Monogram ZV1050SFSS is a 42” Island Vent Hood designed for use in vented ceiling-mounted installations. It can be installed over any GE Appliances cooktops or ranges. This powerful vent hood features a 3-speed fan control, halogen lighting, and dishwasher-safe filters, making it easy to keep your kitchen clean and free of cooking odors. With its sleek design and powerful performance, the Monogram ZV1050SFSS is the perfect addition to any kitchen.

Monogram ZV1050SFSS is a 42” Island Vent Hood designed for use in vented ceiling-mounted installations. It can be installed over any GE Appliances cooktops or ranges. This powerful vent hood features a 3-speed fan control, halogen lighting, and dishwasher-safe filters, making it easy to keep your kitchen clean and free of cooking odors. With its sleek design and powerful performance, the Monogram ZV1050SFSS is the perfect addition to any kitchen.

INSTALLATION
INSTRUCTIONS
42” Island Vent Hood
ZV1050
MONOGRAM.COM
2 31-14899 Rev. 3
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ
IMPORTANT Save these instructions
for local inspector’s use.
Ŷ
IMPORTANT Observe all governing
codes and ordinances.
ŶNote to Installer Be sure to leave these
instructions with the Consumer.
ŶNote to Consumer Keep these instructions with
your Owner’s Manual for future reference.
ŶSkill Level Installation of this appliance requires
basic mechanical and electrical skills.
ŶCompletion Time — 1 to 3 Hours.
Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKH
LQVWDOOHU3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ
is not covered under the warranty.
Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca
Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW
monogram.com/use-and-care/parts.
CAUTION
Due to the weight and size of this
vent hood and to reduce the risk of personal injury
RUGDPDJHWRWKHSURGXFWwe recommend at least
three people install this hood.
ATTENTION
À cause du poids et de la taille de
la hotte et pour réduire les risques de blessures ou de
GRPPDJHVGHO¶pTXLSHPHQWnous recommandons
que trois personnes installent cette hotte.
WARNING
To reduce the risk of fire or electrical
VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO
VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.
AVERTISSEMENT
3RXUUpGXLUHOHULVTXH
G¶LQFHQGLHRXGHFKRFpOHFWULTXHLOQHIDXWSDVXWLOLVHU
cette hotte avec un régulateur de vitesse électronique
H[WHUQH7RXWHPRGLILFDWLRQGHFHW\SHGXEUDQFKHPHQW
d’usine peute endommager l’appareil ou créer un
risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING
725('8&(7+(5,6.2)),5(
(/(&75,&$/6+2&.25,1-85<723(56216
2%6(59(7+()2//2:,1*
$8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH
PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW
the manufacturer.
%%HIRUHVHUYLFLQJRUFOHDQLQJXQLWVZLWFKSRZHURIIDW
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
VHUYLFHSDQHOFDQQRWEHORFNHGIDVWHQDWDJRU
prominent warning label to the panel.
AVERTISSEMENT
32855e'8,5(/(5,648(
'¶,1&(1',('(&+2&e/(&75,48(28'(%/(6685(6
,/)$872%6(59(5/(65(*/(668,9$17(6
$
Utilisez cet appareil uniquement de la maniéré prévue par
OHIDEULFDQW(QFDVGHTXHVWLRQFRQVXOWH]OHIDEULFDQW
B. $YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSH]
l’alimentation électrique au disjoncteur et verrouillez le
panneau du disjoncteur pour éviter la mise sous tension
accidentelle. S’il n’est pas possible de verrouiller le
SDQQHDXGXGLVFRQFWHXUDWWDFKH]XQSODFDUGRXXQH
étiquette très visible au panneau.
Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW
KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
wiring must be done by qualified person(s) in
accordance with all applicable codes and standards
including fire-rated construction.
ŶSufficient air is needed for proper combustion and
H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZWKH
heating equipment manufacturer’s guideline and safety
VWDQGDUGVVXFKDVWKRVHSXEOLVKHGE\WKH1DWLRQDO)LUH
3URWHFWLRQ$VVRFLDWLRQ1)3$WKH$PHULFDQ6RFLHW\IRU
+HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ(QJLQHHUV
$6+5$(DQGWKHORFDOFRGHDXWKRULWLHV:KHQ
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQHOHFWULFDOFRQQHFWLRQV
and grounding must comply with applicable codes.
,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH
LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH
$16,1)3$RUODWHVWHGLWLRQ
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer un
FRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXHG¶LQFHQGLH
et pouvoir évacuer l’air correctement. Il ne faut pas
évacuer l’air correctement. Il ne faut pas évacuer l’air
GDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXUXQSODIRQGRXXQ
JUHQLHUXQHVSDFHVDQLWDLUHRXXQJDUDJH
31-14899 Rev. 3 3
Design Information
CONTENTS
Design Information
3URGXFW'LPHQVLRQV ...................................................... 3
'XFW&RYHU$FFHVVRULHV ............................................
Determine Installation Height .......................................
$GYDQFH3ODQQLQJ
Tools and Materials Required ....................................... 5
3RZHU6XSSO\ ................................................................ 5
'XFW)LWWLQJV .................................................................. 6
Installation Instructions
6WHS&RQVWUXFW&HLOLQJ6XSSRUW ............................. ± 
6WHS5HPRYH3DFNDJLQJ ......................................... 
6WHS&KHFN,QVWDOODWLRQ+DUGZDUH ........................... 
6WHS0RXQW7HPSODWH .............................................. 11
6WHS,QVWDOO6XSSRUW)UDPH ..................................... 11
6WHS6HFXUH:LULQJ ................................................. 12
6WHS6L]HDQG,QVWDOO'XFWZRUN ............................... 12
6WHS,QVWDOO'HFRUDWLYH'XFW&RYHUV ....................... 13
6WHS,QVWDOO+RRG ..................................................... 13
6WHS&RQQHFW(OHFWULFDO ......................................... 
6WHS6OLGH'XFW&RYHU'RZQ ................................ 
6WHS,QVWDOO)LOWHUV)LQDOL]H,QVWDOODWLRQ ................. 15
PRODUCT DIMENSIONS
This vent hood is designed to be used in vented ceiling-
mounted installations. It can be installed over any
0RQRJUDPFRRNWRSRUUDQJHLQFOXGLQJ3URIHVVLRQDO
models.
DUCT COVER ACCESSORIES
$'XFW&RYHU$FFHVVRU\PD\EHUHTXLUHGIRU\RXUKRRG
LQVWDOODWLRQKHLJKW2UGHUDFFHVVRU\GXFWFRYHUVIRUIW
DQGIWFHLOLQJV
ZX1059SFSS )RUIWFHLOLQJKHLJKW
This kit includes a decorative duct cover and support
IUDPHWRUHDFKDIWFHLOLQJKHLJKW
ZX10510SFSS )RUIWFHLOLQJKHLJKW
This kit includes a decorative duct cover and support
IUDPHWRUHDFKDIWFHLOLQJKHLJKW
´WRDQIWFHLOLQJXVLQJVXSSOLHGGXFWFRYHU
´IRUIWFHLOLQJXVLQJ=;6)66$FFHVVRU\
´IRUIWFHLOLQJXVLQJ=;6)66$FFHVVRU\
This vent hood is supplied with a decorative duct cover
WRUHDFKIWFHLOLQJKHLJKWRUEHWZHHQ¶´DQG¶´
10"
*Height
to Ceiling
42"
31-1/2"
31-14899 Rev. 3
DUCT COVER ACCESSORIES
Order the accessory at the same time as the vent
hood and have on-site before installation begins.
Use this chart to accurately determine the need for a
'XFW&RYHU$FFHVVRU\
Design Information
DETERMINE INSTALLATION HEIGHT
The distance between the cooking surface and the
ERWWRPRIWKHKRRGPXVWEHDWOHDVW´7KH´
UHFRPPHQGHGLQVWDOODWLRQKHLJKWDERYHWKHVWDQGDUG
´FRXQWHUWRSZLOOHQVXUHGXFWFRYHUILWWRWKHFHLOLQJ
)RUIWDQGIWFHLOLQJKHLJKWVWKHKRRGPD\EH
ORZHUHGWR´RYHUWKHFRRNLQJVXUIDFH
Ŷ:KHQLQVWDOOLQJWKH,VODQG+RRGDERYHD0RQRJUDP
3URIHVVLRQDO5DQJHRU5DQJHWRSLQVWDOODWLRQ
FOHDUDQFHPXVWEHDWOHDVW´
IMPORTANT: Clearances may vary due to type of
cooking product and local codes. Check with local
inspectors to be sure standard is applicable.
DUCT COVER DIMENSIONS
Installation Heights
Actual
Ceiling
Height
Possible
VENTED
Installation
Height
Duct Cover
7'11" 29" Supplied
8'0" 30" Supplied
8'1" 30" Supplied
8'2" 25-1/2" to 30" ZX1059SFSS
8'3" 25-1/2" to 30" ZX1059SFSS
8'4" 25-1/2" to 30" ZX1059SFSS
8'5" 25-1/2" to 30" ZX1059SFSS
8'6" 25-1/2" to 30" ZX1059SFSS
8'7" 25-1/2" to 30" ZX1059SFSS
8'8" 25-1/2" to 30" ZX1059SFSS
8'9" 25-1/2" to 30" ZX1059SFSS
8'10" 25-1/2" to 30" ZX1059SFSS
8'11" 25-1/2" to 30" ZX1059SFSS
9'0" 25-1/2" to 30" ZX1059SFSS
9'1" 25-1/2" to 30" ZX10510SFSS
9'2" 25-1/2" to 30" ZX10510SFSS
9'3" 25-1/2" to 30" ZX10510SFSS
9'4" 25-1/2" to 30" ZX10510SFSS
9'5" 25-1/2" to 30" ZX10510SFSS
9'6" 25-1/2" to 30" ZX10510SFSS
9'7" 25-1/2" to 30" ZX10510SFSS
9'8" 25-1/2" to 30" ZX10510SFSS
9'9" 25-1/2" to 30" ZX10510SFSS
9'10" 25-1/2" to 30" ZX10510SFSS
9'11" 25-1/2" to 30" ZX10510SFSS
10'0" 25-1/2" to 30" ZX10510SFSS
*30"
Recommended
36" Min.
IWWRIWFHLOLQJVPD\EH´WR´FOHDUDQFH
ZV1050 Duct Cover
Dimensions
Model A B
=9 11-1/2" 12"
=;  
=; 25" 26"
31-14899 Rev. 3 5
TOOLS AND MATERIALS REQUIRED
(not supplied)
Tape measure
Knife
Spirit level
:LUHFXWWHU
:LUHVWULSSHU
:LUHQXWV
(OHFWULFGULOODQG´ELW
3KLOOLSVVFUHZGULYHU
)ODWEODGHVFUHZGULYHU
Hammer
3OLHUV
Safety glasses
Tape to mount template
*ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV
9+]RU$PSZLUHZLWKJURXQG
properly grounded branch circuit
Strain relief for junction cover
3OXPEERE
Center punch
Advance Planning
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
AVERTISSEMENT
3285'(65$,6216
'(6e&85,7e&(7$33$5(,/'2,7Ç75(
&255(&7(0(170,6¬/$7(55(
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWK
WKLVDSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRU
prevailing local codes and ordinances.
Electrical supply
7KLVYHQWKRRGPXVWEHVXSSOLHGZLWK9+]
FRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHGEUDQFK
FLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time-delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJLQWKHFHLOLQJDVFORVHWRWKH
LQVWDOODWLRQORFDWLRQDVSRVVLEOH$OORZDQDGGLWLRQDO
3-feet length from ceiling joists to reach the junction
ER[RQWKHKRRG
Ŷ&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil
de mise à la terre peut causer un choc électrique. En
FDVGHGRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQ
technicien pour déterminer si l’appareil est à la terre.
6 31-14899 Rev. 3
Advance Planning
DUCT FITTINGS
This Hood Must Use an 8” Round
Duct. It Can Transition to a
3-1/4” x 12” Duct.
8VHWKLVFKDUWWRFRPSXWHPD[LPXPSHUPLVVLEOHOHQJWKV
for duct runs to outdoors.
NOTE:'RQRWH[FHHGPD[LPXPSHUPLVVLEOHHTXLYDOHQW
lengths!
Maximum duct length: 100 foot for range hoods.
Flexible ducting
,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOOWKHHTXLYDOHQWIHHW
YDOXHVLQWKHWDEOHVKRXOGEHGRXEOHG7KHIOH[LEOHPHWDO
GXFWVKRXOGEHVWUDLJKWDQGVPRRWKDQGH[WHQGHGDV
much as possible.
'R127XVHIOH[LEOHSODVWLFGXFWLQJ
NOTE:$Q\KRPHYHQWLODWLRQV\VWHPVXFKDVD
YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUIORZRI
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\ILUHSODFHVJDV
IXUQDFHVJDVZDWHUKHDWHUVDQGRWKHUQDWXUDOO\YHQWHG
systems. To minimize the chance of interruption of such
QDWXUDOO\YHQWHGV\VWHPVIROORZWKHKHDWLQJHTXLSPHQW
manufacturer’s guidelines and safety standards such
DVWKRVHSXEOLVKHGE\1)3$DQG$6+5$(:KHQ
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
Duct Piece Dimensions
Equivalent
Length*
Quantity
Used
Total
Equivalent
Length
5RXQG
straight
1 ft. (per foot
length)
´[´
straight
1 ft. (per foot
length)
HOERZ IW
HOERZ IW
´[´
HOERZ
IW
´[´
HOERZ
26 ft.
´[´
IODW
elbow
IW
´URXQGWR
´[´
transition
2 ft.
´[´
WR´URXQG
transition
5 ft.
´URXQGWR
´[´
WUDQVLWLRQ
elbow
6 ft.
´[´
WR´URXQG
WUDQVLWLRQ
elbow
13 ft.
Round wall
cap with
damper
32 ft.
´[´
wall cap with
damper
IW
Round roof
cap
IW
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJ
equivalent. Equivalent length of duct pieces
DUHEDVHGRQDFWXDOWHVWVFRQGXFWHGE\*(
$SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFW
requirements for good venting performance
with any ventilation hood.
Total Duct Run
31-14899 Rev. 3
Installation Preparation
1
CONSTRUCT CEILING SUPPORT
Plan the location
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ Use a plumb bob to check location to be sure
countertop/cooktop location below the hood will align
H[DFWO\
Ŷ7KHKRRGVKRXOGSURMHFWIRUZDUG´EH\RQGWKH
front edge of the cooking appliance. See illustration.
Ŷ2EVHUYHWKHUHFRPPHQGHGVSDFH´EHWZHHQWKH
cooking surface and bottom of hood.
Ceiling support structure
Ŷ$WWKHKRRGORFDWLRQLQVWDOO
[FURVVIUDPLQJEHWZHHQ
ceiling joists as shown.
[VDUHUHTXLUHGWRVXSSRUW
the weight of the hood.)
Ŷ$UUDQJHFURVVIUDPLQJLQWKH
FHLOLQJWRVXLWWKHH[LVWLQJ
structure.
Ŷ<RXUFHLOLQJMRLVWVZLOOEHOLNH
RQHRIWKHIROORZLQJH[DPSOHV
Ceiling
Hood
Ducting
Centerline
Side View
Approx. 1-1/2"
Beyond Cooking
Surface
Cooktop
Countertop
31-1/2"
Hood
Front
15-3/4"
,QVWDOO&URVV)UDPLQJ
6\PPHWULFDOO\$ERXW
Duct/Cooktop Centerline

-RLVW
Spacing
[&URVV
)UDPLQJ
8" Duct
$OLJQ'XFWWR
Center of Cooktop
Cooktop Outline
7RS9LHZ²&HLOLQJ-RLVWV3DUDOOHOWR)URQWRI+RRG
Front
of Hood
EXAMPLE A
8 31-14899 Rev. 3
Installation Preparation
1
CONSTRUCT CEILING SUPPORT (cont.)
EXAMPLE B
$OLJQ'XFWWR
Center of Cooktop
Cooktop
Outline
7RS9LHZ²&HLOLQJ-RLVWV5XQ3HUSHQGLFXODUWR)URQWRI+RRG
Front
of Hood
,QVWDOO&URVV)UDPLQJ
6\PPHWULFDOO\$ERXW
Duct/Cooktop Centerline
-RLVW
Spacing
[&URVV
)UDPLQJ

8" Duct
EXAMPLE C

[&URVV
)UDPLQJ
,QVWDOO
&URVV)UDPLQJ
6\PPHWULFDOO\$ERXW
Duct/Cooktop Centerline
8" Duct
-RLVW
Spacing
$OLJQ'XFWWR
Center of Cooktop Cooktop
Outline
7RS9LHZ²&HLOLQJ-RLVWVDW$QJOHZLWK)URQWRI+RRG
Front
of Hood
31-14899 Rev. 3
Installation Instructions
1
CONSTRUCT CEILING SUPPORT (cont.)
Ŷ$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVWLQJ
VWUXFWXUH6HHH[DPSOHV
±6HFXUHHDFK[EORFNZLWKDWOHDVWIRXU
ZRRGVFUHZV´ORQJQRWVXSSOLHG8VHZRRG
screws total for the two supports.
Ŷ7KHFURVVIUDPLQJPXVWEHDFFXUDWHO\DOLJQHGWR
ensure correct positioning of the hood.
Ŷ7KHFURVVIUDPLQJPXVWEHOHYHOLQDOOGLUHFWLRQV
Check with a spirit level and adjust if necessary.
IMPORTANT: The ceiling structure must be capable
of supporting the weight of the hood (approximately
300 pounds) and any inadvertent user contact loads.
The hood support frame will be supported by the 2 x
4 min. cross-framing.
Ductwork
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRW
H[FHHGIHHWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configuration.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKHPD[LPXP
permissible length for duct runs to the outdoors.
Ŷ7KLVYHQWKRRGPXVWXVH´URXQGGXFW7KH´URXQG
GXFWFDQWUDQVLWLRQWR´[´
Ŷ,QVWDOOWKHKRXVHGXFWZRUNWRUXQKRUL]RQWDOO\EHWZHHQ
ceiling joists or straight up through the roof.
Finish the Ceiling
Ŷ)LQLVKWKHFHLOLQJVXUIDFH%HVXUHWRPDUNORFDWLRQRI
the ceiling joists and cross-framing. Check to be sure
WKHFHLOLQJLVOHYHOXVHVKLPVLIQHFHVVDU\
*Depending on available space.
 31-14899 Rev. 3
Installation Instructions
2
REMOVE THE PACKAGING
The vent hood is packed separately from the decorative
GXFWFRYHURUDFFHVVRU\FRYHUV=;6)66RU
=;6)66
Ŷ5HPRYHWKHIUDPHFRYHUSDUWVER[DQGSDFNDJLQJ
Ŷ5HPRYHMXQFWLRQER[FRYHU
Ŷ,QVWDOOVWUDLQUHOLHIRQWRMXQFWLRQER[FRYHU
3
CHECK INSTALLATION HARDWARE AND ACCESSORIES
Locate the hardware accessory pack shipped with the hood and check contents.
11-1/4”
TO CENTER LINE
OF HOLES
7-1/4” TO
CENTER LINE
OF HOLES
WIRE
HOLE
ACCESS
WIRE
HOLE
ACCESS
Mounting Screw Holes
2 Phillips-Head
Decorative Screws
4 Filters
4 Lock Washers
Template
Installation/
Service Stop
Screw
4 Machine Screws
Support Frames
with 8 Screws
and 8 Washers
4 Hex-Head
Lag Screws
Decorative Duct Covers
31-14899 Rev. 3 11
4
MOUNT TEMPLATE
Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG
tape in place.
±%HVXUHWKHWHPSODWHLVRULHQWHGFRUUHFWO\ZLWKWKH
front of the hood.
Ŷ Use a plumb bob to be sure the mounting holes will
provide parallel alignment with the countertop below.
Ŷ Center-punch all hole locations.
Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´
ELWDQGGULOODSSUR[LPDWHO\´GHHS
Ŷ&XWWKH´GXFWRSHQLQJDQGDSSUR[LPDWHO\´ZLUH
access hole.
5
INSTALL SUPPORT FRAME
Install upper support frame
Ŷ6HFXUHWKHXSSHUVXSSRUWIUDPHWRWKHFHLOLQJMRLVWV
DQGFURVVIUDPLQJZLWKWKHODJVFUHZVSURYLGHG
)RUPD[LPXPULJLGLW\DQGVWUHQJWKWKHVFUHZVPXVW
be driven into the center of the joists and/or cross-
framing.
Check to be sure the support frame is level,
vertically and horizontally.
Install lower support frame
Ŷ,QVHUWORZHUVXSSRUWIUDPHRUDFFHVVRU\VXSSRUW
IUDPH=;6)66RU=;6)66LQWRWKHXSSHU
support frame and loosely secure with 8 screws and
ZDVKHUVRQWKHIURQWDQGRQWKHEDFNVLGHV
Ŷ$GMXVWWKHORZHUVXSSRUWIUDPHXSRUGRZQWRWKH
desired height above the countertop. Tighten screws.
,03257$17$JDLQFKHFNWREHVXUHWKHVXSSRUWLV
level in both directions. There is no way to level the
hood after the hood is secured to the frame.
Installation Instructions
Wire Access Holes
30" Recommended
10"
40"
Countertop
Hood
Mounting
Flange
Lower Support
76"
12 31-14899 Rev. 3
Installation Instructions
6
SECURE WIRING
Ŷ5RXWHKRXVHZLULQJWKURXJKWKHFHLOLQJKROHDQG
SXOODOHQJWKWRUHDFKWKHKRRGMXQFWLRQER[
DSSUR[LPDWHO\´EHORZWKHVXSSRUW
Ŷ7DSHWKHZLUHWRWKHOHIWVLGHRIWKHIUDPHVXSSRUWWR
prevent damage during installation and service.
7
SIZE AND INSTALL DUCTWORK
Ŷ0HDVXUHIURPKRXVHGXFWIODQJHWRERWWRPRI
VXSSRUWIUDPH'LP$
±$GGDWOHDVW´IRUGXFWRYHUODSDWWKHWRS
±6XEWUDFW´IRUKRRGLQVHUWLRQLQWRWKHERWWRP
of the frame to determine required duct length.
Ŷ&XWWKH´GXFWOHQJWKUHTXLUHG
NOTE:7KHERWWRPRIWKHGXFWPXVWEHH[WHUQDO
(female) connection to the top of the hood. The
ERWWRPHQGVKRXOGEHIODUHGVOLJKWO\WRIDFLOLWDWH
installation of the hood.
Ŷ,QVWDOOGXFWXSWKURXJKVXSSRUWIUDPHVDQGDWWDFKWR
house ducting with sheet metal screws.
Ŷ6HDOWKHFRQQHFWLRQZLWKGXFWWDSH
Ceiling
Support
Frames
Tape
House
Wiring
Left Side
View
31-14899 Rev. 3 13
Installation Instructions
8
INSTALL DECORATIVE DUCT COVERS
Ŷ3UHWDSRUGULYHGHFRUDWLYHVFUHZLQWRWKHVFUHZKROHV
on the support frame. This will make screw installation
easier.
Ŷ6HSDUDWHWKHWZRGHFRUDWLYHGXFWFRYHUV
Ŷ6HOHFWWKHLQVLGHFRYHUWRSZKLFKKDVWZRVFUHZ
holes in the top.
Ŷ6OLGHWKHGHFRUDWLYHGXFWFRYHURYHUWKHVXSSRUWIUDPH
and push to the ceiling.
Ŷ$WWDFKWRWKHKRRGVXSSRUWDWWKHWRSZLWKVXSSOLHG
decorative screws.
Ŷ/RFDWHWKHWKLUGGHFRUDWLYHVFUHZLQWKHKDUGZDUH
package. Set aside.
Ŷ6OLGHWKHORZHUGHFRUDWLYHGXFWRYHUWKHLQVWDOOHG
upper duct and push to the top.
Ŷ,QVWDOOWKHGHFRUDWLYHVWRSVFUHZLQWKHFHQWHUKROHRI
the upper (inner) duct cover. The decorative screw will
act as a stop screw and prevent the lower decorative
duct cover from sliding down.
CAUTION
The stop screw must be installed.
)DLOXUHWRGRVRFRXOGUHVXOWLQSHUVRQDOLQMXU\RU
damage to the duct cover.
ATTENTION
/DYLVVXSpULHXUHGRLWrWUHHQSODFH
afin d’éviter les blessures ou d’endommager le capot
antipoussière.
9
INSTALL HOOD
NOTE: AT LEAST THREE PEOPLE ARE REQUIRED
TO COMPLETE THIS INSTALLATION!
Ŷ/LIWWKHKRRGXSWRWKHVXSSRUWIUDPH&DUHIXOO\DOLJQ
the hood mounting holes to the support frame holes
DQGDWWKHVDPHWLPHWKHKRRGGXFWFRQQHFWRULQWR
the duct.
Ŷ,QVWDOOVFUHZVWKURXJKWKHKRRGDQGKRRGVXSSRUW
Ŷ&KHFNKRRGOHYHOLQERWKGLUHFWLRQV
Ŷ&KHFNWREHVXUHWKDWWKHGXFWLVSRVLWLRQHGRYHUWKH
hood connector.
Ŷ6HDOWKHGXFWFRQQHFWLRQZLWKGXFWWDSH
NOTE: Do not drive screws through this duct connection.
Doing so will prevent proper damper operation.
Right
Side
Front
Front
Front
Stop Screw
Apply Duct Tape
to Seal Duct
Connection
Install
4 Lock Washers
and 4 Machine Bolts
Bottom
Duct
Cover
 31-14899 Rev. 3
Installation Instructions
10
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH
LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH
WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG
aluminum-to-copper connectors.
AVERTISSEMENT
Si le câblage de la maison
Q¶HVWSDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUH
O¶LQVWDOODWHXUGRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHV
ILOVGHODPDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQ
G¶XWLOLVHUGHODSkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HW
des connecteurs pour l’aluminium-cuivre.
Ŷ,QVWDOOVWUDLQUHOLHIRQWRWKHNQRFNRXWRIWKHMXQFWLRQ
ER[FRYHU
Ŷ,QVHUWKRXVHZLULQJWKURXJKVWUDLQUHOLHIDQGWLJKWHQ
Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%H
sure wires are not pinched.
11
SLIDE DUCT COVER DOWN
Ŷ+ROGWKHGHFRUDWLYHGXFWFRYHUDQGUHPRYHWKH
decorative stop screw from the support frame.
Dress all wire harnesses out of the path of the duct
cover seating.
Ŷ6OLGHWKHORZHUGXFWFRYHUGRZQRQWRWKHKRRG
31-14899 Rev. 3 15
Installation Instructions
12
INSTALL FILTERS, FINALIZE INSTALLATION
Ŷ7LSWKHILOWHULQWRWKHORZHUVORWVDWWKHUHDURIWKH
opening. Lift the filter and pull the knob forward until
the filter rests on the slots.
Ŷ0DNHVXUH\RXKDYHHQJDJHGWKH³&OHDQ)LOWHU
5HPLQGHU6ZLWFK´ZLWKWKHULJKWVLGHJUHDVHILOWHU
by checking to see if the red light is glowing in the
GLVSOD\,IWKHUHGOLJKWLVJORZLQJSOHDVHDGMXVWWKH
filter until the red indicator light turns off.
Ŷ&OHDQWKHKRRGZLWKDQDSSURYHGVWDLQOHVVVWHHO
cleaner.
Ŷ
&KHFNKRRGRSHUDWLRQ,IWKHKRRGGRHVQRWRSHUDWH
check that house wires have been connected securely
and that no wires have been damaged during installation.
Check the breaker or house fuse is turned on.
Filter Slots
NOTE::KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN
safety glasses or goggles should be worn.
)RU0RQRJUDP
®
ORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
NOTE:3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW
0RQRJUDP$SSOLDQFHV7KHUHIRUHPDWHULDOVDSSHDUDQFH
and specifications are subject to change without notice.
31-14899 Rev. 3
10-19 GEA
Printed in Italy
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

GE ZV1050SFSS Installation guide

Type
Installation guide

Monogram ZV1050SFSS is a 42” Island Vent Hood designed for use in vented ceiling-mounted installations. It can be installed over any GE Appliances cooktops or ranges. This powerful vent hood features a 3-speed fan control, halogen lighting, and dishwasher-safe filters, making it easy to keep your kitchen clean and free of cooking odors. With its sleek design and powerful performance, the Monogram ZV1050SFSS is the perfect addition to any kitchen.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI