  • Hello! I am an AI chatbot trained to assist you with the Lucent Technologies LambdaUnite Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
LambdaUnite
®
MultiService Switch
(MSS)
Release 6.2
Installation Guide
365-374-187
CC109600197
Issue 1
December 2005
Lucent Technologies - Proprietary
This document contains proprietary information of Lucent Technologies and
is not to be disclosed or used except in accordance with applicable agreements.
Copyright © 2005 Lucent Technologies
Unpublished and Not for Publication
All Rights Reserved
See notice on first page
This material is protected by the copyright and trade secret laws of the United States and other countries. It may not be reproduced,
distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable
agreements, contracts or licensing, without the express written consent of Lucent Technologies and the business management owner of the
material.
Trademarks
All trademarks and service marks specified herein are owned by their respective companies.
Notice
Every effort has been made to ensure that the information in this document was complete and accurate at the time of printing. However,
information is subject to change.
Declaration of Conformity
The Declaration of Conformity (DoC) for this product can be found in the MSS Applications and Planning Guide, chapter 9, section
“Conformity statements” or at: http://www.lucent.de/ecl.
Safety
Always observe the Safety Instructions given in chapter 1 when operating the system.
Ordering information
The order number of this document is 365-374-187 (Issue 1).
Technical support
Please contact your Lucent Technologies Local Customer Support Team (LCS) for technical questions about the information in this document.
Information product support
To comment on this information product online, go to http://www.lucent-info.com/comments or email your comments to [email protected].
See notice on first page
Lucent Technologies - Proprietary
See notice on first page
Contents
About this information product
Purpose
......................................................................................................................................................................................................... xxviixxvii
Reason for reissue
.................................................................................................................................................................................. xxviixxvii
Safety information
................................................................................................................................................................................. xxviixxvii
Intended audience
.................................................................................................................................................................................. xxviixxvii
How to use this information product
......................................................................................................................................... xxviixxvii
Conventions used
..................................................................................................................................................................................... xxixxxix
Related documentation
......................................................................................................................................................................... xxxixxxi
Related training
...................................................................................................................................................................................... xxxiiixxxiii
Intended use
............................................................................................................................................................................................. xxxiiixxxiii
Optical safety
........................................................................................................................................................................................... xxxivxxxiv
Technical documentation
................................................................................................................................................................ xxxviixxxvii
Technical support
................................................................................................................................................................................. xxxviixxxvii
Important information for self-installing customers
...................................................................................................... xxxviixxxvii
How to order
......................................................................................................................................................................................... xxxviiixxxviii
How to comment
................................................................................................................................................................................ xxxviiixxxviii
Part I: Physical and power installation
1 Safety
Overview
......................................................................................................................................................................................................... 1-11-1
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
iii
General notes on safety
Overview
......................................................................................................................................................................................................... 1-31-3
Structure of hazard statements
........................................................................................................................................................... 1-41-4
Basic safety aspects
.................................................................................................................................................................................. 1-71-7
Specific safety areas
Overview
....................................................................................................................................................................................................... 1-101-10
Laser safety
................................................................................................................................................................................................. 1-111-11
Optical circuit pack specifications
................................................................................................................................................ 1-141-14
Laser product classification
............................................................................................................................................................... 1-161-16
Electrostatic discharge
.......................................................................................................................................................................... 1-201-20
Safety requirements in specific deployment phases
Overview
....................................................................................................................................................................................................... 1-221-22
Transportation
............................................................................................................................................................................................ 1-231-23
Storage
........................................................................................................................................................................................................... 1-251-25
Installation
.................................................................................................................................................................................................... 1-271-27
Taking into operation
............................................................................................................................................................................ 1-291-29
Operation and maintenance
............................................................................................................................................................... 1-321-32
Taking out of operation
....................................................................................................................................................................... 1-371-37
2 General information
Overview
......................................................................................................................................................................................................... 2-12-1
Floorplan guidelines (ETSI-2 / NEBS-2000)
........................................................................................................................... 2-22-2
Technical data
............................................................................................................................................................................................... 2-52-5
EMC/ESD information
........................................................................................................................................................................... 2-62-6
WaveStar
®
CIT requirements .............................................................................................................................................................. 2-82-8
Running WaveStar
®
CIT with Windows
®
XP SP2 ............................................................................................................... 2-92-9
Required tools and test equipment
............................................................................................................................................... 2-122-12
Contents
.................................................................................................................................................................................................................................
iv
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
Mark descriptions .................................................................................................................................................................................... 2-142-14
Sequence of steps
.................................................................................................................................................................................... 2-152-15
3 Mechanical installation
Overview
......................................................................................................................................................................................................... 3-13-1
ETSI-2 installation
Overview
......................................................................................................................................................................................................... 3-33-3
Hardware items
............................................................................................................................................................................................ 3-43-4
Technical data for rack
........................................................................................................................................................................... 3-53-5
Eye bolts
.......................................................................................................................................................................................................... 3-83-8
Floor mounting
............................................................................................................................................................................................ 3-93-9
Top mounting
............................................................................................................................................................................................. 3-133-13
Rack extension (width)
........................................................................................................................................................................ 3-153-15
Rack extension (height)
....................................................................................................................................................................... 3-173-17
Rack adapter kit
....................................................................................................................................................................................... 3-193-19
Technical data for PDP
........................................................................................................................................................................ 3-223-22
MDIO terminal rail
................................................................................................................................................................................ 3-243-24
Technical data for subrack
................................................................................................................................................................. 3-253-25
Mounting the subracks into rack
................................................................................................................................................... 3-283-28
NEBS-2000 installation
Overview
....................................................................................................................................................................................................... 3-353-35
Hardware items
......................................................................................................................................................................................... 3-363-36
Technical data for rack
........................................................................................................................................................................ 3-373-37
Eye bolts
....................................................................................................................................................................................................... 3-403-40
Floor mounting
......................................................................................................................................................................................... 3-413-41
Top mounting
............................................................................................................................................................................................. 3-463-46
Rack extension (width)
........................................................................................................................................................................ 3-483-48
Contents
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
v
Rack extension (height) ....................................................................................................................................................................... 3-503-50
Rack adapter kit
....................................................................................................................................................................................... 3-523-52
Technical data for PDP
........................................................................................................................................................................ 3-553-55
Technical data for subrack
................................................................................................................................................................. 3-573-57
Mounting the subracks into rack
................................................................................................................................................... 3-603-60
4 System cabling and final assembly
Overview
......................................................................................................................................................................................................... 4-14-1
Power and ground cable installation
Overview
......................................................................................................................................................................................................... 4-64-6
Power wiring (External battery - PDP)
........................................................................................................................................ 4-74-7
Power wiring (PDP - PI/100)
........................................................................................................................................................... 4-114-11
Power wiring (PI/100 - Fan unit)
.................................................................................................................................................. 4-174-17
Ground wiring
........................................................................................................................................................................................... 4-214-21
Internal cable installation
Overview
....................................................................................................................................................................................................... 4-244-24
Cable management
.................................................................................................................................................................................. 4-254-25
Controller cable (CI-CTL Fan unit)
........................................................................................................................................ 4-284-28
Subrack alarm wiring
............................................................................................................................................................................ 4-314-31
Station alarm wiring
.............................................................................................................................................................................. 4-354-35
External cable installation
Overview
....................................................................................................................................................................................................... 4-394-39
STM-1e interface
..................................................................................................................................................................................... 4-404-40
STM-1e cable assembly instructions
........................................................................................................................................... 4-474-47
DS3/EC1 interface
.................................................................................................................................................................................. 4-504-50
Miscellaneous Discrete Inputs/Outputs (MDIs/MDOs)
................................................................................................... 4-544-54
User byte interfaces (G.703/V.11)
................................................................................................................................................. 4-594-59
Contents
.................................................................................................................................................................................................................................
vi
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
TI-DS1 Station clock I/O interface (100/110 ) ................................................................................................................. 4-634-63
TI-E1 Station clock I/O interface (120 )
.............................................................................................................................. 4-674-67
TI-E1 Station clock I/O interface (75 )
................................................................................................................................. 4-704-70
LAN 10/100 Base-T interface
......................................................................................................................................................... 4-734-73
Fiber cabling
Overview
....................................................................................................................................................................................................... 4-774-77
Optical circuit packs
.............................................................................................................................................................................. 4-784-78
Gigabit Ethernet circuit packs
......................................................................................................................................................... 4-874-87
Fiber engineering rules
........................................................................................................................................................................ 4-894-89
OP40-DCM cabling
............................................................................................................................................................................... 4-964-96
Application of attenuators
.................................................................................................................................................................. 4-974-97
Installation of doors and side cover plates
Overview
....................................................................................................................................................................................................... 4-984-98
Side cover plates
...................................................................................................................................................................................... 4-994-99
Rack doors
................................................................................................................................................................................................ 4-1024-102
5 Power, software and circuit pack installation
Overview
......................................................................................................................................................................................................... 5-15-1
Powering
Overview
......................................................................................................................................................................................................... 5-25-2
Switching on and testing the supply voltage
............................................................................................................................ 5-45-4
Fan unit test
................................................................................................................................................................................................... 5-85-8
Software and circuit pack installation
Overview
....................................................................................................................................................................................................... 5-115-11
WaveStar
®
CIT installation ............................................................................................................................................................... 5-125-12
Starting the WaveStar
®
CIT application ................................................................................................................................... 5-185-18
NE software installation
...................................................................................................................................................................... 5-195-19
Contents
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
vii
Circuit packs ............................................................................................................................................................................................... 5-335-33
Configuration rules
................................................................................................................................................................................. 5-395-39
Mounting the circuit packs
................................................................................................................................................................ 5-525-52
Physical installation check
................................................................................................................................................................. 5-605-60
6 Exit checklist Part I
Overview
......................................................................................................................................................................................................... 6-16-1
Physical and power installation exit checklist
......................................................................................................................... 6-26-2
Power supply measurements
............................................................................................................................................................... 6-36-3
Part II: NE provisioning and stand-alone installation test
7 NE provisioning
Overview
......................................................................................................................................................................................................... 7-17-1
NE login
Overview
......................................................................................................................................................................................................... 7-27-2
Connecting the WaveStar
®
CIT to the NE ................................................................................................................................. 7-37-3
NE login via OSI
....................................................................................................................................................................................... 7-77-7
NE login via TCP/IP
............................................................................................................................................................................. 7-117-11
Provisioning system parameters
Overview
....................................................................................................................................................................................................... 7-137-13
Changing the NE name (TID)
......................................................................................................................................................... 7-147-14
System parameters
.................................................................................................................................................................................. 7-167-16
LAN port configuration for TCP/IP access
............................................................................................................................. 7-227-22
NE password aging
................................................................................................................................................................................ 7-287-28
NE date and time
..................................................................................................................................................................................... 7-307-30
Mounting the CTL protection unit
............................................................................................................................................... 7-337-33
External timing inputs
.......................................................................................................................................................................... 7-347-34
External timing references
................................................................................................................................................................. 7-367-36
Contents
.................................................................................................................................................................................................................................
viii
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
System timing ............................................................................................................................................................................................ 7-397-39
8 Stand-alone test procedures
Overview
......................................................................................................................................................................................................... 8-18-1
LED test
........................................................................................................................................................................................................... 8-28-2
Alarm reporting tests
............................................................................................................................................................................... 8-38-3
NE synchronization test
......................................................................................................................................................................... 8-78-7
Optical power meter test
..................................................................................................................................................................... 8-108-10
Receiver sensitivity test
....................................................................................................................................................................... 8-148-14
DS3 transmission and protection test
......................................................................................................................................... 8-228-22
Optical port transmission test (daisy chain test)
.................................................................................................................. 8-308-30
XC and CTL protection test
............................................................................................................................................................. 8-368-36
9 Exit checklist Part II
Overview
......................................................................................................................................................................................................... 9-19-1
NE provisioning and stand-alone installation test exit checklist
.................................................................................. 9-29-2
Optical output power measurements
.............................................................................................................................................. 9-39-3
Part III: Network establishment and testing
10 Network establishment and testing
Overview
....................................................................................................................................................................................................... 10-110-1
Network establishment
Overview
....................................................................................................................................................................................................... 10-310-3
Connecting the fiber cables
............................................................................................................................................................... 10-410-4
Provision DCC
....................................................................................................................................................................................... 10-1210-12
WaveStar
®
CIT remote login test via DCC ......................................................................................................................... 10-1510-15
Line timing test setup
........................................................................................................................................................................ 10-1810-18
1+1 MSP/APS test setup
.................................................................................................................................................................. 10-2310-23
2-fiber MS-SPRing/BLSR test setup
........................................................................................................................................ 10-2910-29
Contents
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
ix
4-fiber MS-SPRing/BLSR test setup ........................................................................................................................................ 10-3610-36
SNCP/UPSR test setup
...................................................................................................................................................................... 10-4310-43
Test procedures
Overview
.................................................................................................................................................................................................... 10-5010-50
Line timing test
...................................................................................................................................................................................... 10-5110-51
1+1 MSP/APS test
............................................................................................................................................................................... 10-5410-54
2-fiber MS-SPRing/BLSR test
..................................................................................................................................................... 10-5910-59
4-fiber MS-SPRing/BLSR test
..................................................................................................................................................... 10-6510-65
SNCP/UPSR test
................................................................................................................................................................................... 10-7110-71
ONNS provisioning
Overview
.................................................................................................................................................................................................... 10-7810-78
Setting the IP address and ONNS system parameters of the SCN nodes
......................................................... 10-8110-81
Optical port provisioning for SCN
............................................................................................................................................ 10-8310-83
DCC provisioning for SCN
............................................................................................................................................................ 10-8510-85
Launching the WaveStar
®
CIT ONNS application for the first time ................................................................... 10-8710-87
ONNS test
Overview
.................................................................................................................................................................................................... 10-9010-90
Path creation test
................................................................................................................................................................................... 10-9410-94
Path restoration test
............................................................................................................................................................................. 10-9710-97
Path deletion test
................................................................................................................................................................................... 10-9810-98
1+1 protection test
............................................................................................................................................................................... 10-9910-99
11 Exit checklist Part III
Overview
....................................................................................................................................................................................................... 11-111-1
Network establishment and testing exit checklist
............................................................................................................... 11-211-2
Completion form
...................................................................................................................................................................................... 11-311-3
Contents
.................................................................................................................................................................................................................................
x
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
A Installation troubleshooting
Overview
........................................................................................................................................................................................................ A-1A-1
Power failure
................................................................................................................................................................................................ A-2A-2
Fan unit test failure
.................................................................................................................................................................................. A-4A-4
NE synchronization failure
................................................................................................................................................................. A-6A-6
CTL failure
................................................................................................................................................................................................... A-8A-8
CTL protection test failure
............................................................................................................................................................... A-10A-10
XC protection test failure
.................................................................................................................................................................. A-11A-11
Circuit pack alarm handling
............................................................................................................................................................ A-12A-12
LED test failure
....................................................................................................................................................................................... A-14A-14
Remote login failure
............................................................................................................................................................................. A-16A-16
Alarm handling
........................................................................................................................................................................................ A-19A-19
Switching off an NE
............................................................................................................................................................................ A-20A-20
Fiber cleaning
........................................................................................................................................................................................... A-21A-21
Replacing LC-type LBOs
.................................................................................................................................................................. A-23A-23
Removing the SFP modules
............................................................................................................................................................ A-24A-24
B Passive WDM (OEM equipment)
Overview
........................................................................................................................................................................................................ B-1B-1
Hardware items
........................................................................................................................................................................................... B-2B-2
PWDM technical data
............................................................................................................................................................................ B-3B-3
PWDM mounting
...................................................................................................................................................................................... B-4B-4
PWDM arrangements
.............................................................................................................................................................................. B-8B-8
PWDM cabling
........................................................................................................................................................................................... B-9B-9
C DCM (OEM equipment)
Overview
........................................................................................................................................................................................................ C-1C-1
DCM mounting
........................................................................................................................................................................................... C-2C-2
Contents
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
xi
DCM arrangements .................................................................................................................................................................................. C-3C-3
DCM cabling
................................................................................................................................................................................................ C-4C-4
DCM module interface
.......................................................................................................................................................................... C-5C-5
D Mixed configuration: LambdaUnite
®
MSS and Metropolis
®
ADM
Overview
........................................................................................................................................................................................................ D-1D-1
Mounting the Metropolis
®
PDP ...................................................................................................................................................... D-3D-3
Mounting the MADM subrack(s)
................................................................................................................................................... D-5D-5
Mounting a fan unit
................................................................................................................................................................................. D-7D-7
Mounting the airguide
............................................................................................................................................................................ D-9D-9
Mounting the LambdaUnite
®
MSS subrack .......................................................................................................................... D-10D-10
Mounting the circuit breakers
........................................................................................................................................................ D-13D-13
Mounting the anti-recirculation plate
......................................................................................................................................... D-14D-14
Result
............................................................................................................................................................................................................. D-15D-15
E Mixed configuration: LambdaUnite
®
MSS and Metropolis
®
DMX (High Capacity)
Overview
......................................................................................................................................................................................................... E-1E-1
Mounting the LambdaUnite
®
MSS subrack ............................................................................................................................. E-2E-2
Mounting the heat baffle
....................................................................................................................................................................... E-5E-5
Mounting the Metropolis
®
DMX (High Capacity) subrack ............................................................................................ E-6E-6
Mounting the anti-recirculation plate
............................................................................................................................................ E-7E-7
Result
................................................................................................................................................................................................................ E-9E-9
Glossary
Index
Contents
.................................................................................................................................................................................................................................
xii
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
List of tables
Part I: Physical and power installation
1 Safety
1-1 Optical circuit pack specifications
.............................................................................................................................. 1-141-14
1-2 Laser classes (FDA/CDRH regulations)
................................................................................................................. 1-171-17
1-3 Laser classes (IEC 60825-1 standard)
...................................................................................................................... 1-171-17
2 General information
2-1 Required tools
.......................................................................................................................................................................... 2-122-12
2-2 Required test equipment
.................................................................................................................................................... 2-122-12
2-3 Sequence of steps
.................................................................................................................................................................. 2-162-16
3 Mechanical installation
3-1 ETSI-2 rack specifications
................................................................................................................................................. 3-53-5
3-2 PDP specifications
................................................................................................................................................................ 3-223-22
3-3 Subrack specifications
........................................................................................................................................................ 3-253-25
3-4 NEBS-2000 rack specifications
.................................................................................................................................... 3-373-37
3-5 PDP specifications
................................................................................................................................................................ 3-553-55
3-6 Subrack specifications
........................................................................................................................................................ 3-573-57
4 System cabling and final assembly
4-1 Cable list
........................................................................................................................................................................................ 4-34-3
4-2 Available PI cables
............................................................................................................................................................... 4-114-11
4-3 Pin assignment (PI cables)
.............................................................................................................................................. 4-164-16
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
xiii
4-4 Available fan power cables ............................................................................................................................................. 4-174-17
4-5 Pin assignments (fan power cables)
........................................................................................................................... 4-184-18
4-6 Available controller cables
.............................................................................................................................................. 4-284-28
4-7 Pin assignments (Controller cable)
............................................................................................................................. 4-294-29
4-8 Available subrack alarm cables
.................................................................................................................................... 4-314-31
4-9 Pin assignments (subrack alarm cables)
.................................................................................................................. 4-324-32
4-10 Pin assignment (station alarm cable)
........................................................................................................................ 4-364-36
4-11 Connector/wire technical data (Single coax cable, STM-1e)
..................................................................... 4-414-41
4-12 Pin assignment (MDI/MDO cables)
.......................................................................................................................... 4-554-55
4-13 Pin assignment (user byte cables)
............................................................................................................................... 4-604-60
4-14 Pin assignment (DS1 station clock output cables, 100/110 )
................................................................ 4-634-63
4-15 Pin assignment (DS1 station clock input cables, 100/110 )
................................................................... 4-654-65
4-16 Pin assignment (E1 station clock output cables, 120 )
.............................................................................. 4-674-67
4-17 Pin assignment (E1 station clock input cables, 120 )
................................................................................ 4-684-68
4-18 Pin assignment (E1 station clock output cables, 75 )
................................................................................ 4-704-70
4-19 Pin assignment (E1 station clock input cables, 75 )
................................................................................... 4-714-71
4-20 Pin assignment (LAN cables, crossed)
.................................................................................................................... 4-744-74
4-21 Pin assignment (LAN cables, straight)
.................................................................................................................... 4-754-75
4-22 When to use a rack extension
....................................................................................................................................... 4-904-90
5 Power, software and circuit pack installation
5-1 Available circuit packs
....................................................................................................................................................... 5-335-33
5-2 Available interface modules
............................................................................................................................................ 5-355-35
5-3 Association between EP51 slots and ECI51 slots
............................................................................................. 5-425-42
5-4 Association between EP51 slots and ECI51 protection groups
................................................................ 5-445-44
List of tables
.................................................................................................................................................................................................................................
xiv
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
Part II: NE provisioning and stand-alone installation test
7 NE provisioning
7-1 Elements of the Settings tab
........................................................................................................................................... 7-207-20
7-2 Elements of the Date and Time screen
.................................................................................................................... 7-317-31
8 Stand-alone test procedures
8-1 Mean launched power ranges
........................................................................................................................................ 8-128-12
8-2 Receiver sensitivity
.............................................................................................................................................................. 8-198-19
Part III: Network establishment and testing
10 Network establishment and testing
10-1 Power input ranges of the optical circuit packs
................................................................................................. 10-810-8
B Passive WDM (OEM equipment)
B-1 PWDM specifications
........................................................................................................................................................... B-3B-3
B-2 Optical-channel allocations
............................................................................................................................................... B-8B-8
List of tables
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
xv
List of figures
Part I: Physical and power installation
1 Safety
1-1 Laser warning labels
............................................................................................................................................................ 1-111-11
1-2 ESD symbol
.............................................................................................................................................................................. 1-201-20
1-3 Climatic limits (transportation and storage)
......................................................................................................... 1-241-24
1-4 Climatic limits (operation)
............................................................................................................................................... 1-361-36
2 General information
2-1 Floorplan guidelines (top view)
...................................................................................................................................... 2-22-2
2-2 Floorplan guidelines (side view)
.................................................................................................................................... 2-32-3
2-3 Grounding scheme
................................................................................................................................................................... 2-62-6
2-4 ESP subrack bonding point
................................................................................................................................................ 2-72-7
3 Mechanical installation
3-1 Rack layout (ETSI-2 rack)
................................................................................................................................................. 3-63-6
3-2 Eye bolt mounting
................................................................................................................................................................... 3-83-8
3-3 Top/Bottom plate layout (ETSI-2 rack)
..................................................................................................................... 3-93-9
3-4 Floor mounting (ETSI-2 rack)
....................................................................................................................................... 3-113-11
3-5 Anchoring kit SE12150W-1 CC408414951
................................................................................................... 3-113-11
3-6 Mounting holes (ETSI-2 rack)
...................................................................................................................................... 3-133-13
3-7 Top mounting fixture (ETSI-2 rack)
......................................................................................................................... 3-143-14
3-8 Mounting the rack extension (width)
........................................................................................................................ 3-163-16
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
xvii
3-9 Rack extension height, 600 mm ................................................................................................................................... 3-183-18
3-10 Rack extension height, 750 mm
................................................................................................................................... 3-183-18
3-11 Rack line-up without rack extensions (width)
..................................................................................................... 3-203-20
3-12 Rack line-up with rack extensions (width)
............................................................................................................ 3-203-20
3-13 PDP layout
................................................................................................................................................................................. 3-233-23
3-14 Mounting the MDIO terminal rail
.............................................................................................................................. 3-243-24
3-15 Subrack mounting dimensions
...................................................................................................................................... 3-263-26
3-16 Subrack mounting
................................................................................................................................................................. 3-313-31
3-17 Fiber guide mounting
.......................................................................................................................................................... 3-333-33
3-18 Mounting positions (ETSI-2 rack)
.............................................................................................................................. 3-343-34
3-19 Rack layout (NEBS-2000 rack)
.................................................................................................................................... 3-383-38
3-20 Eye bolt mounting
................................................................................................................................................................ 3-403-40
3-21 Top/Bottom layout of plate (NEBS-2000 rack)
.................................................................................................. 3-413-41
3-22 Drilling template (NEBS-2000 rack)
........................................................................................................................ 3-423-42
3-23 Floor mounting (NEBS-2000 rack)
............................................................................................................................ 3-433-43
3-24 Anchoring kit (NEBS-2000 rack)
............................................................................................................................... 3-433-43
3-25 Shim plates (NEBS-2000 rack)
.................................................................................................................................... 3-453-45
3-26 Mounting holes (NEBS-2000 rack)
........................................................................................................................... 3-463-46
3-27 Top mounting fixture (NEBS-2000 rack)
............................................................................................................... 3-473-47
3-28 Mounting the rack extension (width)
........................................................................................................................ 3-493-49
3-29 Rack extension height, 600 mm
................................................................................................................................... 3-513-51
3-30 Rack extension height, 750 mm
................................................................................................................................... 3-513-51
3-31 Rack line-up without rack extensions (width)
..................................................................................................... 3-533-53
3-32 Rack line-up with rack extensions (width)
............................................................................................................ 3-533-53
3-33 PDP layout
................................................................................................................................................................................. 3-563-56
3-34 Subrack mounting dimensions
...................................................................................................................................... 3-583-58
3-35 Subrack mounting
................................................................................................................................................................. 3-633-63
List of figures
.................................................................................................................................................................................................................................
xviii
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
3-36 Fiber guide mounting .......................................................................................................................................................... 3-653-65
3-37 Mounting positions (NEBS-2000 rack)
................................................................................................................... 3-663-66
4 System cabling and final assembly
4-1 Cable block diagram
.............................................................................................................................................................. 4-24-2
4-2 PDP connection (power input cables)
......................................................................................................................... 4-74-7
4-3 Securing the power input cables
..................................................................................................................................... 4-94-9
4-4 Routing the power input cables
.................................................................................................................................... 4-104-10
4-5 PDP connection (PI cables)
............................................................................................................................................ 4-124-12
4-6 Routing the PI cables (PDP side)
................................................................................................................................ 4-134-13
4-7 Connecting the PI cables (PI/100 / subrack side)
............................................................................................. 4-154-15
4-8 Fan power cable
..................................................................................................................................................................... 4-184-18
4-9 Routing to the fan unit
....................................................................................................................................................... 4-194-19
4-10 Routing to the PIs
................................................................................................................................................................. 4-194-19
4-11 PDP grounding
........................................................................................................................................................................ 4-214-21
4-12 Office and subrack grounding
....................................................................................................................................... 4-234-23
4-13 Cable management (top access)
................................................................................................................................... 4-264-26
4-14 Cable management (bottom access)
........................................................................................................................... 4-274-27
4-15 Controller cable
...................................................................................................................................................................... 4-294-29
4-16 Routing of the controller cable
..................................................................................................................................... 4-304-30
4-17 Connectors of the subrack alarm cables
................................................................................................................. 4-324-32
4-18 Routing the subrack alarm cables (PDP side)
..................................................................................................... 4-334-33
4-19 Connections of the subrack alarm cables (PDP side)
..................................................................................... 4-334-33
4-20 Routing the subrack alarm cables (subrack side)
.............................................................................................. 4-344-34
4-21 Connector of the station alarm cable
........................................................................................................................ 4-364-36
4-22 Routing the station alarm cable
.................................................................................................................................... 4-384-38
4-23 Layout (Single coax cable, STM-1e)
........................................................................................................................ 4-404-40
4-24 Layout (Multi coax cable, STM-1e)
.......................................................................................................................... 4-414-41
List of figures
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
xix
4-25 STM-1e cabling with rack extension (width) ...................................................................................................... 4-424-42
4-26 STM-1e cabling without rack extension (width)
............................................................................................... 4-424-42
4-27 Mounting of the cable bracket
...................................................................................................................................... 4-444-44
4-28 STM-1e cabling with rack extension (width)
...................................................................................................... 4-454-45
4-29 Mounting of the cable bracket
...................................................................................................................................... 4-464-46
4-30 IMS assembly procedure
.................................................................................................................................................. 4-484-48
4-31 Crimp tool and die
............................................................................................................................................................... 4-494-49
4-32 Example of mounted ECI51 interface paddle board
....................................................................................... 4-514-51
4-33 DS3/EC1 cabling without rack extension (width)
............................................................................................ 4-534-53
4-34 Connector of the MDI/MDO cables
.......................................................................................................................... 4-554-55
4-35 Routing the MDI/MDO cable (subrack side)
...................................................................................................... 4-564-56
4-36 Routing via the MDIO terminal rail
.......................................................................................................................... 4-564-56
4-37 Connector of the user byte cables
.............................................................................................................................. 4-604-60
4-38 Routing the user byte cables
.......................................................................................................................................... 4-624-62
4-39 Connector of the 100/110 DS1 station clock output cables
................................................................. 4-634-63
4-40 Connector of the 100/110 DS1 station clock input cables
.................................................................... 4-654-65
4-41 Routing the station clock I/O cables
......................................................................................................................... 4-664-66
4-42 Connector of the 120 E1 station clock output cables
............................................................................... 4-674-67
4-43 Connector of the 120 E1 station clock input cables
................................................................................. 4-684-68
4-44 Routing the station clock I/O cables
......................................................................................................................... 4-694-69
4-45 Connector of the 75 E1 station clock output cables
................................................................................. 4-704-70
4-46 Connector of the 75 E1 station clock input cables
.................................................................................... 4-714-71
4-47 Routing the station clock I/O cables
......................................................................................................................... 4-724-72
4-48 CIT connection (LAN crossed)
.................................................................................................................................... 4-744-74
4-49 Routing LAN1 (User Panel)
........................................................................................................................................... 4-744-74
4-50 HUB connection (LAN straight)
.................................................................................................................................. 4-754-75
4-51 Routing LAN2, LAN3 and LAN4 (CI-CTL)
....................................................................................................... 4-764-76
List of figures
.................................................................................................................................................................................................................................
xx
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
/