Anolis Ambiane™ User manual

  • Hello! I am an AI chatbot trained to assist you with the Anolis Ambiane™ User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
User manual
Ambiane PW
The unit generates light by means of high power LEDs. The product was designed for indoor use only.
1. Attention
Theunitmustbeinstalledbyaqualiedelectricianinaccordancewithall
national and local electrical and construction codes and regulations.
The unit was designed for indoor use only.
Avoid looking directly into the LED light beam at close range!
Donotinstalltheunitnearhighlyinammableliquidsormaterials.
Do not allow anything to rest on the unit.
Donotinstalltheunitnearanopename.
Do not install the unit in dirty,dusty or badly ventilated location.
Sucientairaccessingtothehousingoftheunithastobeensured,
there must not be any heat or anti-noise insulation within a 0.6m x 0.6m
areaaroundtheunit(non-ICratedxture).
Suitable for fastening on Unsuitable for covering by heat insulation
non-ammablesurfacesonly material
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeunitintotheopening.Fastenthexturebymeansoftwospringfasteners(2)totheopening
Alvays switch o power suply of the unit before connecting or disconnecting the unit
2
Toconnectneededcablestothexture,unscrewtwoscrews(4)fromtheplasticcover(3)andchipneeded
plasticthin-walledcovers(6)oinordertopasscablestotheconnectionblocks(5).
Theconnectionblocks(5)havethefollowingwiring:
Theprimarypowerinputservesforastandardpower(e.g.ArcPowerforAmbiane).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled.
fthextureissuppliedviathesecondarypower,thelightoutputofthexturecanbesetbyatrimmer.
Thexturecanbecontrolledbyoneofthefollowingmethods:DMX512
0-10V
DALI
ThextureisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALIchain
(In/Outmethod).
DMX connection 0-10V connection Power connection
PCB Function PCB Function PCB Function
0V - Shield 0V 0V + Power +
D+ Signal(+) D+ +10V - Power-
D- Signal(-)
3. DMX and DALI address setting and control
The DIP switch, located next to the connection blocks, allows to set a method of control, run test and also allows
toswitchthexturetotheupdatemodeincaseofsoftwareupdate.
3
DIP 10 - if switched to ON=test light
DIP11-selectionofxturecontrol:OFF=DMX512orDALI,ON=0-10V
DIP12-changefromOFFtoONpositionswitchesthexturetotheupdatemode(switchingtotheupdate
modeisnotnecessaryIftheRobeUploaderisusedforxtureupdate).
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to512.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLEDonPCBsignalswayofDMX
addresssetting:
LEDlights-DMXaddressissetbymeansoftheDIPswitch.
LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP 11 has to be set in OFF position.
ExampleofDMXaddresses:
DALI control
AddressingofthextureismadebymeansofanexternalDALIcontroller.TheexternalDALIcontrollerhasto
sendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontrolofthexture(xturewillnotrespond
toDMXcommands)anddeactivatingcommand(0=OFF)tostopcontrolofthexture.
DIP 11 has to be set in OFF position.
Note:IfDIP11=OFF(xtureiscontrolledbyDMXorDALI),therstcomingcommandswitchesthexturetothe
correspondingoperationmode(DMXoperationbyaDMXcommand,DALIoperationbyaDALIcommand).E.g.
thexturestaysinaDALIoperationandcomingDMXcommandswitchesthexturetoDMXoperation.Next
commandisaDALIcommandandswitchesthexturetotheDALIoperationetc.Ifyouneedthepermanent
DALIoperation,youhavetosendaDALIcommand8tothexture.
0-10V control
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI commands.
4. RDM
ThisxturesupportsRDMoperation.RDM(RemoteDeviceManagement)isabi-directionalcommunication
protocolforuseinDMX512controlsystems,itisthenewopenstandardforDMX512devicecongurationand
status monitoring.
RDMallowsyoutosetDMXaddress,selectDMXmodeandreadoutsoftwareversionofthexture.The.RDM
protocolisalsousedforthesoftwareupdateofthexturebymeansoftheRobeUploader.
4
5. Anti-glare ring installation
Inserttheantiglarering(1)intothextureuntilthreelocks(2)snapintoslots(3).
6. Adapter ring installation
1.Removebothspringfasteners(2)byunscrewingthefourscrewsM4x10(1).
2.Slidetheadapterring(4)ontothehousingofthexture.Screwthenewfasteners(3)onthehousing.
UseoriginalscrewsM4x10(1).
5
7. DMX protocol
version 1.1
Mode 1
Channel
Mode 2
Channel
Value Function Type of control
1 1
0-255
Dimmer
Light intensity coarse 0% -->100% proportional
- 2
0-255
Dimmer Fine
Light intensity from min. -->max. proportional
8. Technical specications
Inputvoltage: 24VDC
Max.powerconsumption: 40W
Protectionclass: CE: (ClassIII)
ETL:Class2orLVLE
Beamangle: 67°,80°withanti-glarering
Colourtemperature: 2700K,3200K,4000K,5000K,6500K
Control: DMX,DALI,0-10V,RDMcompatible
DMXchannels: 1(Mode1),2(Mode2)
TypicalLumenmaintenance: 70%@50,000hours
Ledlifeexpectancy: minimum50,000hours
Operatingambienttemp.range:  -20°C/+45°C(-4F/+113F)
Operatingtemperature: 75°C@Ambient+35°C(167°F@Ambient+95°F)
Totalheatdissipation: 136BTU/h(calculated)
Cooling: convection
Totalheatdissipation: 136BTU/h(calculated)
Housing: alluminium
Weight: 1.8kg
Installationmethod: viatwospringfasteners
ICrating: non-ICrated
Power/DMX/DALIconnection: screwconnectionblockDegsonDG306-5.0-02P
(Wirerange:22-14AWG(UL),1.5mm
2
(IEC))
Max.distancebetweenAmbianeand
ArcPowerforAmbiane: 1m(for2x18AWGcable)
Protectionfactor: IP20(withoutdiuserglass),IP20/IP54(withDiuserGlass)
AmbianewithoutDiuserGlass AmbianewithDiuserGlass
9. Optional Accessories
ArcPowerforAmbiane(P/N10063035)
Anti-GlareRing(P/N10980386)
DiuserGlassFrosted(P/N10980387)
AdapterRing(230-255mm)(P/N10980388)
10. Maintenance
Keepthextureclean,especiallylightsourceandtheribbedhousing.
6
11. Dimensions
mm [inch]
7
12. Software update
Software update by means of the DSU le.
Thefollowingitemsarerequiredinordertoupdatesoftware:
-PCrunningWindowsorLinuxormacOS
-DSUle
-FlashcableRS232/DMX(P/N13050624)ortheRobeUniversalInterface/RobeUniversalinterfaceWTX.
Toupdatesoftwareinthexture:
1.DSUleisavailablefromAnoliswebsiteathttps://www.anolislighting.com/
FilewithextensionzipisintendedforWindows(usedandtestedfromXPtoW10on32/64bitsystems).
FilewithextensiontbzisintendedforLinux(usedandtestedonDebianandUbuntu32/64bit).
File with extension dmg is intended for
macOS(usedandtestedonOSXuptoSierra)XQuartzrequired,
installitfromhttps://www.xquartz.org/
Savethedownloadletoafolderonyourcomputer.
Incasethatyouusewindows,extractlesintheziple(e.g.DSU_Ambiane_18051040.zip)
2.SwitchthextureoanddisconnectthexturefromDMXcontroller(IfyouuseDALIcontrol,switcho
theDALIcontroller).
3.IfyouusetheashcableRS232/DMX,connectaserialportofyourcomputerwithDMXinputofthexture
bymeansofthiscable(probablyyouwillneedsomeUSBtoRS232converterifyourcomputerhas
USBportsonly).
IfyouusetheRobeUniversalInterface,connectaUSBportofyourcomputerwiththeRobeUniversalInterface
bymeansoftheUSBcableandDMXinputofthexturewiththeDMXoutputoftheRobeUniversalInterface
viaaDMXcable.
4.Switchthextureonandswitchittotheupdatemode(svitchthe
DIP12fromOFFtoONposition)
.
Werecommendtocancelallrunningprogramsonyourcomputerbeforestartingthesoftwareuploader.
5.Double-clickthesoftwareuploaderle(e.g.DSU_Ambiane_18051040.exe)in
theextractedles.TheSoftwareUploaderprogramwillstartrunning.
8
6.Selectcorrect"COM"numberifyouusea
FlashcableRS232/DMX
or select "
Robe Universal Interface "
if you use the
RobeUniversalInterface/RobeUniversalInterfaceWTX
and then click on the "Connect" button.
7.IftheconnectionisOK,clickthe“StartUploading"buttontostartsoftwareuploading.Itwilltakeseveral
minutes to perform software update.
If the option "Incremental Update" is not checked, all processors will be updated (including processors with
thesamesoftwareversion).
Ifyouwishtoupdateonlyprocessorswithnewversionofsoftware,checkthe“IncrementalUpdate
box“.
Avoidinterruptingtheprocess.Updatestatusisbeingdisplayedinthe"InfoBox"window.
Whentheupdateisnished,thelinewiththetext“Fixtureissuccessfullyupdated“willappearin
this window.
8.SwitchthextureoandsettheDIP12toOFFposition.
Incaseuploadprocessisinterrupted(e.g.powerloss),thexturestaysin“Updatingmode”andyouwillhave
to repeat the software update again.
Software update by means of the Robe Uploader
Anotherway,howtoupdatesoftwareinthextures(especiallylargeinstallationofxtures)istousetheROBE
Uploader.ItisasoftwareforautomatizedsoftwareupdateofRobeandAnolisxtures.Ittakesadvantageof
RDMsupportandEthernetportsifpresentintheunits.
Thextureshastobeconnectedinadaisy-chain(max.32xtures)andvia
the
Robe Universal Interface/Robe
UniversalInterfaceWTX
andaUSBcableconnectedtothecontrolPCwiththeRobeUploaderrunning.
The control PC should be connected to the Internet.
9
TheRobeUploadersoftwareandusermanualisavailableat:
https://www.robe.cz/robe-uploader/
Note:
IfyoudothesoftwareupdatebymeansoftheRobeUploader,switchingxturestotheupdatemode(andfrom
theupdatemode)ismadeautomatically,withoutneedtoswitchtheDIP12toONposition.
TheRobeUploadersoftwarecannotbeusedifxturesareconnectedbymeansofDALIconnection.
Version1.7September4,2018
Specications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
/