HySecurity ACBOX Quick start guide

Category
Gate Opener
Type
Quick start guide
Mercury 310 / ACBOX / TITAN 912L
Quick Start Installation Guide
11
MX5136-01 Rev. A ©2021
78
9
mechanical limits by
manually pushing gate
to desired close limit,
then to desired open
limit, then to halfway
position. Close release,
but do not lock.
feet away from pivot arm (See Fig-2).
With actuator re-
lease open, set Mount Control Box same side as
primary actuator and minimum six
Remove power supply cover &
run AC Cable into ACBox bottom.
Wire to power supply: Green = Earth,
Ground, Black = Hot, White = Neutral.
See Fig-3 on next page.
GATE
912L Actuator
Ensure
Level
Pivot Arm
2
Attach Actuator
to Pivot Arm
Attach Gate Bracket
to Actuator Arm
1/2”x 3.5” Bolt
Pivot Arm
Actuator
Lock Nut
2
1st Washer
Gate Bracket
Install actuator
to pivot arm
with bolt and
lock nut as
shown.
Gate
Bracket
Lock Nut
2nd Washer
3
Install gate bracket to
actuator arm, as shown
(w/ x2 washers, bolt, lock
nut). Do not attach brack-
et to gate until Step 5.
Actuator Arm
Weld or clamp pivot arm onto hinge post. For Pull-to-Open installation, use Detail A. For Push-to-Open, use Detail B:
Actuator And Control Box Installation (perform ALL steps in numerical order):
FRONT VIEW FRONT VIEW
IMPORTANT!
Read entire
manual before
attempting the
installation.
This is NOT a
“do-it-yourself”
project. Use
a qualied
contractor
to install this
system. Read
all safety
information!
1
Gate Bracket
Centerline
Top of
Pivot Arm
1/2”
Pivot
Arm
Hinge
Post
Gate
Gate Bracket
Centerline
Top of
Pivot Arm
1/2”
Pivot
Arm
Hinge
Post
Gate
Or
11
PIVOT ARM
Hinge
Post
Hinge Gate
6”
6”
13”
PIVOT ARM
Hinge
Post
Hinge Gate
Fig-1: Pivot Arm, Actuator, & Gate Bracket Install
TOP VIEW TOP VIEW
A B
CAUTION! Do NOT weld while control board is powered!
1/2”x 2-7/8”Bolt
PULL PUSH
Closed
Closed
Ax Gate
Bracket to
gate struc-
tural support
by welding or
using bolt &
nut.
5
10
Pass cable through
rubber grommets in
bottom of control box
and wire per diagram
at right.
For dual gate install, dig
trench across drive and
run 2nd actuator cable
through conduit.
Open mechanical release on actuator.
2 31
6
Wire TITAN 912L
to control board:
CAUTION! Do not mount the control box where the person
using the push button on box can come in contact with the gate!
4
Pull-To-Open:
Fully open gate,
then locate bracket
on gate support.
Push-To-Open:
Fully close gate, then
locate bracket on
gate support.
Ensure actuator arm is fully retracted, then position gate
bracket on gate structural support per Detail A or Detail B:
Gate Closed
Gate Open
Wall
Wall
B
A
Push-To-Open
Pull-to-Open
Bracket
Bracket
Pull-To-Open
Push-To-Open
Mercury 310 / ACBOX / TITAN 912L
Quick Start Installation Guide
22 support.hysecurity.com
CAUTION!
AC POWER
Fig-2: Titan 912L Dual-Gate System (Pull-To-Open Shown)
Neutral = White
AC Cable
Earth = Green
Hot = Black
Cord grip
Power Supply
Fig-4: Mercury 310 Controller Features
14
desired button on remote
control, then within 2 seconds
press & release the STEP,
OPEN, or LATCH button
on Mercury controller. LED
ashes twice & alarm chirps
to indicate progamming
success.
To program the OXI
receiver, press/hold
Gate Limit Learn Procedure:
1. Set function knob to LRN MOTOR 1
(display ashes L1).
2. Use Left/Right buttons to “jog” gate
to between open and close limits.
3. Press/hold both left and right but-
tons for two (2) seconds.
4. Display will show solid L1 and gate
will run at crawl speed to rst limit.
5. After reaching rst limit, display
ashes between OP and CL (LEDs
also ash).
6. Observe current position of the gate
and do only one of the following:
If gate is at open limit, press the
open button.
If gate is at close limit, press the
close button.
7. Gate auto-runs to 2nd limit at crawl
speed & stops, then runs to 1st limit
at normal speed & stops, then runs
to the 2nd limit at normal speed &
stops.
8. When finished, display will show
either OP or CL, depending on
buttons pressed during procedure.
9. If dual gate, set function knob to
LEARN MOTOR 2 (display ashes
L2) & repeat all steps for 2nd motor.
N.O.
+V
+V
+V
+V
N.O.
N.O.
N.O.
N.O.
N.O.
N.C.
COM
COM
COM
COM
N.O.
COM
N.O.
COM
10K
Safety
Sensors
Loop Detectors
BlueBUS
+12 VDC
+12 VDC
(OFF in Standby)
+12 VDC
Guard
Station
Controls
(Step-By-Step)
Remote
Input
Fire Dept.
(Emergency
Access)
Control
N.O.
Control
Control
LOOP 1
(Obstruct)
LOOP 2
(Shadow)
LOOP 3
(Exit)
18-24V DC/
12V Solar 12V
Battery
Actuator Motor Connections
+
+_
_
+12 VDC
(OFF in Standby)
COM
Step Button
Open Button
Latch Button
Fail Safe Button
(On/Off)
Alarm Button (On/Off)
Battery Health LED
Alarm
Battery Fuse
(30A)
DC/Solar Fuse (15A)
Battery Power
Indicator LED
DC/Solar Power
Indicator LED
OXI Radio Port
Radio Program:
Display
Arrow Buttons
Left & Right
Function
Knob
Firmware
Update (Motor 1/Motor 2)
(Open, Close, Stop/Clear)
Gate Control Buttons
Open/Close Limit LEDs
Mercury 310 Power Outputs
Location Voltage Amps Standby Mode
INPUTS
12VDC 500 mA
On
SENSORS
LOOPS On
OUTPUTS
R
U
N
L
E
A
F
D
E
L
A
Y
C
L
O
S
E
T
I
M
E
R
L
R
N
M
O
T
O
R
1
F
O
R
C
E
L
R
N
M
O
T
O
R
2
Mercury 310 Power Requirements
> Battery = 12VDC sealed lead acid
> Solar panel = 12V (17-20V MPP)
> DC input = 18-24V high current
6 foot min.
from pivot
install
Conduit for BlueBUS
and 2nd actuator cable
BlueBUS
Photo Eye
Open
Limit Vehicle Loop
Open
Limit
Close
Limit
8
14
9
10
3
5
4
13
13 13
11
1
7 12
2
6
Fig-3: Power Supply Wiring
Wire Nut (x3)
CAUTION! Do not
mount the control
box where the
person using the
push button on box
can come in contact
with the gate!
!
13
12
as loop detectors, photo
eyes, or other safety
devices. See accessory
inputs in image below.
Connect other
accessories, such
Perform Gate Limit
Learn procedure
(see below right).
11 Attach
warning
6
7
12
7
12
Actuator Cable
LEGEND
BlueBUS Wiring
Loop Wiring
AC Power Wiring
signs to gate(s).