Lucent Technologies Metropolis DMXplore Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Lucent Technologies Metropolis DMXplore Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Lucent Technologies - Proprietary
This document contains proprietary information of
Lucent Technologies and is not to be disclosed or used except in
accordance with applicable agreements
Copyright © 2004 Lucent Technologies
Unpublished and Not for Publication
All Rights Reserved
Metropolis
®
DMX
plore
Access Multiplexer
Release 2.0
Installation Manual
365-372-334 R2.0
C109536243
Issue 4
Copyright © 2004 Lucent Technologies. All Rights Reserved.
hThis material is protected by the copyright and trade secret laws of the United States and other countries. It may not be reproduced, distributed, or altered
in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing,
without the express written consent of Lucent Technologies and the business management owner of the material.
Notice
Every effort was made to ensure that this information product was complete and accurate at the time of printing. However, information is subject to change.
Mandatory customer information
This equipment is designed to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause interference to radio communications.
Operation of this equipment in a residence is likely to cause harmful interference, in which case, the user will be required to correct the interference at his own
expense.
Interference information: Part 15 of FCC rules
NOTE: This equipment has been tested and found to comply within the limits.
Security statement
In rare instances, unauthorized individuals make connections to the telecommunications network. In such an event, applicable tariffs require that the customer
pay all network charges for traffic. Lucent Technologies and its predecessors cannot be responsible for such charges and will not make any allowance or give
any credit for charges that result from unauthorized access.
Trademarks
3Com is a registered trademark of 3Com Corporation.
5ESS and Billdats are registered trademarks of Lucent Technologies in the United States and other countries.
Information Mapping is a registered trademark of Information Mapping, Inc.
Adobe and Acrobat are registered trademarks of Adobe Systems, Inc.
CLEI, CLLI, CLCI, and CLFI are trademarks of Telcordia Technologies, Inc.
COMMON LANGUAGE is a registered trademark of Telcordia Technologies, Inc.
CSA is a registered trademark of Canadian Standards Association.
IBM is a registered trademark of International Business Machines Corporation.
Intel and Pentium are registered trademarks of Intel Corporation.
Reader (Adobe Acrobat Reader) is a trademark of Adobe Systems, Inc.
UL is a registered trademark of Underwriters Laboratories Inc.
WaveStar and Metropolis are registered trademarks of Lucent Technologies, Inc.
Windows, Windows NT, Windows 2000, Windows XP, MS-DOS, and Microsoft are registered trademarks of Microsoft Corporation.
Limited warranty
For terms and conditions of sale contact your Lucent Technologies Account Team.
Ordering information
The ordering number for this document is 365-372-334 R2.0. To order this document, call 1-888-582-3688 (USA), 1-317-322-6616 (Canada, Asia, the Pacific
Region, China, Caribbean, Latin America, Europe, the Middle East, and Africa), or 1-317-322-6416 (all others). RBOC/BOC customers should process
document orders or standing order requests through their Company Documentation Coordinator. For more ordering information, refer to the “Ordering
Information” section in the “About This Information Product” section.
Support
Technical support
Lucent Technologies Customer Assistance Request Entry System (CARES) provides a technical assistance telephone number that is monitored 24 hours a day.
Technical assistance can be obtained by calling 1 866 LUCENT8 (continental U.S.) or +1 630 224 4672 for in-hours and emergency out-of-hours support.
Developed by Lucent Technologies.
CONTENTS
iii
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................................................................................................
Contents
............................................................................................................................................................................................................................................................
About this information product
Safety Information and Instructions
xxi
Related Documentation and Training xxviii
Documentation Ordering Information xxxi
Worldwide Services xxxiii
............................................................................................................................................................................................................................................................
Part I: Metropolis
®
DMX
plore
Access Multiplexer Physical
Installation and Powering
............................................................................................................................................................................................................................................................
1 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf
(Wall-Mount)
Overview
1-1
Planning 1-3
Connector References 1-7
Inspection 1-8
Metropolis
®
DMXplore Wall-Mount Shelf Installation 1-9
Power Cable Installation 1-18
DS1 Cable Installation 1-23
DS3 Cable Installation 1-27
Ethernet Cable Installation 1-30
Office Alarm Cable Installation 1-33
Miscellaneous (Environmental) Discrete Telemetry Cable Installation 1-37
OC-3/OC12 Main Optical Fiber Cable Installation 1-41
RS-232 Serial CIT Cable Installation 1-43
SYSCTL LAN Cable Installation 1-45
Final Operations 1-491-49
1-45
1-43
1-41
1-37
1-33
1-30
1-27
1-23
1-18
1-9
1-8
1-7
1-3
1-1
xxxiii
xxxi
xxviii
xxi
...........................................................................................................................................................................................................................................................
CONTENTS
iv
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
2 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf
(Rack-Mount)
Overview
2-1
Planning 2-3
Connector References 2-7
Inspection 2-8
Metropolis
®
DMXplore Rack-Mount Shelf Installation 2-9
Power Cable Installation 2-13
DS1 Cable Installation 2-18
DS3 Cable Installation 2-22
Ethernet Cable Installation 2-24
Office Alarm Cable Installation 2-26
Miscellaneous (Environmental) Discrete Telemetry Cable Installation 2-30
OC-3/OC12 Main Optical Fiber Cable Installation 2-34
RS-232 Serial CIT Cable Installation 2-37
SYSCTL LAN Cable Installation 2-39
Final Operations 2-43
............................................................................................................................................................................................................................................................
3 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf (Wall-Mount)
Overview
3-1
Description 3-2
Powering 3-3
Circuit Pack Compatibility 3-7
Removal of Cover 3-9
Initial Circuit Pack Installation 3-11
............................................................................................................................................................................................................................................................
4 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf (Rack-Mount)
Overview
4-1
Description 4-2
Powering 4-3
Circuit Pack Compatibility 4-7
Removal of Cover 4-8
Initial Circuit Pack Installation 4-114-11
4-8
4-7
4-3
4-2
4-1
3-11
3-9
3-7
3-3
3-2
3-1
2-43
2-39
2-37
2-34
2-30
2-26
2-24
2-22
2-18
2-13
2-9
2-8
2-7
2-3
2-1
...........................................................................................................................................................................................................................................................
CONTENTS
v
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
Part II: Metropolis
®
DMX
plore
Access Multiplexer Stand-Alone
Installation Tests
............................................................................................................................................................................................................................................................
5 Software Download and Circuit Pack Installation
Software Installation
5-4
Circuit Pack Installation 5-5
Use of WaveStar® CIT Software 5-8
A Short Tour of the Command Builder 5-14
Circuit Pack Firmware Version Verification 5-18
Metropolis
®
DMXplore Shelf Initialization 5-20
............................................................................................................................................................................................................................................................
6 Installation Tests
Overview
6-1
LBO Software Settings 6-4
Clearing Alarms 6-7
Local Equipment and Cross-connect Tests 6-9
LED Test 6-16
............................................................................................................................................................................................................................................................
7 Operational Tests
Overview
7-1
Office Alarm Test 7-4
Automatic Protection Switching and Alarm Test 7-9
Manual Switching Tests 7-12
Miscellaneous (Environmental) Discrete Telemetry Test 7-14
Final Operations 7-18
............................................................................................................................................................................................................................................................
Part III: Metropolis
®
DMX
plore
Access Multiplexer Ring Setup
and Testing
............................................................................................................................................................................................................................................................
8 Ring Setup and Testing: Integration Procedures
Overview
8-1
Fiber Installation 8-4
OC-3/OC12 Optical Transmission Test 8-11
Automatic Protection Switching Test 8-13
Manual Switching Tests 8-158-15
8-13
8-11
8-4
8-1
7-18
7-14
7-12
7-9
7-4
7-1
6-16
6-9
6-7
6-4
6-1
5-20
5-18
5-14
5-8
5-5
5-4
...........................................................................................................................................................................................................................................................
CONTENTS
vi
365-372-334 R2.0
Issue 4, November 2004
Cover Installation Wall-Mount 8-19
Cover Installation Rack-Mount 8-21
Final Operations 8-23
............................................................................................................................................................................................................................................................
Part IV: Metropolis
®
DMX
plore
Access Multiplexer
Supplementary Information and Installation Checklist
............................................................................................................................................................................................................................................................
A Laser Safety and Classifications
Overview
A-1
Laser Safety A-2
Laser Product Classification A-5
Metropolis
®
DMXplore Optical Specifications A-7
............................................................................................................................................................................................................................................................
B Fiber Cleaning
Overview
B-1
Equipment Requirements and Recommendations B-3
Safety Instructions B-4
Cleaning/Inspecting Optical Connectors B-5
............................................................................................................................................................................................................................................................
C Installing Fiber Connectors and LBOs
Overview
C-1
LBOs C-2
Fiber Connections C-5
............................................................................................................................................................................................................................................................
D Backplane Pin Replacement
Overview
D-1
Pin and Connector Background D-3
Repair Kits and Tools D-5
Simple Repair Methods D-6
Replacement Methods D-8
............................................................................................................................................................................................................................................................
E Installation Checklist
Overview
E-1
............................................................................................................................................................................................................................................................
F Fiber Labeling
Fiber Description
F-2F-2
E-1
D-8
D-6
D-5
D-3
D-1
C-5
C-2
C-1
B-5
B-4
B-3
B-1
A-7
A-5
A-2
A-1
8-23
8-21
8-19
...........................................................................................................................................................................................................................................................
CONTENTS
vii
365-372-334 R2.0
Issue 4, November 2004
Fiber Labels F-4
............................................................................................................................................................................................................................................................
GL Glossary
Acronyms and Abbreviations
GL-1
Terms and Definitions GL-17
F-4
GL-1
GL-17
...........................................................................................................................................................................................................................................................
CONTENTS
viii
365-372-334 R2.0
Issue 4, November 2004
FIGURES
ix
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................................................................................................
List of figures
About this information product
........................................................................................................................................................................
1 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf (Wall-
Mount)
1-1 Connector Types and Pinouts 1-7
1-2 Metropolis
®
DMXplore Shelf Wall-Mount (with Cover) 1-10
1-3 Mounting Screw 1-10
1-4 Wall Plate 1-11
1-5 Safety Ground Screw 1-12
1-6 Exploded Bay-Frame (23" Mounting Bracket) 1-14
1-7 Safety Ground Screw 1-15
1-8 Wall-Mount Bay-Frame Mounting Brackets 1-17
1-9 Power Connection 1-20
1-10 DS1 Access Panel Cable Connectors 1-25
1-11 DS1 Cable Routing 1-26
1-12 DS3 Access Panel Cable Connectors. 1-28
1-13 10/100Base-T Cable Installation 1-31
1-14 Office Alarm Cable Connections 1-35
1-15 Alarm Cable Routing 1-35
1-16 Miscellaneous Discrete Cable Connection 1-39
1-17 Miscellaneous Discretes and Office Alarm Cable Routing 1-40
1-18 Optical Fiber Routing 1-421-42
1-40
1-39
1-35
1-35
1-31
1-28
1-26
1-25
1-20
1-17
1-15
1-14
1-12
1-11
1-10
1-10
1-7
...........................................................................................................................................................................................................................................................
FIGURES
x
365-372-334 R2.0
Issue 4, November 2004
........................................................................................................................................................................
2 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf (Rack-
Mount)
2-1 Connector Types and Pinouts 2-7
2-2 Metropolis
®
DMXplore Rack-Mount Shelf (with Cover) 2-9
2-3 Mounting bracket position for 19 inch frame 2-10
2-4 Mounting bracket position for 23 inch frame 2-11
2-5 Safety Ground Screw 2-12
2-6 Rack-Mount Metropolis
®
DMXplore Connector 2-14
2-7 Power Connection 2-15
2-8 DS1 Access Panel Cable Connectors 2-20
2-9 DS3 Access Panel Cable Connectors 2-23
2-10 10/100Base-T Cable Installation 2-24
2-11 Alarm Designations (as shown on inside cover) 2-28
2-12 Office Alarm Cable Connections 2-28
2-13 MDI and MDO Designations (see inside cover) 2-31
2-14 Miscellaneous Discrete Cable Connection 2-32
2-15 Optical Fiber Routing 2-35
........................................................................................................................................................................
3 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf
(Wall-Mount)
3-1 Power Connections on Metropolis
®
DMXplore Access Panel 3-4
3-2 Wall-Mount Metropolis
®
DMXplore Shelf 3-8
3-3 Metropolis
®
DMXplore Shelf with cover 3-9
3-4 Rotated Cover 3-10
3-5 Pivot Pins 3-10
........................................................................................................................................................................
4 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf
(Rack-Mount)
4-1 Power Connections on Rack-Mount Metropolis
®
DMXplore Access Panel
4-4
4-2 Rack-Mount Metropolis
®
DMXplore Shelf Front View 4-74-7
3-10
3-10
3-9
3-8
3-4
2-35
2-32
2-31
2-28
2-28
2-24
2-23
2-20
2-15
2-14
2-12
2-11
2-10
2-9
2-7
...........................................................................................................................................................................................................................................................
FIGURES
xi
365-372-334 R2.0
Issue 4, November 2004
4-3 Rack-Mount Metropolis
®
DMXplore Shelf with cover 4-8
4-4 Cover Removal 4-9
4-5 Rotated Cover 4-9
4-6 Rack-Mount Metropolis
®
DMXplore shelf - cover down 4-10
........................................................................................................................................................................
5 Software Download and Circuit Pack Installation
5-1 WaveStar® CIT Banner 5-9
5-2 WaveStar® CIT Login Prompt 5-9
5-3 WaveStar® CIT Legal Notice 5-10
5-4 WaveStar® CIT Network View 5-10
5-5 TL1 View Type Selection 5-11
5-6 OSI Connection Type Selection 5-12
5-7 Network Element Login Prompt 5-12
5-8 Command Builder and Response Windows: 5-13
5-9 ent-t1 (sb): Screen 1 5-14
5-10 ent-t1 (sb): Screen 2 5-15
5-11 ent-t1 (sb): Screen 3 5-16
5-12 ed-dat: Screen 1 5-17
........................................................................................................................................................................
6 Installation Tests
........................................................................................................................................................................
7 Operational Tests
7-1 Miscellaneous (Environmental) Discrete Functions 7-14
........................................................................................................................................................................
8 Ring Setup and Testing: Integration Procedures
8-1 Pivot Pins 8-19
8-2 Metropolis
®
DMXplore Shelf w. Cover 8-20
8-3 Rack-Mount Cover Alignment 8-21
8-4 Snapping cover into place 8-228-22
8-21
8-20
8-19
7-14
5-17
5-16
5-15
5-14
5-13
5-12
5-12
5-11
5-10
5-10
5-9
5-9
4-10
4-9
4-9
4-8
...........................................................................................................................................................................................................................................................
FIGURES
xii
365-372-334 R2.0
Issue 4, November 2004
........................................................................................................................................................................
A Laser Safety and Classifications
........................................................................................................................................................................
B Fiber Cleaning
B-1 Cleaning the Ferrule Endface B-6
B-2 CLETOP Cleaner B-7
B-3 Acceptability Criteria for Fiber Cleaning B-10
........................................................................................................................................................................
C Installing Fiber Connectors and LBOs
C-1 LC-type Connector Ports on Circuit Pack C-2
C-2 LC-type LBO C-3
C-3 LC-type LBO inserted into LC-type Connector Port C-3
C-4 Removing LC-type LBO from LC-type Connector Port C-4
C-5 LC-type Fiber Connector C-5
C-6 LC-type Fiber Connection C-6
........................................................................................................................................................................
D Backplane Pin Replacement
........................................................................................................................................................................
E Installation Checklist
........................................................................................................................................................................
F Fiber Labeling
Glossary
C-6
C-5
C-4
C-3
C-3
C-2
B-10
B-7
B-6
TABLES
xiii
365-372-334 R2.0
Issue 4, Novmeber 2004
...........................................................................................................................................................................................................................................................
List of tables
About this information product
1 Metropolis
®
DMXplore Documentation Set xxviii
2 Metropolis
®
DMXplore Drawings xxix
3 Ordering Documentation via Phone, Fax, or Email xxxi
4 Ordering Documentation via the Internet xxxi
........................................................................................................................................................................
1 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf (Wall-
Mount)
1-1 Cable Requirements and Options 1-5
1-2 Power Cable Assemblies 1-18
1-3 Power Connections 1-18
1-4 Power Cable Color Coding 1-20
1-5 DS1 Cable Assemblies 1-23
1-6 DS1 Transmission Connections 1-24
1-7 DS3 Cable Assemblies 1-27
1-8 LAN 10/100 BaseT Cable Assemblies for Fast Ethernet 1-32
1-9 Office Alarm Cable Assemblies 1-33
1-10 Office Alarm Connections 1-34
1-11 Miscellaneous Discrete Cable Assemblies 1-37
1-12 Miscellaneous (Environmental) Discrete Telemetry Connections 1-38
1-13 Serial CIT Cable Assembly 1-43
1-14 Standard CIT Cable Connection 1-43
1-15 RJ-45 to DB-9 Connector Connections 1-441-44
1-43
1-43
1-38
1-37
1-34
1-33
1-32
1-27
1-24
1-23
1-20
1-18
1-18
1-5
xxxi
xxxi
xxix
xxviii
...........................................................................................................................................................................................................................................................
TABLES
xiv
365-372-334 R2.0
Issue 4, Novmeber 2004
1-16 LAN 10BASE-T Cable Assemblies 1-45
1-17 LAN 10BASE-T Cross-over Cable Connections 1-47
1-18 LAN 10BASE-T Straight-through Cable Connections 1-47
........................................................................................................................................................................
2 Equipment and Cable Installation for Metropolis
®
DMX
plore
Shelf (Rack-
Mount)
2-1 Cable Requirements and Options 2-5
2-2 Power Cable Assemblies 2-13
2-3 Power Connections 2-14
2-4 Power Cable Color Coding 2-15
2-5 DS1 Cable Assemblies 2-18
2-6 DS1 Transmission Connections 2-19
2-7 DS3 Cable Assemblies 2-22
2-8 LAN 10/100 BaseT Cable Assemblies for Fast Ethernet 2-25
2-9 Office Alarm Cable Assemblies 2-26
2-10 Office Alarm Connections 2-27
2-11 Miscellaneous Discrete Cable Assemblies 2-30
2-12 Miscellaneous (Environmental) Discrete Telemetry Connections 2-31
2-13 Serial CIT Cable Assembly 2-37
2-14 Standard CIT Cable Connection 2-37
2-15 RJ-45 to DB-9 Connector Connections 2-38
2-16 LAN 10BASE-T Cable Assemblies 2-39
2-17 LAN 10BASE-T Cross-over Cable Connections 2-41
2-18 LAN 10BASE-T Straight-through Cable Connections 2-41
2-19 2-42
........................................................................................................................................................................
3 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf
(Wall-Mount)
3-1 Metropolis
®
DMXplore Shelf Power Supply Requirements 3-3
3-2 Release 2.0 Circuit Pack Slot Compatibility 3-73-7
3-3
2-42
2-41
2-41
2-39
2-38
2-37
2-37
2-31
2-30
2-27
2-26
2-25
2-22
2-19
2-18
2-15
2-14
2-13
2-5
1-47
1-47
1-45
...........................................................................................................................................................................................................................................................
TABLES
xv
365-372-334 R2.0
Issue 4, Novmeber 2004
........................................................................................................................................................................
4 Powering and Initial Circuit Pack Installation for Metropolis
®
DMX
plore
Shelf
(Rack-Mount)
4-1 Metropolis
®
DMXplore Shelf Power Supply Requirements 4-3
4-2 Release 2.0 Circuit Pack Slot Compatibility 4-7
........................................................................................................................................................................
5 Software Download and Circuit Pack Installation
........................................................................................................................................................................
6 Installation Tests
........................................................................................................................................................................
7 Operational Tests
7-1 Office Alarm Connections 7-5
7-2 Miscellaneous (Environmental) Discrete Inputs Telemetry Connections 7-
15
........................................................................................................................................................................
8 Ring Setup and Testing: Integration Procedures
........................................................................................................................................................................
A Laser Safety and Classifications
A-1 Laser Classes A-6
A-2 Metropolis
®
DMXplore Optical Specifications A-7
........................................................................................................................................................................
B Fiber Cleaning
B-1 Required and Recommended Equipment and Materials B-3
........................................................................................................................................................................
C Installing Fiber Connectors and LBOs
........................................................................................................................................................................
D Backplane Pin Replacement
D-1 Backplane Locations of METRAL™ Pins D-4
D-2 Metral™ Pins D-5
........................................................................................................................................................................
E Installation Checklist
E-1 Installation Acceptance Checklist E-2
........................................................................................................................................................................
F Fiber Labeling
E-2
D-5
D-4
B-3
A-7
A-6
7-5
4-7
4-3
...........................................................................................................................................................................................................................................................
TABLES
xvi
365-372-334 R2.0
Issue 4, Novmeber 2004
Glossary
xvii
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
About this information product
Purpose This document provides the information and procedures necessary to
install, self-test and turn up the Metropolis
®
DMXplore Access
Multiplexer system.
..................................................................................................................
Reason for reissue This document is reissued to include the OC12 OLIU VLNC 25 and
VLNC 26 circuit packs as well as the VLNC15 Fast Ethernet circuit
pack which provides functionality of 10/100 Base T introduced with
software Release 2.0.
..................................................................................................................
Intended Audience This installation manual is intended to provide information and
procedures necessary to install, self-test, and turn up the Metropolis
®
DMXplore system.
This manual is not a service or operations manual. Refer to 365-372-
332, Metropolis
®
DMXplore Access Multiplexer User Operations
Guide for any activities involving circuit turn-up or regular
maintenance, and 365-372-333, Metropolis
®
DMXplore Access
Multiplexer Alarm Messaging and Trouble Clearing Guide for trouble
analysis.
..................................................................................................................
...........................................................................................................................................................................................................................................................
About this information product
xviii
365-372-334 R2.0
Issue 4, November 2004
How to use this
information product
This manual is divided into the following sections with a brief
description of the contents of each major part/chapter/appendix:
“About This Document” describes the purpose, intended audience,
reason for reissue, and organization of this document. This section
references related documentation and explains how to order, make
comments or recommend changes to this document.
Part I: Metropolis
®
DMXplore Access Multiplexer Physical Installation
and Powering
Chapter 1, Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Wall-Mount) and Chapter 2, Equipment and
Cable Installation for Metropolis
®
DMXplore Shelf (Rack-Mount)
provide the information and procedures for installing and cabling
the Metropolis
®
DMXplore system. This section contains the
latest information at the time of issue. For up-to-date information,
refer to the SD and ED drawings listed in those chapters.
Chapter 3, Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXplore Shelf (Wall-Mount) and Chapter 4,
Powering and Initial Circuit Pack Installation for Metropolis
®
DMXplore Shelf (Rack-Mount) provide information for verifying
that the shelf is being supplied with the proper power and provides
instructions for circuit pack installation.
Part II: Metropolis
®
DMXplore Access Multiplexer Stand-Alone
Installation Tests
Chapter 5, Software Download and Circuit Pack Installation
covers generic software loading and initial circuit pack
installation, that is, placement of circuit packs in their proper
locations in the shelf.
Chapter 6, Installation Tests provides instructions to verify proper
transmission cabling installation and functionality.
Chapter 7, Operational Tests provides instructions to test
protection switching and the non-transmission cabling. This
section is not intended to replace acceptance test procedures.
Part III: Metropolis
®
DMXplore Access Multiplexer Ring Setup and
Testing
Chapter 8, Ring Setup and Testing: Integration Procedures
provides the tests to verify proper ring fiber cabling and protection
switching.
About this information product
...........................................................................................................................................................................................................................................................
xix
365-372-334 R2.0
Issue 4, November 2004
Part IV: Metropolis
®
DMXplore Access Multiplexer Supplementary
Information and Installation Checklist
Appendix A, Laser Safety and Classifications provides lightwave
and laser safety information and precautions.
Appendix B, Fiber Cleaning describes the Lucent recommended
method for the cleaning and inspection of optical connectors using
specific tools and materials that have been proven to be effective
in the assembly and testing of optical transmission equipment.
Appendix C, Installing Fiber Connectors and LBOs provides
procedures for installing and removing the types of Line Build
Out units (LBOs) and fiber connectors onto input and output ports
found on the Metropolis
®
DMXplore circuit packs.
Appendix D, Backplane Pin Replacement provides information
and the procedures used when a pin or blade on the Metropolis
®
DMXplore backplane has been bent or broken.
Appendix E, Installation Checklist provides a checklist to ensure
that all necessary procedures have been completed. Use of the
installation checklist is required to ensure a quality installation, all
completed tasks should be checked off and those not completed
should be duly noted as to the reason why. This checklist should
be turned in as part of your job complete paperwork.
Glossary provides definitions for telecommunication acronyms
and terms.
Index supplies users with specific subjects and corresponding
page numbers to find necessary information.
..................................................................................................................
...........................................................................................................................................................................................................................................................
About this information product
xx
365-372-334 R2.0
Issue 4, November 2004
Conventions Used Italic typeface denotes a particular product line or information product.
Helvetica Bold typeface signifies a window, section, command or
parameter used with the TL1 Command Builder.
Helvetica typeface indicates a faceplate or Metropolis
®
DMXplore
label designation, as in the ACTIVE LED on a circuit pack.
Courier Bold indicates a TL1 command typed in a terminal window by
the user, as in
act-user:LT-DMXplore:LUC01:ctag::DMXPLR2.5G;
Courier
typeface indicates the system or PC response to a command.
For the remainder of this document, “Metropolis
®
DMXplore” is used
in place of Metropolis
®