GSS STI 1932 CT Assembly Instruction Manual

Type
Assembly Instruction Manual
Assembly Instruction
STI 1932 CT
Default access data:
192.168.0.120
User: admin
Password: geheim
- 2 - STI 1932 CT
Contents
1 Safety regulations and notes ........................................................................4
2 General information ....................................................................................6
2.1 Packing contents ............................................................................6
2.2 Meaning of the symbols used ..........................................................6
2.3 Technical data ...............................................................................6
2.4 Description ...................................................................................7
General ........................................................................................7
User .............................................................................................9
Administrator access .................................................................9
Guest access ............................................................................9
3 Assembly ..................................................................................................10
3.1 Device overview ..........................................................................10
3.2 Installing the device .....................................................................11
3.3 Potential equalisation (PE) .............................................................12
3.4 Connecting the device ..................................................................12
3.5 Changing a Power Module ...........................................................13
3.6 Changing a Case Fan ..................................................................14
4 Configuration / Updates ............................................................................15
4.1 Initial configuration ......................................................................15
4.2 Configuration ..............................................................................18
Overview window .......................................................................18
Perform changes .........................................................................19
Number format............................................................................19
Configuration menus ....................................................................20
Input .....................................................................................20
Redundant Input (Software option) ............................................22
Output ..................................................................................25
Filter .....................................................................................28
NIT .......................................................................................31
LCN – Logical Channel Numbering ..........................................35
System menus .............................................................................37
Logbook ................................................................................37
- 3 - STI 1932 CT
Notification ...........................................................................38
Network ................................................................................40
OpenVPN .............................................................................41
Security .................................................................................42
- Administrator access .............................................................42
- Guest access ........................................................................42
Firmware ...............................................................................43
- Output Modulation of Head-end Station: ..................................44
- System settings: ....................................................................44
- Firmware update: .................................................................44
- Backup: ...............................................................................45
- Manager: ............................................................................45
- Reset to factory defaults: ........................................................46
- System restart: ......................................................................46
- Software Options (fee-based): ................................................46
- Ping (Network Diagnostic Tool): ..............................................47
User ......................................................................................47
5 Channel and frequency tables ....................................................................48
- 4 - STI 1932 CT
1 safety regulations and notes
The devices meet the EU directives 2011/65/EU, 2014/30/EU and
2014/35/EU.
This device is subject to the provisions of protection class I. Operate the
device only to mains sockets with protective conductor connection!
If the power cords need to be replaced, only use OEM power cords.
The standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be
observed, especially concerning equipotential bonding and earthing.
Observe the relevant country-specific standards, regulations and guidelines
on the installation and operation of antenna systems.
Before starting installation or service work disconnect the receiving system
from mains.
Do not perform installation and service work during thunderstorms.
Assembly, installation and servicing must be carried out by an authorised
electrician.
Caution! Dangerous voltage! For a complete disconnection from the mains,
both mains plugs must be pulled out of the mains sockets. Ensure that the
mains plugs can be pulled out without difficulties.
• The head-end station should only be installed in a room where the permis-
sible ambient temperature range (0 °C … +50 °C ) can be maintained, even
during fluctuations in climatic conditions.
• To avoid too strong interacted heating of the head-end stations it is not
admissible to mount them one upon the other without using thermic precau-
tions (e.g. permanently air recirculation, ventilation etc.).
If additional fans are to be used to circulate the air, ensure that the system
will be shut down (disconnected from mains) should any one of the fans fail.
Install the head-end station
- in a dry, dust-free environment, in such a manner that it is protected from
moisture, fumes, splashing water and dampness
- where it is protected from direct exposure to sunlight
- on a vibration-free wall or floor construction
- not within the immediate vicinity of heat sources
In case of the formation of condensation wait until the system is completely
dried.
Ensure that the head-end station is adequately ventilated.
Do not cover the ventilation openings!
Do not install the head end in cabinets or recesses which are not ventilated.
Do not place any vessels containing liquids on the head-end station.
- 5 - STI 1932 CT
Do not place anything on the head-end station which could initiate fires
(e.g. candles).
Due to the risk of fires caused by lightning strikes, we recommend that
all mechanical parts (e.g. distributor, equipotential bonding rail, etc.) be
mounted on a non-combustible base. Wood panelling, wooden beams,
plastic covered panels and plastic panels are all examples of combustible
bases.
Avoid short circuits!
To ensure electromagnetic compatibility, make sure all connections are tight
and that the covers are screwed on securely.
No liability is accepted for damage caused by faulty connections or inap-
propriate handling of the device.
The firmware contains components which are licensed as Open Source
software. The components to which this relates and the respective license
terms can be called up via menu Help/Licences.
This parts of software source code can be provided at cost price on CD
upon request. The licensee is granted a non-exclusive right of use for the
Open Source Software by the respective right holders used; the conditions
stipulated by the respective valid license terms apply. The license terms of
this license only apply to the components which are not listed as Open
Source software.
In relation to the licensor the regulations on liability and warranty in these
license terms apply for the whole software. The liability and warranty regu-
lations of the Open Source licenses only apply in relation to the respective
right holders.
Test the firmware versions of the device and update them if necessary. The
current firmware version can be found at "www.mygss.eu".
Take action to prevent static discharge when working on the device!
Electronic devices should never be disposed of in the household rubbish. In accordance
with directive 2002/96/EC of the European Parliament and the European Council from
January 27, 2003 which addresses old electronic and electrical devices, such devices
must be disposed of at a designated collection facility. At the end of its service life,
please take your device to one of these public collection facilities for proper disposal.
- 6 - STI 1932 CT
2 general information
2.1 PaCki n g Co nt en ts
1 STI 1932 CT 1 LAN cable
1 Brief assembly instructions 2 Mains cable
2.2 mea n in g o f th e sym bo l s us ed
Important note Disconnection, all power plugs
Danger by electrical shock
—> General note
Performing works
2.3 teC h niC al data
The devices meet the following EU directives:
2011/65/EU, 2014/30/EU, 2014/35/EU
The product fulfils the guidelines and standards for CE labelling (page 49).
Unless otherwise noted all values are specified as "typical".
Input data
Over all input data rate/interface (∑ lines 1-16/17-32): .......... ≤ 800 MBit/s
Buffer memory .......................................................................60 kBit/line
(corresponds e.g. at 50 MBit/s to approx. 1 ms buffer)
IGMP ................................................................................................V2
Protocols: .......................................................... UDP (User Data Protocol),
RTP (Real-Time Transport Protocol)
RF output QAM
Frequency range: ............................................. 42.0 MHz … 868.0 MHz
Types of modulation: ..................................QAM 4, 16, 32, 64, 128, 256
Output level: ......................................................................73…89 dBμV
Dynamic phase error: ................................................................... < 0.2 °
MER: ............................................................................................45 dB
Output impedance: .........................................................................75 Ω
Symbol rate: ................................................................ 1000…7500 kBd
- 7 - STI 1932 CT
RF output COFDM
Frequency range: ............................................. 42.0 MHz … 868.0 MHz
Types of modulation: ........................................ QPSK, 16 QAM, 64 QAM
Transmission modes ............................................................................ 2k
Code rates ....................................................... 1/2, 2/3, 3/4, 5/6, 7/8
Guard intervals .................................................... 1/4, 1/8, 1/16, 1/32
Output level: ......................................................................73…89 dBμV
Output impedance: .........................................................................75 Ω
LAN interfaces for HTML control/update
Standard: .............................................................................100-BASE-T
Connections
LAN (for data) 1000-BASE-T: ..............................................2 RJ45 sockets
LAN (for control) 100-BASE-T: .............................................2 RJ45 sockets
RF output: .............................................................................. 1 F socket
RF test output (-25 dB): ............................................................ 1 F socket
General
Mains units: ...... 2 (redundant; can be replaced separately during operation)
Supply voltage ....................................................100…240 V, 50/60 Hz
Power consumption: .............................................................. max. 75 W
Cooling fans: .....................3 (can be replaced separately during operation)
Ambient temperature: ............................................................ 0…+50 °C
Dimensions (W x H x D): ................. 483 mm x 44.5 mm (1HU) x 490 mm
Weight: ....................................................................................... 6.2 kg
2.4 de sC ri P tio n
The head-end station converts 32 (2x16) MPTS streams into 32 QAM or
COFDM modulated transponders. A further 32 MPTS data streams can be
provided as redundant input signals as a software option for an extra charge.
ge ner al
The station is equipped with two LAN inputs, one RF output and one test output
(–25 dB). The MPTS input data streams of lines 1-16 are fed to the left LAN
input that the lines 17-32 at the right LAN input.
- 8 - STI 1932 CT
RF OUT
Combiner
TEST
–25dB
MPTS Stream 1
MPTS Stream 16
MPTS Stream 17
MPTS Stream 32
LAN 1
LAN 2
Modulator
"1"
Modulator
"17"
Modulator
"32"
Modulator
"16"
The configuration of the station is to be done via an HTML user interface via a
PC and a standard HTML browser connected to the configuration input
(Con-
trol)
.
The two configuration inputs are connected via an internal switch. Several sta-
tions can thus be cascaded for configuration.
GSS
OpenVPN
Server
If the Control input is connected to
the Internet, after the initial setup,
you can get worldwide access to the
station via an OpenVPN connection
– by PC, tablet or smart phone with
Internet access.
—> When using mobile terminals – dependent on your mobile contract
additional connection costs / data transfer costs may also be
incurred here.
- 9 - STI 1932 CT
32 LEDs provide an indication of the status of the 32 lines based on their col-
our and indicate if the respective line is switched on (LED illuminates) or off.
The LEDs are blinking red/green during data overflow.
The station is powered by two independent power supplies (redundancy). The
power supplies can be replaced individually during operation. If one power
supply unit fails, a warning signal sounds.
If the control input has connection to the Internet, the device can send a warn-
ing e-mail when a signal, power supply or one of the fans fails.
us e r
adm i n is tr ato r aCC ess
The user admin has access to all menus and may make changes.
—> The default password for the user admin is geheim.
gu est aCC ess
The user gast has access to (almost) all menus, but may not make any changes.
—> The default password for the user gast is gast.
A guest access is shown in all menus:
The button has no function!
- 10 - STI 1932 CT
3 assembly
3.1 de v iC e overv i ew
sw rt ge
Caution!
Dangerous
voltage!
Separate
all power
sources
8
9 10 11 12
14 15 1613 14 15 1613 1721
76431 2 5
1
9
17
25
8
16
24
32
20
1
9
17
25
8
16
24
32
5
1
MPTS input lines 1-16
2
MPTS input lines 17-32
3
Reset IP address, host name and password*
4
Alarm tone off
5
Status LEDs of lines 1…32**
6
Fan access
7
LAN socket for configuration
8
Power ON/OFF
9
GND fan connectors
10
Fan monitoring connectors
11
+12 V fan connectors
12
Fan screws
13
PSU releases
14
PSU brackets
15
IEC connectors C14; connectors for mains cables
16
PSU status LEDs***
17
Connector for potential equalisation
20
RF output
21
Test output –25dB
* Reset IP address/host name/password (hold depressed for more than 5 seconds) to
192.168.0.120/gss/geheim
**
Green = good signal; red = no signal; red/green blinking = data overflow; off = modulator off
*** Power off + no fault –> LED
16
blinks green
Power on + no fault –> LED
16
lights green
Power on + fault –> LED
16
blinks red
- 11 - STI 1932 CT
3.2 insta ll i ng t he d e vi C e
– The device should only be installed in a room where the permissible ambi-
ent temperature range (0 °C +50 °C ) can be maintained, even during
fluctuations in climatic conditions.
Attach four cage nuts
26
at the installation site.
We recommend the use of lateral slide rails/component carriers in order to
relieve the front panel.
26
Screw the unit with the mounting screws
28
and the washer
27
to the four
cage nuts
26
.
2727
2828
- 12 - STI 1932 CT
3.3 Pote n ti al eq ualisat i on (Pe)
Equalise the potential (PE) in accordance with IEC/EN/DIN EN 60728.
Connect the PE connection terminal
17
to a PE rail (supplied by customer)
using the PE wire (Cu 4 mm
2
- 9 mm
2
).
3.4 Con n eC tin g th e d evi C e
Connect the MPTS inputs
1
and
2
to the LAN network via CAT-6 cables.
—> The device requests the required multicast IP streams via the MPTS
inputs every 60 seconds. Querier requests will not be answered!
Keep this in mind when configuring the network (Querier host time-
out > 60s).
—> You will find descriptions to important terms for configuring a
streaming network in menu Help > Multicast Setup.
Connect the attached mains cables to the IEC connectors C14
15
.
—> The power cables are equipped with lockable C13 connectors. Re-
move the connectors by pulling back the red locking pin.
Connect the mains cables to mains sockets with protective conductor con-
nections. Thereby note the voltage specified on the device.
—> This device has no primary power switch and is in standby mode im-
mediately after connecting the operating voltage. Power ON/OFF
8
switches only the secondary DC voltages!
For a complete disconnection from the mains, both mains plugs must
be pulled out of the mains sockets. Ensure that the mains plugs can
be pulled out without difficulties.
Configure the device (page 15).
If the configuration is finished connect the RF output
20
to the cable network.
- 13 - STI 1932 CT
3.5 Chan gin g a Power mo du l e
In case of a malfunction of a power module or if only one mains cable is
connected a warning signal sounds and the status LED
16
blinks red if the
set is switched on.
—>
Using button "ALARM OFF"
4
the warning signal can be switched off.
A warning e-mail will be sent out if a connection from the CONTROL input to
the Internet is established and warning e-mails are configured in the device
settings.
14 15 1613 14 15 1613
A defective power module can be exchanged during operation.
Remove the mains cable from the defective power module.
Move release
13
in direction of the arrow and pull the power module out of
the device by bracket
14
.
Insert the new power module.
—> Make sure that it is locked.
Connect the new power module to the mains cable and check whether the
status LED
16
lights green.
- 14 - STI 1932 CT
3.6 Chan gin g a Ca se fa n
If a connection from the CONTROL input to the Internet is established and
warning e-mails are configured in the device settings, a warning e-mail will be
sent out in case of a case fan malfunction.
A defective case fan can be exchanged during operation.
6
Remove the fan panel (2 screws
6
).
sw rt ge
9 10 11
12
25
Remove the 2 screws
12
of the defective fan.
Remove the wires of the defective fan from the connection
terminals (pressure point
25
).
Mount the new fan (screws
12
). An arrow on the fan
housing indicates the flow direction. Mount the fan so
that the air stream is passed into the device.
Shorten if necessary connecting cables in accord-
ance. The cable ends must be stripped 6…7 mm.
Push the connecting cables in the space between the fan and case ground.
Attach the stripped ends of the connecting wires to the appropriate termi-
nals (pressure point
25
):
– the black wire to the lower terminal (3 x minus terminal
9
).
– the red wire to the middle terminal (3 x plus terminal
11
).
– the yellow wire on the upper terminal (3 x monitoring terminal
10
).
Mount the fan panel (2 screws
6
).
—> Make sure that no wires will be clamped between fan and housing.
- 15 - STI 1932 CT
4 Configuration / uPdates
The configuration of the STI 1932 CT is to be done via an HTML user interface
via a PC and a standard HTML browser.
4.1 in itia l Co nfi gu r ati o n
Connect a PC via a LAN cable directly to a configuration input
7
.
—> The PC and the head-end station must be within the same network
(same IP address range). Cookies must be accepted and JavaScript
must be active.
Use current browser versions.
—> Example for IP address setting with Windows 7 operating system:
• For the initial setup open the properties for TCP/IPv4 of the PC:
> Control Panel
> Network and Sharing Center
> LAN connection
> Properties
- 16 - STI 1932 CT
> Internet Protocol Version 4 (TCP/IPv4)
> Properties
• Activate point "Use the following IP address".
• Enter e.g. 192.168.0.2 for the IP address.
• Enter for the Subnet mask 255.255.255.0.
• Confirm the setting with "OK".
- 17 - STI 1932 CT
Start the browser, enter the IP address of the device (factory default is
192.168.0.120) and start the establishment of the connection.
Enter user "admin" and your Password and click on button "Login".
The default password is "geheim".
—> For further logins observe the menus System > Network and System
> OpenVPN!
—> The Overview window is displayed.
First, an "empty" table is displayed (as with all menus). While the
data is read from the device ...
… is displayed.
—> Changes in the menus are only transmitted to the head-end station
when you click the button!
- 18 - STI 1932 CT
4.2 Con f ig u r ati on
ov erv i ew w i n dow
50
51
57
56
54
55
58
53
52
59
61
60
50
Via the selection System you have access to the menus of the System
settings: Logbook (page 37); Notification (page 38); Network (page 40);
OpenVPN (page 41); Security (page 42); Firmware (page 43); User (page 47)
51
In all menus you will return to the Overview via the button Overview.
52
Via the selection Configuration you have access to the menus of the Con-
figuration settings: Input (page 20); Output (page 22); Filter (page 28); NIT
(page 31); LCN (page 35).
53
Herein the installed firmware version is displayed.
54
This location text can be modified arbitrary in menu System/User.
—> If you remote control head-end station at different locations, herein
you can enter the location and a local contact person.
55
Select menu language (English/German)
- 19 - STI 1932 CT
56
Herein the current system temperature as well as date and time of the last
login is displayed.
—> If a system temperature of 85°C will be reached, the system will be
shut down.
57
Via button Logout you can leave the graphical user interface.
58
Via the Help menu you can call up the assembly instructions (PDF), hints
about the configuration of a multicast network (PDF) as well as a ZIP file
containing a list and all licences of the used OpenSource software.
59
Overview of the transponder set, with output frequency, TS-/ON ID, Multi-
cast address and data rate. Via the background colour of column Line you
are informed about the quality of the input signals ( good/ no signal),
a possible exceeding the output data rate ( ), or whether the output is
switched off ( ).
—> If in menu Configuration/Input (page 20) transponder names are
NOT assigned, the name of the first station of each transponder is
displayed.
60
Hardware monitoring; shows the state of the power supplies and the fans
61
Via button Download a configuration protocol can be stored as text file
resp. opened using a text editor.
—> From this protocol file e.g. a list of the programmed stations can be
prepared using e.g. a text editor.
Per fo r m Cha ng es
Before leaving a menu, changes must be transmitted to the head-end station.
Therefore click on button .
After that is displayed for a short time in the upper right corner.
numb e r fo r m at
For entering/indication of the different IDs the number format can be set to
hexadecimal or decimal in menu System > Firmware.
- 20 - STI 1932 CT
Co n fi g ur at i on m e n us
in Pu t
100 101 102 103 104
108
110
—> Via the background colour of column Line you are informed about
the quality of the input signals ( good/ no signal), a pos-
sible exceeding the output data rate ( ), or whether the output is
switched off ( ).
100
In column Input you can deactivate the input of not used lines. This pre-
vents unwanted/unnecessary data traffic on the network.
101
In column Name, you can enter a personal transponder name
—> If you delete a transponder name, the name of the first station of
this data stream is entered. If the data stream will be changed, the
transponder name will NOT be changed automatically!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49