Anolis Ambiane RGBW User manual

Category
Stroboscopes & disco lights
Type
User manual

Anolis Ambiane RGBW is a high power LED lighting fixture capable of generating colored light to be used in both indoor and outdoor environments. Controlled via DMX, DALI or RDM, it gives the user the ability to change the colors and intensity of the light with high precision. Due to its long lifespan and low power consumption, it is ideal for use in settings where energy efficiency and longevity are important, such as museums, galleries, retail spaces, and architectural lighting.

Anolis Ambiane RGBW is a high power LED lighting fixture capable of generating colored light to be used in both indoor and outdoor environments. Controlled via DMX, DALI or RDM, it gives the user the ability to change the colors and intensity of the light with high precision. Due to its long lifespan and low power consumption, it is ideal for use in settings where energy efficiency and longevity are important, such as museums, galleries, retail spaces, and architectural lighting.

1
User manual
Ambiane RGBW
The unit generates colored light by means of high power LEDs. The product was designed for indoor use only.
1. Attention
Theunitmustbeinstalledbyaqualiedelectricianinaccordancewithall
national and local electrical and construction codes and regulations.
The unit was designed for indoor use only.
Avoid looking directly into the LED light beam at close range!
Donotinstalltheunitnearhighlyinammableliquidsormaterials.
Do not allow anything to rest on the unit.
Donotinstalltheunitnearanopename.
Do not install the unit in dirty,dusty or badly ventilated location.
Sucientairaccessingtothehousingoftheunithastobeensured,
there must not be any heat or anti-noise insulation within a 0.6m x 0.6m
areaaroundtheunit(non-ICratedxture).
Resistance of the equipment is designed for electromagnetic environments E1, E2, E3
according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family
standard for audio, video, audiovisual and entertainment lighting control apparatus for
professional use. Part 2: Immunity.
The installation company should check levels of possible interferences above the tested levels
E1,E2,E3givenbythisstandard(e.g.transmittersinsurroundingarea)beforeinstallingtheequipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility
of multimedia equipment – Emission Requirements according to class B.
Suitable for fastening on Unsuitable for covering by heat insulation
non-ammablesurfacesonly material
Alvays switch o power suply of the unit before connecting or disconnecting the unit
2
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeunitintotheopening.Fastenthexturebymeansoftwospringfasteners(2)totheopening
Toconnectneededcablestothexture,unscrewtwoscrews(4)fromtheplasticcover(3)andchipneeded
plasticthin-walledcovers(6)oinordertopasscablestotheconnectionblocks(5).
Theconnectionblocks(5)havethefollowingwiring:
Theprimarypowerinputservesforastandardpower(e.g.ArcPowerforAmbiane).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled.
In case of primary power loss, the secondary power is enabled.
Ifthextureissuppliedviathesecondarypower,thelightoutputofthextureisawhitecolour(3200K)andits
light intensity can be set by a trimmer.
Thexturecanbecontrolledbyoneofthefollowingmethods:DMX512
DALI
ThextureisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALIchain
3
(In/Outmethod).
DMX connection Power connection
PCB Function PCB Function
0V - Shield + Power +
D+ Signal(+) - Power-
D- Signal(-)
3. DMX and DALI address setting and control
TheDIPswitch,locatednexttotheconnectionblocks,allowsyou,runatestlightandswitchthexturetothe
update mode in case of software update.
.
DIP10-ifswitchedtoON=testlight(thexturelightsat3200K)
DIP11-hastobeswitchedtoOFFpositiontoreceiveDMX512orDALI
DIP12-changefromOFFtoONpositionswitchesthexturetotheupdatemode(switchingtotheupdate
modeisnotnecessaryIftheRobeUploaderisusedforxtureupdate).
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to509.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLEDonPCBsignalswayofDMX
address setting:
LEDlights-DMXaddressissetbymeansoftheDIPswitch.
LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP 11 has to be set in OFF position.
ExampleofDMXaddresses:
DALI control
AddressingofthextureismadebymeansofanexternalDALIcontroller.TheexternalDALIcontrollerhasto
sendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontrolofthexture(xturewillnotrespond
toDMXcommands)anddeactivatingcommand(0=OFF)tostopcontrolofthexture.
DIP 11 has to be set in OFF position.
4
Note:IfDIP11=OFF(xtureiscontrolledbyDMXorDALI),therstcomingcommandswitchesthexturetothe
correspondingoperationmode(DMXoperationbyaDMXcommand,DALIoperationbyaDALIcommand).E.g.
thexturestaysinaDALIoperationandcomingDMXcommandswitchesthexturetoDMXoperation.Next
commandisaDALIcommandandswitchesthexturetotheDALIoperationetc.Ifyouneedthepermanent
DALIoperation,youhavetosendaDALIcommand8tothexture.
4. RDM
ThisxturesupportsRDMoperation.RDM(RemoteDeviceManagement)isabi-directionalcommunication
protocolforuseinDMX512controlsystems,itisthenewopenstandardforDMX512devicecongurationand
status monitoring.
RDMallowsyoutosetaDMXaddress,selectDMXmodeandreadoutsoftwareversionofthexture.
5. Anti-glare ring installation
Inserttheanti-glarering(1)intothextureuntilthreelocks(2)snapintoslots(3).
6. Adapter ring installation
1.Removebothspringfasteners(2)byunscrewingthefourscrewsM4x10(1).
2.Slidetheadapterring(4)ontothehousingofthexture.Screwthenewfasteners(3)onthehousing.
UseoriginalscrewsM4x10(1).
5
7. DMX protocol
Version 1.1
Mode 1
Channel
Mode 2
Channe
Mode 3
Channe
Value Function Type of control
1 1 1
0-255
Red
RedLEDssaturationcontrol(0-100%) proportional
- - 2
0-255
Red Fine
Red LEDs saturation control from min. -->max. proportional
2 2 3
0-255
Green
GreenLEDssaturationcontrol(0-100%) proportional
- - 4
0-255
Green Fine
Green LEDs saturation control from min. -->max. proportional
3 3 5
0-255
Blue
BlueLEDssaturationcontrol(0-100%) proportional
- - 6
0-255
Blue Fine
Blue LEDs saturation control from min. -->max. proportional
4 4 7
0-255
White
WhiteLEDssaturationcontrol(0-100%) proportional
- - 8
0-255
White Fine
White LEDs saturation control from min. -->max. proportional
- 5 9
0-255
Dimmer
Light intensity coarse 0% -->100% proportional
- 6 10
0-255
Dimmer Fine
Light intensity from min. -->max. proportional
8. Technical specications
Inputvoltage: 24VDC
Protection class : CE: (ClassIII)
ETL: Class 2 or LVLE
Max.powerconsumption: 40W
Beam angle: 67°, 80°, with anti-glare ring
Control: DMX,DALI,RDMcompatible
DMXchannels: 4(Mode1),6(Mode2),10(Mode3)
Typical Lumen maintenance: 70%@ 50,000 hours
Led life expectancy: minimum 50,000 hours
Operatingambienttemp.range:  -20°C/+45°C(-4F/+113F)
Operatingtemperature: 75°C@Ambient+35°C(167°F@Ambient+95°F)
Totalheatdissipation: 136BTU/h(calculated)
Cooling : convection
Totalheatdissipation: 136BTU/h(calculated)
Housing: alluminium
Weight: 1.8 kg
Installation method: via two spring fasteners
IC rating: non-IC rated
Power/DMX/DALIconnection: screwconnectionblockDegsonDG306-5.0-02P
(Wirerange:22-14AWG(UL),1.5mm
2
(IEC))
Max.distancebetweenAmbianeand
ArcPowerforAmbiane: 1m(for2x18AWGcable)
Protectionfactor: IP20(withoutdiuserglass),IP20/IP54(withDiuserGlass)
6
AmbianewithoutDiuserGlass AmbianewithDiuserGlass
9. Optional Accessories
ArcPower for Ambiane
Anti-GlareRing(P/N10980386)
DiuserGlassFrosted(P/N10980387)
AdapterRing(235-255mm)(P/N10980388)
10. Maintenance
Keepthextureclean,especiallylightsourceandtheribbedhousing.
7
11. Dimensions
mm [inch]
8
12. Software update
Software update by means of the DSU le.
The following items are required in order to update software:
- PC running Windows or Linux or macOS
-DSUle
-FlashcableRS232/DMX(P/N13050624)ortheRobeUniversalInterface/RobeUniversalinterfaceWTX.
Toupdatesoftwareinthexture:
1.DSUleisavailablefromtheROBEwebsiteathttps://www.robe.cz/architectural/download/#software-updates.
FilewithextensionzipisintendedforWindows(usedandtestedfromXPtoW10on32/64bitsystems).
FilewithextensiontbzisintendedforLinux(usedandtestedonDebianandUbuntu32/64bit).
File with extension dmg is intended for
macOS(usedandtestedonOSXuptoSierra)XQuartzrequired,
installitfromhttps://www.xquartz.org/
Savethedownloadletoafolderonyourcomputer.
Incasethatyouusewindows,extractlesintheziple(e.g.DSU_Ambiane_18051040.zip)
2.SwitchthextureoanddisconnectthexturefromDMXcontroller(IfyouuseDALIcontrol,switcho
theDALIcontroller).
3.IfyouusetheashcableRS232/DMX,connectaserialportofyourcomputerwithDMXinputofthexture
by means of this cable (probably you will need some USB to RS 232 converter if your computer has
USBportsonly).
If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface
bymeansoftheUSBcableandDMXinputofthexturewiththeDMXoutputoftheRobeUniversalInterface
viaaDMXcable.
4.Switchthextureonandswitchittotheupdatemode(svitchthe
DIP12fromOFFtoONposition)
.
We recommend to cancel all running programs on your computer before starting the software uploader.
5.Double-clickthesoftwareuploaderle(e.g.DSU_Ambiane_18051040.exe)in
theextractedles.TheSoftwareUploaderprogramwillstartrunning.
9
6.Selectcorrect"COM"numberifyouusea
FlashcableRS232/DMX
or select "
Robe Universal Interface "
if you use the
RobeUniversalInterface/RobeUniversalInterfaceWTX
and then click on the "Connect" button.
7.IftheconnectionisOK,clickthe“StartUploading"buttontostartsoftwareuploading.Itwilltakeseveral
minutes to perform software update.
If the option "Incremental Update" is not checked, all processors will be updated (including processors with
thesamesoftwareversion).
Ifyouwishtoupdateonlyprocessorswithnewversionofsoftware,checkthe“IncrementalUpdate
box“.
Avoid interrupting the process. Update status is being displayed in the "Info Box" window.
Whentheupdateisnished,thelinewiththetext“Fixtureissuccessfullyupdated“willappearin
this window.
8.SwitchthextureoandsettheDIP12toOFFposition.
Incaseuploadprocessisinterrupted(e.g.powerloss),thexturestaysin“Updatingmode”andyouwillhave
to repeat the software update again.
Software update by means of the Robe Uploader
Anotherway,howtoupdatesoftwareinthextures(especiallylargeinstallationofxtures)istousetheROBE
Uploader.ItisasoftwareforautomatizedsoftwareupdateofRobeandAnolisxtures.Itcantakeadvantageof
RDMsupportandEthernetportsifpresentintheunits.
Thextureshastobeconnectedinadaisy-chain(max.32xtures)andvia
the
Robe Universal Interface/Robe
UniversalInterfaceWTX
and a USB cable connected to the control PC with the Robe Uploader running.
The control PC should be connected to the Internet.
10
The Robe Uploader software and user manual is available at :
https://www.robe.cz/robe-uploader/
Note:
IfyoudothesoftwareupdatebymeansoftheRobeUploader,switchingxturestotheupdatemode(andfrom
theupdatemode)ismadeautomatically,withoutneedtoswitchtheDIP12toONposition.
TheRobeUploadersoftwarecannotbeusedifxturesareconnectedbymeansofDALIconnection.
Version2.4
March4,2021
Specications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Anolis Ambiane RGBW User manual

Category
Stroboscopes & disco lights
Type
User manual

Anolis Ambiane RGBW is a high power LED lighting fixture capable of generating colored light to be used in both indoor and outdoor environments. Controlled via DMX, DALI or RDM, it gives the user the ability to change the colors and intensity of the light with high precision. Due to its long lifespan and low power consumption, it is ideal for use in settings where energy efficiency and longevity are important, such as museums, galleries, retail spaces, and architectural lighting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI