GE ZV800SJSS Installation guide

Type
Installation guide
INSTALLATION
INSTRUCTIONS
30” Chimney Vent Hood
ZV800
MONOGRAM.COM
2 49-80267 Rev. 4
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ
IMPORTANT Save these instructions
for local inspector’s use.
Ŷ
IMPORTANT Observe all governing
codes and ordinances.
ŶNote to Installer Be sure to leave these
instructions with the Consumer.
ŶNote to Consumer Keep these instructions with
your Owner’s Manual for future reference.
ŶSkill Level Installation of this appliance requires
basic mechanical and electrical skills.
ŶCompletion Time — 1 to 3 Hours.
Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKH
LQVWDOOHU3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ
is not covered under the warranty.
Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca
Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW
monogram.com/use-and-care/parts.
CAUTION
Due to the weight and size of these
vent hoods and to reduce the risk of personal injury
RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
ATTENTION
À cause du poids et de la taille de
ces hottes et pour reduire le risque de blessures et de
GRPPDJHV IL FAUT DEUX PERSONNES POUR FAIRE
L’INSTALLATION CORRECTEMENT.
WARNING
To reduce the risk of fire or electrical
VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO
VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.
AVERTISSEMENT
3RXUUpGXLUHOHULVTXHG¶LQFHQGLH
RXGHFKRFpOHFWULTXHLOQHIDXWSDVXWLOLVHUFHWWHKRWWH
DYHFXQUpJXODWHXUGHYLWHVVHpOHFWURQLTXHH[WHUQH7RXWH
modification de ce type du branchement d’usine peute
HQGRPPDJHUO¶DSSDUHLORXFUpHUXQULVTXHGHFKRFpOHFWULTXH
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING
725('8&(7+(5,6.2)),5(
(/(&75,&$/6+2&.25,1-85<723(56216
2%6(59(7+()2//2:,1*
$8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH
PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW
the manufacturer.
%%HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH
power off at the service panel and lock the service
disconnecting means to prevent the power from
EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH
GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\
IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ
to the service panel.
AVERTISSEMENT
32855e'8,5(/(5,648(
'¶,1&(1',('(&+2&e/(&75,48(28'(%/(6685(6
,/)$872%6(59(5/(65(*/(668,9$17(6
$
8WLOLVH]FHWDSSDUHLOXQLTXHPHQWGHODPDQLpUpSUpYXHSDU
OHIDEULFDQW(QFDVGHTXHVWLRQFRQVXOWH]OHIDEULFDQW
% $YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSH]
O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOH]OH
SDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXVWHQVLRQ
accidentelle. S’il n’est pas possible de verrouiller le
SDQQHDXGXGLVFRQFWHXUDWWDFKH]XQSODFDUGRXXQH
pWLTXHWWHWUqVYLVLEOHDXSDQQHDX
Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWR
H[KDXVWKD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
wiring must be done by qualified person(s). In
accordance with all applicable codes and standards
including fire-rated construction.
Ŷ6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ
the heating equipment manufacturer’s guidelines
DQGVDIHW\VWDQGDUGVVXFKDVWKRVHSXEOLVKHGE\
WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$WKH
$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG$LU
&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQGWKHORFDOFRGH
DXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS
(replacement) air system in accordance with local
building code requirements.
Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDO
connections and grounding must comply with
DSSOLFDEOHFRGHV,QWKHDEVHQFHRIORFDOFRGHVWKH
YHQWVKRXOGEHLQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO
(OHFWULFDO&RGH$16,1)3$RUODWHVWHGLWLRQ
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer un conduit
YHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXHG¶LQFHQGLHHWSRXYRLU
pYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDVpYDFXHUO¶DLUGDQV
O¶HVSDFHHQWUHOHVSDURLVG¶XQPXUXQSODIRQGRXXQJUHQLHU
un espace sanitaire ou un garage.
49-80267 Rev. 4 3
Design Information
PRODUCT DIMENSIONS AND
CLEARANCES
7KHYHQWKRRGPXVWEHLQVWDOOHG´PLQDQG´PD[
above the cooking surface. The telescopic duct cover
conceals the ductwork running from the top of the hood
to the ceiling. The duct cover is sized to reach 8 ft. to
IWFHLOLQJKHLJKWV
7KHKRRGLQVWDOODWLRQKHLJKWIURPWKHFRRNLQJVXUIDFH
WRWKHERWWRPRIWKHKRRGGHSHQGVXSRQFHLOLQJKHLJKW
INSTALLATION OPTIONS
WALL-MOUNTED INSTALLATIONS
This hood may be installed
onto a wall and vented to
WKHRXWGRRUVRULWFDQEH
installed for recirculating
RSHUDWLRQ$OOQHFHVVDU\
parts for a recirculating
operation are shipped with
WKHKRRG1RNLWVUHTXLUHG
UNDER-CABINET
INSTALLATIONS
The hood may be installed beneath a cabinet. The
FDELQHWPXVWPHDVXUHDWOHDVW´IURPWKHERWWRP
IUDPHWRWKHLQVLGHWRS6HHSDJH
Ŷ Both vented and
recirculating operation can
be accomplished in an
under-cabinet installation.
(Custom cabinet
modification is required for
recirculating operation.)
CONTENTS
Safety Information ....................................................... 2
Design Information
3URGXFW'LPHQVLRQVDQG&OHDUDQFHV ............................ 3
Installation Options ........................................................ 3
$GYDQFH3ODQQLQJ'XFWZRUN)UDPLQJ ......................... 4
3RZHU6XSSO\ ................................................................ 4
'XFW)LWWLQJV .................................................................. 5
Installation Preparation
Tools and Materials Required ....................................... 6
5HPRYHWKH3DFNDJLQJ ................................................. 6
:DOO0RXQW,QVWDOODWLRQV ................................................
,QVWDOODWLRQ%HORZD:DOO&DELQHW ..................................
Check Installation Hardware ......................................... 8
'XFWZRUN:LULQJ/RFDWLRQV ...........................................
Installation—Vented to the Outside
6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW......................
6WHS,QVWDOO0RXQWLQJ%UDFNHW ................................. 
6WHS,QVWDOO'XFW%UDFNHW ......................................... 
6WHS3UHSDUHWKH+RRG ........................................... 11
6WHS0RXQWWKH+RRG .............................................. 11
6WHS&RQQHFW'XFWZRUN .......................................... 12
6WHS&RQQHFW(OHFWULFDO ........................................... 12
6WHS,QVWDOO'XFW&RYHUV.......................................... 13
6WHS,QVWDOO)LOWHUV .................................................... 13
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 13
Wall-Mounted Installation—Recirculating
'XFWZRUN:LULQJ/RFDWLRQV ......................................... 14
6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW.................... 14
6WHS,QVWDOO0RXQWLQJ%UDFNHW ................................. 15
6WHS3UHSDUHWKH+RRG ........................................... 15
6WHS0RXQWWKH+RRG .............................................. 16
6WHS6L]HDQG&XW'XFW3LHFH................................. 16
6WHS&RQQHFW(OHFWULFDO ........................................... 
6WHS,QVWDOO'XFW&RYHUV.......................................... 
6WHS,QVWDOO)LOWHUV .................................................... 18
6WHS)LQDOL]H,QVWDOODWLRQ ......................................... 18
Wall-Mounted Installation—Recirculating
Cabinet Requirements ................................................. 
'XFWZRUN:LULQJ ......................................................... 
6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW.................... 
6WHS3UHSDUHWKH+RRG ........................................... 
6WHS&XWWKH2SHQLQJ.............................................. 21
6WHS,QVWDOO6LGH³/´%UDFNHWV .................................. 21
6WHS5HPRYH6LGH6FUHZ ....................................... 21
6WHS0RXQWWKH+RRG .............................................. 22
6WHSComplete Installation and Connect Ductwork.... 22
6WHS&RQQHFW(OHFWULFDO ........................................... 23
6WHS,QVWDOO5HDU0RXQWLQJ6FUHZV ......................... 23
6WHS,QVWDOO)LOWHUV .................................................. 23
12" at Sides,
12 7/8
"
at
-1/2"
*
Height to
Ceiling
35-7/8"
*
The Supplied Duct Co
* Height to
Ceiling
1-1/2”
´DW6LGHV
13-11/16” at Center
´
* The Supplied Duct Cover
)LWVIWWRIW&HLOLQJ+HLJKWV
NOTE: The
vent hood
FDQRS\H[WHQGV
IRUZDUG´
24” Min.
´0D[
*24” Min.
*Depending on Cabinet Height
4 49-80267 Rev. 4
Installation Preparation
ADVANCE PLANNING
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH)RU
VDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRWH[FHHG
IWHTXLYDOHQWOHQJWKIRUDQ\GXFWFRQILJXUDWLRQV
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWRQSDJHWRFRPSXWH
WKHPD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
air system in accordance with local building code
requirements. Visit Monogram.com for available
makeup air solutions.
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer un conduit
YHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXHG¶LQFHQGLHHWSRXYRLU
pYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDVpYDFXHUO¶DLU
FRUUHFWHPHQW,OQHIDXWSDVpYDFXHUO¶DLUGDQVO¶HVSDFHHQWUH
OHVSDURLVG¶XQPXUXQSODIRQGRXXQJUHQLHUXQHVSDFH
sanitaire ou un garage.
Ŷ8VHPHWDOGXFWZRUNRQO\7KHVHKRRGVPXVWXVH
´URXQGGXFW,WFDQWUDQVLWLRQWR´[´UHGXFLQJ
WKHPD[LPXPHTXLYDOHQWGXFWOHQJWKWR
IHHW
Ŷ,QVWDOODZDOOFDSZLWKGDPSHURUURRIFDSDWWKH
H[WHULRURSHQLQJ2UGHUWKHZDOORUURRIFDSDQGDQ\
transition needed in advance.
Wall Framing for Adequate Support
Ŷ7KLVYHQWKRRGLVKHDY\$GHTXDWHVWUXFWXUDOVXSSRUW
must be provided in all types of installations. The hood
PXVWEHVHFXUHGWRYHUWLFDOVWXGVLQWKHZDOORUWRD
KRUL]RQWDOVXSSRUW)RUZDOOPRXQWLQJLQVWDOODWLRQVVHH
SDJHVDQG)RUXQGHUFDELQHWLQVWDOODWLRQVVHH
SDJH
Ŷ7KHYHQWKRRGDQGZDOOFDELQHWLIXVHGVKRXOGEH
on site before final framing and wall finishing. This
will also help to accurately locate the duct work and
electrical service.
POWER SUPPLY
IMPORTANT (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
AVERTISSEMENT
3285'(65$,6216'(
6e&85,7e&(7$33$5(,/'2,7Ç75(&255(&7(0(17
0,6¬/$7(55(
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWKWKLV
DSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRUSUHYDLOLQJ
local codes and ordinances.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]
DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG
EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJWKURXJKFRQGXLWDVFORVHWRWKH
LQVWDOODWLRQORFDWLRQDVSRVVLEOHLQWKHFHLOLQJRUEDFN
wall.
Ŷ8VHDFRQGXLWFRQQHFWRUWRVHFXUHWKHFRQGXLWWRWKH
MXQFWLRQER[
Ŷ&RQQHFWWKHKRRGZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a
JURXQGHGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil
GHPLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(QFDVGH
GRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQWHFKQLFLHQSRXU
GpWHUPLQHUVLO¶DSSDUHLOHVWjODWHUUH
49-80267 Rev. 4 5
DUCT FITTINGS
This Hood Must Use an
6” Round Duct.
It Can Transition to a
3-1/4 x 12 Duct.
8VHWKLVFKDUWWRFRPSXWHPD[LPXP
permissible lengths for duct runs to
outdoors.
NOTE:'RQRWH[FHHGPD[LPXP
permissible equivalent lengths!
Maximum duct length:
100 foot for 6” round duct
75 foot for 3-1/4” x 12” duct
Flexible ducting:
,IIOH[LEOHPHWDOGXFWLQJLVXVHG
all the equivalent feet values in
the table should be doubled. The
IOH[LEOHPHWDOGXFWVKRXOGEHVWUDLJKW
DQGVPRRWKDQGH[WHQGHGDVPXFK
as possible.
'2127XVHIOH[LEOHSODVWLFGXFWLQJ
NOTE:$Q\KRPHYHQWLODWLRQ
V\VWHPVXFKDVDYHQWLODWLRQKRRG
may interrupt the proper flow of
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHG
E\ILUHSODFHVJDVIXUQDFHVJDV
water heaters and other naturally
vented systems. To minimize the
chance of interruption of such
QDWXUDOO\YHQWHGV\VWHPVIROORZWKH
heating equipment manufacturer’s
guidelines and safety standards
VXFKDVWKRVHSXEOLVKHGE\1)3$
DQG$6+5$(:KHQDSSOLFDEOH
install any makeup (replacement)
air system in accordance with
local building code requirements.
Visit Monogram.com for available
makeup air solutions.
Installation Preparation
Equivalent
Duct Piece Dimensions
Equivalent
Length*
Quantity
Used
Total
Equivalent
Length
5RXQGVWUDLJKW 1 ft.
(per foot length)
´[´´[´
straight
1 ft.
(per foot length)
6” Round
HOERZ
15 ft.
6” Round
HOERZ
8 ft.
»´[´
HOERZ
11 ft.
´[´RU
HOERZ
6 ft.
´[´
IODWHOERZ
24 ft.
6” round to
´[´WUDQVLWLRQRU
´[´WUDQVLWLRQ
1 ft.
´[´WR´
round transition
8 ft.
´URXQGWR´[´RU
WUDQVLWLRQHOERZ
16 ft.
´[´WR´
URXQGWUDQVLWLRQHOERZ
IW
6” Round wall cap
with damper
IW
´[´ZDOOFDS
with damper
IW
6” Round roof cap 26 ft
6” Round roof vent 26 ft
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJHTXLYDOHQW(TXLYDOHQW
length of duct pieces are based on actual tests conducted by
*($SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFWUHTXLUHPHQWVIRU
good venting performance with any ventilation hood.
Total Duct Run
6 49-80267 Rev. 4
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Ŷ7DSHPHDVXUH
Ŷ.QLIH
Ŷ6SLULWOHYHO
Ŷ:LUHFXWWHUVWULSSHU
Ŷ:LUHQXWV
Ŷ(OHFWULFGULOOZLWKDQGELWV
Ŷ3KLOOLSVDQGIODWEODGHVFUHZGULYHUV
Ŷ+DPPHU
Ŷ3OLHUV
Ŷ6DIHW\JODVVHV
Ŷ'XFWWDSH
Ŷ7DSHWRPRXQWWHPSODWH
Ŷ*ORYHVWRSURWHFWDJDLQVWVKDUS
edges
Ŷ9+]RU$PSZLUH
ZLWKJURXQG3URSHUO\JURXQGHG
branch circuit
Ŷ6WUDLQUHOLHIIRUMXQFWLRQFRYHU
ŶURXQGPHWDOGXFWOHQJWKWRVXLW
installation
Ŷ6DZRUMLJVDZ
Ŷ&RQGXLWIRUKRXVHZLULQJ
and conduit connector
REMOVE THE PACKAGING
Ŷ5HPRYHWKHGXFWFRYHUSDUWVER[DQGRWKHU
packaging.
Ŷ/LIWWKHKRRGRXWRIWKHER[
Ŷ5HPRYHDQGSURSHUO\GLVFDUGWKHSODVWLFZUDSSLQJ
Ŷ5HPRYHMXQFWLRQER[FRYHU
Measuring tape
Electric drill with
1/8” and 3/8” Bits
´ORQJ3KLOOLSV
head screwdriver
Safety glasses
*ORYHV
Spirit level
Knife
:LUHFXWWHUVWULSSHU
)ODWEODGHVFUHZGULYHU
Hammer
3OLHUV
Duct tape
Masking tape
:LUHQXWV
Strain relief for
MXQFWLRQER[
Saw or jig saw
Conduit
2-piece duct
cover
49-80267 Rev. 4
Installation Preparation
WALL MOUNT INSTALLATIONS
These hoods may be installed onto a wall or below a
wall cabinet.
Ŷ7HOHVFRSLFGXFWFRYHUVDUHSURYLGHGWRFRQFHDOWKH
GXFWZRUNUXQQLQJWRWKHFHLOLQJ
Ŷ7KLVKRRGFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ
RSHUDWLRQ1RNLWVUHTXLUHG
7KHYHQWKRRGPXVWEHLQVWDOOHGPLQDQG
PD[DERYHWKHFRRNLQJVXUIDFH7KHKRRGLQVWDOODWLRQ
KHLJKWIURPWKHFRRNLQJVXUIDFHWRWKHERWWRPRIWKH
KRRGGHSHQGVXSRQFHLOLQJKHLJKW
INSTALLATION BELOW A CABINET
7KHFDELQHWPXVWPHDVXUHDWOHDVW´IURPWKH
bottom frame to the inside top. The hood housing will
occupy the interior cabinet space.
Wall Mount ZV830
Installation Heights
Actual Ceiling
Height
*Possible VENTED
Installation Height
*Possible
RECIRCULATING
Installation Height
¶´ ´WR´ 
¶´ 24” to 28” 24” to 25”
8’-1” ´WR´ 24” to 26”
8’-2” ´WR´ ´WR´
8’-3” ´WR´ 24” to 28”
8’-4” ´WR´ ´WR´
8’-5” ´WR´ ´WR´
8’-6” ´WR´ ´WR´
¶´ ´WR´ ´WR´
8’-8” ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
8’-11” ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
 WR WR
 WR WR
 WR WR
 WR WR
 WR WR
  WR
* Based on 36” countertop height.
36” Min.
24” Min.
´0D[
24” Min.
´0LQ
INSTALLATION BELOW A WALL
CABINET
2UGHUDFDELQHWWKDWLVDWOHDVW´KLJKIURPWKH
bottom frame to the inside top. The cabinet must be
at least 12” deep.
Ŷ7KHKRRGLQVWDOODWLRQKHLJKWLVGHWHUPLQHGE\WKH
ceiling height.
Ŷ7KHKRRGLQVWDOODWLRQKHLJKWPXVWEH´0LQDERYH
the cooking surface.
8 49-80267 Rev. 4
Installation Preparation
CHECK INSTALLATION HARDWARE
/RFDWHWKHKDUGZDUHDFFHVVRU\ER[SDFNHGZLWKWKHKRRGDQGFKHFNFRQWHQWV
29-7/8"
11-1/2"
12"
27-3/4"
4 wood
screws
Mounting bracket
2 stainless steel filters
3KLOOLSVKHDG
screws to secure
HOHFWULFDOER[WR
top of motor
compartment
1 charcoal filter for
recirculating installations
2-piece decorative duct
cover (dimension shown
for reference only)
$LUGHIOHFWRUIRU
recirculating
installations only
Duct bracket
³/´%UDFNHWVZLWKKDUGZDUH
package for cabinet-mounted
installations.
&RQWDLQV3KLOOLSVKHDGVFUHZV
to secure the brackets to the
FDELQHWUHTXLUHGH[WUD
Cabinet installation template
REAR WALL TEMPLATE
C
L
49-80271 07-04 JR
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
ALIGN BOTTOM EDGE WITH
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
5-1/16"
9-5/8"
8-1/8"
2-1/16"
13-3/4"
12-3/4"
043021
28
:DOOPRXQWWHPSODWH
4 wall
fasteners
3KLOOLSVKHDGGHFRUDWLYH
screws to secure duct cover
to ceiling bracket
49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
0HDVXUHIURPWKHIORRUWRWKHWRSRIWKH
FRRNLQJVXUIDFH$GGKRRGLQVWDOODWLRQKHLJKW
GHWHUPLQHGRQSDJH0DUNWKDWORFDWLRQ
-
Use a level to draw a straight pencil line on the wall.
-
Tape the template in position along the penciled line.
&+(&.72%(685(7+(7(03/$7(,6/(9(/
Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
Ŷ0HDVXUH´IURPWKHEDFNZDOOWRWKHFHQWHUOLQH
of a 6-1/2” hole on the ceiling.
NOTE:,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOOWKLFNQHVV
to the 3-3/4” dimension.
Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template.
Ŷ0HDVXUHDWOHDVW´DERYHWKHWRSPRXQWLQJ
bracket holes shown on the template to the
centerline of a 6-1/2” dia. duct hole. (Hole may be
elongated for duct elbow.)
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOO´WR´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHULJKW
VLGHRIWKHFHQWHUOLQH:LULQJVKRXOGHQWHUDWOHDVW´
above the bracket on the right side.
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT: Framing must be capable of
supporting 100 lbs.
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW[EHWZHHQ
two wall studs at the mounting screw location. The
horizontal support must be flush with the room
side of the studs. Use cleats behind both sides of
the support to secure to wall studs.
Ŷ5HLQVWDOOGU\ZDOO
REAR WALL TEMPLATE
C
L
49-80271 JR 07-04
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
ALIGN BOTTOM EDGE WITH
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
5-1/16"
9-5/8"
8-1/8"
2-1/16"
13-3/4"
12-3/4"
Ceiling
3-3/4” c enterline to wall
6-1/2” dia. hole
)RUFHLOLQJYHQWGXFWLQJ
Centerline
3-3/4” min.
above top
mounting
bracket holes
)25:$//9(17'8&7
Centerline of
Installation
Space
8" Min. Opening for Ductwork
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
6” min. opening for ductwork
Centerline of
installation
space
View from rear
cleats
´[´PLQ
mounting
support
 49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
2
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
Ŷ:LWKWKHWHPSODWHWDSHGLQSODFHXVHDSXQFKWR
mark all mounting screw locations.
Ŷ'ULOO´SLORWKROHVDWWKHSXQFKHGORFDWLRQV
Ŷ5HPRYHWKHWHPSODWH
Ŷ7KHKROHVLQWKHVXSSRUWEUDFNHWKROHVPXVWHQWHU
studs or the horizontal support.
Ŷ8VHZRRGVFUHZVWRVHFXUHWKHPRXQWLQJEUDFNHWWR
the wall. The screws must engage wall studs or the
installed horizontal mounting support.
Ŷ&KHFNWREHVXUHWKDWWKHEUDFNHWLVOHYHO7KHUHLV
no way to level the hood after hanging it from this
bracket.
3
INSTALL DUCT BRACKET
The duct bracket must be intalled against the ceiling.
This bracket will hold the duct cover in place at the
top.
Secure the bracket to the ceiling and wall:
Ŷ$OLJQWKHPDUNHGFHQWHUOLQHRQWKHEUDFNHWZLWKWKH
centerline on the wall.
Ŷ0DUNWKHVFUHZKROHORFDWLRQVLQWKHFHLOLQJ
Ŷ'ULOO´SORWKROHVLQWKHPDUNHGORFDWLRQV
Ŷ,ISLORWKROHVGRQRWHQWHUVWXGVHQODUJHWKHKROHVWR
3/8” and install wall fastener anchors.
Ŷ'ULYHVFUHZVE\KDQGLQWRWKHIDVWHQHUVWRDOORZ
DQFKRUVWRH[SDQG5HPRYHWKHVFUHZV
Ŷ6HFXUHWKHEUDFNHWWRWKHFHLOLQJDQGZDOOZLWKZRRG
screws and/or fasteners.
C
L
49-80267 Rev. 4 11
Installation Instructions
WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
4
PREPARE THE HOOD
Ŷ5HPRYHWKHKRRGIURPWKHER[5HPRYHSDFNDJLQJ
and tape.
Ŷ5HPRYHRQHVFUHZRQHDFKVLGHRIWKHFRYHURQ
the electrical panel. Lift off the cover and set aside
with screws.
Ŷ6WDQGWKHHOHFWULFDOSDQHOXSULJKW
Ŷ$OLJQWKHVFUHZKROHVLQWKHERWWRPRIWKHSDQHO
with the holes on the base of
the hood at the front side.
Ŷ,QVWDOOVFUHZVSURYLGHG
5
MOUNT THE HOOD
Ŷ/LIWWKHKRRGRQWRWKHPRXQWLQJEUDFNHW
Ŷ&KHFNWREHVXUHLWLVOHYHO
Ŷ,QVWDOOZRRGVFUHZVWKURXJKWKHKRRGDQGLQWRWKH
wall on each side of the mounting bracket.
Ŷ([WHQGWKHFDQRS\IRUZDUGIRUEHWWHUDFFHVVWRWKH
rear mounting screw holes.
Ŷ,QVWDOOZRRGVFUHZVRUIDVWHQHUVWKURXJKWKH
bottom of the hood into the wall.
Remove 2 side
cover screws
Electrical
panel
Secure electrical
panel with 3
screws
-XQFWLRQER[
Inside screw
Install a wood
screw on each
side of the
mounting frame
Mounting
bracket
Install bottom
mounting screws
12 49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
6
CONNECT DUCTWORK
Ŷ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQRI
airflow as illustrated.
Ŷ3XVKGXFWRYHUWKHH[KDXVWRXWOHWDQGGDPSHU
Ŷ6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
Ŷ:UDSDOOGXFWMRLQWVZLWKGXFWWDSHIRUDQDLUWLJKW
seal.
Ŷ8VHGXFWWDSHWRVHDOWKHIODQJHFRQQHFWLRQV
CAUTION
Do not use sheet metal screws at
the hood flange connection. Doing so will prevent
proper damper operations. Seal connection with tape
only.
ATTENTION
Il ne faut pas utiliser de vis
DXWRUDXUGHXVHVjODFRQQH[LRQGXFROOHWGHODKRWWH&HFL
HPSrFKHUDLWOHERQIRQFWLRQQHPHQWGXUHJLVWUH1¶XWLOLVHU
TXHGXUXEDQDGKpVLISRXUDVVXUHUO¶pWDQFKpLWpGXUDFFRUG
6
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH
LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH
WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG
aluminum-to-copper connectors.
AVERTISSEMENT
Si la maison n’est pas câblee avec
GHX[ILOVHWXQILOGHWHUUHO¶LQVWDOODWHXUGRLWLQVWDOOHUXQILOGH
WHUUH4XDQGOHVILOVVRQWHQDOXPLQLXPLOIDXWSUHQGUHVRLQ
d’utiliser des connecteurs aluminium à cuivre avec une pâte
DQWLR[\GDQWHDSSURXYpHSDU8/
Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXW
Ŷ8VHDFRQGXLWFRQQHFWRUWRVHFXUHWKHFRQGXLWWR
WKHMXQFWLRQER[
Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU
Be sure wires are not pinched.
Ŷ6HFXUHHOHFWULFDOSDQHOFRYHUZLWKRULJLQDOVFUHZV
Duct tape
over seam
and screw
Screw
$LUIORZ
49-80267 Rev. 4 13
Installation Instructions
WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
8
INSTALL DUCT COVERS
Ŷ3ODFHWKHGHFRUDWLYHGXFW
covers on top of the hood.
NOTE: The inside (upper)
duct piece has holes on one
end. The holes are intended
for use when the hood is
installed for recirculating
purposes. Slide the vented
HQGLQWRWKHRXWHUSLHFHWKH
vent holes should not be
visible in this installation.
The inside duct piece must slip into the folded ends of
the outer section.
Ŷ([WHQGWKHLQQHUGXFWXSZDUGVWRWKHFHLOLQJ
bracket.
Ŷ6HFXUHGXFWFRYHUWRFHLOLQJEUDFNHWZLWKVFUHZV
Ŷ6HFXUHWKHORZHUGXFWFRYHUWRWKHKRRGE\
installing 2 screws from the bottom of the hood into
the duct cover.
9
INSTALL FILTERS
Ŷ5HPRYHSURWHFWLYHILOPRQWKHILOWHUV
Ŷ7LSWKHILOWHULQWRWKHVORWVDWWKHUHDURIWKHRSHQLQJ
Lift the filter lock and pull forward until the filter rests
in the slots.
Ŷ,QVWDOOERWKPHWDOJUHDVHILOWHUV
Ŷ7RUHPRYHWKHILOWHUVSUHVVLQZDUGVRQWKHKDQGOH
and pull the filter downwards.
10
FINALIZE INSTALLATION
Ŷ5HPRYHDOOSDFNDJLQJPDWHULDOV
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
Mounting
screws
,QVWDOOVFUHZV
duct cover and into
ceiling bracket
Install
2 bottom
duct cover
screws
)LOWHU/RFNV
NOTE: The charcoal filter is not required for this installation.
14 49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—RECIRCULATING
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT:)UDPLQJPXVWEHFDSDEOHRIVXSSRUWLQJ
OEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the mounting screw location. The
horizontal support must be flush with the room side
of the studs. Use cleats behind both sides of the
support to secure to wall studs.
IMPORTANT: Reinstall drywall for an even mounting
surface.
DUCTWORK, WIRING LOCATIONS
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
Ŷ0HDVXUHIURPWKHIORRUWRWKHWRSRIWKHFRRNLQJ
VXUIDFH$GGKRRGLQVWDOODWLRQKHLJKWGHWHUPLQHGRQ
SDJH0DUNWKDWORFDWLRQ
Ŷ7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKHSHQFLOHGOLQH
&+(&.72%(685(7+(7(03/$7(,6/(9(/
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOO´WR´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHULJKW
side of the centerline.
REAR WALL TEMPLATE
C
L
49-80271 JR 07-04
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
ALIGN BOTTOM EDGE WITH
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
5-1/16"
9-5/8"
8-1/8"
2-1/16"
13-3/4"
12-3/4"
Ceiling
Centerline of
Installation
Space
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
Centerline of
installation
space
View from rear
cleats
´[´PLQ
mounting
support
49-80267 Rev. 4 15
Installation Instructions
WALL-MOUNTED INSTALLATION—RECIRCULATING
3
PREPARE THE HOOD
Ŷ5HPRYHWKHKRRGIURPWKHER[5HPRYHSDFNDJLQJ
and tape.
Ŷ5HPRYHRQHVFUHZRQHDFKVLGHRIWKHFRYHURQ
the electrical panel. Lift off the cover and set aside
with screws.
Ŷ6WDQGWKHHOHFWULFDOSDQHOXSULJKW
Ŷ$OLJQWKHVFUHZKROHVLQWKH
bottom of the panel with the
holes on the base of the
hood at the front side.
Ŷ,QVWDOOVFUHZVSURYLGHG
2
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
Ŷ:LWKWKHWHPSODWHWDSHGLQSODFHXVHDSXQFKWR
mark all mounting screw locations.
Ŷ'ULOO´SLORWKROHVDWWKHSXQFKHGORFDWLRQV
Ŷ5HPRYHWKHWHPSODWH
Ŷ7KHKROHVLQWKHVXSSRUWEUDFNHWKROHVPXVWHQWHU
studs or the horizontal support.
Ŷ8VHZRRGVFUHZVWRVHFXUHWKHPRXQWLQJEUDFNHWWR
the wall. The screws must engage wall studs or the
installed horizontal mounting support.
Ŷ&KHFNWREHVXUHWKDWWKHEUDFNHWLVOHYHO7KHUHLV
no way to level the hood after hanging it from this
bracket.
Remove 2 side
cover screws
Electrical
panel
Secure electrical
panel with 3
screws
-XQFWLRQER[
Inside screw
16 49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—RECIRCULATING
5
SIZE AND CUT DUCT PIECE
(cont.)
Ŷ&XWWKHGXFWSLHFHWRVL]HDQG
slip onto the bottom of the duct
connector.
Ŷ8VHGXFWWDSHWRVHDODQGVHFXUH
the duct piece to the connector.
Ŷ3ODFHWKHDVVHPEO\RYHUWKHKRRG
outlet.
Ŷ+ROGWKHDVVHPEO\DJDLQVW
the ceiling. The penciled
centerline should show
through the slot in the
deflector. Mark the screw
holes on the sides of the
assembly.
Ŷ5HPRYHWKHDVVHPEO\DQG
drill 1/8” pilot holes into the
wall studs.
Ŷ(QODUJHKROHVWKDWGLGQRW
enter studs to 3/8” and tap
SODVWLFRUPHWDODQFKRUVLQWRWKHKROHVIOXVKZLWK
the wall.
Ŷ0RXQWWKHDVVHPEO\RQWRWKHKRRGRXWOHWSXVKXS
against the ceiling and install the screws provided.
CAUTION
Do not use sheet metal screws at
the hood flange connection. Doing so will prevent
proper damper operations. Seal connection with tape
only.
ATTENTION
1¶XWLOLVH]SDVGHYLVDXWRWDUDXGHXVHV
pour connecter le rabat de la hotte. En utilisant des
YLVYRXVHPSrFKH]OHERQIRQFWLRQQHPHQWGXYROHWGH
fermeture. cellez la connection uniquement avec du ruban
DGKpVLI
5
SIZE AND CUT DUCT PIECE
Ŷ+ROGXSSHUDLUGHIOHFWRUZLWKGXFWFRQQHFWRUDJDLQVW
the ceiling.
Ŷ0HDVXUHIURPWKHERWWRPRIWKHDLUGHIOHFWRUWRWKH
top of the hood as shown.
Reduce that dimension by
1” to facilitate installation.
The duct will cover and
overlap the deflector and
the hood outlets.
4
MOUNT THE HOOD
Ŷ/LIWWKHKRRGRQWRWKHPRXQWLQJEUDFNHW
Ŷ&KHFNWREHVXUHLWLVOHYHO
Ŷ,QVWDOOZRRGVFUHZVWKURXJKWKHKRRGDQGLQWRWKH
wall on each side of the mounting bracket.
Ŷ([WHQGWKHFDQRS\IRUZDUGIRUEHWWHUDFFHVVWRWKH
rear mounting screw holes.
Ŷ,QVWDOOZRRGVFUHZVRUIDVWHQHUVWKURXJKWKH
bottom of the hood into the wall.
Install a wood screw
on each side of the
mounting frame
Mounting
bracket
Install bottom
mounting screws
Duct length
Measure
length
49-80267 Rev. 4 
Installation Instructions
WALL-MOUNTED INSTALLATION—RECIRCULATING
6
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH
LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH
WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG
aluminum-to-copper connectors.
AVERTISSEMENT
Si la maison n’est pas câblee avec
GHX[ILOVHWXQILOGHWHUUHO¶LQVWDOODWHXUGRLWLQVWDOOHUXQILOGH
WHUUH4XDQGOHVILOVVRQWHQDOXPLQLXPLOIDXWSUHQGUHVRLQ
d’utiliser des connecteurs aluminium à cuivre avec une pâte
DQWLR[\GDQWHDSSURXYpHSDU8/
Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXW
Ŷ8VHDFRQGXLWFRQQHFWRUWRVHFXUHWKHFRQGXLWWR
WKHMXQFWLRQER[
Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%H
sure wires are not pinched.
Ŷ6HFXUHHOHFWULFDOSDQHOFRYHUZLWKRULJLQDOVFUHZV
7
INSTALL DUCT COVERS
Ŷ3ODFHWKHGHFRUDWLYHGXFW
covers on top of the hood.
NOTE: The inside piece has vent
holes on one end intended for
use when the hood is installed for
recirculating purposes. Be sure
the vented end is at the top; the
vent holes will be visible in this
installation.
The inside duct piece must slip
into the folded ends on the outer
section.
Ŷ([WHQGWKHLQQHUGXFWSLHFHXSZDUGVWRWKHFHLOLQJ
mounted air deflector.
Ŷ6HFXUHWKHGXFWFRYHUWRWKHDLUGHIOHFWRUGULYLQJ
one screw on each side.
Ŷ/RFDWHWKHVFUHZKROHVRQWKHERWWRPRXWVLGHHGJH
of the hood.
Ŷ6HFXUHWKHORZHUGXFWFRYHUWRWKHKRRGE\
installing 2 screws from the bottom of the hood into
the duct cover.
Mounting
screws
Vent
holes
Install
2 bottom
duct cover screws
,QVWDOOVFUHZV
duct cover and into
ceiling bracket
18 49-80267 Rev. 4
Installation Instructions
WALL-MOUNTED INSTALLATION—RECIRCULATING
8
INSTALL FILTERS
Charcoal filter
Ŷ5HPRYHSURWHFWLYHILOPVRQWKHILOWHUV
Ŷ,QVHUWWKHEODFNFKDUFRDOILOWHULQWRWKHFHQWHU
opening.
Metal grease filters
Ŷ7LSILOWHUVLQWRWKHVORWVDWWKHUHDURIWKHRSHQLQJ
Lift the filter lock and pull forward until the filter rests
in the slots.
Ŷ,QVWDOOERWKPHWDOJUHDVHILOWHUV
Ŷ7RUHPRYHWKHILOWHUVSUHVVLQZDUGVRQWKHKDQGOH
and pull the filter downwards.
9
FINALIZE INSTALLATION
Ŷ5HPRYHDOOSDFNLQJPDWHULDO
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
)LOWHU/RFNV
49-80267 Rev. 4 
UNDER-CABINET INSTALLATION
Installation Instructions
CABINET REQUIREMENTS
This hood may be installed beneath a wall-mounted
cabinet.
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
Ŷ,IWKHFDELQHWKDVEHHQLQVWDOOHGLWPXVWEH
removed so that wall framing supports can be
added.
7KHFDELQHWPXVWEHDWOHDVW´KLJKEHWZHHQWKH
bottom frame and the inside top. If the cabinet is not
´IURPERWWRPWRLQVLGHWRSDFXVWRPFDELQHWRU
modifications to a different size cabinet and/or soffit
may be required to accommodate the hood housing.
Ŷ7KHFDELQHWPXVWEH´ZLGHDQGDWOHDVW´GHHS
Ŷ7KHFDELQHWPXVWEHILUPO\VHFXUHGWRZDOOVWXGV
or the added framing support and capable of
VXSSRUWLQJSRXQGV
DUCTWORK, WIRING LOCATIONS
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKH5HDU:DOO7HPSODWHSDFNHGZLWKWKH
literature.
Ŷ0HDVXUHIURPWKHIORRUWRWKHWRSRIWKHFRRNLQJ
VXUIDFH$GGWKHSUHGHWHUPLQHGKRRGLQVWDOODWLRQ
height. Mark that location.
Ŷ8VHDOHYHOWRGUDZDVWUDLJKWSHQFLOOLQHRQWKHZDOO
Ŷ7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKHSHQFLOHGOLQH
Check to be sure the template is level.
Ŷ8VHWKHOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
Ŷ0HDVXUH´IURPWKHEDFNZDOOWRWKHFHQWHUOLQH
of a 6-1/2” hole on the ceiling.
NOTE: ,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOOWKLFNQHVV
to the 3-3/4” dimension.
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOO´WR´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHULJKW
VLGHRIWKHFHQWHUOLQH:LULQJVKRXOGHQWHUDWOHDVW´
above the bracket on the right side.
24” Min.
´0LQ
19-1/2"
11-3/4"
11"
´
11-3/4”
´
REAR WALL TEMPLATE
C
L
49-80271 JR 07-04
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
ALIGN BOTTOM EDGE WITH
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
5-1/16"
9-5/8"
8-1/8"
2-1/16"
13-3/4"
12-3/4"
Ceiling
3-3/4” centerline
to wall
Top frame mounting
screw locations
 49-80267 Rev. 4
Installation Instructions
UNDER-CABINET INSTALLATION
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT:)UDPLQJPXVWEHFDSDEOHRIVXSSRUWLQJ
OEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the mounting screw location. The
horizontal support must be flush with the room side
of the studs. Use cleats behind both sides of the
support to secure to wall studs.
Ŷ5HLQVWDOOGU\ZDOO
Centerline of
Installation
Space
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
Centerline of
installation
space
View from rear
cleats
´[´PLQ
mounting
support
2
PREPARE THE HOOD
Ŷ5HPRYHWKHKRRGIURPWKHER[5HPRYHSDFNDJLQJ
and tape.
Ŷ5HPRYHRQHVFUHZRQHDFKVLGHRIWKHFRYHURQ
the electrical panel. Lift off the cover and set aside
with screws.
Ŷ6WDQGWKHHOHFWULFDOSDQHOXSULJKW
Ŷ$OLJQWKHVFUHZKROHVLQWKH
bottom of the panel with the
holes on the base of the
hood at the front side.
Ŷ,QVWDOOVFUHZVSURYLGHG
Remove 2 side
cover screws
Electrical
panel
Secure electrical
panel with 3
screws
-XQFWLRQER[
Inside screw
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

GE ZV800SJSS Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI