Mercury 310 / SolarBOX / TITAN 912L
Quick Start Installation Guide
22 support.hysecurity.com
6 foot min.
from pivot
install
12V Solar Panel
12V
BlueBUS
Photo Eye
Open
Limit Open
Limit
Close
Limit
8
6
15
14
14 14
11
1
2
6
Fig-2: Titan 912L Dual-Gate System (Pull-To-Open Shown)
Fig-3: Mercury 310 Controller Features
11
12
15
14
13
controller. See power inputs in
image below. safety devices. See controller accessory in-
puts in the image below.
Attach warning signs to
gate(s).
Connect battery and
solar panels to Mercury Connect other accessories, such as
loop detectors, photo eyes, or other
Perform Gate Limit Learn procedure
(below right).
12
N.O.
+V
+V
+V
+V
N.O.
N.O.
N.O.
N.O.
N.O.
N.C.
COM
COM
COM
COM
N.O.
COM
N.O.
COM
10K
Safety
Sensors
Loop Detectors
BlueBUS
+12 VDC
+12 VDC
(OFF in Standby)
+12 VDC
Guard
Station
Controls
(Step-By-Step)
Remote
Input
Fire Dept.
(Emergency
Access)
Control
N.O.
Control
Control
LOOP 1
(Obstruct)
LOOP 2
(Shadow)
LOOP 3
(Exit)
18-24V DC/
12V Solar 12V
Battery
Actuator Motor Connections
+
+_
_
+12 VDC
(OFF in Standby)
COM
Step Button
Open Button
Latch Button
Fail Safe Button
(On/Off)
Battery Health LED
Alarm
Battery Fuse
(30A)
DC/Solar Fuse (15A)
Battery Power
Indicator LED
DC/Solar Power
Indicator LED
OXI Radio Port
Radio Program:
Arrow Buttons
Left & Right
Function
Knob
Firmware
Update (Motor 1/Motor 2)
(Open, Close, Stop/Clear)
Gate Control Buttons
Open/Close Limit LEDs
Mercury 310 Power Outputs
Location Voltage Amps Standby Mode
INPUTS
12VDC 500 mA
On
SENSORS
LOOPS On
OUTPUTS
R
U
N
L
E
A
F
D
E
L
A
Y
C
L
O
S
E
T
I
M
E
R
L
R
N
M
O
T
O
R
1
F
O
R
C
E
L
R
N
M
O
T
O
R
2
Mercury 310 Power Requirements
> Battery = 12VDC sealed lead acid
> Solar panel = 12V (17-20V MPP)
> DC input = 18-24V high current
CAUTION! Do
not mount the
control box where
the person using
the push button
on box can come
in contact with the
gate!
!
9
button on remote control, then
within 2 seconds press & release
the STEP, OPEN, or LATCH button
on Mercury controller. LED ashes
twice & alarm chirps to indicate
progamming success.
To program the OXI
receiver, press/hold
desired
Gate Limit Learn Procedure:
1. Set function knob to LRN MOTOR 1
(display ashes L1).
2. Use Left/Right buttons to “jog” gate
to between open and close limits.
3. Press/hold both left and right but-
tons for two (2) seconds.
4. Display will show solid L1 and gate
will run at crawl speed to rst limit.
5. After reaching rst limit, display
ashes between OP and CL (LEDs
also ash).
6. Observe current position of the gate
and do only one of the following:
’If gate is at open limit, press the
open button.
’If gate is at close limit, press the
close button.
7. Gate auto-runs to 2nd limit at crawl
speed & stops, then runs to 1st limit
at normal speed & stops, then runs
to the 2nd limit at normal speed &
stops.
8. When finished, display will show
either OP or CL, depending on
buttons pressed during procedure.
9. If dual gate, set function knob to
LEARN MOTOR 2 (display ashes
L2) & repeat all steps for 2nd motor.
7 13
7
13
7
13
Actuator Cable
LEGEND
BlueBUS Wiring
Loop Wiring
Solar Panel Wiring
3
5
4
Conduit for BlueBUS
and 2nd actuator cable
10