Gianni Industries PSM-35 Installation guide

Type
Installation guide
PSM-35
Copyright © All Rights Reserved. P-MU-PSM-35 Published: 2020.07.09
PSM-35-D Series
Input:
Rated Voltage (VAC): 100 − 240
Voltage Range (VAC): 90 − 264
Rated Frequency (Hz): 50 / 60
Frequency Range (Hz): 47 − 63
Current (A): 0.8
No Load Power Consumption (W): 0.5
Energy Efficiency (%): 84 at full load
Output:
Rated Voltage (VDC): 12.5V
Voltage Range (VDC): 12.25 − 12.75V
Rated Current (A): 2.8
Current Range (A): 0 − 2.8
Ripple and Noise (mVp-p): 120 max.
Rise Time (ms): 80 at full load
Hold Up Time (ms): 50 at full load
Lithium battery users purchase reference:
Battery Recharge Time: Approx. 7 hours to fully recharge a
completely exhausted battery at 25°C ambient temperature
Battery Charging Current (A): 0.2 − 0.3
Rated Power (W): 40 max.
Protection:
AC Input: Current fuse protection
Output Short-Circuit: Hiccup mode occur and auto-recover without
damage when fault conditions are removed.
Output Over Voltage (V): 15 − 18
Output Over Current (A): 3.3 − 3.9
Over Temperature (°C): 110 ± 10
(output shutdown, reset by recycle AC input)
Battery Low-Voltage (V): 9.0 ± 0.5
Environment Specification:
Operating Temperature Range (°C): -20 ~ +40
Operating Humidity (%): 5 ~ 90 RH
Storage Temperature (°C) / Humidity (%): -25 ~ +70 / 5 ~ 90 RH
Led Indicator:
AC / DC: Lit when AC input normal and DC output normal
BATT: Lit when the battery is charging, Off when the battery has been
fully recharged or AC input fault
Others:
Dimensions (mm): 196.5(L) × 196.5(W) × 43(H)
Specification
Detachable design allow user replaced batteries
Compatible non-protected 18650 Lithium-ion* rechargeable cell
Fully Input and Output Protections
LED Indicator for AC Power ON, Normal DC Output and
Battery Charging
(*Operating temperature has not been verified by CE)
Features
Switching Power Supply with Battery
PSM-35-X Series
76mm
21mm
120mm
151.5mm
22.7mm
45mm
DG-350A
DG-760 DG-770-TP
116mm
34mm
70mm
PSM-35-D Series can be matched with controller
Copyright © All Rights Reserved. P-MU-PSM-35 Published:
2020.07.09
DG-350B
120mm
46.2mm
74mm
114mm
34mm
70mm
DG-350C
22.8mm
7
8.5mm
122.8mm
DG-700
Optional power cord
P-CB-AS-1.8 P-CB-EU-1.8 P-CB-UK-1.8 P-CB-US-1.8
DG-750
122.8mm
22.
8
mm
78.5mm
PSM-35 Series Parts List
1/2” (12m
m) Cable Hole
Copyright © All Rights Reserved. P-MU-PSM-35 Published: 2020.07.09
Flat head phillips screws , Cone point
X4
Anchor bolts
X4
PSM-35 Series Installation
Copyright
©
All Rights Reserved. P-MU-PSM-35 Published:
2020.07.09
PSM-35-D Series Wiring
-
-
-
Electro-magnetic Lock 1
(Fail-safe)
(No lithium battery attached )
N.O.
COM.
Exit Button 1
Exit Button 2
Power Supply Unit
Built-in DC-12V Alarm
Relay
Relay
Relay
INPUT
AC/DC
To Keypad
- + A B
To Keypad
+ - A B
Alarm
INPUT:
AC 100V~240 V
50 / 60 Hz
OR
-
-
-
Electric Strike
(Fail-secure)
Access control
Electric Dropbolt
(Fail-secure)
12VDC
(Max Current 100mA )
NC
COM
V+
NO
Electro-magnetic Lock 2
(Fail-safe)
  • Page 1 1
  • Page 2 2

Gianni Industries PSM-35 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document