Gianni WLP-100 User manual

Category
Security device components
Type
User manual

Gianni WLP-100 is a wireless power transfer system designed to power electronic locks on doors without the need for physical wires. It features inductive coupling technology to transmit power across a small air gap between the door and the frame. The system includes a transmitter unit mounted on the frame and a receiver unit mounted on the door. The transmitter unit draws power from a 27.6 VDC power supply and can provide up to 12 or 24 VDC to the receiver unit, depending on the jumper setting.

Gianni WLP-100 is a wireless power transfer system designed to power electronic locks on doors without the need for physical wires. It features inductive coupling technology to transmit power across a small air gap between the door and the frame. The system includes a transmitter unit mounted on the frame and a receiver unit mounted on the door. The transmitter unit draws power from a 27.6 VDC power supply and can provide up to 12 or 24 VDC to the receiver unit, depending on the jumper setting.

Inductive Coupling
Power Transfer
Receiver Transmitter
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13
1
IR Transmitter
25
115
33.5
3
140
156
Unit: mm
Current Draw
Lock Status Output
Door Status Output
Output Power
Current Draw
Lock Status Input
Infrared Sensing
Door Opening Time
Maximum Door Gap
Maximum Tolerance
Operating Temperature
Humidity
WLP-100 Wireless Power Transfer
Installation Instruction
Input Power
Specifications
Transmitter on Frame Side
27.6 VDC
1A/27.6VDC
Relay (Dry contacts: N.O./N.C./Com.)
Rating: 1A/ 30VDC
Receiver on Door Side
with 3/16" (4~5mm)
Door Gap
12/24 VDC
800mA/12VDC
400mA/24VDC
Dry contacts: N.O./Com.
Transmitter Receiver
15 / 30 seconds
*For fail-secure locks only
3/16” (4~5mm)
Horizontal alignment : 1/16" (1mm)
Vertical alignment : 1/16" (1mm)
IR Sensing: 1/16” (1mm)
32° to +120.2°F ( 0° to +49°C )
0 to 85% Non-condensing
Unit
Unit
Reed Switch
(Dry contacts: N.O./N.C./Com.)
Rating: 0.1A/ 20VDC
*Requires 1.5 A power when energized
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13 2
1. Door & Frame Inspection
Installation Steps
Installation &Wiring
Included in Package
Door Side Unit Frame Side Unit Door Side Template Frame Side Template
Wood Screws Metal Screws Mounting Tabs
Note: For optimal performance, it is recommended to minimize the door gap and use the supplied
templates. The WLP-100 allows for some horizontal and vertical misalignment. Tolerance for
minor misalignment will increase as door gap decreases.
After checking the door and frame conditions, apply the templates at the appropriate location.
The WLP-100 can be installed on the latch side, hinge side, or top of the door.
Washers
1a. Apply the door side template. 1b. Apply the frame side template. Make sure to
align the horizontal and vertical centerlines.
Align the centerline
on the template.
2. Metal Door Installation
2a. Center punch the screw locations for mounting
tabs and counter-sink for M5 screw.
2b. Cut out the main body on the door.
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13 3
3c. Use the chisel to straighten the sides. 3d. Check if the WLP-100 ts well in the cutout
and use the le if necessary.
2c. Check if the WLP-100 ts well in the cutout and
use the le if necessary.
2d. Install mounting tabs using M5 screws.
3. Wood Door Installation
3a. Drill two 1" (25mm) diameter holes,
1/8" (3mm) in depth as shown on the
template.
3b. Drill and cut the WLP-100 main body to a
minimum depth of 1-9/16” (40mm), and
diameter of 1" (25mm) on the door side.
12 or 24VDC
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13 4
24VDC
INPUT
Transmitter
Unit
12VDC
OUTPUT
24VDC
Receiver
Unit
27.6VDC / 1.5Amp
OUTPUT
12VDC
24VDC
Receiver
Unit
12VDC 24VDC
Ground
3e. For the door side unit, drill a wiring
channel to the electried device to
be powered.
4. Selecting the Lock Output Voltage
Use the jumper on the back of the door side
unit to select the appropriate lock voltage.
Jumper Setting
5. Frame Installation
For the frame side unit, repeat steps 2 or 3 to install on a metal or wood frame.
Wiring Instructions
Please refer to the wiring diagrams on page 5, 6.
WLP-100 Pigtail Wire Color Function
Frame
Door Leaf
Input Power
Reed Switch
Relay Output
(Lock Status)
Lock Status
Input
Lock Power
Output
Red (+)
Black (-)
Red
Black
White
Yellow
Blue
Green
Blue
Green
Red (+)
Black (-)
(select through jumper
setting)
(Transmitter)
(Receiver)
N.C.
COM.
COM.
N.O.
N.C.
COM.
N.O.
N.O.
WLP-100 Wiring Diagram (1)
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13 5
27.6VDC / 1.5Amp
POWER
SUPPLY
Jumper
12VDC
12VDC
24VDC
INPUT OUTPUT
RED(+)
BLK(-)
YEL (N/C)
GRN (COM)
BLU (N/O)
RED(+)
BLK (-)
GRN (COM)
BLU (N/O)
12V (+)
12V (-) max 12VDC
@800mA
Receiver
Unit
Transmitter
Unit
Door Status Output
RED (N/C)
BLK (COM)
WHT (N/O)
Power Input
Lock Status Output Power Output
Lock Status Input
Fail-Secure
Electric Lock
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13 6
27.6VDC / 1.5Amp
12VDC 24VDC
GML-800 (Lock)
Fail-Secure Mode
IN+
IN -
N.O.1
COM.1
N.C.1
PB
PB
REED
REED
N.O.2
COM.2
N.C.2
COM. N.O.
COM.
N.O.
COM.
N.O.
COM.
N.O.
N.C.
COM.
N.O.
N.C.
POWER
SUPPLY
DG-15LD
TLM-300S
WLP-100 Wiring Diagram (2)
Lock Status LED Indicator
Door Status Output:
N.O. contact when door close
N.C. contact when door open
Anti-tailgating function for Relay 2 only
Jumper Setting
Digital Keypads
Problem
No power
Installation position
is incorrect
SolutionPossible Cause
Unable to
unlock
No sensor
output
No door status
output
No lock status
output
Check that the power supply is connected and works properly
Make sure access control relay contact is wired correctly (N.O.)
Check jumper settings are correct
Check door opening time is not too long (the interval time is 30 seconds)
Check installation position/alignment is correct
Check door gap does not exceed maximum recommended distance
(Package including washers for minimizing gap)
Check installation position/alignment is correct
Check installation position/alignment is correct
Make sure lock status wires are connected to wireless power source
Insucient
power output
Transmitter
Unit
Receiver
Unit
(Transmitter)
(Both)
(Both)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Gianni WLP-100 User manual

Category
Security device components
Type
User manual

Gianni WLP-100 is a wireless power transfer system designed to power electronic locks on doors without the need for physical wires. It features inductive coupling technology to transmit power across a small air gap between the door and the frame. The system includes a transmitter unit mounted on the frame and a receiver unit mounted on the door. The transmitter unit draws power from a 27.6 VDC power supply and can provide up to 12 or 24 VDC to the receiver unit, depending on the jumper setting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI