredandblackwiresofthecontrolled(slave)xture.Connectallwhite
wirestogether.Totalxtureratingsmustnotexceed360Watts(3.0A).
Wiring Diagram 3 When wiring so either motion light turns on both motion lights
(Master / Master):Striptheredwireinbothlightxtures.Connecttheredwireofonexture
totheredwireofthesecondxture.Note:Inmostinstallations,anadditionalwire(same
gaugeasexistinghousewire)willhavetobeinstalledinthehousetoconnectthetwox-
turesasmaster/master.Connectallwhitewirestogetherandallblackwirestogether.Total
xtureratingsmustnotexceed360Watts(3.0A).
Black
White
Green
orBare
Light
Fixture
Light
Fixture
(Standard)
Master Slave
Black
White
Green
orBare
Light
Fixture
Light
Fixture
Red
Red
Wiring Diagram 1 Wiring Diagram 2
Wiring Diagram 3
Master Master
Black
White
Red
Green
orBare
Light
Fixture
Light
Fixture
5
595-5770-06
COMPLETE THE INSTALLATION
Stuffthewiresintothejunctionbox.Make
surenoneofthewiresgetpinched.
Slidethextureontothe
mountingscrewsand
tightennuts.
❒ Installone 100 Wattmaximumlightbulb,or
three 60 Wattbulbsincandelabrastyle.
❒ Install the fixture top. Secure with
decorativescrews.
Aftercompletingthetestsonpage6,caulk
fixture mounting surfacewithsilicone
weathersealant.
Junction
Box
Model 4193 Glass Installation
❒ Model 4193 only: install the six pieces
ofglassbyslidingthemdownasshown.
The glass panels should rest upon the
cornerguidesoneachside,andagainst
therubberbumpersatthebottom.
Note:Aswithanyglass,handlewithcare.
Corner
Guides
RubberBumpers
6
595-5770-06
TESTING
Turn on the circuit breaker and light
switch.
NOTE: Sensorhasa1
1
/
2
minutewarmuppe-
riodbeforeitwilldetectmotion.When
rstturnedon,wait1
1
/
2
minutes.
Switchtheon-timetoTESTpositionand
Du a l Br i t e
®
switchtotheOFFposition.
Thedetectorislesssensitivetomotiondi-
rectlytowardsitandmoresensitivetoacross
motion.
Sensor
Motion
Least Sensitive Most Sensitive
Walkthroughthe coverage areanoting
whereyouarewhenthelightsturnon.
If you need to change the sensitivity,
temporarilyremovethextureandmake
theadjustment.Toomuchsensitivitymay
increasefalsetriggering.
SettheamountofTIMEyouwantthelight
tostayonaftermotionisdetected.(1,5,
or10minutes).
Settheamountoftimeafterduskyouwant
thelightsonaccentlevel.
TEST1510MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
•Objectsthatchangetemperaturerapidly,
suchasheating vents and air condition-
ers.Theseheatsourcescouldcausefalse
triggering.
•Areaswherepets or trafficmaytrigger
thecontrol.
•Nearby large, light-colored objects
reecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
30ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
6ft.
(1.8m)
180°
Motion
7
595-5770-06
SPECIFICATIONS
Range........... Up to 30 ft. (9.1 m)
[varieswithsurrounding
temperature]
SensingAngle..... Upto180°
ElectricalLoad..... See rating on xture
formaximumwattage
SensorCapacity ... Upto360Watts(3.0A.)
Maximum Tungsten
Incandescent
PowerRequirements 120VAC,60Hz
OperatingModes... TEST, AUTO, and
MANUALMODE
TimeDelay ....... 1,5,10minutes
Du a l Br i t e
®
Timer... Off,3,6hours,dusk-to
dawn
TheHamptonBayLightingCompanyreserves
the right to discontinue products and to
change specications at any time without
incurringanyobligationtoincorporatenew
featuresinproductspreviouslysold.
8
595-5770-06
SYMPTOM
Light stays on
continuously.
Light flashes
on and off.
POSSIBLE CAUSE
1. Thesensorispointedtoward
a heat source like an air
vent, dryer vent, or brightly-
paintedheat-reectivesurface.
(Reduce sensitivity.)
2. LightcontrolisinManualMode.
(Switch to Auto.)
3. Light control isin Du a l Br i t e
®
mode.
4. Sensitivityissettoohigh.(Re-
duce sensitivity.)
1. Light control is in the Test
mode and warming up.
(Flashing is normal under
these conditions).
2. Heatbeingreectedfromother
objects may be affecting the
sensor.(Reduce sensitivity.)
POSSIBLE CAUSE
1. Lightswitchisturnedoff.
2. Bulbislooseorburnedout.
3. Fuseisblownorcircuitbreaker
isturnedoff.
4. Daylight turn-off is in effect
(recheck after dark).
5. Incorrectcircuitwiring,ifthisis
anewinstallation.
1. Lightcontrolmaybeinstalled
inarelativelydarklocation.
2. Light control is in Test. (Set
control switch to an ON-TIME
position.)
1. Light control may be sensing
smallanimalsorautomobiletrafc
(Reduce sensitivity).
2. Sensitivityissettoohigh.(Re-
duce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
Ifyouexperienceaproblem,followthisguide.
No Service Parts Available for this Product
24
595-5770-06
CAUSE POSSIBLE
1. Ledétecteurdelacommande
d’éclairage pointe vers une
source de chaleur comme un
évent d’aération, un éventde
sécheuseouunesurfacepeinte
decouleurviverééchissantla
chaleur.(Réduisez la portée).
2. Lacommanded’éclairageesten
modeManuel(faites-la passer
au mode Auto).
3. La commande d’éclairageest
enmodeDu a l Br i t e
MD
.
4. Leréglage deportéeesttrop
élevé.(Réduisez la portée).
1. Lacommanded’éclairageesten
modeessaietseréchauffe.(Le
clignotement est normal dans
ces deux cas).
2.
La chaleur qui est rééchie par
d’autres objets peut affecter la
commanded’éclairage.
(Réduisez
la portée).
SYMPTÔME
La lampe
reste allumées
continuelle-
ment.
La lampe
clignote.
CAUSE POSSIBLE
1. L’interrupteurd’éclairageesten
positionhorscircuit.
2. L’ampouleauquartzestdesser-
réeougrillée.
3. Lefusibleducircuitasautéoule
disjoncteurestenpositionhors
circuit.
4. Lafonctiondemisehorscircuit
àlalumièredujourestengagée.
(Revérifier quand il fait nuit).
5. Mauvaiscâblage,s’ils’agitd’une
nouvelleinstallation.
1. La commande d’éclairage est
installéedansunendroitrelati-
vementsombre.
2. La commande d’éclairage est
enmode essai.(Placer l’inter-
rupteur ON-TIME à 1, 5 ou 10
minutes.)
1. Lacommanded’éclairagepeut
détecterdepetitsanimaux,des
arbresagitésparleventoula
circulationautomobile.(Rédui-
sez la portée).
2. Le réglage de portée est trop
élevé.(Réduisez la portée).
SYMPTÔME
La lampe ne
s’allume pas.
La lampe
s’allume le
jour.
La lampe
s’allume
sans raison
apparente.
GUIDE DE DÉPANNAGE
Sivouséprouvezdesdifcultés,suivreceguide.
Aucune pièce de rechange n’est disponible pour ce produit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Hampton Bay HBI-4192-WH Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI