ZV1050SFSS

GE ZV1050SFSS , ZV1050SF3SS, ZV1050SF4SS, ZV1050SFSS Installation guide

  • Hello! I am an AI chatbot trained to assist you with the GE ZV1050SFSS Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
Installation
Instructions
monogram.com
42" Island
Vent Hood
ZV1050
2
Safety Information
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B.%HIRUHVHUYLFLQJRUFOHDQLQJXQLWVZLWFKSRZHURȺDW
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES
REGLES SUIVANTES :
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter
le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour éviter la mise
sous tension accidentelle. S’il n’est pas possible de
verrouiller le panneau du disconcteur, attacher un
placard ou une étiquette trés visible au panneau.
)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW
KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
ZLULQJPXVWEHGRQHE\TXDOL¿HGSHUVRQVLQ
accordance with all applicable codes and standards
LQFOXGLQJ¿UHUDWHGFRQVWUXFWLRQ

6XȻFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ
the heating equipment manufacturer’s guideline
and safety standards such as those published by the
1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$WKH$PHULFDQ
Society for Heating, Refrigeration and Air Conditioning
(QJLQHHUV$6+5$(DQGWKHORFDOFRGHDXWKRULWLHVWhen
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
/RFDOFRGHVYDU\,QVWDOODWLRQHOHFWULFDOFRQQHFWLRQVDQG
grounding must comply with applicable codes. In the
absence of local codes, the vent should be installed in
DFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH$16,1)3$
RUODWHVWHGLWLRQ
CAUTION: 7RUHGXFHULVNRI¿UHDQGWR
SURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRW
YHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
attics, crawl spaces or garages.
PRUDENCE : Il faut prendre soin
G·LQVWDOOHUXQFRQGXLWYHUVO·H[WpULHXUSRXUUpGXLUHOHULVTXH
d’incendie et pouvoir évacuer l’air correctement. Il ne faut
pas évacuer l’air correctement. Il ne faut pas évacuer l’air
dans l’espace entre les parois d’un mur, un plafond
ou un grenier, un espace sanitaire ou un garage.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
,03257$17 Save these instructions for local
inspector’s use.
,03257$17 Observe all governing codes and
ordinances.
 1RWHWR,QVWDOOHU Be sure to leave these instructions
with the Consumer.
 1RWHWR&RQVXPHU² Keep these instructions for
future reference.
 6NLOO/HYHO Installation of this vent hood requires basic
mechanical and electrical skills.
 &RPSOHWLRQWLPH WRKRXUV
 3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
covered under the Warranty.
CAUTION:
'XHWRWKHZHLJKWDQGVL]HRIWKLVYHQWKRRGDQGWRUHGXFH
the risk of personal injury or damage to the product, we
recommend at least three people install
this hood.
PRUDENCE :
À cause du poids et de la taille de la hotte et pour
réduire les risques de blessures ou de dommages de
l’équipement, nous recommandons que trois personnes
installent cette hotte.
WARNING:
7RUHGXFHWKHULVNRI¿UHRUHOHFWULFDOVKRFNGRQRWXVH
WKLVUDQJHKRRGZLWKDQ\H[WHUQDOVROLGVWDWHVSHHG
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create an
electrical safety hazard.
AVERTISSEMENT :
3RXUUpGXLUHOHULVTXHG·LQFHQGLHRXGHFKRFpOHFWULTXH
il ne faut pas utiliser cette hotte avec un régulateur
GHYLWHVVHpOHFWURQLTXHH[WHUQH7RXWHPRGL¿FDWLRQGH
ce type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
3
Design Information
PRODUCT DIMENSIONS
7KLVYHQWKRRGLVGHVLJQHGWREHXVHGLQYHQWHGFHLOLQJ
mounted installations. It can be installed over any Mono
JUDPFRRNWRSRUUDQJHLQFOXGLQJ3URIHVVLRQDOPRGHOV
CONTENTS
Design Information
3URGXFW'LPHQVLRQV ..............................................................................
'XFW&RYHU$FFHVVRULHV .................................................................. 
'HWHUPLQH,QVWDOODWLRQ+HLJKW .........................................................
$GYDQFH3ODQQLQJ
Tools and Materials Required ...........................................................5
3RZHU6XSSO\ ............................................................................................5
'XFW)LWWLQJV ..............................................................................................6
Installation Instructions
6WHS&RQVWUXFW&HLOLQJ6XSSRUW .............................................. ²
6WHS5HPRYH3DFNDJLQJ.............................................................. 
6WHS&KHFN,QVWDOODWLRQ+DUGZDUH .......................................... 
6WHS0RXQW7HPSODWH.................................................................... 
6WHS,QVWDOO6XSSRUW)UDPH ........................................................ 
Step 6, Secure Wiring ......................................................................... 
6WHS6L]HDQG,QVWDOO'XFWZRUN ................................................. 
6WHS,QVWDOO'HFRUDWLYH'XFW&RYHUV ...................................... 
6WHS,QVWDOO+RRG ............................................................................. 
6WHS&RQQHFW(OHFWULFDO ............................................................. 
6WHS6OLGH'XFW&RYHU'RZQ ................................................... 
6WHS,QVWDOO)LOWHUV)LQDOL]H,QVWDOODWLRQ .............................. 
10"
*Height
to Ceiling
42"
31-1/2"
WRDQIWFHLOLQJXVLQJVXSSOLHGGXFWFRYHU
32" for 9-ft. ceiling using ZX1059SFSS Accessory
44" for 10-ft. ceiling using ZX10510SFSS Accessory
This vent hood is supplied with a decorative duct cover
WRUHDFKIWFHLOLQJKHLJKWRUEHWZHHQDQG
DUCT COVER ACCESSORIES
$'XFW&RYHU$FFHVVRU\PD\EHUHTXLUHGIRU\RXUKRRG
LQVWDOODWLRQKHLJKW2UGHUDFFHVVRU\GXFWFRYHUVIRUIW
DQGIWFHLOLQJV
ZX1059SFSS –)RUIWFHLOLQJKHLJKW
This kit includes a decorative duct cover and support
IUDPHWRUHDFKDIWFHLOLQJKHLJKW
ZX10510SFSS –)RUIWFHLOLQJKHLJKW
This kit includes a decorative duct cover and support
IUDPHWRUHDFKDIWFHLOLQJKHLJKW
4
=9'XFW&RYHU'LPHQVLRQV
A B
ZV1050 11-1/2" 12"
ZX1059 19" 20"
ZX10510 25" 26"
Design Information
DUCT COVER ACCESSORIES
Order the accessory at the same time as the vent hood
DQGKDYHRQVLWHEHIRUHLQVWDOODWLRQEHJLQV
8VHWKLVFKDUWWRDFFXUDWHO\GHWHUPLQHWKHQHHGIRUD'XFW
Cover Accessory.
Installation Heights
Actual *Possible Hood
&HLOLQJ+HLJKW ,QVWDOODWLRQ+HLJKW 'XFW&RYHU
7'11" 29" Supplied
8'0" 30" Supplied
8'1" 30" Supplied
8'2" 25-1/2" to 30" ZX1059SFSS
8'3" 25-1/2" to 30" ZX1059SFSS
8'4" 25-1/2" to 30" ZX1059SFSS
8'5" 25-1/2" to 30" ZX1059SFSS
8'6" 25-1/2" to 30" ZX1059SFSS
8'7" 25-1/2" to 30" ZX1059SFSS
8'8" 25-1/2" to 30" ZX1059SFSS
8'9" 25-1/2" to 30" ZX1059SFSS
8'10" 25-1/2" to 30" ZX1059SFSS
8'11" 25-1/2" to 30" ZX1059SFSS
9'0" 25-1/2" to 30" ZX1059SFSS
9'1" 25-1/2" to 30" ZX10510SFSS
9'2" 25-1/2" to 30" ZX10510SFSS
9'3" 25-1/2" to 30" ZX10510SFSS
9'4" 25-1/2" to 30" ZX10510SFSS
9'5" 25-1/2" to 30" ZX10510SFSS
9'6" 25-1/2" to 30" ZX10510SFSS
9'7" 25-1/2" to 30" ZX10510SFSS
9'8" 25-1/2" to 30" ZX10510SFSS
9'9" 25-1/2" to 30" ZX10510SFSS
9'10" 25-1/2" to 30" ZX10510SFSS
9'11" 25-1/2" to 30" ZX10510SFSS
10'0" 25-1/2" to 30" ZX10510SFSS
DETERMINE INSTALLATION HEIGHT
*30"
Recommended
36" Min.
*9-ft. to 10-ft. ceilings may be 25-1/2" to 30" clearance.
7KHGLVWDQFHEHWZHHQWKHFRRNLQJVXUIDFHDQGWKHERWWRP
of the hood must be at least 25-1/2". The 30" recommended
LQVWDOODWLRQKHLJKWDERYHWKHVWDQGDUGµFRXQWHUWRSZLOO
HQVXUHGXFWFRYHU¿WWRWKHFHLOLQJ)RUIWDQGIWFHLO-
LQJKHLJKWVWKHKRRGPD\EHORZHUHGWRRYHUWKH
FRRNLQJVXUIDFH
:KHQLQVWDOOLQJWKH,VODQG+RRGDERYHD0RQRJUDP3URIHV-
sional Range or Rangetop, installation clearance must be
at least 30".
,03257$17&OHDUDQFHVPD\YDU\GXHWRW\SHRIFRRNLQJ
SURGXFWDQGORFDOFRGHV&KHFNZLWKORFDOLQVSHFWRUVWREH
sure standard is applicable.
DUCT COVER DIMENSIONS
5
$GYDQFH3ODQQLQJ
TOOLS AND MATERIALS REQUIRED
(not supplied)
7DSHPHDVXUH
.QLIH
6SLULWOHYHO
:LUHFXWWHU
:LUHVWULSSHU
:LUHQXWV
(OHFWULFGULOODQGELW
3KLOOLSVVFUHZGULYHU
)ODWEODGHVFUHZGULYHU
+DPPHU
3OLHUV
6DIHW\JODVVHV
7DSHWRPRXQWWHPSODWH
*ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV
9+]RU$PSZLUHZLWKJURXQGSURSHUO\
grounded branch circuit
6WUDLQUHOLHIIRUMXQFWLRQFRYHU
3OXPEERE
&HQWHUSXQFK
POWER SUPPLY
IMPORTANT – Please read carefully.
WARNING: FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
AVERTISSEMENT :
POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL DOIT
ÊTRE CORRECTEMENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWKWKLV
DSSOLDQFH)ROORZ1DWLRQDO(OHFWULFDO&RGHRUSUHYDLOLQJ
local codes and ordinances.
Electrical supply
7KLVYHQWKRRGPXVWEHVXSSOLHGZLWK9+]
connected to an individual, properly grounded branch
FLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLWEUHDNHU
RUWLPHGHOD\IXVH
:LULQJPXVWEHZLUHZLWKJURXQG
,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
requirements, call a licensed electrician before
proceeding.
5RXWHKRXVHZLULQJLQWKHFHLOLQJDVFORVHWRWKH
installation location as possible. Allow an additional
IHHWOHQJWKIURPFHLOLQJMRLVWVWRUHDFKWKHMXQFWLRQ
ER[RQWKHKRRG
&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQDFFRUGDQFH
with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipPHQWJURXQGLQJWHUPLQDORUOHDGRQWKHKRRG
WARNING: The improper connection
RIHTXLSPHQWJURXQGLQJFRQGXFWRUFDQUHVXOWLQDULVN
RIHOHFWULFVKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRU
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT :
/HPDXYDLVEUDQFKHPHQWGX¿OGHPLVHjODWHUUHSHXW
causer un choc électrique. En cas de doute, consulter
XQpOHFWULFLHQTXDOL¿pRXXQWHFKQLFLHQSRXUGpWHUPLQHU
VLO·DSSDUHLOHVWjODWHUUH
6
$GYDQFH3ODQQLQJ
DUCT FITTINGS
Total
(TXLYDOHQW 4XDQWLW\ (TXLYDOHQW
Duct Piece Dimensions Length* Used Length
5RXQG IW
VWUDLJKW SHUIRRW
OHQJWK
IW
[ SHUIRRW
VWUDLJKW OHQJWK
HOERZ IW
HOERZ IW
[
HOERZ IW
[
HOERZ IW
[
ÀDWHOERZ IW
URXQGWR
[WUDQVLWLRQ IW
[
WRURXQGWUDQVLWLRQ IW
URXQG
WR[
WUDQVLWLRQHOERZ IW
[WR
URXQGWUDQVLWLRQHOERZ IW
Round
wall cap
ZLWKGDPSHU IW
[ZDOOFDS
with damper 75 ft.
Round
URRIFDS IW
8VHWKLVFKDUWWRFRPSXWHPD[LPXP
permissible lengths for duct runs to
outdoors.
NOTE: 'RQRWH[FHHGPD[LPXPSHUPLV
sible equivalent lengths!
Maximum duct length: 100 ft. for
range hoods.
Flexible ducting:
,IÀH[LEOHPHWDOGXFWLQJLVXVHGDOO
the equivalent feet values in the table
VKRXOGEHGRXEOHG7KHÀH[LEOHPHWDO
duct should be straight and smooth and
H[WHQGHGDVPXFKDVSRVVLEOH
'RNOTXVHÀH[LEOHSODVWLFGXFWLQJ
7RWDO'XFW5XQ
NOTE: Any home ventilation system, such
as a ventilation hood, may interrupt the
SURSHUÀRZRIFRPEXVWLRQDLUDQGH[KDXVW
UHTXLUHGE\¿UHSODFHVJDVIXUQDFHV
gas water heaters and other naturally
vented systems. To minimize the chance
of interruption of such naturally vented
systems, follow the heating equipment
manufacturer’s guidelines and safety
standards such as those published by
1)3$DQG$6+5$(When applicable, install
DQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code
requirements. Visit GEAppliances.com
for available makeup air solutions.
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFW¿WWLQJHTXLYDOHQW(TXLYDOHQW
length of duct pieces are based on actual tests conducted by GE
(YDOXDWLRQ(QJLQHHULQJDQGUHÀHFWUHTXLUHPHQWVIRUJRRGYHQWLQJ
performance with any ventilation hood.
This Hood Must
Use 8" Round Duct.
It Can Transition to
3-1/4" x 12" Duct.
7
Installation Instructions
STEP 1 CONSTRUCT CEILING SUPPORT
Plan the location
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
8VHDSOXPEEREWRFKHFNORFDWLRQWREHVXUHFRXQWHUWRSFRRN
WRSORFDWLRQEHORZWKHKRRGZLOODOLJQH[DFWO\
7KHKRRGVKRXOGSURMHFWIRUZDUGEH\RQGWKHIURQWHGJHRI
the cooking appliance. See illustration.
2EVHUYHWKHUHFRPPHQGHGVSDFHEHWZHHQWKHFRRNLQJ
surface and bottom of hood.
Ceiling
Hood
Ducting
Centerline
Side View
Approx. 1-1/2"
Beyond Cooking
Surface
Cooktop
Countertop
31-1/2"
Hood
Front
15-3/4"
Ceiling support structure
$WWKHKRRGORFDWLRQLQVWDOO[FURVVIUDPLQJ
EHWZHHQFHLOLQJMRLVWVDVVKRZQ[VDUHUHTXLUHGWR
VXSSRUWWKHZHLJKWRIWKHKRRG
$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVW
ing structure.
<RXUFHLOLQJMRLVWVZLOOEHOLNHRQHRIWKHIROORZLQJ
H[DPSOHV
,QVWDOO&URVV)UDPLQJ
Symmetrically About
'XFW&RRNWRS&HQWHUOLQH

-RLVW
Spacing
[&URVV
)UDPLQJ
8" Duct
$OLJQ'XFWWR&HQ
ter of Cooktop
Cooktop
Outline
7RS9LHZ³&HLOLQJ-RLVWV3DUDOOHOWR)URQWRI+RRG
Front
of Hood
EXAMPLE A
8
Installation Instructions
STEP 1 CONSTRUCT CEILING SUPPORT (cont.)
$OLJQ'XFWWR
Center of Cooktop
Cooktop
Outline
7RS9LHZ³&HLOLQJ-RLVWV5XQ3HUSHQGLFXODUWR)URQWRI+RRG
Front
of Hood
EXAMPLE B
,QVWDOO&URVV)UDPLQJ
Symmetrically About
'XFW&RRNWRS&HQWHUOLQH
-RLVW
Spacing
[&URVV
)UDPLQJ

8" Duct
EXAMPLE C

[&URVV
)UDPLQJ
,QVWDOO
&URVV)UDPLQJ
Symmetrically About
'XFW&RRNWRS&HQWHUOLQH
8" Duct
-RLVW
Spacing
$OLJQ'XFWWR
Center of Cooktop
Cooktop
Outline
7RS9LHZ³&HLOLQJ-RLVWVDW$QJOHZLWK)URQWRI+RRG
Front
of Hood
9
Installation Instructions
STEP 1 CONTINUED
$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVWLQJ
VWUXFWXUH6HHH[DPSOHV
²6HFXUHHDFK[EORFNZLWKDWOHDVWIRXUZRRG
VFUHZVORQJQRWVXSSOLHG8VHZRRGVFUHZVWRWDO
for the two supports.
The cross-framing must be accurately aligned to
ensure correct positioning of the hood.
7KHFURVVIUDPLQJPXVWEHOHYHOLQDOOGLUHFWLRQV
Check with a spirit level and adjust if necessary.
IMPORTANT: The ceiling structure must be capable of sup-
porting the weight of the hood (approximately 300 pounds)
DQGDQ\LQDGYHUWHQWXVHUFRQWDFWORDGV7KHKRRGVXSSRUW
frame will be supported by the 2 x 4 min. cross-framing.
'XFWZRUN
8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH)RU
VDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRWH[FHHG
IHHWHTXLYDOHQWOHQJWKIRUDQ\GXFWFRQ¿JXUDWLRQ
5HIHUWR´'XFW)LWWLQJVµFKDUWWRFRPSXWHWKHPD[LPXP
permissible length for duct runs to the outdoors.
7KLVYHQWKRRGPXVWXVHURXQGGXFW7KHURXQG
GXFWFDQWUDQVLWLRQWR[
,QVWDOOWKHKRXVHGXFWZRUNWRUXQKRUL]RQWDOO\EHWZHHQ
ceiling joists or straight up through the roof.
Finish the Ceiling
)LQLVKWKHFHLOLQJVXUIDFH%HVXUHWRPDUNORFDWLRQRI
WKHFHLOLQJMRLVWVDQGFURVVIUDPLQJ&KHFNWREHVXUH
the ceiling is level; use shims, if necessary.
'HSHQGLQJRQDYDLODEOHVSDFH
10
Installation Instructions
STEP 2 REMOVE THE PACKAGING
The vent hood is packed separately from the decorative
GXFWFRYHURUDFFHVVRU\FRYHUV=;6)66RU
=;6)66
5HPRYHWKHIUDPHFRYHUSDUWVER[DQGSDFNDJLQJ
5HPRYHMXQFWLRQER[FRYHU
,QVWDOOVWUDLQUHOLHIRQWRMXQFWLRQER[FRYHU
STEP 3 CHECK INSTALLATION HARDWARE AND ACCESSORIES
/RFDWHWKHKDUGZDUHDFFHVVRU\SDFNVKLSSHGZLWKWKH
hood and check contents.
11-1/4”
TO CENTER LINE
OF HOLES
7-1/4” TO
CENTER LINE
OF HOLES
WIRE
HOLE
ACCESS
WIRE
HOLE
ACCESS
Mounting Screw Holes
2 Phillips-Head
'HFRUDWLYH6FUHZV
4 Filters
/RFN:DVKHUV
Template
,QVWDOODWLRQ6HUYLFH
Stop Screw
4 Machine Screws
Support Frames
with 8 Screws
and 8 Washers
4 Hex-Head
Lag Screws
'HFRUDWLYH'XFW&RYHUV
11
STEP 4 MOUNT TEMPLATE
$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQGWDSH
in place.
– Be sure the template is oriented correctly, with the front
of the hood.
8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHVZLOOSUR
vide parallel alignment with the countertop below.
&HQWHUSXQFKDOOKROHORFDWLRQV
'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHDELW
DQGGULOODSSUR[LPDWHO\GHHS
&XWWKHGXFWRSHQLQJDQGDSSUR[LPDWHO\ZLUH
access hole.
Installation Instructions
STEP 5 INSTALL SUPPORT FRAME
Install upper support frame
6HFXUHWKHXSSHUVXSSRUWIUDPHWRWKHFHLOLQJMRLVWV
DQGFURVVIUDPLQJZLWKWKHODJVFUHZVSURYLGHG)RU
PD[LPXPULJLGLW\DQGVWUHQJWKWKHVFUHZVPXVWEH
GULYHQLQWRWKHFHQWHURIWKHMRLVWVDQGRUFURVVIUDPLQJ
&KHFNWREHVXUHWKHVXSSRUWIUDPHLVOHYHOYHUWLFDOO\
DQGKRUL]RQWDOO\
Install lower support frame
,QVHUWORZHUVXSSRUWIUDPHRUDFFHVVRU\VXSSRUWIUDPH
=;6)66RU=;6)66LQWRWKHXSSHUVXSSRUW
IUDPHDQGORRVHO\VHFXUHZLWKVFUHZVDQGZDVKHUV
RQWKHIURQWDQGRQWKHEDFNVLGHV
$GMXVWWKHORZHUVXSSRUWIUDPHXSRUGRZQWRWKH
desired height above the countertop. Tighten screws.
IMPORTANT: Again, check to be sure the support is level in
both directions. There is no way to level the hood after the
hood is secured to the frame.
30" Recommended
10"
40"
Countertop
Hood
Mounting
Flange
Lower Support
76"
Wire Access Holes
12
Installation Instructions
STEP 6 SECURE WIRING
5RXWHKRXVHZLULQJWKURXJKWKHFHLOLQJKROHDQGSXOOD
OHQJWKWRUHDFKWKHKRRGMXQFWLRQER[DSSUR[LPDWHO\
below the support.
STEP 7 SIZE AND INSTALL
DUCTWORK
7DSHWKHZLUHWRWKHOHIWVLGHRIWKHIUDPHVXSSRUWWR
prevent damage during installation and service.
0HDVXUHIURPKRXVHGXFWÀDQJHWRERWWRPRIVXSSRUW
frame (Dim. A).
²$GGDWOHDVWIRUGXFWRYHUODSDWWKHWRS
²6XEWUDFWIRUKRRGLQVHUWLRQLQWRWKHERWWRPRI
the frame to determine required duct length.
&XWWKHGXFWOHQJWKUHTXLUHG
NOTE:7KHERWWRPRIWKHGXFWPXVWEHH[WHUQDOIHPDOH
connection to the top of the hood. The bottom end should
EHÀDUHGVOLJKWO\WRIDFLOLWDWHLQVWDOODWLRQRIWKHKRRG
,QVWDOOGXFWXSWKURXJKVXSSRUWIUDPHVDQGDWWDFKWR
house ducting with sheet metal screws.
6HDOWKHFRQQHFWLRQZLWKGXFWWDSH
Ceiling
Support
Frames
Tape
House
Wiring
Left Side
View
13
Installation Instructions
STEP 8 INSTALL DECORATIVE DUCT COVERS
3UHWDSRUGULYHGHFRUDWLYHVFUHZLQWRWKHVFUHZKROHV
on the support frame. This will make screw installation
easier.
6HSDUDWHWKHWZRGHFRUDWLYHGXFWFRYHUV
6HOHFWWKHLQVLGHFRYHUWRSZKLFKKDVWZRVFUHZKROHV
in the top.
6OLGHWKHGHFRUDWLYHGXFWFRYHURYHUWKHVXSSRUWIUDPH
and push to the ceiling.
$WWDFKWRWKHKRRGVXSSRUWDWWKHWRSZLWKVXSSOLHG
decorative screws.
/RFDWHWKHWKLUGGHFRUDWLYHVFUHZLQWKHKDUGZDUH
package. Set aside.
6OLGHWKHORZHUGHFRUDWLYHGXFWRYHUWKHLQVWDOOHGXSSHU
duct and push to the top.
,QVWDOOWKHGHFRUDWLYHVWRSVFUHZLQWKHFHQWHUKROHRIWKH
XSSHULQQHUGXFWFRYHU7KHGHFRUDWLYHVFUHZZLOODFWDV
a stop screw and prevent the lower decorative duct cover
from sliding down.
CAUTION: The stop screw must be installed.
)DLOXUHWRGRVRFRXOGUHVXOWLQSHUVRQDOLQMXU\RUGDPDJH
to the duct cover.
PRUDENCE : /DYLVVXSpULHXUHGRLWrWUH
HQSODFHD¿QG·pYLWHUOHVEOHVVXUHVRXG·HQGRPPDJHUOH
capot antipoussière.
STEP 9 INSTALL HOOD
NOTE: AT LEAST THREE PEOPLE ARE REQUIRED TO
COMPLETE THIS INSTALLATION!
/LIWWKHKRRGXSWRWKHVXSSRUWIUDPH&DUHIXOO\DOLJQWKH
hood mounting holes to the support frame holes and, at
the same time, the hood duct connector into the duct.
,QVWDOOVFUHZVWKURXJKWKHKRRGDQGKRRGVXSSRUW
&KHFNKRRGOHYHOLQERWKGLUHFWLRQV
&KHFNWREHVXUHWKDWWKHGXFWLVSRVLWLRQHGRYHUWKH
hood connector.
6HDOWKHGXFWFRQQHFWLRQZLWKGXFWWDSH
NOTE:'RQRWGULYHVFUHZVWKURXJKWKLVGXFWFRQQHFWLRQ
'RLQJVRZLOOSUHYHQWSURSHUGDPSHURSHUDWLRQ
Stop Screw
Apply Duct Tape
to Seal Duct
Connection
Install
4 Lock Washers
and 4 Machine Bolts
Bottom
Duct
Cover
Right
Side
Front
Front
Front
14
Installation Instructions
STEP 10 CONNECT ELECTRICAL
9HULI\WKDWSRZHULVWXUQHGRȹDWWKHVRXUFH
WARNING: ,IKRXVHZLULQJLVQRWZLUH
with a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure to use
8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR
copper connectors.
AVERTISSEMENT : Si le câblage de
ODPDLVRQQ·HVWSDVGXW\SHjGHX[¿OVDYHFXQ¿OGHWHUUH
O·LQVWDOODWHXUGRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHV¿OV
de la maison sont en aluminium, il prendre soin d’utiliser
GHODSkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQ
QHFWHXUVSRXUO·DOXPLQLXPFXLYUH
,QVWDOOVWUDLQUHOLHIRQWRWKHNQRFNRXWRIWKHMXQFWLRQER[
cover.
,QVHUWKRXVHZLULQJWKURXJKVWUDLQUHOLHIDQGWLJKWHQ
&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQRU
bare ground lead.
6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFKHOHFWULFDO
connector.
3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%HVXUH
wires are not pinched.
STEP 11
SLIDE DUCT COVER DOWN
+ROGWKHGHFRUDWLYHGXFWFRYHUDQGUHPRYHWKH
GHFRUDWLYHVWRSVFUHZIURPWKHVXSSRUWIUDPH'UHVV
all wire harnesses out of the path of the duct cover
seating.
6OLGHWKHORZHUGXFWFRYHUGRZQRQWRWKHKRRG
15
Installation Instructions
STEP 12 INSTALL FILTERS, FINALIZE INSTALLATION
7LSWKH¿OWHULQWRWKHlower slots at the rear of the
RSHQLQJ/LIWWKH¿OWHUDQGSXOOWKHNQREIRUZDUGXQWLOWKH
¿OWHUUHVWVRQWKHVORWV
0DNHVXUH\RXKDYHHQJDJHGWKH&OHDQ)LOWHU5HPLQGHU
6ZLWFKZLWKWKHULJKWVLGHJUHDVH¿OWHUE\FKHFNLQJWR
see if the red light is glowing in the display. If the red
OLJKWLVJORZLQJSOHDVHDGMXVWWKH¿OWHUXQWLOWKHUHG
LQGLFDWRUOLJKWWXUQVRȺ
&OHDQWKHKRRGZLWKDQDSSURYHGVWDLQOHVVVWHHOFOHDQHU
&KHFNKRRGRSHUDWLRQ,IWKHKRRGGRHVQRWRSHUDWH
check that house wires have been connected securely
and that no wires have been damaged during
installation. Check the breaker or house fuse is turned
on.
Filter Slots
16
Note: While performing installations described in this
ERRNVDIHW\JODVVHVRUJRJJOHVVKRXOGEHZRUQ
For Monogram
®
local service in your area, call
1.800.444.1845.
Note: 3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW
General Electric. Therefore, materials, appearance and
VSHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH

*(
Printed in Italy
/