GE ZV900SLSS Installation guide

Type
Installation guide
INSTALLATION
INSTRUCTIONS
36” Glass Canopy
Chimney Vent Hood
ZV900
MONOGRAM.COM
2 49-80328 Rev. 4
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ IMPORTANT Save these instructions
for local inspector’s use.
Ŷ IMPORTANT Observe all governing
codes and ordinances.
ŶNote to Installer Be sure to leave these
instructions with the Consumer.
ŶNote to Consumer Keep these instructions with
your Owner’s Manual for future reference.
ŶSkill Level Installation of this appliance requires
basic mechanical and electrical skills.
ŶCompletion Time — 1 to 3 Hours.
Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
covered under the warranty.
Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca
Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW
monogram.com/use-and-care/parts.
CAUTION
Due to the weight and size of these
vent hoods and to reduce the risk of personal injury
RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
ATTENTION
À cause du poids et de la taille de
ces hottes et pour reduire le risque de blessures et
GHGRPPDJHVIL FAUT DEUX PERSONNES POUR
FAIRE L’INSTALLATION CORRECTEMENT.
WARNING
To reduce the risk of fire or electrical
VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO
VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.
AVERTISSEMENT
3RXUUpGXLUHOHULVTXH
G¶LQFHQGLHRXGHFKRFpOHFWULTXHLOQHIDXWSDV
XWLOLVHUFHWWHKRWWHDYHFXQUpJXODWHXUGHYLWHVVH
pOHFWURQLTXHH[WHUQH7RXWHPRGLILFDWLRQGHFHW\SHGX
branchement d’usine peute endommager l’appareil ou
FUpHUXQULVTXHGHFKRFpOHFWULTXH
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING
725('8&(7+(5,6.2)),5(
(/(&75,&$/6+2&.25,1-85<723(56216
2%6(59(7+()2//2:,1*
$8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH
PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW
the manufacturer.
%%HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH
power off at the service panel and lock the service
disconnecting means to prevent the power from
EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH
GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\
IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ
to the service panel.
AVERTISSEMENT
32855e'8,5(/(5,648(
'¶,1&(1',('(&+2&e/(&75,48(28'(
%/(6685(6,/)$872%6(59(5/(65(*/(6
68,9$17(6
$8WLOLVHUFHWDSSDUHLOXQLTXHPHQWGHODPDQLpUH
SUpYXHSDUOHIDEULFDQW(QFDVGHTXHVWLRQ
consulter le fabricant.
%$YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSHU
O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOHU
OHSDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXV
tension accidentelle. S’il n’est pas possible de
YHUURXLOOHUOHSDQQHDXGXGLVFRQFWHXUDWWDFKHUXQ
SODFDUGRXXQHpWLTXHWWHWUpVYLVLEOHDXSDQQHDX
Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW
KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
wiring must be done by qualified person(s) in
accordance with all applicable codes and standards
including fire-rated construction.
Ŷ6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ
the heating equipment manufacturer’s guidelines
and safety standards such as those published by
WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQG
WKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG
$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQGWKHORFDO
FRGHDXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS
(replacement) air system in accordance with local
EXLOGLQJFRGHUHTXLUHPHQWV9LVLW*($SSOLDQFHVFRP
for available makeup air solutions.
Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDOFRQQHFWLRQV
and grounding must comply with applicable codes.
,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH
LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH
$16,1)3$RUODWHVWHGLWLRQ
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer
XQFRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXH
G¶LQFHQGLHHWSRXYRLUpYDFXHUO¶DLUFRUUHFWHPHQW,O
QHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDV
pYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXU
XQSODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQ
garage.
49-80328 Rev. 4 3
Design Information
CONTENTS
Design Information
3URGXFW'LPHQVLRQVDQG&OHDUDQFHV ............................ 3
Installation Options ........................................................ 3
,QVWDOODWLRQ3UHSDUDWLRQ
$GYDQFH3ODQQLQJ'XFWZRUN)UDPLQJ ......................... 4
3RZHU6XSSO\ ................................................................ 4
'XFW)LWWLQJV .................................................................. 5
Tools and Materials Required ....................................... 6
5HPRYHWKH3DFNDJLQJ ................................................. 6
Determine Installation Height ........................................
:DOO0RXQW,QVWDOODWLRQ+HLJKWV .....................................
Check Installation Hardware ......................................... 8
Installation—Vented to the Outside
'XFWZRUN:LULQJ/RFDWLRQV ...........................................
6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW......................
6WHS,QVWDOO0RXQWLQJ%UDFNHW ................................. 
6WHS,QVWDOO'XFW%UDFNHW ......................................... 
6WHS3UHSDUHWKH+RRG ........................................... 11
6WHS0RXQWWKH+RRG .............................................. 12
6WHS/HYHOWKH+RRG................................................ 12
6WHS&RQQHFW'XFWZRUN .......................................... 12
6WHS&RQQHFW(OHFWULFDO ........................................... 13
6WHS,QVWDOO'XFW&RYHUV.......................................... 14
6WHS,QVWDOO)LOWHUV .................................................. 14
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 14
Installation—Recirculating
'XFWZRUN:LULQJ/RFDWLRQV ......................................... 15
6WHS,QVWDOO)UDPLQJIRU+RRG6XSSRUW.................... 15
6WHS,QVWDOO0RXQWLQJ%UDFNHW ................................. 16
6WHS,QVWDOO'XFW%UDFNHW ......................................... 16
6WHS3UHSDUHWKH+RRG ........................................... 
6WHS0RXQWWKH+RRG .............................................. 
6WHS/HYHOWKH+RRG................................................ 
6WHS6L]HDQG&XW'XFW3LHFH................................. 18
6WHS&RQQHFW(OHFWULFDO ........................................... 18
6WHS,QVWDOO'XFW&RYHUV.......................................... 
6WHS,QVWDOO)LOWHUV .................................................. 
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 
PRODUCT DIMENSIONS AND
CLEARANCES
7KHYHQWKRRGPXVWEHLQVWDOOHG´PLQDQG
PD[DERYHWKHFRRNLQJVXUIDFH7KHKRRGLQVWDOODWLRQ
height above the cooking surface depends upon
ceiling height.
The telescopic duct cover conceals the ductwork
running from the top of the hood to the ceiling. The
VXSSOLHGGXFWFRYHULVVL]HGWRUHDFK¶WR¶´FHLOLQJ
heights.
7KH=;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJ
KHLJKWVRI¶´WR¶´
INSTALLATION OPTIONS
NOTE: Installation height should be measured from
the cooking surface to the outer glass sides.
This hood may be installed onto a wall and vented
WRWKHRXWGRRUVRULWFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ
RSHUDWLRQ$OOQHFHVVDU\SDUWVIRUUHFLUFXODWLQJ
RSHUDWLRQDUHVXSSOLHGZLWKWKHKRRG1RNLWVUHTXLUHG
This hood can be installed over any Monogram
electric cooktop or gas cooktop. It cannot be
LQVWDOOHGRYHUD0RQRJUDP3URIHVVLRQDOFRRNWRS
or range.
*Height
to
Ceiling
7/16"
3 1/4"
35 7/8"
7KH6XSSOLHG'XFW&RYHU)LWVWRCeiling Heights.
)RUWRFHLOLQJVRUGHU=;
*Height
to
Ceiling

´
´
3 1/4”
24” Min.
´0D[
4 49-80328 Rev. 4
Installation Preparation
ADVANCE PLANNING
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOG
QRWH[FHHGIWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configurations.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH
PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
air system in accordance with local building
code requirements. Visit GEAppliances.com for
available makeup air solutions.
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer
XQFRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXH
G¶LQFHQGLHHWSRXYRLUpYDFXHUO¶DLUFRUUHFWHPHQW,O
QHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDV
pYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXU
XQSODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQ
garage.
Ŷ8VHPHWDOGXFWZRUNRQO\7KHVHKRRGVPXVWXVH
8” round duct.
Ŷ,QVWDOODZDOOFDSZLWKGDPSHURUURRIFDSDWWKH
H[WHULRURSHQLQJ2UGHUWKHZDOORUURRIFDSDQGDQ\
transition needed in advance.
Wall Framing for Adequate Support
Ŷ7KLVYHQWKRRGLVKHDY\$GHTXDWHVWUXFWXUDO
support must be provided in all types of
installations. The hood must be secured to vertical
VWXGVLQWKHZDOORUWRDKRUL]RQWDOVXSSRUW
Ŷ7KHYHQWKRRGVKRXOGEHRQVLWHEHIRUHILQDOIUDPLQJ
and wall finishing. This will help to accurately locate
the duct work and electrical service.
Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHG
before the cooktop and countertop are installed.
Decorative Duct Covers
This hood is shipped with a decorative duct cover for
FHLOLQJKHLJKWVRI¶´WR¶´=;GXFWFRYHU
DFFHVVRU\LVDYDLODEOHWRUHDFK¶´WR¶´FHLOLQJ
heights. The accessory should be ordered with the
hood and be on site before installation begins.
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
AVERTISSEMENT
3285'(65$,6216
'(6e&85,7e&(7$33$5(,/'2,7Ç75(
&255(&7(0(170,6¬/$7(55(
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWK
WKLVDSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRU
prevailing local codes and ordinances.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]
DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG
EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJDVFORVHWRWKHLQVWDOODWLRQ
location as possible on the back wall or ceiling.
Ŷ&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil
GHPLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(Q
FDVGHGRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQ
WHFKQLFLHQSRXUGpWHUPLQHUVLO¶DSSDUHLOHVWjODWHUUH
CAUTION
$XWRPDWLFDOO\2SHUDWHG'HYLFH±
To reduce the risk of injury disconnect from power supply
before servicing. This unit is equipped with an integral
disconnecting switch located inside the blower housing.
ATTENTION
$SSDUHLOFRPPDQGp
DXWRPDWLTXHPHQW$ILQGHUpGXLUHOHVULVTXHVGH
EOHVVXUHGpEUDQFKH]O¶DSSDUHLOGHO¶DOLPHQWDWLRQ
pOHFWULTXHDYDQWGHSURFpGHUjXQHUpSDUDWLRQ
/¶DSSDUHLOHVWpTXLSpG¶XQVHFWLRQQHXULQWpJUDOVLWXpj
O¶LQWpULHXUGXORJHPHQWGXYHQWLODWHXU
49-80328 Rev. 4 5
Installation Preparation
DUCT FITTINGS
This Hood Must Use an 8” Round
Duct. It Can Transition to a
3-1/4” x 12” Duct.
8VHWKLVFKDUWWRFRPSXWHPD[LPXPSHUPLVVLEOHOHQJWKV
for duct runs to outdoors.
NOTE:'RQRWH[FHHGPD[LPXPSHUPLVVLEOHHTXLYDOHQW
lengths!
Maximum duct length: 100 foot for range hoods.
Flexible ducting
,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOOWKHHTXLYDOHQWIHHW
YDOXHVLQWKHWDEOHVKRXOGEHGRXEOHG7KHIOH[LEOHPHWDO
GXFWVKRXOGEHVWUDLJKWDQGVPRRWKDQGH[WHQGHGDV
much as possible.
'R127XVHIOH[LEOHSODVWLFGXFWLQJ
NOTE:$Q\KRPHYHQWLODWLRQV\VWHPVXFKDVD
YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUIORZRI
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\ILUHSODFHVJDV
IXUQDFHVJDVZDWHUKHDWHUVDQGRWKHUQDWXUDOO\YHQWHG
systems. To minimize the chance of interruption of such
QDWXUDOO\YHQWHGV\VWHPVIROORZWKHKHDWLQJHTXLSPHQW
manufacturer’s guidelines and safety standards such
DVWKRVHSXEOLVKHGE\1)3$DQG$6+5$(:KHQ
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
Duct Piece Dimensions
Equivalent
Length*
Quantity
Used
Total
Equivalent
Length
5RXQG
straight
1 ft. (per foot
length)
´[´
straight
1 ft. (per foot
length)
HOERZ IW
HOERZ IW
´[´
HOERZ
43 ft.
´[´
HOERZ
26 ft.
´[´
IODW
elbow
IW
8” round to
´[´
transition
2 ft.
´[´
to 8” round
transition
5 ft.
8” round to
´[´
WUDQVLWLRQ
elbow
6 ft.
´[´
to 8” round
WUDQVLWLRQ
elbow
13 ft.
Round wall
cap with
damper
32 ft.
´[´
wall cap with
damper
IW
Round roof
cap
44 ft.
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJ
equivalent. Equivalent length of duct pieces
DUHEDVHGRQDFWXDOWHVWVFRQGXFWHGE\*(
$SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFW
requirements for good venting performance
with any ventilation hood.
Total Duct Run
6 49-80328 Rev. 4
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Ŷ Tape measure
Ŷ Knife
Ŷ Spirit level
Ŷ:LUHFXWWHUVWULSSHU
Ŷ:LUHQXWV
Ŷ Electric drill with 5/16” and 3/8” bits
Ŷ3KLOOLSVDQGIODWEODGHVFUHZGULYHUV
Ŷ Hammer
Ŷ3OLHUV
Ŷ Safety glasses
Ŷ Duct tape
Ŷ Tape to mount template
Ŷ*ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV
Ŷ9+]RU$PSZLUHZLWK
JURXQG3URSHUO\JURXQGHGEUDQFKFLUFXLW
Ŷ Strain relief for junction cover
Ŷ´URXQGPHWDOGXFWOHQJWKWRVXLW
installation
Ŷ6DZMLJVDZRUUHFLSURFDWLQJVDZ
*ORYHV
Knife
:LUHFXWWHU
stripper
)ODWEODGH
screwdriver
Hammer
URXQGPHWDO
GXFWOHQJWKWRVXLW
installation
Measuring tape
Electric drill
with 5/16”
and 3/8” Bits
12” long
3KLOOLSV
head
screwdriver
Safety glasses
Spirit level
3OLHUV
Duct tape
Masking tape
:LUHQXWV
Strain relief
6DZMLJVDZRU
reciprocating
saw
REMOVE THE PACKAGING
CAUTION
/,)77+(+22'2872)7+(%2;
%<7+(&(17(50(7$/3257,21'2127/,)7%<
7+(*/$666,'(6
ATTENTION
/(9(=/$+277(¬/¶(;7e5,(85
'(/$%2Ì7(3$5/$3257,210e7$/&(175$/
1(/(9(=3$63$5/(6&Ð7e6'(9(55(
CAUTION
:HDUJORYHVWRSURWHFWDJDLQVW
sharp edges.
ATTENTION
3RUWH]GHVJDQWVSRXUpYLWHUOHV
EOHVVXUHVFDXVpHVSDUOHVWUDQFKDQWV
Ŷ*UDVSWKHKRRGE\WKHPHWDOLQVHUWLQWKHFHQWHUDQG
OLIWVWUDLJKWXSDQGRXWRIWKHER[
Ŷ5HPRYHDQGSURSHUO\GLVFDUGWKHSODVWLFZUDSSLQJ
Ŷ5HPRYHSDUWVER[GXFWFRYHUVDQGRWKHUSDFNDJLQJ
49-80328 Rev. 4
Installation Preparation
DETERMINE INSTALLATION HEIGHT
Ŷ7HOHVFRSLFGXFWFRYHUVDUHSURYLGHGWRFRQFHDO
the ductwork running to the ceiling.
Ŷ7KLVKRRGFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ
RSHUDWLRQ1RNLWVUHTXLUHG
7KHYHQWKRRGPXVWEHLQVWDOOHG´PLQDQG´
PD[DERYHWKHFRRNLQJVXUIDFH7KHKRRGLQVWDOODWLRQ
KHLJKWIURPWKHFRRNLQJVXUIDFHWRWKHERWWRPRIWKH
KRRGGHSHQGVXSRQFHLOLQJKHLJKW
ACCESSORIES:
Ŷ2UGHU=;DFFHVVRU\IRU=9ZDOOPRXQW
KRRGWRUHDFKFHLOLQJKHLJKWVEHWZHHQ¶´DQG
¶´7KLVDFFHVVRU\FRQWDLQVRQH´ORQJGXFW
cover.
24” Min.
´0D[
36” Min.
NOTE: Measure
installation height from
the cooking surface to
the outer glass portion of
the hood.
Wall Mount ZV900
Installation Heights
Actual Ceiling
Height
*Possible VENTED
Installation Height
*Possible
RECIRCULATING
Installation Height
¶´ 24” to 26” 24” to 26”
¶´ ´WR´ ´WR´
8’-1” 24” to 28” 24” to 28”
8’-2” ´WR´ ´WR´
8’-3” ´WR´ ´WR´
8’-4” ´WR´ ´WR´
8’-5” ´WR´ ´WR´
8’-6” ´WR´ ´WR´
¶´ ´WR´ ´WR´
8’-8” ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
8’-11” ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ 24”WR´ ´WR´
¶´ ´WR´ ´WR
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
¶´ ´WR´ ´WR´
*Based on 36” countertop height.
SUPPLIEDACCESSORY ZX90010
8 49-80328 Rev. 4
Installation Preparation
CHECK INSTALLATION HARDWARE
/RFDWHWKHKDUGZDUHDFFHVVRU\ER[SDFNHGZLWKWKHKRRGDQGFKHFNFRQWHQWV
2
9-7/8"
11-1/2"
12"
27-3/4"
Mounting bracket
1 charcoal filter for
recirculating installation
2-piece decorative duct
cover (dimension shown
for reference only)
$LUGHIOHFWRU
for recirculating
installation only
Duct bracket
14-5/8≤
to top of
bracket
C
L
t
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICA TING BOTT OM
OF THE HOOD
Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support
REAR WALL
MOUNTING TEMPLA TE
49-80405 04-06 JR
:DOOPRXQWWHPSODWH
+$5':$5(
3$&.$*(
Locate and count
screws
3 wood
screws
3 wall
fasteners
3 wall bracket
screws
12 hood
attachment
screws
´
´
´
11-1/2”
Stainless steel filter
2 thumb
screws
49-80328 Rev. 4
Installation Instructions
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
±0HDVXUH´IURPWKHIORRUWRWKHWRSRIWKH
FRRNLQJVXUIDFH$GGKRRGLQVWDOODWLRQKHLJKW
GHWHUPLQHGRQSDJH0DUNWKDWORFDWLRQ
±8VHDOHYHOWRGUDZDVWUDLJKWSHQFLOOLQHRQWKH
wall.
±7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKH
penciled line. CHECK TO BE SURE THE
7(03/$7(,6/(9(/
Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
Ŷ0HDVXUH´IURPWKHEDFNZDOOWRWKHFHQWHUOLQH
of an 8-1/2” hole on the ceiling.
NOTE:,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOOWKLFNQHVV
to the 5-1/2” dimension.
Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template.
Ŷ0HDVXUHDWOHDVW´DERYHWKHSHQFLOOLQHWKDW
LQGLFDWHVWKHERWWRPLQVWDOODWLRQKHLJKWWRWKH
centerline of an 8-1/2” dia. duct hole. (Hole may be
elongated for duct elbow.)
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOODWOHDVW´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHOHIWVLGH
of the centerline.
5-1/2” c enterline to wall
8-1/2” dia. hole
)25&(,/,1*9(17'8&7,1*
Centerline 26” above the
marked bottom pencil line
for installation height.
)25:$//9(17'8&7
Ceiling
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT )UDPLQJPXVWEHFDSDEOHRI
VXSSRUWLQJOEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the bottom mounting bracket
installation location. The horizontal support must
be flush with the room side of the studs. Use cleats
behind both sides of the support to secure to wall
studs.
Ŷ5HLQVWDOOGU\ZDOO
Centerline of
installation
space
View from
rear cleats
´[´PLQ
mounting
support
8-1/2” min. opening for ductwork
INSTALLATION—VENTED TO THE OUTSIDE
 49-80328 Rev. 4
Installation Instructions
2
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
Ŷ:LWKWKHWHPSODWHWDSHGLQSODFHXVHDSXQFKWR
mark mounting bracket screw locations.
Ŷ'ULOO´SLORWKROHVLQRIWKHSXQFKHGORFDWLRQV
in the lower bracket.
Ŷ5HPRYHWKHWHPSODWH
Ŷ8VHZRRGVFUHZVWRVHFXUHWKHPRXQWLQJEUDFNHWWR
the wall. The screws must engage wall studs or the
installed horizontal mounting support.
Ŷ&KHFNWREHVXUHWKDWWKHEUDFNHWLVOHYHO
3
INSTALL DUCT BRACKET
The duct bracket should be installed against the back
wall and flush with the ceiling. This bracket will hold
the duct cover in place at the top.
Secure the bracket to the wall:
Ŷ$OLJQWKHPDUNHGFHQWHUOLQHRQWKHEUDFNHWZLWKWKH
centerline on the wall.
Ŷ0DUNVFUHZKROHORFDWLRQVLQWKHZDOO
Ŷ'ULOO´SLORWKROHVLQWKHPDUNHGORFDWLRQV
Ŷ,ISLORWKROHVGRQRWHQWHUVWXGVHQODUJHWKHKROHV
to 3/8” and install wall fastener anchors.
Ŷ'ULYHVFUHZVE\KDQGLQWRWKHIDVWHQHUVWRDOORZ
DQFKRUVWRH[SDQG5HPRYHWKHVFUHZV
Ŷ6HFXUHWKHEUDFNHWWRWKHZDOOZLWKZRRGVFUHZV
and/or fasteners.
14-5/8≤
to top of
bracket
C
L
t
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICA TING BOTT OM
OF THE HOOD
Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support
REAR WALL
MOUNTING TEMPLA TE
49-80405 04-06 JR
INSTALLATION—VENTED TO THE OUTSIDE
49-80328 Rev. 4 11
Installation Instructions
4
PREPARE THE HOOD
Ŷ3ODFHWKHKRRGRQDSDGGHGVXUIDFH
Ŷ3RVLWLRQWKHPRWRUKRXVLQJDWWKHEDFNRIWKHKRRG
(OHFWULFDOFRQQHFWRUVVKRXOGIDFHWKHIURQWZLWKUHDU
mounting hooks at the back.
Ŷ6OLSWKHERWWRPIODQJHRIWKHPRWRUKRXVLQJLQWRWKH
side slots at the top rear opening.
Ŷ
Carefully lay the hood on its back.
Ŷ)DVWHQWKHKRRGWRWKHPRWRUKRXVLQJIURPWKHERWWRP
using 6 screws.
Ŷ-RLQWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKHKRRG
Rear
mounting
hooks
Engage flange on
motor housing into
slots
Rear view
Bottom view
Rear side
)URQWVLGH
To Lights
To
Control
3DQHO
INSTALLATION—VENTED TO THE OUTSIDE
12 49-80328 Rev. 4
Installation Instructions
5
MOUNT THE HOOD
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGRQWRWKHPRXQWLQJEUDFNHW
Ŷ3RVLWLRQDVSLULWOHYHODWWKHERWWRPRIWKHKRRGWR
check side to side leveling.
7
CONNECT DUCTWORK
Ŷ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQWKHGLUHFWLRQ
of airflow as illustrated.
Ŷ3XVKGXFWRYHUWKHH[KDXVWRXWOHWDQGGDPSHU
Ŷ6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
Ŷ:UDSDOOGXFWMRLQWVDQGWKHIODQJHFRQQHFWLRQVZLWK
duct tape for an airtight seal.
CAUTION
Do not use sheet metal screws at the
hood flange connection. Doing so will prevent proper
damper operation. Seal connection with tape only.
ATTENTION
Il ne faut pas utiliser de vis
DXWRUDXUGHXVHVjODFRQQH[LRQGXFROOHWGHOD
hotte. Ceci empêcherait le bon fonctionnement du
UHJLVWUH1¶XWLOLVHUTXHGXUXEDQDGKpVLISRXUDVVXUHU
O¶pWDQFKpLWpGXUDFFRUG
6
LEVEL THE HOOD
This hood has built-in levelers on the mounting hooks
DWHDFKVLGH8VHDORQJ3KLOOLSVVFUHZGULYHUIURPWKH
front to access the levelers.
Ŷ8VHWKHWRSVFUHZKROHLQWKHOHYHOHUWRUDLVHRU
lower the hood on that side.
Ŷ8VHWKHERWWRPVFUHZKROHWRSXOOWKHKRRGWLJKW
against the wall surface.
Ŷ0DUNKROHORFDWLRQDWWKHERWWRPRIWKHKRRG
Ŷ5HPRYHWKHKRRG,IWKHERWWRPVFUHZKROHGRHV
QRWHQWHUDVWXGHQODUJHWKHKROHWR´DQGLQVWDOO
wall fastener anchors.
Ŷ3ODFHWKHKRRGEDFNRQWRWKHPRXQWLQJEUDFNHW
check level again and install the wall fastener.
Levelers
Screw hole
Duct tape
over seam
and screw
Screw
$LUIORZ
INSTALLATION—VENTED TO THE OUTSIDE
49-80328 Rev. 4 13
Installation Instructions
8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with a
JURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKHLQVWDOOHU
:KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWRXVH8/
DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR
copper connectors.
AVERTISSEMENT
Si le câblage de la maison n’est
SDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUHO¶LQVWDOODWHXU
GRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHVILOVGHOD
PDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQG¶XWLOLVHUGHOD
SkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQQHFWHXUV
pour l’aluminium-cuivre.
Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXWRQWKH
left side.
Ŷ6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWK
a strain relief.
Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU
Be sure wires are not pinched.
Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ
Knockout
-%R[FRYHU
House wiring
-%R[FRYHU
INSTALLATION—VENTED TO THE OUTSIDE
14 49-80328 Rev. 4
Installation Instructions
9
INSTALL DUCT COVERS
Ŷ3ODFHWKHGHFRUDWLYHGXFW
covers on top of the hood.
NOTE: The inside (upper) duct
piece has holes on one end.
The holes are intended for use
when the hood is installed for
recirculating purposes. Slide the
inside end into the outer piece;
the vent holes should not be
visible in this installation.
The inside duct piece must slip into the folded ends of
the outer section.
Ŷ([WHQGWKHLQQHUGXFWXSZDUGWRWKHFHLOLQJEUDFNHW
Ŷ6HFXUHGXFWFRYHUWRFHLOLQJEUDFNHWZLWKVFUHZV
10
INSTALL FILTERS
IMPORTANT: &KHFNWREHVXUHWKDWWKHPDLQ21
2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ
Ŷ5HPRYHSURWHFWLYHILOPRQWKHILOWHUV
Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKHRSHQLQJ
Lift the filter to the opposite side and into the filter
lock.
Ŷ7RUHPRYHWKHILOWHUSXOOWKHILOWHUORFNGRZQZDUG
11
FINALIZE INSTALLATION
Ŷ&KHFNWREHVXUHDOOWDSHDQGSDFNDJLQJPDWHULDOV
have been removed.
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
Mounting
screws
Duct cover support
bracket
Upper
duct cover
Lower duct
cover seat
Duct cover
support bracket
Lower duct
cover
)LOWHU/RFN
INSTALLATION—VENTED TO THE OUTSIDE
49-80328 Rev. 4 15
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
Ŷ0HDVXUH´IURPWKHIORRUWRWKHWRSRIWKHFRRNLQJ
VXUIDFH$GGKRRGLQVWDOODWLRQKHLJKWGHWHUPLQHGRQ
SDJH0DUNWKDWORFDWLRQ
Ŷ8VHDOHYHOWRGUDZDVWUDLJKWSHQFLOOLQHRQWKHZDOO
Ŷ7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKHSHQFLOHG
OLQH&+(&.72%(685(7+(7(03/$7(,6
LEVEL.
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOODWOHDVW´
DERYHWKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKH
centerline.
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT )UDPLQJPXVWEHFDSDEOHRI
VXSSRUWLQJOEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the bottom mounting bracket
installation location. The horizontal support must
be flush with the room side of the studs. Use cleats
behind both sides of the support to secure to wall
studs.
Ŷ5HLQVWDOOGU\ZDOO
Centerline of
installation
space
View from
rear cleats
´[´PLQ
mounting
support
Installation Instructions
Ceiling
INSTALLATION—RECIRCULATING
16 49-80328 Rev. 4
2
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
Ŷ:LWKWKHWHPSODWHWDSHGLQSODFHXVHDSXQFKWR
mark mounting bracket screw locations.
Ŷ'ULOO´SLORWKROHVLQRIWKHSXQFKHGORFDWLRQV
in the lower bracket.
Ŷ5HPRYHWKHWHPSODWH
Ŷ8VHZRRGVFUHZVWRVHFXUHWKHPRXQWLQJEUDFNHWWR
the wall. The screws must engage wall studs or the
installed horizontal mounting support.
Ŷ&KHFNWREHVXUHWKDWWKHEUDFNHWLVOHYHO
3
INSTALL DUCT BRACKET
The duct bracket should be installed against the back
wall and flush with the ceiling. This bracket will hold
the duct cover in place at the top.
Secure the bracket to the wall:
Ŷ$OLJQWKHPDUNHGFHQWHUOLQHRQWKHEUDFNHWZLWKWKH
centerline on the wall.
Ŷ0DUNVFUHZKROHORFDWLRQVLQWKHZDOO
Ŷ'ULOO´SLORWKROHVLQWKHPDUNHGORFDWLRQV
Ŷ,ISLORWKROHVGRQRWHQWHUVWXGVHQODUJHWKHKROHV
to 3/8” and install wall fastener anchors.
Ŷ'ULYHVFUHZVE\KDQGLQWRWKHIDVWHQHUVWRDOORZ
DQFKRUVWRH[SDQG5HPRYHWKHVFUHZV
Ŷ6HFXUHWKHEUDFNHWWRWKHZDOOZLWKZRRGVFUHZV
and/or fasteners.
14-5/8≤
to top of
bracket
C
L
t
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICA TING BOTT OM
OF THE HOOD
Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support
REAR WALL
MOUNTING TEMPLA TE
49-80405 04-06 JR
Installation Instructions
INSTALLATION—RECIRCULATING
49-80328 Rev. 4 
Installation Instructions
INSTALLATION—RECIRCULATING
4
PREPARE THE HOOD
Ŷ3ODFHWKHKRRGRQDSDGGHGVXUIDFH
Ŷ3RVLWLRQWKHPRWRUKRXVLQJDWWKHEDFNRIWKHKRRG
(OHFWULFDOFRQQHFWRUVVKRXOGIDFHWKHIURQWZLWKUHDU
mounting hooks at the back.
Ŷ6OLSWKHERWWRPIODQJHRIWKHPRWRUKRXVLQJLQWRWKH
side slots at the top rear opening.
Ŷ&DUHIXOO\OD\WKHKRRGRQLWVEDFN
Ŷ)DVWHQWKHKRRGWRWKHPRWRUKRXVLQJIURPWKH
ERWWRPXVLQJVFUHZV
Ŷ-RLQWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKHKRRG
Rear
mounting
hooks
Engage flange on
motor housing into slots
Rear view
Bottom view
Rear side
)URQWVLGH
To Lights
To
Control
3DQHO
5
MOUNT THE HOOD
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGRQWRWKHPRXQWLQJEUDFNHW
Ŷ3RVLWLRQDVSLULWOHYHODWWKHERWWRPRIWKHKRRGWR
check side to side leveling.
6
LEVEL THE HOOD
This hood has built-in levelers on the mounting hooks
DWHDFKVLGH8VHDORQJ3KLOOLSVVFUHZGULYHUIURPWKH
front to access the levelers.
Ŷ8VHWKHWRSVFUHZKROHLQWKHOHYHOHUWRUDLVHRU
lower the hood on that side.
Ŷ8VHWKHERWWRPVFUHZKROHWRSXOOWKHKRRGWLJKW
against the wall surface.
Ŷ0DUNKROHORFDWLRQDWWKHERWWRPRIWKHKRRG
Ŷ5HPRYHWKHKRRG,IWKHERWWRPVFUHZKROHGRHV
QRWHQWHUDVWXGHQODUJHWKHKROHWR´DQGLQVWDOO
wall fastener anchors.
Ŷ3ODFHWKHKRRGEDFNRQWRWKHPRXQWLQJEUDFNHW
check level again and install the wall fastener.
Levelers
Screw hole
18 49-80328 Rev. 4
Installation Instructions
INSTALLATION—RECIRCULATING
7
SIZE AND CUT DUCT PIECE
Ŷ+ROGXSSHUDLUGHIOHFWRUZLWKGXFWFRQQHFWRUDJDLQVW
the ceiling.
Ŷ0HDVXUHIURPWKHERWWRPRIWKHDLUGHIOHFWRUWRWKH
top of the hood as shown. Reduce that dimension
by 1” to facilitate installation. The duct will cover and
overlap the deflector and the hood outlets.
Ŷ&XWWKHGXFWSLHFHWRVL]HDQGVOLS
onto the bottom of the deflector.
Ŷ3ODFHWKHDVVHPEOHGGHIOHFWRU
DQGGXFWRYHUWKHH[KDXVWRXWOHW
Ŷ+ROGWKHDVVHPEO\DJDLQVWWKH
duct bracket.
Ŷ'ULYHVFUHZVLQWRWKHERWWRPRI
the deflector and into the bracket.
Ŷ8VHGXFWWDSHWRVHDOGXFWWR
WKHGHIOHFWRUDQGDWWKHH[KDXVW
outlet.
Measure
length
Duct
length
Deflector
8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH
LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH
WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG
aluminum-to-copper connectors.
AVERTISSEMENT
Si le câblage de la maison
Q¶HVWSDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUH
O¶LQVWDOODWHXUGRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHV
ILOVGHODPDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQ
G¶XWLOLVHUGHODSkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HW
des connecteurs pour l’aluminium-cuivre.
Ŷ5HPRYH
MXQFWLRQER[
cover and
knockout on
the left side.
Ŷ6HFXUHWKH
house wiring
to the junction
ER[ZLWKD
strain relief.
Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%H
sure wires are not pinched.
Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ
Knockout
-%R[FRYHU
House wiring
-%R[FRYHU
49-80328 Rev. 4 
9
INSTALL DUCT COVERS
Ŷ3ODFHWKHGHFRUDWLYHGXFW
covers on top of the hood.
NOTE: The inside piece has
holes on one end intended for
use when the hood is installed for
recirculating purposes. Be sure
the vented end is at the top; the
vent holes will be visible in this
installation.
The inside duct piece must slip
into the folded ends of the outer
section.
Ŷ([WHQGWKHLQQHUGXFWXSZDUGWRWKHFHLOLQJEUDFNHW
Ŷ6HFXUHGXFWFRYHUWRFHLOLQJEUDFNHWZLWKVFUHZV
10
INSTALL FILTERS
IMPORTANT: &KHFNWREHVXUHWKDWWKHPDLQ21
2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ
Charcoal filter
Ŷ,QVWDOOWKHEODFNFKDUFRDOILOWHULQWRWKHFHQWHU
opening. Secure the filter with thumbscrews on
each side.
Metal filter
Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKHRSHQLQJ
Lift the filter to the opposite side and into the filter
lock.
11
FINALIZE INSTALLATION
Ŷ5HPRYHDOOWDSHDQGSDFNLQJPDWHULDO
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
Installation Instructions
INSTALLATION—RECIRCULATING
Mounting
screw holes
Vent holes
Duct cover support
bracket
Upper
duct cover
Lower
duct cover
Lower duct
cover seat
Duct cover
support bracket
)LOWHU/RFN
NOTE::KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN
safety glasses or goggles should be worn.
)RU0RQRJUDP
®
ORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
NOTE:3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW
0RQRJUDP$SSOLDQFHV7KHUHIRUHPDWHULDOVDSSHDUDQFH
and specifications are subject to change without notice.
49-80328 Rev. 4
10-19 GEA
Printed in Mexico
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

GE ZV900SLSS Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI