GE ZV925SLSS Installation guide

Type
Installation guide
INSTALLATION
INSTRUCTIONS
36” Island Chimney Vent Hood
ZV925
MONOGRAM.COM
2 49-80329 Rev. 5
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ IMPORTANT Save these instructions
for local inspector’s use.
Ŷ IMPORTANT Observe all governing
codes and ordinances.
ŶNote to Installer Be sure to leave these
instructions with the Consumer.
ŶNote to Consumer Keep these instructions with
your Owner’s Manual for future reference.
ŶSkill Level Installation of this appliance requires
basic mechanical and electrical skills.
ŶCompletion Time — 1 to 3 Hours.
Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
covered under the warranty.
Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca
Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW
monogram.com/use-and-care/parts.
CAUTION
Due to the weight and size of these
vent hoods and to reduce the risk of personal injury
RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
ATTENTION
À cause du poids et de la taille de
ces hottes et pour reduire le risque de blessures et
GHGRPPDJHVIL FAUT DEUX PERSONNES POUR
FAIRE L’INSTALLATION CORRECTEMENT.
WARNING
To reduce the risk of fire or electrical
VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO
VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.
AVERTISSEMENT
3RXUUpGXLUHOHULVTXH
G¶LQFHQGLHRXGHFKRFpOHFWULTXHLOQHIDXWSDV
XWLOLVHUFHWWHKRWWHDYHFXQUpJXODWHXUGHYLWHVVH
pOHFWURQLTXHH[WHUQH7RXWHPRGLILFDWLRQGHFHW\SHGX
branchement d’usine peute endommager l’appareil ou
FUpHUXQULVTXHGHFKRFpOHFWULTXH
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING
725('8&(7+(5,6.2)),5(
(/(&75,&$/6+2&.25,1-85<723(56216
2%6(59(7+()2//2:,1*
$8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH
PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW
the manufacturer.
%%HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH
power off at the service panel and lock the service
disconnecting means to prevent the power from
EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH
GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\
IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ
to the service panel.
AVERTISSEMENT
32855e'8,5(/(5,648(
'¶,1&(1',('(&+2&e/(&75,48(28'(
%/(6685(6,/)$872%6(59(5/(65(*/(6
68,9$17(6
$8WLOLVHUFHWDSSDUHLOXQLTXHPHQWGHODPDQLpUH
SUpYXHSDUOHIDEULFDQW(QFDVGHTXHVWLRQ
consulter le fabricant.
%$YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSHU
O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOHU
OHSDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXV
tension accidentelle. S’il n’est pas possible de
YHUURXLOOHUOHSDQQHDXGXGLVFRQFWHXUDWWDFKHUXQ
SODFDUGRXXQHpWLTXHWWHWUpVYLVLEOHDXSDQQHDX
Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW
KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
wiring must be done by qualified person(s) in
accordance with all applicable codes and standards
including fire-rated construction.
Ŷ6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ
the heating equipment manufacturer’s guidelines
and safety standards such as those published by
WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQG
WKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG
$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQGWKHORFDO
FRGHDXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS
(replacement) air system in accordance with local
EXLOGLQJFRGHUHTXLUHPHQWV9LVLW*($SSOLDQFHVFRP
for available makeup air solutions.
Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDOFRQQHFWLRQV
and grounding must comply with applicable codes.
,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH
LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH
$16,1)3$RUODWHVWHGLWLRQ
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer
XQFRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXH
G¶LQFHQGLHHWSRXYRLUpYDFXHUO¶DLUFRUUHFWHPHQW,O
QHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDV
pYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXU
XQSODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQ
garage.
49-80329 Rev. 5 3
Design Information
CONTENTS
Design Information
3URGXFW'LPHQVLRQV ...................................................... 3
Advance Planning
$GYDQFH3ODQQLQJ ........................................................ 4
3RZHU6XSSO\ ...............................................................4
'XFW)LWWLQJV ................................................................ 5
Installation Preparation
Tools and Materials Required ....................................... 6
5HPRYHWKH3DFNDJLQJ ................................................ 6
Installation Height .........................................................
3DUWV3URYLGHG .............................................................. 8
Installation Preparation
Construct Ceiling Support .............................................
Installation Instructions—Vented to the Outside
6WHS0RXQW7HPSODWH .............................................. 12
6WHS$GMXVW)UDPH+HLJKW ....................................... 12
6WHS&XW'XFWWR/HQJWKIRU9HQWHG,QVWDOODWLRQ...... 13
6WHS,QVWDOOWKH6XSSRUW)UDPH ............................... 13
6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV ..................... 13
6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 14
6WHS&RQQHFW&DEOHV .............................................. 14
6WHS&RQQHFW(OHFWULFDO ........................................... 15
6WHS3UHSDUHWKH'XFW&RYHUV ................................ 16
6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 16
6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 
6WHS,QVWDOO'XFW&RYHU7ULP ................................. 
6WHS,QVWDOO0HWDO)LOWHU.......................................... 
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 
Installation Instructions—Recirculating
6WHS0RXQW7HPSODWH .............................................. 18
6WHS$GMXVW)UDPH+HLJKW ....................................... 18
6WHS,QVWDOO$LU'HIOHFWRU&XW'XFW
for Recirculating Operation ............................. 
6WHS,QVWDOO8SSHU6XSSRUW)UDPH .......................... 
6WHS,QVWDOO/RZHU6WUXFWXUHWR8SSHU6WUXFWXUH ..... 
6WHS,QVWDOO%ORZHU0RWRU ........................................ 
6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV ..................... 
6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 
6WHS&RQQHFW&DEOHV .............................................. 21
6WHS&RQQHFW(OHFWULFDO ......................................... 21
6WHS3UHSDUHWKH'XFW&RYHUV .............................. 22
6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 22
6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 22
6WHS,QVWDOO'XFW&RYHU7ULP ................................. 23
6WHS,QVWDOO)LOWHUV .................................................. 23
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 23
PRODUCT DIMENSIONS
These vent hoods are supplied with a support frame for
FHLOLQJKHLJKWVRI¶´WR¶´
Decorative duct covers conceal the ductwork running
from the top of the hood to the ceiling.
=;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJKHLJKWVRI
¶´WR¶´
NOTE: Installation height should be measured from the
cooking surface to the bottom of the outer glass portion
of the hood.
7KLVKRRGPXVWEHLQVWDOOHG´PLQDQG´PD[
above the cooking surface. The cooking surface should
EHDWOHDVW´DERYHWKHIORRU
7KLVKRRGPD\EHYHQWHGWRWKHRXWGRRUVRULWFDQEH
installed for recirculating operation.
This hood can be installed over any Monogram electric
or gas cooktop. It cannot be installed over a Monogram
3URIHVVLRQDOFRRNWRSRUUDQJH
 7KHVXSSOLHGGXFWFRYHUILWV¶´WR¶FHLOLQJKHLJKWV
)RU¶´WR¶´FHLOLQJVRUGHU=;
27 9/16"
3 1/4"
35 7/8"
*Height
to
Ceiling
2 3/4"
*Height to
ceiling


24" min.*
PD[
36" min.
([DFWLQVWDOODWLRQ
height depends on
ceiling height.
4 49-80329 Rev. 5
Installation Preparation
ADVANCE PLANNING
Ductwork Planning
Ŷ7KHVHYHQWKRRGVDUHHTXLSSHGIRU´URXQG
ductwork.
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOG
QRWH[FHHGIWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configurations.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH
PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ8VHULJLGPHWDOGXFWZRUNRQO\
Ŷ,QVWDOODURRIFDSZLWKGDPSHUDWWKHH[WHULRU
opening. Order the cap and any transitions needed
in advance.
Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
air system in accordance with local building code
UHTXLUHPHQWV9LVLW*($SSOLDQFHVFRPIRUDYDLODEOH
makeup air solutions.
Ductwork Planning
Ŷ7KHVHYHQWKRRGVDUHKHDY\$GHTXDWHVWUXFWXUDO
support must be provided. The ceiling structure
must be capable of supporting the weight of the
hood and any inadvertent user contact loads
DSSUR[LPDWHO\SRXQGV7KHKRRGVXSSRUW
IUDPHZLOOEHVXSSRUWHGE\[FURVVIUDPLQJ
Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHG
before the cooktop or countertop below is installed.
Accessory Duct Cover
Ŷ$OOPRGHOVDUHVKLSSHGZLWKDGXFWFRYHUIRUFHLOLQJ
KHLJKWVRI¶´WR¶
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
AVERTISSEMENT
3285'(65$,6216
'(6e&85,7e&(7$33$5(,/'2,7Ç75(
&255(&7(0(170,6¬/$7(55(
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWK
WKLVDSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRU
prevailing local codes and ordinances.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]
DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG
EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJLQWKHFHLOLQJDVFORVHWRWKH
LQVWDOODWLRQORFDWLRQDVSRVVLEOH$OORZDGGLWLRQDO
OHQJWKIURPFHLOLQJMRLVWVWRUHDFKWKHMXQFWLRQER[
on the bottom of the hood support frame.
Ŷ&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil
GHPLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(Q
FDVGHGRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQ
WHFKQLFLHQSRXUGpWHUPLQHUVLO¶DSSDUHLOHVWjODWHUUH
=;DFFHVVRU\ duct cover is available
WRUHDFK1" WR1" ceiling heights. The
accessory should be ordered with the hood and be
on site before final framing and wall finishing.
49-80329 Rev. 5 5
Installation Preparation
DUCT FITTINGS
This Hood Must Use an 8” Round
Duct. It Can Transition to a
3-1/4” x 12” Duct.
8VHWKLVFKDUWWRFRPSXWHPD[LPXPSHUPLVVLEOHOHQJWKV
for duct runs to outdoors.
NOTE:'RQRWH[FHHGPD[LPXPSHUPLVVLEOHHTXLYDOHQW
lengths!
Maximum duct length: 100 foot for range hoods.
Flexible ducting
,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOOWKHHTXLYDOHQWIHHW
YDOXHVLQWKHWDEOHVKRXOGEHGRXEOHG7KHIOH[LEOHPHWDO
GXFWVKRXOGEHVWUDLJKWDQGVPRRWKDQGH[WHQGHGDV
much as possible.
DO NOTXVHIOH[LEOHSODVWLFGXFWLQJ
NOTE: $Q\KRPHYHQWLODWLRQV\VWHPVXFKDVD
YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUIORZRI
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\ILUHSODFHVJDV
IXUQDFHVJDVZDWHUKHDWHUVDQGRWKHUQDWXUDOO\YHQWHG
systems. To minimize the chance of interruption of such
QDWXUDOO\YHQWHGV\VWHPVIROORZWKHKHDWLQJHTXLSPHQW
manufacturer’s guidelines and safety standards such
DVWKRVHSXEOLVKHGE\1)3$DQG$6+5$(:KHQ
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
Duct Piece Dimensions
Equivalent
Length*
Quantity
Used
Total
Equivalent
Length
5RXQG
straight
1 ft. (per foot
length)
´[´
straight
1 ft. (per foot
length)
HOERZ IW
HOERZ IW
´[´
HOERZ
43 ft.
´[´
HOERZ
26 ft.
´[´
IODW
elbow
IW
´URXQGWR
´[´
transition
2 ft.
´[´
WR´URXQG
transition
5 ft.
´URXQGWR
´[´
WUDQVLWLRQ
elbow
6 ft.
´[´
WR´URXQG
WUDQVLWLRQ
elbow
13 ft.
Round wall
cap with
damper
32 ft.
´[´
wall cap with
damper
IW
Round roof
cap
44 ft.
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJ
equivalent. Equivalent length of duct pieces
DUHEDVHGRQDFWXDOWHVWVFRQGXFWHGE\*(
$SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFW
requirements for good venting performance
with any ventilation hood.
Total Duct Run
6 49-80329 Rev. 5
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
REMOVE THE PACKAGING
CAUTION
/,)77+(+22'2872)7+(%2;
%<7+(&(17(50(7$/3257,21'2127/,)7%<
7+(*/$666,'(6
ATTENTION
/(9(=/$+277(¬/¶(;7e5,(85
'(/$%2Ì7(3$5/$3257,210e7$/&(175$/
1(/(9(=3$63$5/(6&Ð7e6'(9(55(
CAUTION
:HDUJORYHVWRSURWHFWDJDLQVW
sharp edges.
ATTENTION
3RUWH]GHVJDQWVSRXUpYLWHUOHV
EOHVVXUHVFDXVpHVSDUOHVWUDQFKDQWV
Ŷ*UDVSWKHKRRGE\WKHPHWDOLQVHUWLQWKHFHQWHUDQG
OLIWVWUDLJKWXSDQGRXWRIWKHER[
Ŷ5HPRYHDQGSURSHUO\GLVFDUGWKHSODVWLFZUDSSLQJ
Ŷ5HPRYHSDUWVER[GXFWFRYHUVDQGRWKHUSDFNDJLQJ
3HQFLODQGWDSHPHDVXUH
3OLHUV
9+]RU$PS
2-wire with ground. properly
grounded branch circuit.
Key hole saw
:LUHFXWWHUVWULSSHU
Step ladder
Metal snips
Saber saw
or sawsall
:LUHQXWV
3KLOOLSVDQG
flat blade
screwdrivers
Strain relief for
junction cover.
Spirit level
)ODVKOLJKW
Safety glasses
8" round metal
GXFWOHQJWKWR
suit installation.
Duct tape
3/8" swivel
socket or pivoting
KH[VRFNHWZLWK
H[WHQVLRQV
Carpenter’s square
Hammer
Electric or battery-operated drill
DQGELWV3KLOOLSVDQGIODW
blade screwdriver bits.
49-80329 Rev. 5
Installation Preparation
DETERMINE INSTALLATION HEIGHT
Ŷ'HFRUDWLYHGXFWFRYHUVDUHSURYLGHGWRFRQFHDOWKH
ductwork running to the ceiling.
Ŷ7KLVKRRGFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ
RSHUDWLRQ1RNLWVUHTXLUHG
7KHKRRGLQVWDOODWLRQKHLJKWIURPWKHFRRNLQJVXUIDFH
WRWKHERWWRPRIWKHKRRGGHSHQGVXSRQFHLOLQJ
height.
)RURSWLPXPSHUIRUPDQFHWKHKRRGPXVWEH´PLQ
DQG´PD[DERYHWKHFRRNLQJVXUIDFH
Use the chart on this page to accurately determine
LQVWDOODWLRQKHLJKWDQGVXSSRUWIUDPHDGMXVWPHQWDQG
WRVHOHFWWKHFRUUHFWVL]HWRSWULPSLHFH$%&RU'
=;$FFHVVRU\'XFWFRYHULQFOXGHVD´
long duct cover and 3 sets of duct cover top trim
SLHFHVODEHOHG()*
D
C
B
$
Ceiling
Height
Possible Hood
Installation
Height (inches)
Mounting Frame
Height (inches)
Trim
Needed
 26  $
8’   $
 24 34 1/2 B
 28  $
 25 34 1/2 B
   $
3" 26 34 1/2 B
   $
  34 1/2 B
 24 38 1/2 C
 28 34 1/2 B
 25 38 1/2 C
  34 1/2 B
 26 38 1/2 C
  34 1/2 B
  38 1/2 C
 24 42 1/2 D
 28 38 1/2 C
 25 42 1/2 D
  38 1/2 C
 26 42 1/2 D
  38 1/2 C
  42 1/2 D
ZX92510 Accessory Duct Cover
 24 46 1/2 E
 28 42 1/2 D
 25 46 1/2 E
  42 1/2 D
 26 46 1/2 E
3"  42 1/2 D
  46 1/2 E
 24  )
 28 46 1/2 E
 25  )
  46 1/2 E
 26  )
  46 1/2 E
   )
 24 54 1/2 *
 28  )
 25 54 1/2 *
   )
 26 54 1/2 *
   )
  54 1/2 *
 28 54 1/2 *
8 49-80329 Rev. 5
Installation Preparation
PARTS PROVIDED
Locate the parts packed with the hood.
HARDWARE PACKAGE
Locate and check
contents. Screws
shown actual size.
$LUGHIOHFWRUIRU
recirculating installation
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
Template
6 ceiling
mounting
screws
VFUHZVWRWDO
24 support frame screws
KRRGDWWDFKPHQW
screws
2 upper duct cover
attachment screws
4 recirculating
deflector screws
2 duct cover bracket
attachment screws
12 sheet
metal
screws
Decorative duct covers
(14"ZLGHGHHSZKHQDVVHPEOHG
12 cage
nuts
Telescoping support
frame
Upper duct cover trim pieces
2 each of 4 sizes
1 charcoal filter for
recirculating installation
Stainless steel filter
24-3/4"
23-1/4"
2 Duct cover
brackets
2 thumb
screws
Lower duct cover trim pieces
Note: Some additional hardware/screws included.
49-80329 Rev. 5
Installation Preparation
CONSTRUCT CEILING SUPPORT
Plan the Location of the Hood and Ductwork
ŶUse a plumb bob to check the location. The
countertop/cooktop below the hood must be
centered with the hood.
Ŷ7KHKRRGVKRXOGH[WHQGEH\RQGWKHIURQW
and rear edge of the cooking appliance.
ŶThe duct in the ceiling must be centered
over the cooktop.
Ceiling Support Structure
Ŷ$WWKHKRRGORFDWLRQLQVWDOO[FURVVIUDPLQJ
EHWZHHQFHLOLQJMRLVWVDVVKRZQ[¶VDUHUHTXLUHGWR
support the weight of the hood.)
Ŷ$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVWLQJ
structure.
Ŷ<RXUFHLOLQJMRLVWVZLOOEHOLNHRQHRIWKHIROORZLQJ
H[DPSOHV
Ceiling
Hood ducting
centerline
Cooktop
Countertop
)URQW

13-3/4"
Side view
$OLJQZLWKFHQWHU
of cooktop
Top view ceiling joists parallel to front of hood

Install cross-framing
symmetrically over duct/
cooktop centerline
16" joist
spacing

´GXFW
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFWWR
center of cooktop
(;$03/($
 49-80329 Rev. 5
Installation Preparation
CONSTRUCT CEILING SUPPORT (Cont.)
Top view ceiling joists run perpendicular to front of hood
Top view ceiling joists at angle to front of hood
LQVWDOO
cross-framing
symmetrically over
duct/cooktop
centerline
16" joist
spacing

8" duct
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFW
to center of
cooktop
LQVWDOOFURVV
framing symmetrically over
duct/cooktop centerline
16" joist
spacing

8" duct
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFW
to center of
cooktop
(;$03/(%
(;$03/(&
49-80329 Rev. 5 11
Installation Preparation
CONSTRUCT CEILING SUPPORT (Cont.(
Ŷ6HFXUHHDFK[EORFNZLWKDWOHDVWIRXU
ZRRGVFUHZV´ORQJQRWVXSSOLHG8VHZRRG
screws total for the two supports.
ŶThe cross framing must be accurately aligned to
assure correct positioning of the hood.
ŶThe cross framing must be level in all directions.
Check with a spirit level and adjust if necessary.
IMPORTANT: The ceiling structure must be capable of
VXSSRUWLQJWKHZHLJKWRIWKHKRRGDSSUR[LPDWHO\
pounds) and any inadvertent user contact loads. The
KRRGVXSSRUWIUDPHZLOOEHVXSSRUWHGE\WKH[FURVV
framing.
Ductwork for Installations Vented to the Outdoors
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRW
H[FHHGIHHWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configuration.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH
PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ7KLVYHQWKRRGPXVWXVH´URXQGULJLGGXFW
Ŷ,QVWDOOWKHKRXVHGXFWZRUNWRUXQKRUL]RQWDOO\EHWZHHQ
ceiling joists or straight up through the roof.
Finish the Ceiling
Ŷ)LQLVKWKHFHLOLQJVXUIDFH%HVXUHWRPDUNORFDWLRQRI
the ceiling joists and cross framing. Check to be sure
the ceiling is level; use shims if necessary.
Ceiling Joint
2x4
10"
Duct
Vent Straight Up
Through The Ceiling
8" Duct
Ceiling joist
[
Vent straight up through
the ceiling
Ceiling
Joist
10-3/4
2x 4
Mi
n.
Cross Framing
Height
Adjustment
Screw Holes
7-1/16"
[PLQFURVVIUDPLQJ
Ceiling
joist


Height
adjustment
screws
12 49-80329 Rev. 5
Installation Instructions
1
MOUNT TEMPLATE
Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG
tape in place.
Be sure the template is oriented correctly with the
front of the hood.
Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV
will provide parallel alignment with the countertop
below.
Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV
Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´
ELWDQGGULOODSSUR[LPDWHO\´GHHS
Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH
FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR
allow the screw head to engage the keyhole slots on
the support frames.
Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN
2
ADJUST FRAME HEIGHT
Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW
Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG
RQWKHFKDUWRQSDJH
Ŷ5HPRYHVFUHZVRQHDFKRIWKH
sides of the frame to loosen the upper
VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU
motor.
Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR
WKHFKDUWRQSDJH8VHDWRWDORI
32 screws (8 screws on each side)
WRVHFXUHWKHXSSHUVWUXFWXUHORZHU
structure and blower/motor together.
INSTALLATION—VENTED TO THE OUTSIDE
1/4" Gap
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
24"min.
PD[
36"min.
)UDPH
height
2-3/4"
Ceiling
height
X
49-80329 Rev. 5 13
Installation Instructions
3
CUT DUCT TO LENGTH FOR
VENTED
Ŷ0HDVXUHIURPKRXVH
GXFWWRH[KDXVW
opening.
Ŷ&XWWKH´GXFWOHQJWK
to size.
Ŷ6OLSGXFWRYHUWKH
H[KDXVWRSHQLQJ
Ŷ6HDOWKHFRQQHFWLRQ
with duct tape.
5
INSTALL HOOD ATTACHMENT
SCREWS
Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI
WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ
screw head and support flange.
4
INSTALL THE SUPPORT FRAME
Ŷ5DLVHWKHVXSSRUWWRZDUG
the ceiling.
Ŷ7KUHDGWKHKRXVHZLULQJ
through one of the large
KROHVSUHIHUDEO\RQWKHOHIW
side.
Ŷ&DUHIXOO\HQJDJHWKH
ceiling mounting screws to
WKHNH\KROHVORWV$1'WKH
house duct in the top of the
frame.
Ŷ7LJKWHQWKHPRXQWLQJ
screws against the frame.
Ŷ,QVWDOOVDIHW\VFUHZV
Ŷ8VHGXFWWDSHWRVHDOWKH
duct connection at the top.
INSTALLATION—VENTED TO THE OUTSIDE
Duct
House
duct
)UDPH
height
Duct
length
Duct
Safety screws
Keyhole
slots
House wiring
Keyhole
slots
Install 4
attachment
screws
14 49-80329 Rev. 5
Installation Instructions
INSTALLATION—VENTED TO THE OUTSIDE
7
CONNECT CABLES
Ŷ-RLQWKHWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKH
hood. Secure the cables behind the retainer clip.
6
MOUNT THE HOOD ONTO THE
SUPPORT
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGWRWKHERWWRPRIWKHVXSSRUWHQJDJLQJ
the keyhole slots to the 4 mounting screws.
Ŷ7LJKWHQWKHPRXQWLQJVFUHZV
Ŷ,QVWDOODGGLWLRQDOVFUHZVDVVKRZQ
Install
6 screws
Retainer clip
To lights
To control
panel
49-80329 Rev. 5 15
Installation Instructions
8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with a
JURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKHLQVWDOOHU
:KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWRXVH8/
DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR
copper connectors.
AVERTISSEMENT
Si le câblage de la maison n’est
SDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUHO¶LQVWDOODWHXU
GRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHVILOVGHOD
PDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQG¶XWLOLVHUGHOD
SkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQQHFWHXUV
pour l’aluminium-cuivre.
Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXWRQWKH
left side.
Ŷ6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWK
a strain relief.
Ŷ
Connect white leads to branch circuit white lead.
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU
Be sure wires are not pinched.
Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ
Knockout
-%R[FRYHU
INSTALLATION—VENTED TO THE OUTSIDE
-%R[FRYHU
House wiring
16 49-80329 Rev. 5
Installation Instructions
9
PREPARE THE DUCT COVERS
Ŷ5HPRYHWKHSODVWLFSURWHFWLYHFRYHULQJRQDOOGXFW
pieces.
Ŷ,QVWDOOFDJHQXWVRQHDFKLQVLGHVHFWLRQRIWKHWRS
duct cover. The cage nuts fit into the rectangular
VORWVFOLSVIDFLQJRXWZDUG
Ŷ,QVWDOOFDJHQXWVRQHDFKVLGHRIWKHORZHUGXFW
covers.
10
INSTALL UPPER DUCT COVER
Ŷ3ODFHWKHWDOOGXFWFRYHUVRQWRWKHWRSRIWKHKRRG
This section has venting holes on one end.
NOTE: If you are installing this hood for
UHFLUFXODWLQJRSHUDWLRQSODFHWKHGXFWFRYHUVRQWR
the hood with the venting slots at the top.
,IWKHKRRGLVYHQWHGWRWKHRXWVLGHWKHKROHV
should be positioned on the bottom.
Ŷ6HFXUHWKHVLGHVZLWKVFUHZVLQVWDOOHGWKURXJKWKH
cage nuts.
Ŷ5DLVHWKHDVVHPEOHGGXFWFRYHUVWRWKHWRSDJDLQVW
the ceiling.
Ŷ0DWFKPRXQWLQJKROHVRQHRQHDFKVLGH,QVWDOO
screws through the duct and into the support.
INSTALLATION—VENTED TO THE OUTSIDE
Support
frame
3ODQ
diagram
Rectangular slots
1XW
Top
sections
Top
sections
49-80329 Rev. 5 
Installation Instructions
11
INSTALL LOWER DUCT
Ŷ3ODFHUHDUGXFWFRYHURQWRWKHKRRG
Ŷ3ODFHIURQWGXFWFRYHURQWRWKHKRRG
Ŷ6HFXUHWKHGXFWFRYHUVZLWKVFUHZV
12
INSTALL DUCT COVER TRIM
Ŷ,QVWDOOVLGHEUDFNHWVWRVHFXUHWKHORZHUGXFWWLJKWO\
against the upper duct.
Ŷ+ROGORZHUWULPVWULSVQDUURZSLHFHVZLWKKRRNV
IDFLQJGRZQ3ODFHWKHKRRNVLQVLGHWKHVORWVDQG
slide downward.
Ŷ6HOHFWWKHFRUUHFWVL]HXSSHUWULPVWULSVDQGSUHVV
into place.
13
INSTALL METAL FILTER
IMPORTANT:&KHFNWREHVXUHWKDWWKHPDLQ21
2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ
Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKHRSHQLQJ
Lift the filter to the opposite side and into the filter
lock.
Ŷ7RUHPRYHWKHILOWHUSXOOWKHILOWHUORFNGRZQZDUG
14
FINALIZE INSTALLATION
Ŷ5HPRYHDOOWDSHDQGSDFNLQJPDWHULDO
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
INSTALLATION—VENTED TO THE OUTSIDE
)URQWERWWRPGXFWFRYHUVHFWLRQ
(snap into place and secure
with 6 screws 3 per side)
3ODQGLDJUDPWRS
view
)URQWERWWRPGXFW
cover sections
Upper
trim
strip
Lower
trim strip
Lower
trim
strip
Upper
trim
strip
Side
bracket
)LOWHUORFN
18 49-80329 Rev. 5
Installation Instructions
1
MOUNT TEMPLATE
Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG
tape in place.
Be sure the template is oriented correctly with the
front of the hood.
Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV
will provide parallel alignment with the countertop
below.
Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV
Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´
ELWDQGGULOODSSUR[LPDWHO\´GHHS
Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH
FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR
allow the screw head to engage the keyhole slots on
the support frames.
Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN
2
ADJUST FRAME HEIGHT
Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW
Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG
RQWKHFKDUWRQSDJH
Ŷ5HPRYHVFUHZVRQHDFKRIWKH
sides of the frame to loosen the upper
VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU
motor.
Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR
WKHFKDUWRQSDJH8VHDWRWDORI
32 screws (8 screws on each side)
WRVHFXUHWKHXSSHUVWUXFWXUHORZHU
structure and blower/motor together.
INSTALLATION—VENTED TO THE OUTSIDE
1/4" Gap
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
24"min.
PD[
36"min.
)UDPH
height
2-3/4"
Ceiling
height
X
Mark
each
piece to
indicate
where
screw
holes
align.
NOTE: Low ceilings may require that the
lower portion of the support frame be removed.
The upper support frame may be secured
directly to the blower/motor. Refer to the
FKDUWRQSDJHIRU\RXUFHLOLQJKHLJKWDQG
to be sure the duct cover trim piece will fit.
49-80329 Rev. 5 
3
INSTALL AIR DEFLECTOR,
CUT DUCT FOR RECIRCULATING
OPERATION
Ŷ7HPSRUDULO\VOLGHWKHDLUGHIOHFWRU
into the support frame.
Ŷ0HDVXUHGXFWOHQJWKEHWZHHQ
the deflector and over the
H[KDXVWRSHQLQJ
Ŷ&XWGXFWSLHFHWROHQJWKDQG
set aside.
4
INSTALL UPPER SUPPORT
FRAME
Ŷ5DLVHWKHXSSHUVXSSRUW
toward the ceiling.
Ŷ7KUHDGWKHKRXVHZLULQJ
through one of the large
KROHVSUHIHUDEO\RQWKHOHIW
side.
Ŷ&DUHIXOO\HQJDJHWKHFHLOLQJ
mounting screws to the
keyhole slots in the top of
the frame.
Ŷ7LJKWHQWKHPRXQWLQJVFUHZVDJDLQVWWKHIUDPH
Ŷ,QVWDOOVDIHW\VFUHZV
Ŷ6OLGHDLUGHIOHFWRU
into the support
frame.
Ŷ6HFXUHWKHGHIOHFWRU
to the support with
4 screws.
Ŷ,QVWDOOWKHGXFW
piece to the bottom
of the deflector
and seal the
connection with
duct tape.
Installation Instructions
INSTALLATION—RECIRCULATING
)5217
)5217
Duct
length
Safety
screws
Keyhole
slots
House wiring
Keyhole
slots
 49-80329 Rev. 5
Installation Instructions
INSTALLATION—RECIRCULATING
5
INSTALL LOWER STRUCTURE TO
UPPER STRUCTURE
Ŷ6OLGHORZHUIUDPHLQWRWKH
upper frame. Match the
marked alignment holes.
Ŷ6HFXUHWKHXSSHUDQGORZHU
IUDPHZLWKVFUHZVRQ
each side of the frame.
7
INSTALL HOOD ATTACHMENT
SCREWS
Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI
WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ
screw head and support flange.
8
MOUNT THE HOOD ONTO THE
SUPPORT
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGWRWKHERWWRP
RIWKHVXSSRUWHQJDJLQJ
the keyhole slots to the 4
mounting screws.
Ŷ7LJKWHQWKHPRXQWLQJ
screws.
Ŷ,QVWDOO
additional
screws as
shown.
6
INSTALL BLOWER/MOTOR
Ŷ5DLVHWKHEORZHU
motor piece toward the
assembled frame.
Ŷ&DUHIXOO\UDLVHWKHPRWRUWR
the marked reference point
while making sure the duct
piece slips over the blower
outlet flange.
Ŷ6HFXUHWKHEORZHUPRWRUWR
WKHIUDPHXVLQJVFUHZV
4 on each side.
Ŷ8VHWDSHWRVHDOWKHGXFW
connection.
Install 4
attachment
screws
Install 6 screws
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

GE ZV925SLSS Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI