Digital Monitoring Products Secure Switch Programming Guide

Type
Programming Guide

Digital Monitoring Products Secure Switch is an access control device that offers enhanced security for computer networks and data access. It integrates with DMP XR200-485 Command Processor panels, enabling authorized personnel to control physical access to computers and data networks using proximity cards. The Secure Switch features a tamper-supervised relay switch that provides power to the computer or connects the data network only after a valid card is presented and verified. This ensures that unauthorized individuals cannot access sensitive information or gain entry to restricted areas.

Digital Monitoring Products Secure Switch is an access control device that offers enhanced security for computer networks and data access. It integrates with DMP XR200-485 Command Processor panels, enabling authorized personnel to control physical access to computers and data networks using proximity cards. The Secure Switch features a tamper-supervised relay switch that provides power to the computer or connects the data network only after a valid card is presented and verified. This ensures that unauthorized individuals cannot access sensitive information or gain entry to restricted areas.

LT-0477 (11/00)
INSTALLATION SecureSwitchTM Computer Intrusion Control
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
â–¼
1
88 Not used
7 Not used
6 Not used
5 Not used
4 Not used
3 Not used
2 ORG/WHT
1 WHT/ORG Relay switch - XR200-485
}
back view
â–¼
1
88 BRN/WHT
7 WHT/BRN
6 Not used
5 Not used
4 Not used
3 Not used
2 ORG/WHT
1 WHT/ORG
Tamper
XR200-485
Relay Switch
}
}
N. I. C. N. I. C.NETSecure NET
â–¼
1
88 BRN/WHT
7 WHT/BRN
6 Not used
5 Not used
4 Not used
3 Not used
2 ORG/WHT
1 WHT/ORG
Tamper
XR200-485
Relay Switch
}
}
Description
The DMP SecureSwitchTM allows a DMP XR200-485 Command ProcessorTM panel to control physical access to computers
and data networks. SecureSwitch incorporates a tamper supervised relay switch that provides power to the computer or
connects a data network only after an authorized user presents a card to a reader and it is verified. Presenting a card again
turns off the computer or disconnects the data network from the computer's network interface card (N. I. C.).
SecureSwitchTM PR - Allows tamper supervised control of 120VAC power to computer.
SecureSwitchTM SP - Access control to a single data network connection for the computer (not tamper supervised).
SecureSwitchTM DR - Allows tamper supervised switching between two data networks available to the computer, one
secure and one non-secure. Also requires manual operation to complete switch.
Power Requirements
SecureSwitch relay activation: 50mA @ 12 VDC
Installation
This document provides specific wiring and programming instructions for the installation of one SecureSwitch PR and one
SecureSwitch DR to a computer(s) and is provided to inform and train the installer of proper operation and programming.
The installer should realize that this is not the only possible combination of wiring and programming that will provide proper
operation. For example, zones used for supervision may be from other available Keypad or LX-Bus devices. Also, specific
user numbers may be different.
In an application that requires one power and one data switch per computer, eight computers is the maximum that can be
controlled from one XR200-485. The following figures and tables illustrate the installation of SecureSwitches for one, four,
and eight computers.
2
SecureSwitch Installation
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
DEVICES SETUP
Device
Number Partition
Number Device
Name Access
Areas Egress
Areas Strike
Time Fire Exit Out
Group Override
1 (Std) 1 Cmp 1 Network Sw 1 Blank 0 (Toggle) No No No
2 (Std) 1 Cmp 1 Power Sw 2 Blank 0 (Toggle) No No No
AREA INFORMATION
Partition
Number Area
Number Area
Name Account
Number Auto
Arm Auto
Disarm Armed
Output Late
Output Common
Area
1 1 Cmp 1 Network Sw No Change No No 0 0 No
1 2 Cmp 1 Power Sw No Change No No 0 0 No
ZONE INFORMATION
Zone Number Zone Name Zone Type Partition Fire Bell Out Alarm Action
11 Cmp 1 Net Tamper SV 1 0 No Changes
21 Cmp 1 Pwr Tamper SV 1 0 No Changes
USER PROFILES
Profile
Number Profile Name Access Arm / Disarm Door Access Allow
1 Cmp 1 Network Sw 1 No Yes Any
2 Cmp 1 Power Sw 2 No Yes Any
USER CODES
User Number User Code Number User Name Profile Number
11 Enter User Code (Pin) Enter user name 1
12 Enter User Code (Pin) Enter user name 2
1 2 3 4 5 6 7 8 9 10 11 12 13
XR200-485 Command Processor Panel
Secure
Switch
PR
Power Out
Power In
ON/OFF
N/C Tamper
To AC power
WHT/ORANGE
BRN/WHT
To computer AC
power input
ORANGE/WHT
WHT/BRN
N/O
Common
Wiegand Proximity
Card Reader
DMP 733 Wiegand
Interface Module
Address 2
Secure Switch
DR
ON/OFF
N/C Tamper
Network In
Network Out
To computer
network input
To network
Keypad Data Bus
Card Reader Output
RED
YELLOW
GREEN
BLACK
90
1234
5678
POWER
SGT. JONES OFFICE
FRI 2:51 AM
ARMED
COMMAND
ORANGE
Door Strike Common
WHT/BRN
BRN/WHT
EOL
EOL
DMP 793 Keypad w/
Proximity Card Reader
Address 1
ORANGE/WHT
GRAY
Zone 1
WHT/ORANGE
Zone 1
WHT/BRN
BRN/WHT
SecureSwitch Wiring for One Computer
Panel Programming for One Computer
When programming the XR200-485 panel for use with the Secure Switch, access the Programming Menu and follow the
setup instructions below. Refer to the XR200-485 Programming Guide (LT-0466) for more programming information.
User Code Programming for One Computer
After completing the XR200-485 programming, access the User Menu and follow the setup instructions below. Refer to the
XR200-485 User's Guide (LT-0364) for more information.
SecureSwitch Installation
3
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
DEVICE SETUP
Device
Number Partition
Number Device
Name Access
Areas Egress
Areas Strike
Time Fire
Exit Out
Group Override
1 (Std) 1 Cmp 1 Network Sw 1 Blank 0 (Toggle) No No No
2 (Std) 1 Cmp 1 Power Sw 2 Blank 0 (Toggle) No No No
3 (Std) 1 Cmp 2 Network Sw 3 Blank 0 (Toggle) No No No
4 (Std) 1 Cmp 2 Power Sw 4 Blank 0 (Toggle) No No No
5 (Std) 1 Cmp 3 Network Sw 5 Blank 0 (Toggle) No No No
6 (Std) 1 Cmp 3 Power Sw 6 Blank 0 (Toggle) No No No
7 (Std) 1 Cmp 4 Network Sw 7 Blank 0 (Toggle) No No No
8 (Std) 1 Cmp 4 Power Sw 8 Blank 0 (Toggle) No No No
AREA INFORMATION
Partition
Number Area
Number Area
Name Account
Number Auto
Arm Auto
Disarm Armed
Output Late
Output Common
Area
1 1 Cmp 1 Network No Change No No 0 0 No
1 2 Cmp 1 Power No Change No No 0 0 No
1 3 Cmp 2 Network No Change No No 0 0 No
1 4 Cmp 2 Power No Change No No 0 0 No
1 5 Cmp 3 Network No Change No No 0 0 No
1 6 Cmp 3 Power No Change No No 0 0 No
1 7 Cmp 4 Network No Change No No 0 0 No
1 8 Cmp 4 Power No Change No No 0 0 No
SecureSwitch Wiring for Four Computers
Panel Programming for Four Computers
Secure
Switch
PR
Power Out
Power In
ON/OFF
N/C Tamper
To computer
AC power input
T
o
AC
power
N/O
Common
DMP 733 Wiegand
Interface Module
Keypad Data Bus
EOL Zone 1
WHT/ORG
ORG/WHT
WHT/BRN
BRN/WHT
7 8 9 10
XR200-485 Command Processor Panel
Keypad Data Bus
RED
YELLOW
GREEN
BLACK
SecureSwitch DR
Reader
Reader
Reader Reader
Reader
Reader
ReaderReader
Address 1
Address 2
Address 3
Address 4 Address 8
Address 7
Address 6
Address 5
Zone 21
Zone 11
Zone 31
Zone 41
Zone 51
Zone 61
Zone 71
Zone 81
90
12 34
56 78
POWER
SGT. JONES OFFICE
FRI 2 : 51 AM
ARMED
COMMAND
A B C D E F G H I J K L
Y Z
M N O P Q R S T U V W X
733
733
733
733733
733
733
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
Power Switch 1
Network Switch 1
Power Switch 2
Network Switch 2
Power Switch 3
Network Switch 3
Power Switch 4
Network Switch 4
Strike
Strike
Strike
Strike Strike
Strike
Strike
Strike
Computer # 1
Computer # 2
Computer # 3
Computer # 4
Detail B
Detail A
See Detail B for connection
See Detail A for connection
Secure Switch
DR
ON/OFF
N/C Tamper
Network In
Network Out
To network
90
1234
5678
POWER
SGT. JONES OFFICE
FRI 2:51 AM
ARMED
COMMAND
Door Strike N/O
Door Strike Common
Ground
Zone 1
EOL
DMP 793 Keypad w/
Proximity Card Reader
ORG/WHT
WHT/BRN
BRN/WHT
GRAY
WHT/ORG
4
SecureSwitch Installation
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
ZONE INFORMATION
Zone Number Zone Name Zone Type Partition Fire Bell Out Alarm Action
11 Cmp 1 Net Tamper SV 1 0 No Changes
21 Cmp 1 Pwr Tamper SV 1 0 No Changes
31 Cmp 2 Net Tamper SV 1 0 No Changes
41 Cmp 2 Pwr Tamper SV 1 0 No Changes
51 Cmp 3 Net Tamper SV 1 0 No Changes
61 Cmp 3 Pwr Tamper SV 1 0 No Changes
71 Cmp 4 Net Tamper SV 1 0 No Changes
81 Cmp 4 Pwr Tamper SV 1 0 No Changes
USER PROFILES
Profile
Number Profile Name Access Arm / Disarm Door Access Allow
1 Cmp 1 Network 1 No Yes Any
2 Cmp 1 Power 2 No Yes Any
3 Cmp 2 Network 3 No Yes Any
4 Cmp 2 Power 4 No Yes Any
5 Cmp 3 Network 5 No Yes Any
6 Cmp 3 Power 6 No Yes Any
7 Cmp 4 Network 7 No Yes Any
8 Cmp 4 Power 8 No Yes Any
USER CODES
User Number User Code Number User Name Profile Number
11 Enter User Code (Pin) Enter User Name 1
12 Enter User Code (Pin) Enter User Name 2
13 Enter User Code (Pin) Enter User Name 3
14 Enter User Code (Pin) Enter User Name 4
15 Enter User Code (Pin) Enter User Name 5
16 Enter User Code (Pin) Enter User Name 6
17 Enter User Code (Pin) Enter User Name 7
18 Enter User Code (Pin) Enter User Name 8
Panel Programming for Four Computers (continued)
User Code Programming for Four Computers
SecureSwitch Installation
5
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
Secure
Switch
PR
Power Out
Power In
ON/OFF
N/C Tamper
To computer
AC power input
T
o
AC
power
N/O
Common
DMP 733 Wiegand
Interface Module
Keypad Data Bus
EOL
Zone 1
WHT/ORG
ORG/WHT
WHT/BRN
BRN/WHT
Detail A
Detail B
Secure Switch
DR
ON/OFF
N/C Tamper
Network In
Network Out
To network
90
1234
5678
POWER
SGT. JONES OFFICE
FRI 2:51 AM
ARMED
COMMAND
Door Strike N/O
Door Strike Common
Ground
Zone 1
EOL
DMP 793 Keypad w/
Proximity Card Reader
ORG/WHT
WHT/BRN
BRN/WHT
GRAY
WHT/ORG
7 8 9 10 11 12 13 14
XR200-485 Command Processor Panel
Keypad Data Bus
RED
YELLOW
GREEN
BLACK
90
1234
5678
POWER
SGT. JONES OFFICE
FRI 2: 51 AM
ARMED
COMMAND
733
SecureSwitch PR
90
12 34
5678
POWER
SGT. JONES OFFICE
FRI 2: 51 AM
ARMED
COMMAND
90
12 34
56 78
POWER
SGT. JONES OFFICE
FRI 2: 51 AM
ARMED
COMMAND
733
733
733
733 733
733
733
733
Address 5
Zone 51
Reader
Reader
Reader
Reader
Reader
Reader
Reader
733 733
733 733
Zone 51
Zone 71
Zone 81
To
panel
Zone 4
Zone 1
Zone 41
Zone 11
Zone 21
Zone 31
Address 1
Address 2
Address 3
Address 4
Address 9
Address 10
Address 11
Address 12 Address 16
Address 15
Address 8
Address 7
Address 14
Address 13
Address 6
Network Switch 1
Power Switch 1
Reader
Reader
Reader
Reader
Reader
Reader
Reader
Reader
Reader
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch DR
SecureSwitch PR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
SecureSwitch PR
SecureSwitch DR
Network Switch 5
Power Switch 5
Network Switch 2
Power Switch 2
Network Switch 3
Power Switch 3
Network Switch 4
Power Switch 4
Network Switch 8
Power Switch 8
Network Switch 7
Power Switch 7
Network Switch 6
Power Switch 6
â–²
â–²
â–²
â–²
â–²
â–²
â–²
EOL
To
panel
Zone 3
To
panel
Zone 2
To
panel
Zone 8
To
panel
Zone 7
To
panel
Zone 6
To
panel
Zone 5
StrikeStrike
Strike Strike
Strike
Strike
Strike
Strike
Strike
Strike
Strike
Strike
Strike Strike
Strike
Strike
See Detail A for connection
See Detail B for connection
Computer #1
Computer #2
Computer #3
Computer #4
Computer #5
Computer #6
Computer #7
Computer #8
SecureSwitch Wiring for Eight Computers
6
SecureSwitch Installation
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
DEVICE SETUP
Device
Number Partition
Number Device
Name Access
Areas Egress
Areas Strike
Time Fire
Exit Out
Group Override
1 (Std) 1 Cmp 1 Network Sw 1 Blank 0 (Toggle) No No No
2 (Std) 1 Cmp 1 Power Sw 2 Blank 0 (Toggle) No No No
3 (Std) 1 Cmp 2 Network Sw 3 Blank 0 (Toggle) No No No
4 (Std) 1 Cmp 2 Power Sw 4 Blank 0 (Toggle) No No No
9 (Std) 1 Cmp 3 Network Sw 5 Blank 0 (Toggle) No No No
10 (Std) 1 Cmp 3 Power Sw 6 Blank 0 (Toggle) No No No
11 (Std) 1 Cmp 4 Network Sw 7 Blank 0 (Toggle) No No No
12 (Std) 1 Cmp 4 Power Sw 8 Blank 0 (Toggle) No No No
5 (Std) 2 Cmp 5 Network Sw 1 Blank 0 (Toggle) No No No
6 (Std) 2 Cmp 5 Power Sw 2 Blank 0 (Toggle) No No No
13 (Std) 2 Cmp 6 Network Sw 3 Blank 0 (Toggle) No No No
14 (Std) 2 Cmp 6 Power Sw 4 Blank 0 (Toggle) No No No
7 (Std) 3 Cmp 7 Network Sw 1 Blank 0 (Toggle) No No No
8 (Std) 3 Cmp 7 Power Sw 2 Blank 0 (Toggle) No No No
15 (Std) 3 Cmp 8 Network Sw 3 Blank 0 (Toggle) No No No
16 (Std) 3 Cmp 8 Power Sw 4 Blank 0 (Toggle) No No No
AREA INFORMATION
Partition
Number Area
Number Area
Name Account
Number Auto
Arm Auto
Disarm Armed
Output Late
Output Common
Area
1 1 Cmp 1 Network No Change No No 0 0 No
1 2 Cmp 1 Power No Change No No 0 0 No
1 3 Cmp 2 Network No Change No No 0 0 No
1 4 Cmp 2 Power No Change No No 0 0 No
1 5 Cmp 3 Network No Change No No 0 0 No
1 6 Cmp 3 Power No Change No No 0 0 No
1 7 Cmp 4 Network No Change No No 0 0 No
1 8 Cmp 4 Power No Change No No 0 0 No
2 1 Cmp 5 Network No Change No No 0 0 No
2 2 Cmp 5 Power No Change No No 0 0 No
2 3 Cmp 6 Network No Change No No 0 0 No
2 4 Cmp 6 Power No Change No No 0 0 No
3 1 Cmp 7 Network No Change No No 0 0 No
3 2 Cmp 7 Power No Change No No 0 0 No
3 3 Cmp 8 Network No Change No No 0 0 No
3 4 Cmp 8 Power No Change No No 0 0 No
ZONE INFORMATION
Zone Number Zone Name Zone Type Partition Fire Bell Out Alarm Action
11 Cmp 1 Net Tamper SV 1 0 No Changes
21 Cmp 1 Pwr Tamper SV 1 0 No Changes
31 Cmp 2 Net Tamper SV 1 0 No Changes
41 Cmp 2 Pwr Tamper SV 1 0 No Changes
1 Cmp 3 Net Tamper SV 1 0 No Changes
2 Cmp 3 Pwr Tamper SV 1 0 No Changes
3 Cmp 4 Net Tamper SV 1 0 No Changes
4 Cmp 4 Pwr Tamper SV 1 0 No Changes
51 Cmp 5 Net Tamper SV 1 0 No Changes
61 Cmp 5 Pwr Tamper SV 1 0 No Changes
5 Cmp 6 Net Tamper SV 1 0 No Changes
6 Cmp 6 Pwr Tamper SV 1 0 No Changes
71 Cmp 7 Net Tamper SV 1 0 No Changes
81 Cmp 7 Pwr Tamper SV 1 0 No Changes
7 Cmp 8 Net Tamper SV 1 0 No Changes
8 Cmp 8 Pwr Tamper SV 1 0 No Changes
Panel Programming for Eight Computers
SecureSwitch Installation
7
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
USER PROFILES
Partition Profile
Number Profile Name Access Arm / Disarm Door
Access Allow
1 1 Cmp 1 Network 1 No Yes Any
1 2 Cmp 1 Power 2 No Yes Any
1 3 Cmp 2 Network 3 No Yes Any
1 4 Cmp 2 Power 4 No Yes Any
1 5 Cmp 3 Network 5 No Yes Any
1 6 Cmp 3 Power 6 No Yes Any
1 7 Cmp 4 Network 7 No Yes Any
1 8 Cmp 4 Power 8 No Yes Any
2 1 Cmp 5 Network 1 No Yes Any
2 2 Cmp 5 Power 2 No Yes Any
2 3 Cmp 6 Network 3 No Yes Any
2 4 Cmp 6 Power 4 No Yes Any
3 1 Cmp 7 Network 1 No Yes Any
3 2 Cmp 7 Power 2 No Yes Any
3 3 Cmp 8 Network 3 No Yes Any
3 4 Cmp 8 Power 4 No Yes Any
USER CODES
Partition User Number User Code Number User Name Profile Number
1 11 Enter User Code (Pin) Enter User Name 1
1 12 Enter User Code (Pin) Enter User Name 2
1 13 Enter User Code (Pin) Enter User Name 3
1 14 Enter User Code (Pin) Enter User Name 4
1 15 Enter User Code (Pin) Enter User Name 5
1 16 Enter User Code (Pin) Enter User Name 6
1 17 Enter User Code (Pin) Enter User Name 7
1 18 Enter User Code (Pin) Enter User Name 8
2 11 Enter User Code (Pin) Enter User Name 1
2 12 Enter User Code (Pin) Enter User Name 2
2 13 Enter User Code (Pin) Enter User Name 3
2 14 Enter User Code (Pin) Enter User Name 4
3 11 Enter User Code (Pin) Enter User Name 1
3 12 Enter User Code (Pin) Enter User Name 2
3 13 Enter User Code (Pin) Enter User Name 3
3 14 Enter User Code (Pin) Enter User Name 4
User Code Programming for Eight Computers
Notes
Digital Monitoring Products
2500 N. Partnership Boulevard Springfield, MO 65803 800-641-4282
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Digital Monitoring Products Secure Switch Programming Guide

Type
Programming Guide

Digital Monitoring Products Secure Switch is an access control device that offers enhanced security for computer networks and data access. It integrates with DMP XR200-485 Command Processor panels, enabling authorized personnel to control physical access to computers and data networks using proximity cards. The Secure Switch features a tamper-supervised relay switch that provides power to the computer or connects the data network only after a valid card is presented and verified. This ensures that unauthorized individuals cannot access sensitive information or gain entry to restricted areas.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI